677B EVOLUTIONt14 SEER SINGLE--PACKAGED HYBRID HEATt SYSTEM WITH PURON® (R--410A) REFRIGERANT

User’s Information Manual

A06047 Fig. 1 -- Unit 677B

NOTE TO EQUIPMENT OWNER:

For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.

UNIT INFORMATION

INSTALLATION INFORMATION

DEALERSHIP CONTACT INFORMATION

ACCESSORIES (List type and model #)

Show 11 more labels / short text on this page
Model # _____________________________________ · Date Installed ________________________________ · Serial # ______________________________________ · Company Name_______________________________ · Address______________________________________ · _____________________________________________ · _____________________________________________ · Phone Number _______________________________ · _____________________________________________ · Technician Name _____________________________ · _____________________________________________
Page 2 of the Bryant Packaged Air Conditioner (677B) user manual — ! WARNING
Page 2 · click to enlarge
Page 2

SAFETY CONSIDERATIONS

UNIT INTRODUCTION

This 677B unit is a small packaged Hybrid Heatt system that can utilize both the efficiency of heat pump heating and the comfort of gas heating. The system will optimize for ideal heating, depending on several factors.This unit uses Puron®,the ozone friendlyrefrig- erant, for cooling and heat pump heating.

Installation and servicing of this equipment can be hazardous due to mechanical and electrical components. Only trained and qualified personnel should install, repair, or service this equipment.

Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on this equipment, observe precautions in the literature, on tags, and on la- bels attached to or shippedwith theunit andother safetyprecautions that may apply.

You may notice your two--stage packaged Hybrid Heatt system runs for longer periods of time. Nearly 80% of the time it’s running, it is operating in low--stage, and your indoor temperature will remain more consistent with fewer drafts, better humidity control, enhanced comfort and enhanced energy efficiency.

Follow all safety codes. Installation must be in compliance with lo- cal and national building codes. Wear safety glasses, protective clothing, and work gloves. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit.

WARNING !

FIRE, EXPLOSION HAZARD

Failure to follow this warning could result in death, personal injury and/or property damage.

Recognize safety information. This is the safety--alert symbol

. Whenyouseethissymbolontheunitandininstructions ormanuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety--alert symbol. DANGER identifies the most se- rious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in en- hanced installation, reliability, or operation.

Do not attempt to light by hand.

! WARNING

FIRE, EXPLISION, ELECTRICAL SHOCK HAZARD

Failure to follow this hazard warning could result in personal injury, death and/or property damage.

1. Do not turn off the electrical power to unit without first turning off the gas supply.
2. Before attempting to start the gas heating section, familiarize yourself with all the procedures that must be followed.

CAUTION !

Starting or Shutting Off Unit

To start the unit:

FOR YOUR SAFETY

1. Turn on the electrical power supply to unit.

Failure to follow this caution may result in personal injury.

2. Turn on the gas supply to unit.
3. Select temperature and set User Interface (UI) control to desired mode.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

To shut off unit: Note: If the unit is being shut down because of a malfunction, call your dealer as soon as possible.

1. Set UI control to OFF.

! WARNING

2. Turn off gas supply to unit.

FIRE,EXPLOSION,ELECTRICAL SHOCKHAZARD

3. Turn off electrical power supply to unit.

OPERATING YOUR UNIT

Failure to follow this warning could result in personal injury, death or property damage.

The operation of your unit is controlled by the Evolutiont UI. You simplyprogramtheUIandit maintainsthe indoortemperature atthe level you select. See UI manual for detailed instructions.

Do not use this unit if any part has been underwater. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system which has been underwater.

To better protect your investment and to eliminate unnecessary ser- vice calls, familiarize yourself with the following facts:

With the SYSTEM control set to COOL, your unit will run in cool- ing mode until the indoor temperature is lowered to the level you have selected. On extremely hot days, your unit will run for longer periods at a time and have shorter “off” periods than on moderate days.

! WARNING

For your safety if you smell gas:

1. Do not try to light any appliance.

Step 2—Hybrid Heating Mode

2. Do not touch any electrical switch; do not use any phone in your building.

Your Hybrid Heat system combines the strengths of two heating sources; an electric heat pump and a gas furnace. A Hybrid Heat system provides more control over your monthly energy bills by al- lowing you to choose the most economical method of heating. As conditions change, the system automatically switches between the two sources to maintain greater efficiency than with a single--source heating system.

3. Immediately call your gas supplier from a nearby phone. Follow the gas supplier’s instructions.
4. If you cannot reach your gas supplier, call the fire department.

Step 1—Cooling Mode

Page 3 of the Bryant Packaged Air Conditioner (677B) user manual — ACCESS PANEL
Page 3 · click to enlarge
Page 3

With the UI control set to HEAT, your unit will normally operatethe electric heat pump until the room temperature is raised to the level you have selected. If the demand for heat cannot be met by the elec- tric heatpump, yourUI controlwill automaticallyswitch togas heat until the call for heat is satisfied.

Table 1—Indoor Air Filter Data

Unit SizeFilter Size 677B024---03020x24x1 677B03624x30x1 677B042---06024x36x1

On colder days, your system may automatically switch to gas heat as the primary heating source to maximize the overall system effi- ciency and maintain your comfort level.

To replace or inspect filters in accessory filter rack (See Fig. 2):

1. Remove the filter access panel using a 5/16--in. nut driver.

MAINTENANCE AND SERVICE

2. Removethefilter(s)bypullingitoutoftheunit.If thefilter(s) is dirty, clean or replace with a new one.

This section discusses maintenance that should be performed on your system. Most maintenance should be performed by your deal- er. You, as the owner, may wish to handle some minor maintenance for your new unit.

When installing the new filter(s), note thedirection ofthe airflowar- rows on the filter frame.

If you have difficulty locating your air filter(s) or have questions concerning proper filter maintenance, contact your dealer for in- structions. When replacing filters, always use the same size andtype of filter that was supplied originally by the installer.

All routine maintenance should be handled by skilled, experienced personnel. Your dealer can help you establish a standard procedure.

To assure proper functioning of the unit, flow of condenser air must not be obstructed from reaching the unit. Clearance from the top of the unit is 48 in. Clearance of at least 36 in. is required on sides ex- cept the power entry side (42 in. clearance) and the duct side (12 in. minimum clearance).

! WARNING

FIRE AND UNIT OPERATION HAZARD

Maintenance and Care for the Equipment Owner

Failure to follow this warning could result in personal injury, death or property damage.

Before proceeding with those things you might want to maintain yourself, please carefully consider the following:

Never operate your unit without filters in place. An accumulation of dust and lint on internal parts ofyour unit can cause loss of efficiency.

! WARNING

FIRE,EXPLOSION,ELECTRICAL SHOCKHAZARD

Failure to follow this warning could result in personal injury, death or property damage.

BEFORE SERVICING OR PERFORMING MAINTENANCE ON YOUR UNIT:

1. TURN OFF GAS SUPPLY TO YOUR UNIT.
2. TURN OFF ELECTRICAL POWER TO YOUR UNIT.

WARNING !

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in death, personal injury and/or property damage.

When removing access panels or performing maintenance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be extremely careful when handling parts or reaching into the unit.

ACCESS PANEL

FILTER ACCESS PANEL*

*For accessory filter rack A06116 Fig. 2 -- Accessory Filter Rack Access Panel

Fans and Fan Motors

The air filter(s) should be checked every 3 or 4 weeks and changed or cleaned whenever it becomes dirty. Dirty filters produce exces- sive stress on the blower motor and can cause the motor to overheat and shut down.

Periodically check the condition of fanwheels andhousings andfan motor shaft bearings. Contact your dealer for the required annual maintenance.

Indoor and Outdoor Coils

This unit must have air filters in place before it can be operated. These filters can be located in one of at least two places. In many ap- plications, the installer will provide return air filter grilles mounted on the wall or ceiling of the conditioned structure. In the instance of filter grilles, the filters can simply be removed from the grille andre- placed.

Cleaning of the coils should only be done by qualified service per- sonnel. Contact your dealer for the required annual maintenance.

The drain pan and condensate drain line should be checked and cleaned at the same time the cooling coils are checked by your deal- er.

The other typical application is an accessory filter rack installed in- side the unit itself. The following information is given to assist in changing filters used in these internal filter racks.

All compressors arefactory shippedwith anormal chargeof thecor- rect type of refrigeration grade oil. A compressor should rarely re- quire additional oil.

Table 1 indicates the correct filter size for your unit. Refer to Fig. 2 to access filters installed in the accessory filter rack.

Show 4 more labels / short text on this page
Routine Maintenance · Air Filters · Condensate Drain · Compressor
Page 4 of the Bryant Packaged Air Conditioner (677B) user manual — EXPLOSION AND BURN HAZARD
Page 4 · click to enlarge
Page 4
3. Inspection and cleaning of blower wheelhousing andmotor.
4. Inspection of all supply--air and return--air ducts for leaks, obstructions, and insulation integrity. Any problems found should be resolved at this time.

! WARNING

5. Inspectionof theunit baseto ensurethat nocracks, gaps,etc., exist which may cause a hazardous condition.

PERSONAL INJURY AND UNIT DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death or property damage.

6. Inspection of the unit casing for signs of deterioration.
7. Inspection of all electrical wiring and components to assure proper connection.

Do not insert sticks, screwdrivers, or any other objects into revolving fan blades.

8. Inspection for leaks in the refrigerant circuit. Pressure check to determine appropriate refrigerant charge.

The fan must be kept free of all obstructions to ensure proper cool- ing. Contact your dealer for any required service.

9. Inspection of compressor oil level by service person to ensure proper oil level is maintained in the compressor when it is installed and running.

Electrical Controls and Wiring

Electrical controlsare difficultto checkwithout properinstrumenta- tion. If there are any discrepancies in the operating cycle, contact your local dealer and request service.

10. Operational check of the unit to determine working conditions.Repairoradjustmentshouldbe madeat thistime.

Your servicing dealer may offer an economical service contract that covers seasonal inspections. Ask for further details.

Therefrigerantcircuitisdifficulttocheckforleakswithout theprop- er equipment. If inadequate cooling is suspected, contact your local dealer for service.

Complete service instructions can be found in the unit Installation, Start--up and Service Instructions.

Your unit has a limited warranty. Be sure to read the warranty care- fully to determine the coverage for your unit.

! WARNING

Before you call for service...

EXPLOSION AND BURN HAZARD

...check for several easily--solved problems.

Failure to follow this warning could result in personal injury, death or property damage.

If insufficient heating or cooling is suspected:

System under pressure. Relieve pressure and recover all refrigerant before system repair or final unit disposal. Use all service ports and open all flow--control devices, including solenoid valves.

( ) Check for sufficient airflow. Check the air filter for dirt. Check for blocked return--air or supply--air grilles. Be sure they are open and unobstructed. If these checks do not reveal the cause, call your servicing dealer.

If your unit is not operating at all, check the following list for easy solutions:

After performing any maintenance or service on the unit, be sure all panels are fastened securely in place to prevent rain from entering unit cabinet and to prevent disruption of the correct unit airflow pat- tern.

( ) Check to be sure that the temperature specified by your User Interface is set below the indoor temperature during the cooling sea- son or above the indoor temperature during heating season. Be sure the User Interface is set to COOL or HEAT and not OFF.

( ) If your unit still fails to operate, call your servicing dealer for troubleshooting and repairs. Specify the model and serial numbers of your unit. (Record them in this manual in the space provided.) If the dealer knows exactly which unit you have, he may be able to offer suggestions over the phone, or save valuable time through knowledgeable preparation for the service call.

In addition to the type of routine maintenance you might be willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection (preferably each year, but at least every other year) should include the following:

1. Inspection and, if required, cleaning of the outdoor and indoor coils.

In Case of Trouble

2. Inspection and, if required, cleaning of the indoor coil drain pan.

If you perform the steps above and unit performance is still unsatis- factory, shut off the unit and call your dealer.

Heating & Cooling Systems

TO OBTAIN INFORMATION ON PARTSConsult your installing dealer or classified section of your local telephone directory under the

“Heating Equipment” or “Air Conditioning Contractors & Systems” heading for dealer listing by brand name. Have available the Model No., Series Letter, & Serial No. of your equipment to ensure correct replacement part.

E2006 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231

Printed in the U.S.A. Edition Date: 07/06 Catalog No: OM01---76

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

ReplacesNew
Show 5 more labels / short text on this page
Condenser Fan · Refrigerant Circuit · Warranty Certificate · Unit Panels · Regular Dealer Maintenance

Ask about the Bryant Packaged Air Conditioner (677B)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bryant Packaged Air Conditioner (677B)

Be the first to ask — other owners or our team will answer.

Original document

Bryant Packaged Air Conditioner (677B) manual PDF

4 pages·254 KB·Electric Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…