EN
Vulcan logo
Official user manual

Vulcan Salamander Broilers (36RB/36IRB)

24 pages·481 KB·Broiler·PDF·ENDEITNLJA
Vulcan Salamander Broilers (36RB/36IRB)
Table of Contents 1 sections SALAMANDER OI Manual (5-21) English ShowHide
Page 1 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — RETAIN THIS MANUAL FOR FUTURE USE
Page 1 · click to enlarge
Page 1

INSTALLATION & OPERATION MANUAL FOR

Salamander Broilers

MODELS

MODELS

36RB 36IRB

C36RB C36IRB

www.vulcanequipment.com

www.wolfequipment.com

Vulcan Salamander Broilers (36RB/36IRB) — MODELS diagram (page 1)
Fig. 1

36RB/36IRB

ITW Food Equipment Group, LLC 3600 N. Point Blvd. Baltimore, MD 21222

RETAIN THIS MANUAL FOR FUTURE USE

F-47200 REV C. (6-21)

Page 2 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — FOR YOUR SAFETY
Page 2 · click to enlarge
Page 2

IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.

IMPORTANT

IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.

IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE.

Page 3 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — INSTALLATION, OPERATION AND CARE OF
Page 3 · click to enlarge
Page 3

INSTALLATION, OPERATION AND CARE OF

SALAMANDER BROILERS

GENERAL

Salamander Broilers are produced with quality workmanship and material. Proper installation, usage, and maintenance of your broiler will result in many years of satisfactory performance.

It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions provided.

Accessories are sold separately for the Salamander Broiler:

Vulcan Salamander Broilers (36RB/36IRB) — INSTALLATION, OPERATION AND CARE OF diagram (page 3)
Fig. 2
Radiant Altitude Kits Accessory NumberDescription ALTISR-N01KIT, RB ALTITUDE NG SEA-1999FT ALTISR-P02KIT, RB ALTITUDE LP SEA-1999FT ALTISR-N03KIT, RB ALTITUDE NG 2000-3999FT ALTISR-P04KIT, RB ALTITUDE LP 2000-3999FT ALTISR-N05KIT, RB ALTITUDE NG 4000-6999FT ALTISR-P06KIT, RB ALTITUDE LP 4000-6999FT ALTISR-N07KIT, RB ALTITUDE NG 7000-8999FT ALTISR-P08KIT, RB ALTITUDE LP 7000-8999FT ALTISR-N09KIT, RB ALTITUDE NG 9000-10000FT ALTISR-P10KIT, RB ALTITUDE LP 9000-10000FT
Vulcan Salamander Broilers (36RB/36IRB) — INSTALLATION, OPERATION AND CARE OF diagram (page 3)
Fig. 3
Common Accessories Accessory NumberDescription WALLMNT-CHRBKRSST WALL MOUNT BRACKETS COUNTER-ADJLEGSET OF (4) 6” ADJUSTABLE LEGS CONNECT-CHALLKIT, SALAMANDER INTERPLUMBING
Page 4 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — LOCATION
Page 4 · click to enlarge
Page 4
Infrared Altitude Kits Accessory NumberDescription ALTISI-N01KIT, RB ALTITUDE NG SEA-1999FT ALTISI-P02KIT, RB ALTITUDE LP SEA-1999FT ALTISI-N03KIT, RB ALTITUDE NG 2000-3999FT ALTISI-P04KIT, RB ALTITUDE LP 2000-3999FT ALTISI-N05KIT, RB ALTITUDE NG 4000-6999FT ALTISI-P06KIT, RB ALTITUDE LP 4000-6999FT ALTISI-N07KIT, RB ALTITUDE NG 7000-8999FT ALTISI-P08KIT, RB ALTITUDE LP 7000-8999FT ALTISI-N09KIT, RB ALTITUDE NG 9000-10000FT ALTISI-P10KIT, RB ALTITUDE LP 9000-10000FT

INSTALLATION

Before installing, verify that the type of gas supply (natural or propane) agrees with the specifications on the rating plate located underneath the broiler rack drip tray. If the supply and equipment requirements do not agree, do not proceed with the installation. Contact your dealer immediately.

UNPACKING

Immediately after unpacking, check for possible shipping damage. If the broiler is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.

Before installing, verify that the type of gas (natural or propane) and the clearance dimensions (see below) agree with the specifications on the rating plate which is located under the crumb tray on the right side.

LOCATION

The equipment area must be kept free and clear of combustible substances.

Minimum Clearance Combustible Construction Non-Combustible Construction Rear 0” 0”

Sides (Infrared) 36IRB & C36IRB 2” 0”

Sides (Radiant) 36RB & C36RB 6” 0”

Bottom 4” with legs 0”

Page 5 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — GAS CONNECTIONS
Page 5 · click to enlarge
Page 5

The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 24" is required.

Do not obstruct the flow of combustion and ventilation air. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room to replace air taken out by the ventilating system. Do not permit fans to blow directly at the broiler. Avoid wall-type fans which create air cross currents within the room. Avoid open windows next to the broiler. Allow for maximum clearance between the flue and hood ventilation system as per NFPA 96 requirements. Minimum 18” clearance is recommended for proper operation and for compliance with local building and fire codes.

INSTALLATION CODES AND STANDARDS

The broiler must be installed in accordance with:

In the United States of America:

In the United States of America: 1. State and local codes. 2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471 NOTE: In the Commonwealth of Massachusetts All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR. 3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1. Local codes. 2. CAN/CSA-B149.1 Natural Gas Installation (latest edition) 3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3

GAS CONNECTIONS

Codes require that a gas shutoff valve be installed in the gas line ahead of the broiler.

NATURAL GAS: Standard orifices are set at 5" W.C. (Water Column). A pressure regulator is supplied and must be installed when the broiler is connected to the gas supply.

PROPANE GAS: Standard orifices are set at 10" W.C. (Water Column). A pressure regulator is supplied and must be installed when the broiler is connected to the gas supply.

Page 6 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — GAS PRESSURE REGULATOR INSTALLATION
Page 6 · click to enlarge
Page 6

The gas supply line must be ¾” or larger. If flexible or semi-rigid connections are used, the inside diameter must be the equivalent of ¾” iron pipe or larger. All connections of the flexible and semi-rigid type must comply with all local and national requirements. Make sure gas piping is clean and free of dirt, piping compound, and obstructions.

After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.

GAS PRESSURE REGULATOR INSTALLATION

Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas, and 10” W.C. for propane gas. Minor adjustments may be required based on site specific gas pressure.

Install the regulator as close to the broiler on the gas supply line as possible. Make sure that the arrow on the underside of the regulator is oriented in the direction of gas flow to the broiler (Fig. 1) and the regulator is positioned with the vent plug and adjustment screw upright (Fig. 2). A recommended plumbing schematic is listed below only for Salamander units as guide to the installer and ITW Cooking Equipment or Hobart is in no way liable for plumbing installation (Fig. 3).

Vulcan Salamander Broilers (36RB/36IRB) — GAS PRESSURE REGULATOR INSTALLATION diagram (page 6)
Fig. 4
Vulcan Salamander Broilers (36RB/36IRB) — GAS PRESSURE REGULATOR INSTALLATION diagram (page 6)
Fig. 5
Vulcan Salamander Broilers (36RB/36IRB) — GAS PRESSURE REGULATOR INSTALLATION diagram (page 6)
Fig. 6
Page 7 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — ASSEMBLY
Page 7 · click to enlarge
Page 7

The minimum supply pressure (upstream of the regulator) should be 7-9” W.C. for natural gas and 11-12” W.C. for propane gas. At no time should the regulator be connected to supply pressure greater than ½ psig (3.45 kPa) or 14” W.C.

FLUE CONNECTIONS

DO NOT obstruct the flow of flue gases from the flue located on the rear of the broiler. It is recommended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel.

Information on the construction and installation of ventilating hoods may be obtained from the standard for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

ASSEMBLY

Salamander Broiler Mounted on a Wall (Fig. 4).

The separate wall mounting bracket accessory (WALLMNT-CHRBKR) will be needed to wall mount the unit.

1. Follow the combustible/noncombustible clearance guidelines that are listed in the “Installation” section in this manual.
2. Make sure brackets are level and properly spaced so that bracket holes will align with the threaded holes on the bottom of the unit to be mounted. The short leg of the bracket with the holes that are nearest the elbow bend is to be placed against the wall. ( Fig. 5 )
3. Secure brackets to wall by means of lag screws or bolts. ( Fig. 5 )
4. Mount the brackets only in the upside-down “L” position as shown. ( Fig. 5 )
5. Make sure the lag bolts or screws engage wall studs. Ensure that the wall construction is of the type that will support the salamander weight.
6. Place the salamander into position on the brackets, making sure that the unit’s bottom threaded attachment points are aligned with the holes in the brackets.( Fig. 6 )
7. Secure unit into position with 3/8” bolts at the bottom of the unit. Thread the bolts through the holes in the brackets and into the threaded attachment points on the bottom of the unit. ( Fig. 6 )
Page 8 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — SALAMANDER OI Manual (5-21) English
Page 8 · click to enlarge
Page 8

Radiant & Infrared Salamander shown on WALLMNT-CHRBKR Accessory

Vulcan Salamander Broilers (36RB/36IRB) — SALAMANDER OI Manual (5-21) English diagram (page 8)
Fig. 7 · SALAMANDER OI Manual (5-21) English
Vulcan Salamander Broilers (36RB/36IRB) — SALAMANDER OI Manual (5-21) English diagram (page 8)
Fig. 8 · SALAMANDER OI Manual (5-21) English
Vulcan Salamander Broilers (36RB/36IRB) — SALAMANDER OI Manual (5-21) English diagram (page 8)
Fig. 9 · SALAMANDER OI Manual (5-21) English

Fig. 5 Fig. 6

Page 9 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — OPERATION
Page 9 · click to enlarge
Page 9

Assembly over a Gas Range (Fig. 7)

If the broiler is to be mounted over a gas range, a reinforced shelf and special mounting brackets are required.

1. Use Instructions from RSHELF Accessory kit to install reinforced shelf over a range.
2. Using the four bolts provided, install mounting brackets on both top corners of

reinforced shelf.

3. Place and align broiler on top of brackets with the back of the unit flush with the rear

of the shelf.

4. Install 3/8-16 Bolts through underside of the RSHELF.

Radiant & Infrared Salamander shown on RSHELF Accessory

Vulcan Salamander Broilers (36RB/36IRB) — SALAMANDER OI Manual (5-21) English diagram (page 9)
Fig. 10 · SALAMANDER OI Manual (5-21) English

OPERATION

Page 10 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — CLEANING
Page 10 · click to enlarge
Page 10

CONTROLS

Dual Zone Controls — Controls cooking areas in the left and right hand side of the cavity

allowing for flexibility and premium cooking performance.

Angled Handle — elevates or lowers the broiling grid to different positions. Grasp the

handle and pull towards broiler cavity. This releases the mechanism and allows the lifting handle to move into the desired position.

Burner Valve — regulates the flow of gas to the burners. Gas flow is increased by

turning the valve counterclockwise.

Drip Tray — Collects grease and waste which is diverted by the tilt of the drip shield.

DO NOT allow the drip tray to overflow. Empty the drip tray when three- quarters full to reduce the possibility of spillage.

Rack Handle — glides the grid forward for easy loading and unloading. To operate, pull

straight out.

LIGHTING, RELIGHTING AND SHUTDOWN INSTRUCTIONS

1. Turn burner valve to the OFF position and wait 5 minutes.
2. Light the pilot adjacent to the main burner. Adjust the pilot valve screw until the pilot flame has a slight yellow tip. There are two pilots to light, on each end of the cooking chamber.
3. After the pilot has been established, turn the burner valve to the ON position. The burner flames may be adjusted, using the air shutters located behind the manifold cover in the front of the range. There are no shutters on the IRB models.
4. If the burners fail to light, turn off all valves, wait 5 minutes and repeat steps 1-3.
5. To shut down, turn the burner valves to the OFF position.

RACK POSITION AND GAS SETTING

Each operator will find the optimum rack position and gas setting for various products; however, it is recommended that gas input be reduced first when lower rack temperatures are desired. Further reduction in rack temperatures, if necessary, can then be obtained by lowering rack position. Infrared Models must use the full gas setting. Max and minimum temperatures can be achieved at the following settings:

2 Burners On, rack at highest position, valves set to High – 800°F

1 Burner On, rack at lowest position, valves set to Low – 250°F

CLEANING

1. Allow broiler to cool.
2. To remove broiler rack for cleaning, adjust broiler rack to center position.
Page 11 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — SERVICE AND PARTS INFORMATION
Page 11 · click to enlarge
Page 11
3. Position left and right hands simultaneously on edges of broiler rack and raise both

rack stops.

4. Slide broiler rack and drip tray forward past rack stops, (which must be pivoted out

of the way) holding tray up against racks.

5. Remove broiler rack and drip tray from broiler.
6. Let back of tray drop down to vertical to allow front hooks to disengage.
7. Remove drip pan from broiler rack and clean as you would any normal utensil, using

care not to damage the front hooks

8. To replace, hook the drip tray to the broiler rack while tray is in a vertical position.
9. Replace broiler rack and drip tray in side channels while holding tray up close to

rack.

10. Clean bottom pan. Slide pan out and wash with soap and water. Rinse thoroughly

and wipe dry with a soft clean cloth.

11. Clean stainless steel surfaces with a mild detergent and water, using a damp cloth,

or with a commercial stainless steel cleaner. Rinse thoroughly and wipe dry with a soft clean cloth.

12. Burner ports and throats should be thoroughly cleaned. Venturi must be free from

grease and lint. DO NOT insert pick in burner port holes.

MAINTENANCE

LUBRICATION

Burner valve stems must be lubricated. Upon sticking, a burner valve stem should receive maintenance from your local authorized servicer.

PILOT LIGHTS

Pilot lights are to be kept clean and adjusted at the proper flame height.

VENT

Annually, when the broiler is cool, check the flue and clear any obstructions.

SERVICE AND PARTS INFORMATION

Contact your local Service Agency to obtain service and parts information.

Page 12 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — NOTES
Page 12 · click to enlarge
Page 12

NOTES

PRINTED IN THE U.S.A.

Page 13 of the Vulcan Salamander Broilers (36RB/36IRB) user manual — NOTES
Page 13 · click to enlarge
Page 13

PRINTED IN THE U.S.A.

NOTES

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Vulcan Salamander Broilers (36RB/36IRB)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Vulcan Salamander Broilers (36RB/36IRB)

Be the first to ask — other owners or our team will answer.

Original document

Vulcan Salamander Broilers (36RB/36IRB) manual PDF

24 pages·481 KB·Broiler·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…