Form No. PDS BS1A.75.3

B W 9 A A N 000 075 A A AA
Variations AA — Standard
Type of System W — Water S i— Steam
Series A i— Original
Combustion/Ignition 1 — Natural Draft/Standing Pilot 2 — Natural Draft/Electronic 3 — Induced Draft/Electronic 4 — Oil Burner/Without Tankless Coil 5 — Oil Burner/With Tankless Coil 9 — 90% Direct Vent/Sealed Combustion
Labeling A — Common Unit G — Canada Only (oil)
Heating Size Btu Input (x 1000) Electrical A 110 to 125 60 Hz
Fuel H — Heating Oil N — Natural Gas P — Propane
See notes on page 3.
B — Boiler · Model Code · Cooling

* 2–6 Section Models on BS1, BS2, BW1, and BW2; 2–5 Section Models on BW3. † 7–9 Section Models on BS1, BS2, BW1, and BW2; 6–7 Section Models on BW3. Note: Accessory High Limit Control is a strap-on aquastat used as an auxiliary limit or reverse acting circulator control.

2 3 4 5
TOTAL HEAD FEET
8 12 16 20 24
WATER BOILER CIRCULATOR CURVE
ELECTRICAL DATA
ama
®
ASME
®

The BW9 is a gas fired direct vent condensing hot water boiler with cast aluminum heat exchanger sections. A revolutionary cast aluminum heat exchanger means better heat transfer and thermal storage than similarly sized cast iron boiler, which results in higher efficiency. The heating system water absorbs large amounts of heat from the cast aluminum heat exchanger, cooling the flue gases and causing condensation. Sealed combustion, premix gas burner, and low flame temperature means drastically reduced CO and NOx emissions, which contribute to a cleaner and healthier environment.
The BW9, unlike normal residential atmospheric and induced draft boilers, takes its combustion air directly from the outdoors (sealed combustion) and does not compete with building occupants for fresh air. Sealed combustion (also known as “direct vent”) is the safest and best way to obtain plenty of clean combustion air. The induced draft fan draws in the outside combustion air, then takes the cooler flue gases from the heat exchanger and provides a positive removal of the flue gases from the building through inexpensive and readily available PVC and CPVC pipes.
—Three sizes ranging from 50,000 through 100,000 Btuh input.
—Each boiler is completely assembled, including all controls (except room thermostat). All necessary wiring is factory installed. The boiler is ready for gas piping, room thermostat, and electrical power connections as shipped. Circulator is shipped pre-wired with 6 ft bx conduit for easy installation for supply side pumping.
—This boiler is direct vented with PVC and CPVC pipe. See the Installation Instructions for common venting requirements.
—These sections speed heat transfer to the boiler water. With faster thermal response, greater comfort and economy are achieved.
—Provides quiet operation and improved combustion efficiency.
—Integrated Boiler Control provides safe, dependable operation of burners. Factory-installed safety components provide maximum safety against overheating, pressure buildup, and low-water operation.
—Each section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers.
—With factory approved conversion kit accessory.
—The aluminum sections are covered by a limited 15-year warranty on the entire assembly. Circulator pump is covered by a limited 3-year warranty. All other parts are covered by a 1-year limited warranty.


ALTERNATE SUPPLY & RETURN OPENINGS (1-1/4" NPT (31.75mm) CONNECTIONS PROVIDED INSIDE BOILER CABINET)
JUNCTION BOX FOR 120 V POWER, 120 V CIRCULATOR BEADS, AND 24 V THERMOSTAT LEADS
ALTERNATE BOILER WATER SUPPLY AND RETURN (31.75mm) CONNECTIONS (1-1/4" NPT BOILER CABINET) PROVIDED INSIDE
STANDARD BOILER WATER SUPPLY & RETURN OPENINGS (1-1/4" NPT (31.75mm) CONNECTIONS PROVIDED INSIDE BOILER CABINET)

Gas input ratings are for elevations up to 2000 ft. In the USA, for elevations above 2000 ft., reduce input per the charts supplied in the high altitude derate kits. In Canada, boilers may be used at high altitude by using a certified field conversion kit.
*

Models BS1 and BS2 Gas-Fired Steam Boilers provide fast heat quietly and economically to assure the finest in hydronic heating. These boilers provide quality design in a small, compact unit easily installed in a basement, garage, or utility room. They can be installed on a combustible floor when an optional combustible floor base is used. The model BS1 and BS2 design is CSA and A.G.A. certified for use with natural and is convertible to propane gas with accessory kit.
—Sizes 75,000 through 299,000 Btuh input are available.
—Each boiler is completely assem- bled, including all controls (except room thermostat). All necessary wiring is factory installed. The boiler is ready for gas, water, room thermostat, and electrical connections as shipped.
—These sections speed heat transfer from the flue gases to the boiler water, with faster ther- mostat response, providing greater comfort and economy. Max- imum heat is produced at a lower level on the thermal-pin sections, leading to peak efficiency.
—Provide quiet operation, corrosion resistance and improved combustion efficiency. Propane convertible – with accessory kit.
—An automatic gas valve and continuous pilot or intermittent pilot provide quiet, dependable operation of the burners. Factory-installed safety components assure protection against overheating, pressure buildup, and low-water operation.
—The casing is fully insulated with fiber- glass for maximum operating efficiency and economy.
—The Model BS1 and BS2 is designed with automatic vent damper to recover chimney loss during off cycle.
—Each section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. Maximum allowable working pressure is 50 psig. The maximum allowable pressure is 15 psig for steam boilers.
—These boilers incorporate an integral draft system to simplify installation. No external draft diverter is needed.
—The cast-iron sections are covered by a non- prorated 12-year warranty on the entire assembly. Vent damper covered by 5-year warranty. All other parts are covered by a 1-year limited warranty.

Factory authorized and listed, field installed.
*

Ratings are for altitudes to 2000 ft. Ratings for units for altitudes over 2000 ft are 4% less for each 1000 ft above sea level. Ratings in sq ft are computed at 240 Btuh/sq ft for steam boilers.
*

Models BW1 and BW2 Gas-Fired Hot Water Boilers provide fast heat quietly and economically to assure the finest in hydronic heating. These boilers provide quality design in a small, compact unit easily installed in a basement, garage, or utility room. They can be installed on a combustible floor when an optional combustible floor base is used. The models BW1 and BW2 design is CSA and A.G.A. certified for use with natural and is convertible to propane gas with accessory kit.
—Sizes 37,500 through 280,000 Btuh are available.
—Each boiler is completely assembled, including all controls (except room thermostat). All necessary wiring is factory installed. The boiler is ready for gas, water, room thermostat, and electrical connections as shipped.
—These sections speed heat transfer from the flue gases to the boiler water with faster thermostat response, providing greater comfort and economy. Maximum heat is produced at a lower level on the thermal-pin sections, leading to peak efficiency.
—These boilers incorporate an integral draft sys- tem to simplify installation. No external draft diverter is needed.
—Provide quiet operation, corrosion resistance and improved combustion efficiency. Propane convertible – with accessory kit.
—An automatic gas valve and continuous pilot or inter- mittent pilot provide quiet, dependable operation of the burners. Factory-installed safety components assure protection against overheating, pressure buildup, and low-water operation.
—The casing is fully insulated with fiberglass for maximum operating efficiency and economy.
The Model BS1 and BS2 is designed with automatic vent damper to recover chimney loss during off cycle
Each section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers.
—The cast-iron sections are covered by a non-prorated 20-year warranty on the entire assembly. Vent damper covered by 5- year warranty. Circulator pump covered by 3-year warranty. All other parts are covered by a 1-year limited warranty.

Burners—Stainless/Titanium Alloy No. 1 2 3 4 5 6 7 8 Burners—Orifice Drill Size Natural 34
Full Load Amps 0.70 Flange Size FPT In. 1-1/4
Factory authorized and listed, field installed. † A 4-in. vent damper is supplied. A 4-in. to 3-in. reducer is also furnished.
*


1 1⁄4″ RETURN 1 1⁄4″ NPT

Ratings are for altitudes to 2000 ft. Unit ratings for altitudes over 2000 ft are 4% less for each 1000 ft above sea level.
*

Model BW3 Gas-Fired Induced-Combustion Water Boilers are the answer to energy-efficient residential hydronic heating. They provide fast, almost instant, heat quietly and economically. These boilers provide quality design in a small, compact unit easily installed in a basement, garage, or utility room. They can be installed on a combustible floor when an optional combustible floor kit is used. The design of model BW3N is CSA and A.G.A. certified for use with natural gas and is convertible to propane gas with accessory kit.
—Six sizes ranging from 42,500 through 225,000 Btuh input.
—Each boiler is completely assembled, including all controls (except room thermostat). All necessary wiring is factory installed. The boiler is ready for gas, water, room thermostat, and electrical power connections as shipped.
—This boiler can be vented into any approved chimney or Type B-1 vent. Common-venting with an existing water heater is acceptable in vertical vent systems. See the Installation Instructions for common venting requirements. The induced-combustion design also eliminates the need for a vent damper.
—These sections speed heat transfer from the flue gases to the boiler water, with faster ther- mostat response, providing greater comfort and economy.
—Provide quiet operation, corrosion resistance, and improved combustion efficiency. Propane convertible with accessory kit.
—An automatic gas valve and intermittent pilot provide quiet, dependable operation of the burners. Factory-installed safety components provide maximum safety against overheating, pressure buildup, and low-water operation.
—Fully insulated with fiberglass for maximum operating efficiency and economy.
Each section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers.
—The Boiler is listed for power venting with field controls power venting kit.
—The cast-iron sections are covered by a non-prorated 20-year warranty on the entire assembly. Circulator pump covered by 3-year warranty. All other parts are covered by a 1-year limited warranty.



5 5⁄8″ 5 5⁄8″

Gas input ratings are for elevations up to 2000 ft. For elevations above 2000 ft, reduce input 4% for each 1000 ft above sea level. † Selection factors providing for piping loss and starting load are those recommended by the Institute of Boiler and Radiator Manufacturers. Net water boiler
ratings are based on an allowance of 1.15. ‡ In accordance with U.S. Government test procedures.
*

The modern design and attractive appearance of the models BW4 and BW5 Oil-Fired Water Boilers make them ideal for installation in any area. The boilers are shipped fully assembled and wired, including all controls (except barometric draft regulator). The compact 22-gage steel cabinet has a baked-on enamel paint finish for durability. A 1-in. layer of thermal insulation is applied inside the jacket for protection and thermal efficiency. The flame retention head burner
provides efficient fuel usage. A wet base cast iron block with thermal pins surrounds the combustion area for better heat transfer from flue gases to water.
—The factory supplied barometric draft control can easily be installed in the vent pipe for optimum draft and combustion efficiency.
—Factory-wired controls on units with tankless hot water coil include a triple aquastat relay with high/low limit protection and circulator control.
—A 24-v transformer is combined with the aquastat assembly. The transformer will supply power efficient to power a 3-zone system on BW5 models. Factory installed combination pressure/ temperature gage and a pressure relief valve.
—Units are available with or without tankless heater coil. The coil provides a supply of hot water for normal domestic purposes or an accessory tankless heater coil can be added later.
—A factory-installed drain is provided should the boiler ever need to be drained. Oil primary control prevents boiler in operation in the event of flame loss.
—Each section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers.
—Circulator is shipped pre-wired with 6 ft bx conduit for easy installation for supply side pumping.
—The cast-iron sections are covered by a non- prorated 20-year warranty on the entire assembly. Oil burner and circulator pump covered by 3-year warranty. All other parts are covered by a 1-year limited warranty.
—This provides cleaner burning and quieter operation. Valve is included on all burner types.
—This unique design offers uninhibited access for set-ups, service, and maintaining the burner. Routine cleaning is also much easier.
Water Capacity Gal 9.6 11.6 13.7
Combustion Chamber Target Wall Ceramic Fiber
Type Manufacturer/Model Beckett/Model AFG Flame Retention Head Burner
Oil Pump Single Stage
Fuel Type No. 1 or 2 Fuel Oil Rated Load Amps 3 Amps
Combination Control Without Heater High Limit, Circulator Relay, & Cad. Cell Relay
With Heater High & Low Limit, Circulator Relay, & Cad. Cell Relay
Pressure/Temperature Gage Psig 0–60
F 60–260 ASME Pressure Relief Valve Psig 30
Full Load Amps 0.70 Flange Size FPT In. 1-1/4
Draft Regulator Furnished · °

1 1 ⁄ 4 ″ SUPPLY
C B
CONTROL
1 1 ⁄ 4 ″ RETURN
TANKLESS HEATER 1⁄2″ N.P.T.
VALVE
FRONT SIDE REAR
UNIT SIZE A B C
140 17-3/4 6 9-3/4
210 21 6 11-3/8
280 24-1/4 6 13
* Clearance 18 in. for BW5. † Service clearance requirement 24 in.
NET I=B=R RATING
FIRING
INPUT
PACITY
RATE +GPH A.F.U.E. ++
MINIMUM CHIMNEY
BOILER MODEL NO. NO. SEC.
*MBH
*MBH
SIZE/ HEIGHT DIMENSIONS - IN.
WITHOUT TANKLESS
COIL
COIL A B C
BW5BAH091 BW4BAH091 3 91 80 70 0.65 86.3 8-in. x 8-in. x 15 ft 14-1/2 6 8
BW5BAH105 BW4BAH105 3 105 92 80 0.75 85.2 8-in. x 8-in. x 15 ft 14-1/2 6 8
BW5BAH140 BW4BAH140 3 140 119 103 1 83.4 8-in. x 8-in. x 15 ft 14-1/2 6 8
BW5BAH126 BW4BAH126 4 126 111 97 0.9 86.0 8-in. x 8-in. x 15 ft 17-3/4 6 9-5/8
BW5BAH175 BW4BAH175 4 175 150 130 1.25 83.9 8-in. x 8-in. x 15 ft 17-3/4 6 9-5/8
BW5BAH210 BW4BAH210 4 210 178 155 1.5 82.4 8-in. x 8-in. x 15 ft 17-3/4 6 9-5/8
BW5BAH168 BW4BAH168 5 168 147 128 1.2 86.5 8-in. x 8-in. x 15 ft 21 6 11-1/2
BW5BAH245 BW4BAH245 5 245 209 182 1.75 83.6 8-in. x 8-in. x 15 ft 21 6 11-1/2
BW5BAH280 BW4BAH280 5 280 236 205 2 82.0 8-in. x 8-in. x 20 ft 21 6 11-1/2
* MBH = 1,000 BTU per hour / BTU = British Thermal Unit. ** Heating Capacity is based on a 13 percent C02 with a –0.02 in. wc and a #1 smoke or less. Testing was done in accordance with the D.O.E. (Department of Energy) test procedure. +GPH = Gallons per hour oil at 140,000 BTU per gallon. ++A.F.U.E. = Annual Fuel Utilization Efficiency based upon D.O.E. test procedure. As an Energy Star Partner, the manufacturer has determined that this product meets Energy Star guidelines for Energy Efficiency.
36″ · 9″



UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
© 2001 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 PRINTED IN U.S.A Catalog No. 12BS-1A1 3-01