EN
Bryant logo
Official user manual

Bryant ASPCA1BBL040

4 pages·283 KB·Portable Generator·PDF·EN
Bryant ASPCA1BBL040
Table of Contents 32 sections Standby Power Rating 40 kW 60 Hz · Liquid Cooled · Gas Engine Generator Sets · Model Numbers: · … ShowHide
Page 1 of the Bryant ASPCA1BBL040 user manual — FEATURES
Page 1 · click to enlarge
Page 1

Standby Power Rating 40 kW 60 Hz

Liquid Cooled

Gas Engine Generator Sets

Model Numbers:

ASPCS1BBL040 - Steel Enclosure

Bryant ASPCA1BBL040 — Model Numbers: diagram (page 1)
Fig. 1 · Model Numbers:

ASPCA1BBL040 - Aluminum Enclosure

Ultra Quiet Mode

For Low Noise Exercise - 60.0 dB(A) at 7 meters

UL 2200 Listed

3.9GN ENGINE

2 Year Limited Parts and Labor Warranty

Models are equipped with a 200 amp NEMA 3R Transfer Switch with Service Disconnect

STANDARD EQUIPMENT

  • All input connections in one single area
  • High coolant temperature shutdown
  • Low oil pressure shutdown
  • Low coolant level automatic shutdown
  • Overspeed automatic shutdown
  • Crank timer
  • Exercise timer
  • Oil drain extension
  • Cool flow radiator
  • Closed coolant recovery system
  • UV/Ozone resistant hoses
  • Watertight state of the art electrical connectors
  • Mainline circuit breaker
  • Radiator drain extension
  • Battery charge alternator
  • 2 Amp static battery charger
  • Battery cables
  • Battery rack
  • Fan and belt guards
  • Isochronous governor

FEATURES

  • Innovative design and fully prototype tested
  • UL2200 Listed
  • Solid state frequency compensated voltage regulator
  • Dynamic and static battery charger
  • Sound attenuated acoustically designed enclosure
  • Ultra Quiet Mode for low noise level exercise
  • Acoustically designed engine cooling system
  • High flow low noise factory engineered exhaust system
  • State of the art R100 digital control system
  • Watertight electrical connectors
  • Rodent proof construction
  • High efficiency, low distortion designed alternator
  • Vibration isolated from mounting base
  • Matching transfer switches engineered and tested to work as a system
  • All components easily accessible for maintenance
  • Electrostatically applied powder paint

Power Matched · Naturally Aspirated

Page 2 of the Bryant ASPCA1BBL040 user manual — INTERNAL FUNCTIONS:
Page 2 · click to enlarge
Page 2

APPLICATION & ENGINEERING DATA

40 kW

GENERATOR SPECIFICATIONS

ENGINE SPECIFICATIONS

TYPE Synchronous

MAKE Generac

ROTOR INSULATION Class H

MODEL V Type

STATOR INSULATION Class H

CYLINDERS 6

TOTAL HARMONIC DISTORTION ........................................................................<3.5%

DISPLACEMENT 3.9 Liter

TELEPHONE INTERFERENCE FACTOR (TIF) <50

BORE ........................................................................................................................3.91

ALTERNATOR OUTPUT LEADS 3 PHASE 4 wire

BEARINGS Sealed Ball

STROKE 3.31

COUPLING Flexible Disc LOAD CAPACITY (STANDBY RATING) 40 kW

COMPRESSION RATIO 9.1:1

INTAKE AIR SYSTEM Naturally Aspirated

EXCITATION SYSTEM Direct

VALVE SEATS Precision ground

LIFTER TYPE Overhead Valve Push Rod Hydraulic Lifter

GOVERNOR SPECIFICATIONS

TYPE Electronic

FREQUENCY REGULATION Isochronous

VOLTAGE REGULATOR

STEADY STATE REGULATION ± .25%

TYPE Electronic SENSING Single Phase REGULATION ± 1% FEATURES V/F Adjustable

ENGINE LUBRICATION SYSTEM

Adjustable Voltage and Gain

OIL PUMP Gear

OIL FILTER Full flow spin-on cartridge

CRANKCASE CAPACITY 4 Quarts

ENGINE COOLING SYSTEM

GENERATOR FEATURES

TYPE Pressurized Closed Recovery

Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Insulation is Class H rated at 150 °C rise All models are fully prototyped tested

WATER PUMP Belt driven

FAN SPEED 2060 rpm

FAN DIAMETER 22 inches

FAN MODE Pusher

CONTROL PANEL FEATURES

FUEL SYSTEM

SEVEN LED INDICATOR LIGHTS ADDITIONAL FUNCTIONS

  • g nis n e s ytilit U
  • y d a e r m ets y S
  • Low fuel pressure
  • Delay on utility failure for engine start r efs n art e r ofe b p u - m r a w e nig n E
  • yr etta b w o L
  • ytilitu ot r efs n arte r ot y ale D
  • e r u s s e r p lio w o L
  • High coolant temp/low coolant temp
  • Engine cooldown timer te s to n r e sicr e x E
  • d e e p sr e v O
  • Overcrank

FUEL TYPE Natural gas, propane vapor

CARBURETOR Down Draft

SECONDARY FUEL REGULATOR Standard

FUEL SHUT OFF SOLENOID Standard

OPERATING FUEL PRESSURE VAPOR SYSTEMS Nat. Gas 5" to 14" H2O

LP Vapor 5" to 14" H2O

INTERNAL FUNCTIONS:

ELECTRICAL SYSTEM

  • 3 position switch (auto, off and manual)
  • 2 wire start for any transfer switch
  • Communicates with the Generac RTS transfer switch
  • Built-in 7 day exerciser
  • Selectable engine speed at exercise
  • Governor controller is built into the master control board
  • Temperature range -40 ° C to 70 °C

BATTERY CHARGE ALTERNATOR 12V 30 Amp

STATIC BATTERY CHARGER 2 Amp

RECOMMENDED BATTERY Group 24 525CCA

SYSTEM VOLTAGE 12 Volts

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc.

LED Indicators

Page 3 of the Bryant ASPCA1BBL040 user manual — STANDBY 40 kW
Page 3 · click to enlarge
Page 3

STANDBY 40 kW

OPERATING DATA

STANDBY 40 kW KW RATING - LP/NG40/37 ENGINE SIZE3.9 Liter V-6 GENERATOROUTPUTVOLTAGE/KW-60Hz 120/240V,1-phase,1.0pfKW AMP CBSize LP40/NG37 LP167/NG154.2 175 GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase80 FUEL – Natural Gas and LP Vapor Only Fuel consumption – 60Hz N.G.ft.3/hr. LP ft.3 /hr.(gal./hr. - for reference only)Exercise 25% 50% 75% 100% Cycle Load 82 148 285 397 550 33.1 (.90) 59.6 (1.62) 114.8 (3.12) 160 (4.34) 221.5 (6.01) ENGINE COOLING Air flow (inlet air including alternator and combustion air) ft3/min. Coolantcapacity USgal. Heatrejectiontocoolant BTU/hr. Max. operating air temp. on radiator °C (°F) Max. ambient temperature °C (°F)2725 3.0 151,000 60(150) 50(140) COMBUSTION AIR REQUIREMENTS Flowatratedpower60Hz cfm105.4 SOUND EMISSIONS IN DBA Exercisingat7meters Fullloadat7meters60 73 EXHAUST Exhaustflowatratedoutput60Hz cfm Exhaust temp. at muffler outlet °F274.3 938 ENGINE PARAMETERS RatedsynchronousRPM 60Hz HPatratedKW 60Hz1800 LP 64.2 / NG 59 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 °C above - °C 1.65% for every 10 °F above - °F Altitude Deration 1%forevery100mabove-m 3%forevery1000ft.above-ft.25 77 183 600 TRANSFER SWITCH SPECIFICATIONS (If so equipped) No. of Poles CurrentRating (amps) VoltageRating (VAC) Service Disconnect Breaker UtilityVoltageMonitor (fixed) Pick-up Dropout Return to Utility Exerciser 15 minutes weekly UL Listed Enclosure-NEMA3R(Outdoorrated) Dimensions (H”xW”xD”) Weight2 200 250 200 Amp HACR Type 80% 60% 1 minute Standard Standard Standard 23.5x13.05x7.4 50 lbs.

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).

Page 4 of the Bryant ASPCA1BBL040 user manual — SS-ASPCL040-01
Page 4 · click to enlarge
Page 4

STANDBY 40 kW INTERCONNECTIONS

Bryant ASPCA1BBL040 — STANDBY 40 kW INTERCONNECTIONS diagram (page 4)
Fig. 2 · STANDBY 40 kW INTERCONNECTIONS

IF ATS IS USED AS SERVICE ENTRANCE IF ATS IS USED AS SERVICE ENTRANCE DEVICE A BONDING JUMPER WILL NEED DEVICE A BONDING JUMPER WILL NEED TO BE INSTALLED SIZED TO MEET TO BE INSTALLED SIZED TO MEET NATIONAL & LOCAL CODES. NATIONAL & LOCAL CODES.

LICENSED ELECTRICIAN AND MUST MEET ALL NATIONAL, STATE AND LOCAL ELECTRICAL CODES.

CONTROL CONTROL?PANEL PANEL AC?GENERATOR GENERATOR

INSTALLATION LAYOUT

Bryant ASPCA1BBL040 — INSTALLATION LAYOUT diagram (page 4)
Fig. 3
  • BRYANT, INC.
  • 7310 WEST MORRIS STREET
  • INDIANAPOLIS, IN 46231
WEBSITEwww.bryant.com

9.05 All specifications are subject to change without notice.

SS-ASPCL040-01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Bryant ASPCA1BBL040

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bryant ASPCA1BBL040

Be the first to ask — other owners or our team will answer.

Original document

Bryant ASPCA1BBL040 manual PDF

4 pages·283 KB·Portable Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…