Instruction/ maintenance manual of the product FAN COIL UNITS FF1DNA Bryant
Go to page of 8
Form No. PDS FF1D.18.2 FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FEA TURES The FF1DNA and FF1DNE F an Coil units are designed as upflow indoor air handlers f or split-system heat pumps and air conditioners. The y are av ailable with f actor y- or field-installed electric heaters both of which include the disconnect.
— 2 — MODEL NUMBER NOMENCLA TURE CER TIFICA TION APPLIES ONL Y WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. PHYSICAL D A T A NO TE: Rough-in dimensions are 38-1/4 x 22-1/4 inches. CLEARANCES A minimum clearance of 21 in. is required in front of the access panels for servicing.
— 3 — DIMENSIONS — FF1DNA, FF1DNE A98336 OUTLET AIR INLET AIR SUCTION TUBE COIL 1 1 ⁄ 8 ″ DIA. KNOCKOUT SIDE VIEW FRONT VIEW TOP VIEW BOTTOM VIEW PRIMARY DRAIN PATCH PLATE FAN COIL BASE BLOWER, CONTROL AND ELECTRIC HEATER ACCESS PANEL LIQUID TUBE FILTER MEDIA SECONDARY DRAIN LOW VOLTAGE ENTRY ( 7 ⁄ 8 ″ DIA.
— 4 — SPECIFICA TIONS See notes on page 5. UNITS WITHOUT ELECTRIC HEA TERS OR CONTROLS UNIT SIZE 0180 0240 0300 RA TINGS & PERFORMANCES Nominal Capacity (Btuh)* 18,000 24,000 30,000 Nominal Ai.
— 5 — SPECIFICA TIONS Continued * Rated in accordance with U .S. Gov ernment DOE test procedures and/or ARI Standard 210/240-94. † Use copper wire only .
— 6 — COOLING CAP ACITIES (MBtuh) * Saturated suction lea ving ev aporator coil. COIL REFRIGERANT TEMPERA TURE* ( ° F) UNIT SIZE EV APORA T OR AIR CFM and BF 35 40 45 50 55 Evap Air — Entering W et-Bulb T emp ( ° F) 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 018 400 27 23 19 25 20 16 22 17 13 19 14 10 15 10 8 0.
— 7 — AIR DELIVER Y (CFM) A T INDICA TED EXTERNAL ST A TIC PRESSURE AND V OL T A GE NO TE: Data re fl ects a dry coil, fi lter, and 11-kw electric heater installed.
— 8 — SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS FF1D.18.1 Form PDS FF1D.18.2 © 2003 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231 PRINTED IN U.
An important point after buying a device Bryant FAN COIL UNITS FF1DNA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bryant FAN COIL UNITS FF1DNA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bryant FAN COIL UNITS FF1DNA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bryant FAN COIL UNITS FF1DNA you will learn all the available features of the product, as well as information on its operation. The information that you get Bryant FAN COIL UNITS FF1DNA will certainly help you make a decision on the purchase.
If you already are a holder of Bryant FAN COIL UNITS FF1DNA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bryant FAN COIL UNITS FF1DNA.
However, one of the most important roles played by the user manual is to help in solving problems with Bryant FAN COIL UNITS FF1DNA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bryant FAN COIL UNITS FF1DNA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center