Heat only, or Cool only 72 72 H EAT Mo I2:34 2 - Wire Operation No Batteries Required Simple, Single Setpoint 7 Day Programmable 4 T ime Periods V ery Easy to Program Large, Easy T o Read Display Ther.
Ta ble Of Content s FRONT P ANEL DISPLAY QUICK STA RT Set the clock and go BASIC OPERA TION PROGRAMMING Time Periods ADV ANCED SETUP ABOUT ADV ANCED OPERA TION W ARRA NTY P age 1 CAUTION Follow Installation Instructions before proceeding . SET THERMOST AT T O MODE “ OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR REST ORING F ACT ORY DEF AULTS .
Front Panel P age 2 Liquid Cryst al Display with Thermoglow Up/Down Buttons On/Off Button Out side Button Heat or Cool Indicator Heat = Red, Cool = Green 1 2 3 4 5 72 70 H EAT Mo I2:00 2 3 4 5 1.
1 2 4 3 Mode Indicators Selects the operation mode of the equipment. HEA T - indicates the heat mode. COOL - indicates the air conditioning mode. OFF - indicates the entire system is turned off. PROGRAM ON - indicates the stored program is enabled to run.
5 6 7 8 Morning, Day , Evening & Night Indication Indicates the program time period. Page 8-1 1. Setup Indication Indicates the thermostat is in the programming mode. Page 12. Locked Indication Locked appears after the right combination of buttons are pressed, rendering the buttons inoperative.
During Setup & Programming: Pressing the Mode button selects different flashing items. (Represented in dark black ) Pressing the Up and Down buttons will modify the flashing selection. Press the On/Off button. While holding the On/Off press the Outside button for 2 seconds to enter Setup screens.
The HEA T setting indicates the temperature the r oom has to reach befor e the furnace will turn on to heat the room. OFF indicates the heating system is turned off . NOTE: The operating mode of this thermostat may be changed from the factor y default HEA T operation, to COOL operation in the Advanced Setup Section.
buttons. Adjust the desired Set T emperature with Pressing the up/down buttons in Heat or Cool will adjust only the H Cool set temperature. eat or Select Desired T emperature P age 7 Basic Operation 70 69 Pm H EAT Mo I2:00 70 O UTSIDE Outside T emperature Pressing the Outside button will display the outside temperature.
Programming 4 T ime periods P age 8 Press Press Press Press the On/Off button. While holding the On/Of f, press the Up button for 2 seconds to enter time period programming. Continued Select the Day of the Week. Adjust the start time for Morning. Adjust the heating setpoint for Morning.
Programming 4 T ime Periods P age 9 ON/OFF Press Press Press Continued Adjust the start time for Day . Adjust the start time for Evening. Adjust the heating setpoint for Day .
Programming 4 T ime Periods P age 10 Press Press Press Continued Adjust the start time for Night. Adjust the heating setpoint for Evening. (35 - 99 ) ON/OFF ON/OFF ON/OFF Adjust the heating setpoint for Night.
Programming 4 T ime Periods P age 11 Press ON/OFF Press the On/Off button. While holding the On/Of f, press the Up button to exit time period programming. ON/OFF T o Exit Programming Select Ye s to copy the stored program to the next day . Select No to continue manually storing the time period programming for the next day .
Advanced Setup P age 12 Press Press Press Continued Adjust the time of day clock. Select the day of the week. Press the On/Off button. While holding the On/Off, press the Outside button for 10 seconds to enter Setup screens. NOTE: Each step # is located at the top right corner of the display for easy reference.
Advanced Setup P age 13 Press Press Press Press Continued Select the operation of the thermostat: ON is 7-day programmable, OFF is non-programmable Configure the display . 1 = setpoint only 2 = room temperature with setpoint. Adjust the deadband from 1 - 6 degrees.
Advanced Setup P age 14 Select the display back- light always On , or Off after 8 seconds. On Off Select thermostat operation in degrees F ahrenheit or C entigrade. C F Press the On/Off button. While holding the On/Off press the outside button to leave the Setup screens.
Advanced Setup P age 15 S tep # Description Range Factory Default 1 T ime of day clock set 24 hour 12:00 Am 2 Day of the week Sun - Sat Monday 3 Operating Mode - Heat or Cool Heat / Cool Heat 4 Progra.
About Advanced Features & Operation P age 16 KEYP AD LOCK - T o prevent unauthorized use of the thermostat, the front panel buttons may be disabled. T o disable, or ‘lock’ the keypad, press and hold in the On/Off button. While holding the On/Off button in, press the Up and Down buttons in together .
About Advanced Features & Operation P age 17 OPTIONAL LOCKING COVER 72 72 70 70 H EAT H EAT Mo Mo I2:00 I2:00.
About Advanced Features & Operation P age 18 If the Two- Wire thermostat is losing time or showing PF or P - it may be neccessar y to install the 10 watt 250 ohm resistor that is supplied with the thermostat .
Proper installation of the thermost at will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance.
T urn off the power to the Heating/Air Conditioning system at the main fuse panel. Most residential systems have a separate breaker for disconnecting power to the furnace. Remove the cover of the old thermostat. If it does not come off easily check for screws.
STEP #3 INST ALL BACKPLA TE & WIRE P age 21 If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below , or the wiring diagrams that follow . * C may not be used on all systems. ** O/B is used if your system is a Heat Pump.
P age 22 Form: OM17-50 Catalog: 13TS-T A57 P/N 88-315 Rev . 1 W arranty Five- Year W arranty - This Product is warranted to be free from defects in material and workmanship. If defect appears within five years from the date of original installation , whether or not actual use begins on that date, then the product does meet this warranty .
An important point after buying a device Bryant P474-0401RF (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bryant P474-0401RF yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bryant P474-0401RF - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bryant P474-0401RF you will learn all the available features of the product, as well as information on its operation. The information that you get Bryant P474-0401RF will certainly help you make a decision on the purchase.
If you already are a holder of Bryant P474-0401RF, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bryant P474-0401RF.
However, one of the most important roles played by the user manual is to help in solving problems with Bryant P474-0401RF. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bryant P474-0401RF along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center