Contents 3 Important information 4 Important notes 7 Using your extractor 8 Care and maintenance 9 Changing the charcoal filter 10 Mounting your extractor 11 Ducting 12 Installation 15 Mains electricity connection 16 Electrical information 16 Troubleshooting 17

Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that CDA reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial environment. This appliance is not designed to be used by people (including children) with reduced physical, sensorial or mental capacity, or who lack experience or knowledge about it, unless they have had supervision or instructions on how to use the appliance by someone who is responsible for their safety. Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified personnel.
Appliance information: Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a fault with your appliance and to register your appliance for guarantee purposes.
Appliance Model Serial Number
The product has been marked with the UKCA and CE symbols. This appliance is marked according to the European directive 2004/104/EC on Waste Electrical and Electronic equipment (WEEE).

At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services.
Disposing of a household appliance separately avoids possible negative consequences for the environment and health. It also enables the constituent materials to be recovered, saving both energy and resources. As a reminder of the need to dispose of household appliances separately, the product is marked with a crossed-out wheeled dustbin.
Please note:

CAUTION:Accessible parts may become hot when used with cooking appliances. In certain circumstances electrical appliance may be a danger hazard. A) There must be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning gas or other fuels. B)Do not check the status of the filters while the cooker hood is operat- ing. C)Do not touch the light bulb within half an hour after appliance has been use. D)Do not light a flame under the cooker hood. E)Avoid opening gasometer when there is no pan on the stove, as it is damaging for the filters and a fire hazard. F)Constantly check food frying to avoid overheated oil splashing and becoming a fire hazard. G) Disconnect the electrical plug prior to any maintenance. H) Regulations concerning the discharge of air have to be fulfilled. I) When the range hood and appliances supplied with energy Other than electricity are simultan ously in operation.The negative pressure in the room must not exceed 4 Pa (4x10-5 bar). J)If the supply cord is damaged,it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. K)This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowl- edge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children unless they are older than 8 and supervised.
Information and Advice

L)the range hood is inteded to be installed over a hob having no more than four hob elements. M) Indoor use and household use only. N)When the appliance is not in use and before cleaning, unplug the appli- ance from the outlet. O) Attention ! Observe the warning in the instruction sheet concerning the operation of the appliance when air is discharged from the room. P) There is a fire risk if cleaning is not carried out in accordance with the instructions. Q) The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room. I)Children should be supervised to ensure that they do not play with the appliance. S)Warning: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards. T)The installation height of hood shall not be less than 65cm. U)The filter screen must be cleaned regularly, otherwise there is a danger of fire. V)The installation must be carried out according to the screws and posi- tions required by the instructions, which will easily damage the connecting wires. W)If the supply cord is damaged, it must be replaced by the manufac- turer, its service agent or similarly qualified persons in order to avoid a hazard.
Information and Advice

Using your Extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking.
Fig. 1 A B C
B - Speed level buttons C - Light button
To switch on the extractor or to change the speed at any time when the extractor is running • Press the relevant “B” button for the first, second or third speed level as required.
Control Panel



Cleaning the grease filter The grease filters should be kept clean to minimise the risk of fire. At least once a month you should remove and clean the grease filters with hot soapy water. You can also wash the grease filters in a dishwasher, ensuring that you place it in an upright position to prevent damage from other items in the dishwasher. After rinsing and drying, replace the filters.
To remove the grease filters, pull open the handle on the grease filter. It will release at the handle side. Then lower the grease filter to remove it completely (fig. 2). To replace the grease filter, repeat the steps in reverse.
Please note: Cleaning the grease filters in the dishwasher may lead to discolouration. This is normal and does not constitute a fault with the appliance.
Changing the charcoal filter (re-circulating only) To ensure best performance of your extractor, you should replace the charcoal filters every four to six months, depending on use.
o attach a new charcoal filter, first remove the grease filters as
Then according to the position shown in Figure 3,
Adsorption the carbon filter to the body of the range hood, paying attention to the center installation of the carbon filter.

Changing the light This appliance is fitted with energy saving LED lighting that has a considerably longer life expectancy than traditional filament bulbs. These are not user-replaceable in the unlikely event of a failure. Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights. The light is designed for use during cooking and not for general room illumination. Extended use of the light can reduce the life span of the bulb.
In case of malfunction of the illumination system contact the technical service.
Replaceable (LED only) light source by a professional LED LED
When the extractor is to be installed above an electric hob, the minimum distance between the hob and extractor must exceed 600mm for ceramic and solid plate hobs and 550mm for induction Hobs. When the extractor is to be installed above a gas hob, the minimum distance between the hob and extractor must exceed 650mm.
If the instructions provided with your gas hob state that the required distance between the hob and extractor must be greater than 700mm, then that is the distance that should be observed; this is a legal requirement and may lead to your hob being disconnected from the gas supply and the installation being reported under RIDDOR (The height should be measured from the top of the burners).
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB, THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm.

The width of any hob must not be greater than the width of the extractor installed above it.
Ducting and ventilation For best performance and lowest noise output, we recommend the use of 150mm ducting. You can also use 120mm ducting but this will reduce performance. In general, the less ducting you use (i.e. distance
follows:
Longer ducting can be used but the performance of the extractor will likely be reduced.
Please note: Ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the hood. Use of ducting less than 150mm in diameter
extractor.

B - clearance required Gas: 650mm recommended. Electric: 600/550mm recommended.
A - burner height
Installation steps 1. Firstly, fix the vent outlet to the extractor body using four screws, as shown in fig 5.
ceiling · Extractor height · floor

the chimney section, use the calculation shown on this page for your extractor (also refer to fig 4):
A = Height of gas hob burner or electric
hotplate height from the kitchen floor B = Clearance required: Gas hobs 650mm recommended Electric hobs: Ceramic hobs and solid plate 600mm recommended; Induction hobs 550mm recommended.
A+B is the required height of the body of the extractor above the floor.
Next we need to calculate the required height of the extractor.
Whole extractor height = ceiling height - height above floor (A+B).

be at least the minimum height specified).
The metal casing of this appliance has been coated with a preservative to protect it during transport and storage. This should be removed during installation by using a non-abrasive stainless steel cleaner. Always follow the instructions given with the cleaner being used.

Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE.
We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.
FUSED SPUR OUTLET

The wires in the mains lead of this appliance are coloured in accordance with the following code:
BLUE = NEUTRAL, BROWN = LIVE, GREEN+YELLOW = EARTH
As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the terminals connecting to the fused spur, proceed as follows:



Attribute Symbol Units 1 9 K P C E n oita cifit n e dI le d o M Annual Energy Consumption AECHood 63.7 kWh Time increase factor f 1.7 y FDEHood 8.4 x EEIHood 89.7
QBEP 224.3 m3/h
PBEP 126.0 Pa
Maximum airflow QMAX 387.4 m3/h Measured electric power at Best WBEP 93.3 W
Nominal lighting power WL W Average illumination of the lighting system on the cooking surface
Measured power consumption in standby
P O 0.0 W
Sound power level LWA 61.0 dBA y GFEHood 69.7 (D) % E L y c n eiciff e p m a L Hood
E & O E. All instructions, dimensions and illustrations are provided for guidance only. CDA reserve the right to change specifications without prior notice.




For service or queries relating to your product please contact: The Customer Care Department on 01949 862 012 or email customer.care@cda.eu
Customer Care Department. The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY T: 01949 862 012 F: 01949 862 003 E: customer.care@cda.eu
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.