SINGLE-PACKAGE ELECTRIC HEATING COOLING UNITS

HRVBBLHU HRVBBSVC

HRVBBLVU

Heat Recovery Ventilators

The Heat Recovery Ventilation (HRV) system offered by Bryant is the finest unit on the market today. The HRVB provides efficient and cost-effective heat recovery during the heating season when needed most.

As temperatures drop below 23°F (–5°C), indoor air is recirculated periodically through the heat exchanger core to prevent frost from forming. Competitors’ methods of supplementary electric defrost waste energy. Unlike rotary wheel heat exchangers which mix air streams, these cross flow or counterflow heat exchangers ensure that there is no mixing of the stale air stream with the fresh outdoor air stream.

A filter installed on the incoming outdoor air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required.

HRVBBLHU

The units’ acoustically engineered design makes them the quietest on the market and ensures that comfort is felt, not heard.

Unlatching 2 suitcase style latches allows easy removal of the filters and core for cleaning.

FEATURES

  • Energy saving defrost cycle
  • Cross flow, counterflow heat exchangers
  • Two filters on incoming outdoor air stream to protect the HRV core
  • Acoustical design
  • No-tools maintenance
  • Polypropylene heat exchanger core

HRVBBSVC

HRVBBLVU

Form No. PDS HRV.71.1

Page 2 of the Bryant HRVBBSVC user manual — HOME VENTILATING INSTITUTE
Page 2 · click to enlarge
Page 2

Model number nomenclature

HRV BB LHU 1 150

Maximum Capacity (CFM) 150 CFM 200 CFM 250 CFM 330 CFM Electrical Supply:

1 — 115 volts

Descriptor:

LHU — Large Horizontal Unit SVU — Small Vertical Unit LVU — Large Vertical Unit Brand:

Bryant Equipment Type:

TESTED/CERTIFIED

Bryant HRVBBSVC — TESTED/CERTIFIED diagram (page 2)
Fig. 1

HOME VENTILATING INSTITUTE

DIVISION OF AMCA

Climate Map for Energy and Heat Recovery Ventilators

Sacramento Salt Lake City

Washington D.C.

ERV Recommended w/HRV or ERV Wall Control

Show 31 more labels / short text on this page
Heat Recovery Ventilator · Edmonton · Vancouver · Calgary Regina Winnipeg · Timmins · Helena · Bismark · Montreal · Boise Salem · Green Bay · Syracuse · Ottawa · Milwaukee · Minneapolis · Boston · Detroit Madison · Hartford · Chicago Des Moines · Harrisburg · Indianapolis Springfield · Topeka Denver · Oklahoma City · Raleigh · Nashville · Atlanta Columbia · Honolulu · Austin · Baton Rouge · HRV Recommended · Orlando · ERV Recommended
Page 3 of the Bryant HRVBBSVC user manual — K V B CN 01 01 BAU
Page 3 · click to enlarge
Page 3

Controls and accessories part no. nomenclature

K V B CN 01 01 BAU

CONTROL DESCRIPTION BAU — Bryant Automatic Control BBS — Bryant Basic Control BST — Bryant Standard Control ACCESSORY DESCRIPTION 6FM — 6 in. Flowmeters (2) 7FM — 7 in. Flowmeters (2) 8FM — 8 in. Flowmeters (2) EXH — Exhaust Hood HOD — Intake Hood KIT — Balancing Kit FIR — Interlock Relay TIMER DESCRIPTION 20C — 20-Minute Timer Kit Carrier 60M — 60 Minute Adjustable Timer Kit FILTER DESCRIPTION 112 — 11-1/2 x 12-3/4 116 — 11-7/8 x 16-5/8 123 — 12-15/16 x 13-1/2 145 — 14-3/8 x 15-1/2 713 — 7-13/16 x 13-1/2 810 — 8-1/8 x 10-3/4 812 — 8-7/8 x 12-3/4 916 — 9 x 16-5/8 01 — Single Pack 01 — Part Number AC — Accessory CN — Control FL — Filter Media TM — Timer A — Original Series B — Second Series V — Heat Recovery Ventilator (HRV) K — Accessory Kit ACCESSORIES Kit NumberDescriptionWhere Used KVBCN0101CBSBasic HRV ControlUsed with all HRVs KVBCN0101CSTStandard HRV ControlUsed with all HRVs KVBCN0101CAUAutomatic HRV ControlHRVBLSVU, HRVBBLVU KVAAC0101FIRInterlock RelayWhen combining an HRV with a Furnace or Fan Coil KVATM010120C20 Minute Push Button TimerUsed with all HRVs when 20 minute manual operation is required KVATM010160M60 Minute TimerUsed with all HRVs, time is adjustable between 10 and 60 minutes KVAAC0101HODExterior Intake and Exhaust Hood2 Required KVAAC0101KITStart up Balancing KitStart up Balancing Kit, includes (2) 6 in. Flow Meter Collars & Magnehelic Gage KVAAC01016FM6 in. Flow Meter CollarAt start up, when 6 in. duct work is connected to HRV KVAAC01017FM7 in. Flow Meter CollarAt start up, when 7 in. duct work is connected to HRV KVAAC01018FM8 in. Flow Meter CollarAt start up, when 8 in. duct work is connected to HRV KVAFK0101150Internal FilterUsed with HRVBBLHU 1150 Unit 11 3/4 x 12 7/8 x 3/4 (2) KVAFK0201200Internal FilterUsed with HRVBBLHU 1250 Unit 11 3/4 x 16 3/4 x 3/4 (2) KVAFL0101713Internal FilterUsed with HRVBBSVU 1150 Unit 7 13/16 x 13 1/2 (2) KVAFL0101123Internal FilterUsed with HRVBBSVU 1200 Unit 12 15/16 x 13 1/2 (2) KVAFL0101123Internal FilterUsed with HRVBBLVU 1200 Unit 12 15/16 x 13 1/2 (2) KVAFL0101145Internal FilterUsed with HRVBBLVU 1200 Unit 14 3/8 x 15 1/2 KVAFL0101810Internal FilterUsed with HRVBBLVU 1330 Unit 8 1/8 x 10 3/4 (1) KVAFL0101145Internal FilterUsed with HRVBBLVU 1330 Unit 14 3/8 x 15 1/2 (1) KVAFL0101810Internal FilterUsed with HRVBBLVU 1200 Unit 8 1/8 x 10 3/4 (1)
Page 4 of the Bryant HRVBBSVC user manual — Automatic Control:
Page 4 · click to enlarge
Page 4

CONTROL FEATURES

Basic Control:

Allows the user to manually set fan speed to low or high as required to maximize comfort.

Standard Control:

Offers automatic dehumidistat control and the option to select continuous or intermittent fan operation. Setting the wall control to low will activate the continuous mode.

Automatic Control:

In addition to the features found with standard control, this package offers a recirculation mode. These controls may only be used to operate stand-alone units with the defrost option which enables the recirculation feature.

CONTROL DESCRIPTIONFAN SPEED CONTROLDEHUMIDISTAT CONTROLCONTINUOUS MODE*INTERMITTENT MODE*CIRCULATION MODE† BasicYesNoYesNoNo StandardYesYesYesYesNo Automatic‡YesYesYesYesYes * Air exchange with outside. † No air exchange with outside. ‡ Use only on units with defrost. CONTROL DESCRIPTION AND USAGE Fan Speed Control — Enables user to modulate fan speed from low to high air exchange with outside. Dehumidistat Control — Allows the user to select the relative humidity level at which the unit would change fan speed for dehumidification in the winter months. Continuous Mode — If the relative humidity inside the building is lower than selected, air exchange occurs with the outside at low speed. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures continuous air exchange for constant air quality. Intermittent Mode — If the relative humidity inside the building is lower than selected, no air exchange occurs and the system turns off. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures minimum air exchange level when the building is unoccupied to minimize operating costs. Circulation Mode — If the relative humidity inside the building is lower than selected, the ambient air would be circulated and filtered at high speed. If the relative humidity inside the house is higher than selected, air exchange would occur with the outside at high speed. Ensures continuous movement and filtration of air for maximum comfort. Available with automatic control only. AUTOMATIC DEFROST CYCLE FEATURES All models offer a non-electric defrost cycle feature which prevents frost and ice buildup within the heat recovery core. When the outside air temperature falls below 23°F (–5°C) it is electronically sensed and the dampers close the outside air ports. This allows warm indoor air to recirculate within the heat recovery core. The frequency of this cycle increases as the outside air temperature decreases. MODEL23°F TO 55°F (–5°C TO –15°C)4°F TO –17°F (–15.6°C TO –27.3°C)BELOW –18°F (–27.8°C) DEFROST*EXCHANGE†DEFROST*EXCHANGE†DEFROST*EXCHANGE† HRVBBLHU6 Minutes60 Minutes6 Minutes32 Minutes6 Minutes20 Minutes HRVBBSVU6 Minutes60 Minutes6 Minutes32 Minutes6 Minutes20 Minutes HRVBBLVU6 Minutes60 Minutes6 Minutes32 Minutes6 Minutes20 Minutes

* All defrost times are in the standard mode (as shipped) † Time between defrost when within specified temperature range

Page 5 of the Bryant HRVBBSVC user manual — B
Page 5 · click to enlarge
Page 5
Gmm196.9255.6 in.7-3/410-1/16 Fmm111.3111.3 in.4-3/84-3/8 Emm288.9283.9 in.10-3/811-3/16 Dmm368.9368.9 in.14-1/214-1/2 Cmm143.3128.1 in.5/585-1/16 Bmm104147.7 in.4-1/165-13/16 Amm384.2483 in.15-1/819 MODEL NO.HRVBBLHU1150HRVBBLHU1250

15" (381.0)

2.FRESH AIR FROM HRV TO HOUSE

5 7 / 8 " DIA (149.2)

4 PLCS

3.STALE AIR FROM HOUSE TO HRV

4.STALE AIR FROM HR TO OUTSIDE

F

1.FRESH AIR FROM OUTSIDE

E

G

167/8" (428.6)

NOTES:

25/16" (58.7)

181/8" (460.4)

DIMENSIONS

301/4" (768.3)

2 PLCS

4 PLCS 1" (25.4)

20" (508.0)

23/16" (56.2)

43/4" (120.6)

B

D

Page 6 of the Bryant HRVBBSVC user manual — DIMENSIONS (continued)
Page 6 · click to enlarge
Page 6
Gmm506.2506.2 in.19-15/1619-15/16 Fmm149.2174.6 in.5-7/86-7/8 Emm344.5430.2 in.13-9/1616-15/16 Dmm392.1369.9 in.15-7/1614-9/16 Cmm388.2490.6 in.13-5/1619-5/16 Bmm119.1208.0 in.4-11/168-3/16 Amm469.9622.2 in.18-1/224-1/2 MODEL NO.HRVBBSVU1150HRVBBSVU1200
Bryant HRVBBSVC — DIMENSIONS (continued) diagram (page 6)
Fig. 2 · DIMENSIONS (continued)

DIMENSIONS (continued)

Page 7 of the Bryant HRVBBSVC user manual — HRVBBLVU1200 or HRVBBLVU1330
Page 7 · click to enlarge
Page 7
Bryant HRVBBSVC — HRVBBLVU1200 or HRVBBLVU1330 diagram (page 7)
Fig. 3 · HRVBBLVU1200 or HRVBBLVU1330

HRVBBLVU1200 or HRVBBLVU1330

DIMENSIONS (continued)

18 5⁄16″ [465.1] 2 3⁄16″ [55.6]

19 1⁄16″ [484.2] 8 3⁄16″ [208.0]

Page 8 of the Bryant HRVBBSVC user manual — PHYSICAL DATA
Page 8 · click to enlarge
Page 8

PHYSICAL DATA

MODEL DESCRIPTIONCONVENTIONALCOMPACTHIGH EFFICIENCY Model No.HRVBBVHU1150HRVBBVHU1260HRVBBSVC1150HRVBBSVC1200HRUBBLVU1150HRUBBLVU1200HRUBBLVU1330 Port LocationsSidesSidesTopTopTopTopTop Core TypePolypropylene Cross FlowPolypropylene Cross FlowPolypropylene Cross FlowPolypropylene Cross FlowPolypropylene Cross FlowPolypropylene CounterflowPolypropylene Counterflow Weight — lb (kg)65 (29.5)73 (33.2)60 (27)80 (36.3)80 (36.3)120 (54.5)120 (54.5) Shipping Weight — lb (kg)75 (34)83 (37.6)75 (34)89 (40.4)89 (40.4)143 (64.9)143 (64.9) Shipping Dimensions (in.) Height Width Depth23 1/16 36 1/16 17 13/1622 15/16 35 1/16 22 5/1631.5 23.25 26.0031.5 23.25 26.0031.5 23.25 26.0047.5 26.0 26.047.5 26.0 26.0 PERFORMANCE DATA MODEL DESCRIPTIONCONVENTIONALCOMPACTHIGH EFFICIENCY Model No.HRVBBLHU1150HRVBBLHU1250HRVBBSVC1150HRVBBSVC1200HRVBBLVU1150HRVBBLVU1200HRVBBLVU1330 Capacity — CFM @ 0.5– 0.3ESP (in. wc)130–168191–210106–150177–211123–141189–209300–334 Efficiency (Sensible) — percent 32°F (0°C) –13°F (–25°C)65 6565 6069 6077 6781 6984 7280 74 Efficiency (Latent) — percent @ all temperatures0000000 Heat Core Exchange Area — cu ft (cu m)120 3.4166 4.790 8.4144 13.3144 13.3210 19.5210 19.5 ELECTRICAL DATA CONVENTIONALCOMPACTHIGH EFFICIENCY ModelHRVBBLHU1150HRVBBLHU1250HRVBBSVC1150HRVBBSVC1200HRVBBLVU1150HRVBBLVU1200HRVBBLVU1330 Voltage120120120120120120120 Max Power — watts150218115195115250500 Max Amps1.41.91.21.81.22.25.4
Page 9 of the Bryant HRVBBSVC user manual — EXAMPLE:
Page 9 · click to enlarge
Page 9

METHODS TO SIZE HRV’S

METHOD 1

1. Calculate cu ft of occupied space. 2. Multiply by recommended air changes per hr (AC/h). 3. Divide by 60 minutes per hr to convert to CFM.

EXAMPLE:

2000 sq ft with 8 ft ceiling 0.35 air changes per hr (AC/h)

(2000 sq ft x 8 ft ceiling x 0.35 AC/h) / 60 min/h = 93.3 CFM

METHOD 2

1. Multiply number of people times 15 CFM/person. 2. Multiply number of bath rooms 20 CFM/each. 3. Add 25 CFM for kitchen.

EXAMPLE:

2 people 2 baths 1 kitchen

(2 x 15) + (2 x 20) + 25 = 95 CFM

ADDITIONAL HEATING AND COOLING LOAD CHARTS

Although the ventilators process the outside air before it enters the home, additional heating and cooling loads need to be considered.

HEATING LOAD BTU

Outside Temp °FHeat Load (Btuh) @ Inside Design Temp 72°F HRVBBLHU1150HRVBBSVC1250HRVBBSVC1150HRVBBSVC1200HRVBBLVU1150HRVBBLVU1200HRVBBLVU1330 –254,6888,1656,9707,6905,5006,6509,990 –204,4667,7446,4707,0905,0306,0709,310 –154,5988,0085,9906,5204,5905,5108,650 –104,3347,5475,5205,9704,1604,9708,000 –54,0697,0875,0705,4403,7504,4707,380 03,8056,6274,5504,8403,3003,9106,640 53,5416,1674,1304,3602,9403,4706,060 103,5026,1003,7303,9002,6003,0505,500 153,2205,6083,2903,4002,2402,6004,870 202,9385,1162,9303,0001,9402,2404,350 252,9505,1382,5802,6101,6701,9103,850 302,6364,5912,2402,2501,4101,6003,370 352,3224,0451,9001,8801,1601,3002,870 402,0093,4981,6001,5601,9401,0402,430

The heating load chart shows the heating loads in Btuh for a range of winter design temperatures for each model of ventilator.

EXAMPLE:

The heating design temperature for Milwaukee, WI is –4°F. At –5°F, the additional heating load of the HRVBBLHU1250 is 8417 Btuh. This additional load should be taken into consideration when sizing the heating equipment.

Page 10 of the Bryant HRVBBSVC user manual — EXAMPLE:
Page 10 · click to enlarge
Page 10

COOLING LOAD BTU

Outside Enthalpy Btu/lbCooling Load (Btuh) @ Inside Design Temp 75°F and 50% Relative Humidity HRVBBLHU1150HRVBBLHU1250HRVBBSVC1150HRVBBSVC1200HRVBBLVU1150HRVBBLVU1200HRVBBLVU1330 306701,0717809907709901,390 311,0901,7411,3001,6501,2901,6502,310 321,5092,4111,8202,3101,8002,3103,240 331,9283,0802,3402,9702,3102,9704,170 342,3473,7502,8603,6302,8303,6305,090 352,7664,4193,3804,2903,3404,2906,020 363,1855,0893,9104,9503,8604,9506,940 373,6045,7594,4305,6104,3705,6107,870 384,0236,4284,9506,2704,8906,2708,790 394,4427,0985,4706,9305,4006,9309,720 404,8617,7675,9907,5905,9107,59010,650 415,2808,4376,5108,2506,4308,25011,570 425,6999,1077,0308,9106,9408,91012,500

The cooling load chart shows loads in Btuh as well. To use the cooling load chart, first find the design enthalpy from a psychrometric chart using the design dry bulb and wet bulb temperatures. (See psychrometric chart on p. 11.) The cooling load can then be found for a range of enthalpies for each ventilator.

EXAMPLE:

The cooling design dry bulb temperature for Milwaukee, WI is 87°F and the average wet bulb at that temperature is 73°F. On the psychrometric chart the enthalpy is about 37.7 Btu/lb of dry air which will round up to 38 Btu/lb of dry air. In the left column, at 38 Btu/lb the HRVBBLHU1250 would have an additional cooling load of 6428 Btuh. This additional load should be taken into account when sizing the air cooling equipment.

Page 11 of the Bryant HRVBBSVC user manual — PSYCHROMETRIC CHART
Page 11 · click to enlarge
Page 11
Bryant HRVBBSVC — PSYCHROMETRIC CHART diagram (page 11)
Fig. 4

0 45 50 55 60 65 70 75 80 85 90 95 100 105 110

Enthalpy at saturation, Btu per pound of dry air

PSYCHROMETRIC CHART

Below 32˚F, properties and enthalpy deviation lines are for ice.

Page 12 of the Bryant HRVBBSVC user manual — FORM PDS HRV.71.1
Page 12 · click to enlarge
Page 12
Bryant HRVBBSVC — SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE diagram (page 12)
Fig. 5

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

UNIT MUST BE INSTALLED IN ACCORDANCE

WITH INSTALLATION INSTRUCTIONS

CancelsNew

FORM PDS HRV.71.1

© 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 12HR-VBO 3-00

Ask about the Bryant HRVBBSVC

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bryant HRVBBSVC

Be the first to ask — other owners or our team will answer.