EN
Bryant logo
Official user manual

Bryant MACA

4 pages·27 KB·Air Cleaner·PDF·ENDEFRITNLJA
Bryant MACA
Table of Contents 14 sections TABLE 1—AIR CLEANER PRESSURE DROP · TABLE 2—DIMENSIONS · III. REPLACING FILTER MEDIA IN AIR CLEANER CABINET · II. MAINTENANCE · … ShowHide
Page 1 of the Bryant MACA user manual — TABLE 1—AIR CLEANER PRESSURE DROP
Page 1 · click to enlarge
Page 1
Bryant MACA — TABLE 1—AIR CLEANER PRESSURE DROP diagram (page 1)
Fig. 1
CancelsNew II MACA-12-1
Bryant MACA — TABLE 1—AIR CLEANER PRESSURE DROP diagram (page 1)
Fig. 2

SAFETY CONSIDERATIONS Installation and service of heating and air conditioning equipment can be hazardous due to system pressure and gas and electrical components. Only trained and qualified personnel should install, repair, or service heating and air conditioning equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on heating and air conditioning equipment, observe precautions in the literature, tags, and labels attached to or shipped with the unit and other safety precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warning or cautions attached to the unit. Consult local building codes and National Electrical Code (NEC) for special require- ments. It is important to recognize safety information. This is the safety-alert symbol

Fig. 1—Model MACA Mechanical Air Cleaner

. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAU- TION. These words are used with the safety-alert symbol. DAN- GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.

TABLE 1—AIR CLEANER PRESSURE DROP

SIZE 12 14 20 Airflow

(CFM) Resistance (In. wc)

Bryant MACA — TABLE 1—AIR CLEANER PRESSURE DROP diagram (page 1)
Fig. 3

600 0.055 0.045 0.04 800 0.08 0.06 0.05 1000 0.12 0.115 0.09 1200 0.16 0.16 0.115 1400 — 0.23 0.15 1600 — — 0.18 1800 — — 0.22 2000 — — 0.27

INTRODUCTION The Model MACA Efficient Mechanical Air Cleaner is designed for installation in the return-air duct system of any forced-air heating and/or cooling system. The model MACA Mechanical Air Cleaners are available in three sizes, 1200, 1400, and 2000 CFM. The Model MACA is a mechanical air cleaner incorporating special pleated filter media designed to remove dirt, dust, pollen and other microscopic particles from the air passing through it. The pleats provide an exceptionally large filtering face area in a very compact space which allows maximum dirt holding capacities with minimum air flow resistance. (See Table 1.)

3. Using standard practices, remove a section of return-air duct to allow installation of air cleaner cabinet.
4. Install air cleaner in duct opening. (Use a transition if openings are different).

INSTALLATION I. INSTALL AIR CLEANER CABINET IN RETURN-AIR SYSTEM

5. Mounting holes are provided for duct work attachment. (See Fig. 2). If adjoining duct work is flanged, install screws so that their heads are inside cabinet to prevent damage to filter during removal and installation.
6. Remove media filter from plastic bag and place media filter in cabinet. Directional arrows on filter cartridge must point in direction of air flow.
1. Remove and discard existing furnace or air handler filter(s). 2. Referring to Fig. 2 and 3 for air cleaner dimensions and typical installations, determine best installation location of air cleaner.
7. After unit has been secured, seal seams air tight with duct tape or caulking.
8. Reinstall cabinet front panel door assembly.
Page 2 of the Bryant MACA user manual — II. MAINTENANCE
Page 2 · click to enlarge
Page 2

B

5⁄8″

3⁄16″

225⁄8″

TABLE 2—DIMENSIONS

MODEL A B C MACAXCBBX012 18-1/8 13-3/4 5-1/4 MACAXCBBX014 18-1/8 13-3/4 7-1/4 MACAXCBBX020 22-1/8 17-3/4 7-1/4

Fig. 2—Dimensional Drawing

Periodic inspection and annual replacement of your filter will insure high efficiency air cleaning.

III. REPLACING FILTER MEDIA IN AIR CLEANER CABINET

1. Turn off power to furnace or air handler before removing door. 1. Open access door by pulling handle. Remove door completely. 2. Pull used filter straight out of cabinet. 3. Slide new filter cartridge into cabinet with "AIR-FLOW" arrow pointing in direction of air flow. 4. Replace door. 5. Turn power on.

II. MAINTENANCE

1. The filter in your mechanical air cleaner must be replaced periodically. The frequency of filter replacement is best determined by visual examination.

1″ · 25″

Page 3 of the Bryant MACA user manual — AIR FLOW
Page 3 · click to enlarge
Page 3

AIR FLOW

AIR FLOW AIR FLOW

UPFLOW FURNACE

NO TRANSITION UPFLOW FURNACE WITH TURNING VANES

UPFLOW FURNACE

WITH TRANSITION

AIR FLOW

AIR FLOW

HORIZONTAL

DOWNFLOW

Fig. 3—Typical Installations

Page 4 of the Bryant MACA user manual — CALL FOR FREE CATALOG 1-800-962-9212
Page 4 · click to enlarge
Page 4

SERVICE TRAINING

  • Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including:
  • Unit Familiarization
  • Maintenance
  • Installation Overview
  • Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog.

CALL FOR FREE CATALOG 1-800-962-9212

[ ] Packaged Service Training [ ] Classroom Service Training

© 1998 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 —4— Printed in U.S.A. iimaca121 Catalog No. 13MA-CA0

Ask about the Bryant MACA

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bryant MACA

Be the first to ask — other owners or our team will answer.

Original document

Bryant MACA manual PDF

4 pages·27 KB·Air Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…