650A (60 Hz)
Sizes 024 thru 060
wire dome top results in quieter and more efficient operation.
provide a slower fan operation, thus reducing noise and improving efficiency.
muffles noise from operation.
minimizes low frequency sound and pressure pulsation generated by compressor discharge gas.
—Steel is galvanized and coated with a layer of zinc phosphate. A layer of modified polyester powder is then applied and baked on, providing each unit with a durable finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rust-resistant, quality appearance.
—The DuraGuard coil protector, made of a 12 gage coated steel wire grid with vertical 3/8-in. spacing, is designed to help protect the coil from inclement weather, van- dalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning.
—One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil.
The Quantum Plus line of split-system outdoor units has been expanded to include the Model 650A 13 SEER heat pump (with efficiencies up to 14.5 SEER). Homeowners will appreci- ate the Quantum Plus with Puron Refrigerant because of its efficiency, environmental soundness and its availability for years to come. Another benefit of the Quantum Plus is the durability of the scroll compressor. Model 650A has received certifications from UL, c-UL, ARI, CEC, and CSA-EEV. The 650A is also approved by Energy Star
—Available in 6 nominal sizes from 024 through 060 to meet the needs of residential and light commercial applications.
—Standard 1-year limited warranty on parts, with an additional 9-year limited warranty on compressor.
—Means greater reli- ability under adverse weather conditions and dependable performance for many years. Permanent split-capacitor-type motors provide more economical operation.
for energy efficiency and by Green Seal for efficiency and environmental soundness.
FEATURES
REFRIGERANT
—The environmentally sound refrigerant used in the 650A is Puron. This advanced refrigerant con- tains no chlorine which can contribute to ozone depletion in the atmosphere, so it’s a smart choice for homeowners who are concerned with protecting our environment, now and for future generations. And it’s a smart choice for anyone inter- ested in high-efficiency cooling.
—Incorporates a built-in 5-minute compressor time-delay relay, defrost relay, defrost timer, and low-voltage terminal board. The defrost control is a time/temperature initiation/termination control, which includes 3 field-selectable time periods of 30, 50, and 90 minutes.
—Due to PressureGuard™ the 650A can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. The 650A can be installed on a roof or at ground level on a slab.
—All units include a suction line accumulator that minimizes the amount of liquid refrigerant that reaches the compressor; a high-pressure switch for high-pressure protection; a low-pressure switch for loss of charge protection; and a liquid-line filter drier to remove any moisture or foreign matter from the system. A crankcase heater is standard on the 048 and 060 sizes.
—Both service valves are brass, back seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures.
—Each scroll compressor motor is protected with internal temperature and current- sensitive overloads. For improved serviceability each com- pressor is equipped with a compressor terminal plug.
—This unit must be installed with a Puron™ approved TXV on the indoor coil. The FX4 and FV4 fan coils come factory equipped with Puron TXVs. When installed with these fan coils, no further change is required. For any other coil combination, the approved field accessory Puron TXV must be installed. For applications with fan coils such as the FC4 and FK4 which have R-22 TXVs, the R-22 TXV must be replaced with the approved field accessory Puron TXV.
—Copper tube, enhanced aluminum fin coil is designed for strong heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan is popular for its easy removal of water, dirt, and leaves. The
consists of 4 design features to achieve ultra-low sound ratings.
ELECTRICAL RANGE
—All units are offered in 208/230v single phase only.
featuring the Aeromax opening and


FIELD POWER SUPPLY CONN 7/8 IN. DIA (22.22)
HOLE WITH 1 1/8 IN. DIA (34.92) KNOCKOUT
Minimum outdoor operating ambient in cooling mode is 55°F (unless low ambient control is used) max 125°F. 2. Maximum outdoor operating ambient in heating mode is 66°F. 3. Series designation is the 14th position of the unit model number. 4. Center of gravity . 5.
3/8 IN. DIA (9.5) TIEDOWN KNOCKOUTS (2) PLACES IN BASEPAN


* RST—Refrigeration Service Tubing, standard refrigerant grade tubing.

* TXV must be installed when indoor coil is not equipped with a Puron approved TXV. TXV listed is for any approved coil combination. All TXVs are Puron spe- cific bi-flow hard shutoff.

024-A,C 72 030-A,C 74 036-A,C 76 042-A,C 76 048-A,C 78 060-B,C 78
As an ENERGY STAR
partner, Bryant Heating & Cooling Systems has determined that this prod- uct meets the ENERGY STAR guidelines for energy efficiency.
Meets GREEN SEAL Environmental Criteria for high energy efficiency, low noise, and recycled packaging. Does not use an ozone depleting substance during manufacturing, or as a refrigerant.
D
T
O
E
R
T
F
A
R
A
S

E
R
A
R
O
M
T
U
T
A
R
Y
O
N
D
P
Y
F
A
U
N
T
O
N
N
G
A
N
U
N
G
W
M
H
T
A
E
Q
U
P
M
E
N
T
R
S
T
A
A
R
D
N
D
CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM
REGISTERED QUALITY SYSTEM
IS LISTED WITH ARI.


* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure. † If other than uncoated (non-plated), 60°C or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than
10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. ‡ Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 percent. ** Time-delay fuse or circuit breaker. †† The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, refer to the Residential Split-Systems Long-Line
Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using Puron (R-410A). ‡‡ Outdoor thermostat required. *** For indicator function, thermostat specified must be used and wired according to service alarm Installation Instructions. ††† Use with low-ambient pressure switch.
Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.

* Do not use in zoning heat pump applications. † This plate is designed to cover surrounding wall area located behind thermostat. ‡ Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used
to replace a broken thermostat wire, or add an extra wire when needed. ** Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version and builder’s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor
used with the dual fuel thermostat. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.
* For tubing line sets between 50 and 175 ft and/or 20 ft elevation difference between indoor and outdoor units, refer to the Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using Puron Refrigerant. † Required for all applications.
must be

Compressor Start Assist—Capacitor and Relay
Start capacitor and start relay which gives a “hard” boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.
Installations where outdoor design temperature exceeds 105°F (40.6°C). Units installed with Low Ambient Pressure Switch. Units installed with Liquid-Line Solenoid Valve. 2.
Compressor Start Assist—PTC Type
Solid-state electrical device which gives a “soft” boost to the compressor at each start-up. SUGGESTED USE: Installations with marginal power supply.
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. (Use with Low-Ambient Pressure Switch.) All commercial installations. 4.
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units to which Low-Ambient Pressure Switch has been added.
A device for removing contaminants from refrigerant circulating in a heat pump system; 2-direction flow for heat pumps. SUGGESTED USE: Split-system heat pumps.
Interface Control (Energy Minder)
An electric control for controlling a heat pump and gas or oil furnace system for maximum energy savings. It allows heat pump to operate down to a predetermined economic balance point temperature, then switches to allow furnace operation only below that temperature. Requires outdoor thermostat (Item 11) to be adjusted for economic balance point temperature. SUGGESTED USE: For heat pump and gas- or oil-fired furnace combination systems unless Duel Fuel Thermostat or Thermidistat™ Control is used.
An SPDT relay which switches the Low-Ambient Controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. SUGGESTED USE: All heat pumps where Low-Ambient Pressure Switch has been added.
Liquid-Line Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor unit which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. SUGGESTED USE: In long-line applications. (Refer to the Residential Split-System Long-Line Application Guideline and Service Manual.)
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at low-ambient temperatures down to 0°F (–17.8°C) when properly installed. SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C). 10.
Outdoor Air Temperature Sensor
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat. SUGGESTED USE: All Bryant programmable thermostats. 11.
An SPDT temperature actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below set point. SUGGESTED USE: Heat pump installations with multiple-stage supplemental heaters. 12.
An SPDT temperature actuated switch which turns on a third stage of supplemental electric heaters when outdoor air temperature drops below the second-stage set point. SUGGESTED USE: Heat pump installations where 3-stage operation of supplemental heaters is desired. 13.
A current-sensing lockout relay which provides immediate notification that compressor is not operating during a call for heating or cooling. Used with proper room thermostat, a thermostat signal is turned on signifying service is required. This can minimize electrical cost increase due to operation of supplemental heaters only. SUGGESTED USE: As a feature to notify owner immediately when the system is not operating most efficiently. 14.
Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base. SUGGESTED USE: Heat pump installations in heavy snowfall areas.
Heat pump installations in snowdrift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 15.
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base; minimizes corrosion. SUGGESTED USE: Coastal installations.
Windy areas or where debris is normally circulating. Rooftop installations. 16.
Thermostatic Expansion Valve (TXV)—Bi-Flow
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. SUGGESTED USE: Required for all installations. 17.
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. (Refer to ARI Unitary Directory.)
Required for use on all zoning systems.


* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard:
80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard:
70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit. † Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps. ‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type. ** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD. †† Indoor Airflow
Low-Temp Heating Standard:
— Coefficient of Performance
— Energy Efficiency Ratio
— Heating Seasonal Performance Factor
— Seasonal Energy Efficiency Ratio
— Total Capacity (Btuh)
TXV
— Thermostatic Expansion Valve
— Time-Delay Relay


80 70 60 50 40 30 20 10 0 -10
BASED ON INDOOR ENT. AIR AT 70˚F AND AT RATED CFM



CONDENSER ENTERING AIR TEMPERATURES °F 75 85 95 105 115 125
Sys Kw** Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
650AN042-A,C Outdoor Section With FV4ANF003 Indoor Section
72 48.5 24.4 2.95 46.4 23.6 3.32 44.1 22.8 3.72 41.7 21.9 4.17 39.0 21.0 4.65 36.1 20.0 5.17 67 44.6 30.9 2.91 42.6 30.1 3.28 40.5 29.2 3.68 38.3 28.3 4.12 35.8 27.4 4.61 33.2 26.3 5.12 63†† 41.7 30.1 2.89 39.8 29.3 3.25 37.8 28.4 3.65 35.7 27.5 4.09 33.4 26.5 4.57 31.0 25.5 5.09 62 41.0 37.2 2.88 39.2 36.3 3.24 37.3 35.3 3.65 35.3 34.3 4.09 33.2 33.0 4.57 31.1 31.1 5.09 57 39.7 39.7 2.87 38.2 38.2 3.24 36.7 36.7 3.64 35.0 35.0 4.08 33.1 33.1 4.57 31.1 31.1 5.09
72 49.4 25.6 2.99 47.1 24.8 3.36 44.8 23.9 3.77 42.2 23.1 4.22 39.5 22.1 4.70 36.5 21.1 5.22 67 45.4 32.9 2.96 43.3 32.0 3.32 41.2 31.2 3.73 38.8 30.2 4.17 36.3 29.3 4.65 33.6 28.2 5.17 63†† 42.5 32.0 2.93 40.5 31.1 3.30 38.4 30.2 3.70 36.2 29.3 4.14 33.9 28.3 4.62 31.3 27.2 5.14 62 41.9 39.7 2.93 40.0 38.7 3.29 38.2 37.6 3.70 36.2 36.2 4.14 34.2 34.2 4.62 32.0 32.0 5.15 57 41.2 41.2 2.92 39.6 39.6 3.29 37.9 37.9 3.69 36.1 36.1 4.14 34.2 34.2 4.62 32.0 32.0 5.15
Cooling Capacity Power Capacity Power
F(A,B)4AN(F,B,C) 048 0.99 1.07 CJ5A/CK5A/CK5BA 048 0.99 1.08
FC4BN(F,B) 048 1.00 1.09 CJ5A/CK5A/CK5BN 048 0.99 1.08
FK4CNF 003 1.00 1.00 CJ5A/CK5A/CK5BW 048 0.99 1.08
005 1.01 0.98 CK3BA 048 0.99 1.08
FV4ANF 005 1.01 0.98 — — —
FX4ANF 042 1.00 1.09
650AN048-A,C Outdoor Section With FV4ANF005 Indoor Section
72 54.7 27.7 3.20 52.2 26.8 3.56 49.6 25.9 3.96 46.9 24.9 4.41 43.9 23.9 4.90 40.7 22.8 5.43 67 50.2 35.2 3.16 47.9 34.3 3.52 45.5 33.3 3.92 43.0 32.3 4.36 40.3 31.3 4.85 37.4 30.1 5.39 63†† 46.8 34.3 3.13 44.7 33.3 3.49 42.4 32.4 3.89 40.1 31.3 4.33 37.6 30.3 4.82 34.9 29.1 5.36 62 46.1 42.5 3.12 44.0 41.5 3.48 42.0 40.5 3.88 39.7 39.3 4.33 37.5 37.5 4.82 35.2 35.2 5.37 57 44.9 44.9 3.11 43.2 43.2 3.47 41.4 41.4 3.88 39.6 39.6 4.33 37.5 37.5 4.82 35.2 35.2 5.37
72 55.6 29.1 3.26 53.0 28.1 3.62 50.3 27.2 4.02 47.4 26.2 4.47 44.4 25.2 4.96 41.1 24.1 5.49 67 51.1 37.5 3.22 48.7 36.6 3.58 46.2 35.6 3.98 43.6 34.6 4.42 40.8 33.5 4.91 37.8 32.3 5.45 63†† 47.7 36.5 3.19 45.4 35.5 3.55 43.1 34.5 3.95 40.7 33.5 4.39 38.1 32.4 4.88 35.3 31.2 5.42 62 47.1 45.5 3.18 45.1 44.4 3.54 42.9 42.9 3.95 41.0 41.0 4.39 38.8 38.8 4.89 36.3 36.3 5.43 57 46.7 46.7 3.18 44.8 44.8 3.54 42.9 42.9 3.94 40.9 40.9 4.39 38.8 38.8 4.89 36.4 36.4 5.43
Cooling Capacity Power Capacity Power
F(A,B)4AN(F,B,C) 060 0.98 1.10 FX4ANB 060 1.00 1.06
FB4ANB 070 1.01 1.06 CE3AA 060 1.00 1.06
FC4BN(F,B) 060 0.98 1.10 CJ5A/CK5A/CK5BA 060 0.99 1.06
FC4BNB 070 1.01 1.06 CJ5A/CK5A/CK5BN 060 1.00 1.06
FK4CNB 006 1.02 0.98 CJ5A/CK5A/CK5BX 060 1.00 1.06
FK4CNF 005 1.00 1.00 CK3BA 060 0.99 1.06
FV4ANB 006 1.02 0.98 — — —

CONDENSER ENTERING AIR TEMPERATURES °F 75 85 95 105 115 125
Sys Kw** Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
650AN060-B,C Outdoor Section With FV4ANB006 Indoor Section
72 70.1 35.6 4.43 66.6 34.4 4.92 63.1 33.1 5.47 59.2 31.7 6.07 55.0 30.3 6.73 50.2 28.7 7.42 67 64.4 45.5 4.35 61.3 44.2 4.85 58.0 42.9 5.40 54.5 41.5 6.00 50.6 40.0 6.65 46.4 38.4 7.35 63†† 60.2 44.3 4.30 57.2 43.0 4.79 54.2 41.7 5.34 50.9 40.3 5.94 47.3 38.8 6.60 43.4 37.1 7.30 62 59.2 55.1 4.29 56.4 53.7 4.78 53.5 52.3 5.33 50.5 50.4 5.93 47.5 47.5 6.60 44.2 44.2 7.32 57 57.8 57.8 4.27 55.6 55.6 4.77 53.1 53.1 5.32 50.5 50.5 5.93 47.5 47.5 6.60 44.2 44.2 7.32
72 71.1 37.4 4.52 67.6 36.1 5.02 63.9 34.8 5.57 59.8 33.4 6.16 55.5 32.0 6.81 50.6 30.4 7.51 67 65.5 48.5 4.44 62.2 47.2 4.94 58.8 45.9 5.49 55.1 44.4 6.09 51.1 42.9 6.74 46.8 41.2 7.44 63†† 61.2 47.1 4.39 58.1 45.8 4.88 54.9 44.4 5.43 51.6 43.0 6.03 47.9 41.5 6.68 43.8 39.7 7.39 62 60.5 59.0 4.38 57.7 57.4 4.88 54.9 54.9 5.43 52.1 52.1 6.04 48.9 48.9 6.70 45.3 45.3 7.42 57 60.1 60.1 4.38 57.6 57.6 4.88 54.9 54.9 5.43 52.1 52.1 6.04 49.0 49.0 6.70 45.4 45.4 7.42
Cooling Capacity Power Capacity Power
FB4ANB 070 0.98 1.04 CC5A/CD5AW 060 0.97 0.99
FC4BNB 070 0.98 1.04 CJ5A/CK5A/CK5BX 060 0.97 1.00
FK4CNB 006 1.00 1.00 — — —
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. † Total and sensible capacities are net capacities. Blower motor heat has been subtracted. ‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80°F (27°C). ** System kw is total of indoor and outdoor unit kilowatts. †† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb. EWB—Entering Wet Bulb

OUTDOOR COIL ENTERING AIR TEMPERATURES °F –3 7 17 27 37 47 57 67
Pwr Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†
650AN024-A,C Outdoor Section With FX4ANF030 Indoor Section
65 700 12.0 11.1 1.79 14.3 13.1 1.87 16.6 15.1 1.95 19.0 16.9 2.04 21.9 19.9 2.16 25.0 25.0 2.30 28.5 28.5 2.48 32.6 32.6 2.74 800 12.2 11.2 1.80 14.5 13.3 1.87 16.8 15.3 1.95 19.2 17.1 2.03 22.1 20.1 2.13 25.4 25.4 2.27 28.9 28.9 2.44 33.1 33.1 2.69 900 12.4 11.4 1.82 14.6 13.4 1.88 17.0 15.5 1.95 19.4 17.3 2.03 22.4 20.4 2.13 25.6 25.6 2.25 29.3 29.3 2.43 33.4 33.4 2.67
70 700 11.8 10.8 1.87 14.1 13.0 1.96 16.4 15.0 2.05 18.8 16.7 2.14 21.6 19.6 2.26 24.7 24.7 2.41 28.1 28.1 2.60 32.0 32.0 2.87 800 12.0 11.0 1.88 14.3 13.1 1.96 16.6 15.1 2.04 19.0 16.9 2.13 21.8 19.9 2.24 25.0 25.0 2.38 28.5 28.5 2.56 32.5 32.5 2.81 900 12.1 11.2 1.90 14.4 13.3 1.97 16.8 15.3 2.05 19.2 17.0 2.13 22.1 20.1 2.23 25.3 25.3 2.36 28.8 28.8 2.54 32.9 32.9 2.79
Cooling Capacity Power Capacity Power
F(A,B)4AN(F,C) 030 0.98 1.01 036 0.98 1.01
FC4BNF 030 0.98 1.01 CJ5A/CK5A/CK5BA 030 0.98 1.01
FK4CNF 001 0.95 0.95 036 0.99 0.98
002 1.00 0.92 CJ5A/CK5A/CK5BN 036 0.99 0.98
003 1.01 0.94 CJ5A/CK5A/CK5BW 030 0.98 1.01
FV4ANF 002 1.01 0.97 036 0.99 0.98
003 1.00 0.96 CK3BA 030 0.98 1.01
— — — 036 0.99 0.98
65 825 12.6 11.6 2.07 15.4 14.1 2.12 18.3 16.7 2.16 21.6 19.2 2.22 25.4 23.1 2.29 29.7 29.7 2.39 34.6 34.6 2.69 32.7 32.7 2.55 1050 12.9 11.9 2.11 15.7 14.4 2.14 18.7 17.0 2.17 22.0 19.6 2.21 25.9 23.6 2.27 30.4 30.4 2.35 35.4 35.4 2.63 33.5 33.5 2.49 1250 13.2 12.2 2.15 16.0 14.7 2.17 19.0 17.3 2.19 22.4 19.9 2.23 26.3 23.9 2.28 30.8 30.8 2.36 36.0 36.0 2.64 33.9 33.9 2.49
70 825 12.3 11.3 2.18 15.2 14.0 2.23 18.1 16.5 2.28 21.4 19.0 2.33 25.1 22.8 2.41 29.4 29.4 2.52 34.1 34.1 2.82 32.2 32.2 2.67 1050 12.7 11.7 2.21 15.6 14.3 2.25 18.5 16.9 2.28 21.8 19.4 2.32 25.6 23.3 2.38 30.0 30.0 2.47 34.9 34.9 2.76 33.0 33.0 2.60 1250 13.0 11.9 2.25 15.8 14.5 2.28 18.8 17.1 2.30 22.1 19.6 2.34 26.0 23.6 2.39 30.4 30.4 2.47 35.4 35.4 2.76 33.4 33.4 2.60
Cooling Capacity Power Capacity Power
F(A,B)4AN(F,C) 030 0.98 1.02 003 0.95 0.92
036 0.99 1.03 FX4ANF 036 1.00 1.01
FC4BNF 030 0.98 1.02 CE3AA 036 0.97 1.01
036 0.99 1.03 CJ5A/CK5A/CK5BN 036 0.98 0.99
FK4CNF 001 0.95 0.96 CJ5A/CK5A/CK5BW 036 0.98 0.98
002 0.97 0.94 CK3BA 036 0.98 0.98
003 0.95 0.92 — — —

OUTDOOR COIL ENTERING AIR TEMPERATURES °F –3 7 17 27 37 47 57 67
Pwr Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†
650AN036-A,C Outdoor Section With FX4ANF042 Indoor Section
65 1125 14.7 13.5 2.42 18.3 16.8 2.51 21.9 20.0 2.59 25.8 22.9 2.66 30.4 27.6 2.76 35.6 35.6 2.88 41.7 41.7 3.04 48.8 48.8 3.27 1250 14.9 13.7 2.45 18.5 17.0 2.53 22.9 20.9 2.61 26.1 23.2 2.67 30.7 27.9 2.76 35.9 35.9 2.87 42.1 42.1 3.03 49.3 49.3 3.25 1375 15.1 13.9 2.49 18.7 17.2 2.56 22.4 20.4 2.62 26.3 23.4 2.68 31.0 28.2 2.76 36.3 36.3 2.87 42.5 42.5 3.03 49.7 49.7 3.25
70 1125 14.1 13.0 2.51 17.9 16.4 2.61 21.6 19.7 2.70 25.4 22.6 2.79 29.9 27.2 2.89 35.0 35.0 3.02 41.5 41.5 3.19 48.0 48.0 3.42 1250 14.4 13.2 2.54 18.1 16.7 2.63 21.9 19.9 2.72 25.7 22.8 2.79 30.2 27.5 2.89 35.4 35.4 3.00 41.5 41.5 3.17 48.5 48.5 3.40 1375 14.6 13.4 2.58 18.4 16.9 2.66 22.1 20.1 2.74 26.0 23.1 2.81 30.5 27.8 2.89 35.7 35.7 3.00 41.8 41.8 3.16 48.9 48.9 3.39
Cooling Capacity Power Capacity Power FX4ANF 042 1.00 1.00 CJ5A/CK5A/CK5BA 042 0.98 1.02
FC4BN(F,B) 042 0.98 1.02 CJ5A/CK5A/CK5BN 042 0.98 1.02
FK4CNF 003 0.96 0.96 048 0.98 1.01
005 0.97 0.89 CJ5A/CK5A/CK5BW 048 0.98 1.01
FV4ANF 003 0.96 0.95 CK3BA 042 0.98 1.02
005 0.97 0.89 048 0.98 1.01
048 0.98 1.01 650AN042-A,C Outdoor Section With FV4ANF003 Indoor Section
65 1225 17.3 15.9 2.61 21.5 19.8 2.74 25.7 23.4 2.86 30.0 26.6 2.99 35.1 32.0 3.14 41.1 41.1 3.34 40.4 40.4 3.30 39.5 39.5 3.21 1400 17.6 16.2 2.61 22.5 20.7 2.74 25.9 23.6 2.84 30.2 26.9 2.95 35.5 32.3 3.09 41.5 41.5 3.28 40.8 40.8 3.22 40.0 40.0 3.14 1575 17.8 16.4 2.62 21.9 20.2 2.73 26.1 23.8 2.83 30.5 27.1 2.93 35.8 32.6 3.06 41.9 41.9 3.24 41.2 41.2 3.18 40.4 40.4 3.09
70 1225 16.8 15.5 2.74 21.1 19.4 2.88 25.4 23.2 3.03 29.6 26.3 3.16 34.7 31.6 3.32 40.5 40.5 3.53 39.8 39.8 3.48 38.9 38.9 3.38 1400 17.1 15.7 2.75 21.4 19.6 2.87 25.6 23.4 3.00 29.9 26.6 3.12 35.0 31.9 3.27 41.0 41.0 3.46 40.2 40.2 3.40 39.4 39.4 3.30 1575 17.3 15.9 2.76 21.6 19.8 2.87 25.8 23.6 2.99 30.1 26.8 3.10 35.3 32.2 3.24 41.3 41.3 3.42 40.6 40.6 3.35 39.8 39.8 3.25
Cooling Capacity Power Capacity Power FV4ANF 003 1.00 1.00 FX4ANF 042 1.02 1.01
FC4BN(F,B) 048 1.02 1.02 CJ5A/CK5A/CK5BA 048 1.02 1.03
FK4CNF 003 0.99 1.00 CJ5A/CK5A/CK5BN 048 1.02 1.03
005 0.99 0.93 CJ5A/CK5A/CK5BW 048 1.02 1.03
FV4ANF 005 0.99 0.93 CK3BA 048 1.02 1.03

OUTDOOR COIL ENTERING AIR TEMPERATURES °F –3 7 17 27 37 47 57 67
Pwr Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†
650AN048-A,C Outdoor Section With FV4ANF005 Indoor Section
65 1400 18.5 17.0 2.86 22.9 21.1 2.99 27.9 25.4 3.11 33.5 29.8 3.26 40.2 36.6 3.45 48.2 48.2 3.69 53.8 53.8 4.34 53.1 53.1 4.20 1600 18.7 17.2 2.87 23.2 21.3 2.98 28.1 25.6 3.10 33.8 30.1 3.23 40.7 37.0 3.41 48.7 48.7 3.64 54.4 54.4 4.28 53.7 53.7 4.14 1800 18.9 17.4 2.89 23.4 21.5 2.99 28.4 25.9 3.10 34.1 30.3 3.23 41.0 37.3 3.40 49.1 49.1 3.63 54.9 54.9 4.26 54.1 54.1 4.12
70 1400 18.1 16.7 3.03 22.7 20.9 3.16 27.6 25.2 3.29 33.2 29.4 3.44 39.8 36.2 3.64 47.5 47.5 3.89 54.3 54.3 4.57 52.3 52.3 4.40 1600 18.4 16.9 3.03 23.0 21.1 3.15 27.8 25.4 3.27 33.5 29.7 3.41 40.2 36.5 3.60 48.0 48.0 3.83 53.6 53.6 4.50 52.9 52.9 4.33 1800 18.6 17.1 3.05 23.2 21.3 3.16 28.1 25.6 3.27 33.8 30.0 3.41 40.5 36.9 3.58 48.4 48.4 3.81 54.1 54.1 4.47 53.3 53.3 4.31
Cooling Capacity Power Capacity Power FV4ANF 005 1.00 1.00 FX4ANB 060 1.01 1.02
FB4ANB 070 1.01 1.02 CE3AA 060 1.01 1.06
FC4BN(F,B) 060 1.01 1.09 CJ5A/CK5A/CK5BA 060 1.01 1.03
FC4BNB 070 1.01 1.02 CJ5A/CK5A/CK5BN 060 1.02 1.04
FK4CNB 006 1.01 0.96 CJ5A/CK5A/CK5BX 060 1.02 1.04
FK4CNF 005 1.01 1.01 CK3BA 060 1.01 1.03
FV4ANB 006 1.01 0.96 — — — 650AN060-B,C Outdoor Section With FV4ANB006 Indoor Section
65 1750 24.4 22.4 3.73 30.9 28.4 3.88 37.9 34.6 4.05 45.0 40.0 4.24 52.6 47.9 4.45 60.8 60.8 4.68 58.2 58.2 4.52 56.3 56.3 4.47 2000 24.9 22.9 3.76 31.5 28.9 3.90 38.5 35.1 4.05 45.7 40.6 4.22 53.2 48.4 4.41 61.6 61.6 4.61 59.0 59.0 4.44 57.1 57.1 4.37 2250 25.3 23.3 3.80 31.9 29.3 3.93 39.0 35.5 4.06 46.2 41.0 4.23 53.7 48.9 4.39 62.2 62.2 4.58 59.6 59.6 4.39 57.8 57.8 4.31
70 1750 23.4 21.5 3.92 30.0 27.6 4.09 37.0 33.7 4.27 44.2 39.2 4.46 52.0 47.3 4.70 60.0 60.0 4.94 57.4 57.4 4.76 55.4 55.4 4.71 2000 23.8 21.9 3.95 30.5 28.0 4.10 37.6 34.3 4.26 44.8 39.8 4.44 52.5 47.8 4.65 60.7 60.7 4.87 58.1 58.1 4.67 56.2 56.2 4.60 2250 24.3 22.3 4.00 31.0 28.5 4.13 38.1 34.7 4.28 45.4 40.3 4.45 53.1 48.3 4.63 61.4 61.4 4.83 58.8 58.8 4.62 56.9 56.9 4.53
Cooling Capacity Power Capacity Power FV4ANB 006 1.00 1.00 FX4ANB 060 1.00 1.03
FC4BNB 070 1.00 1.03 CJ5A/CK5A/CK5BX 060 0.98 1.02
FK4CNB 006 0.99 0.99 — – —
* The Btuh heating capacity values shown are net “integrated” values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity. † The kw values include the compressor, outdoor fan motor, and indoor blower motor. The kw from supplement heaters should be added to these values to
obtain total system kilowatts. EDB—Entering Dry Bulb

1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature for cooling mode is 125°F (51.7°C). 4. Minimum outdoor operating air temperature for heating mode is –30°F (–34.4°C). 5. Maximum outdoor operating air temperature for heating mode is 66°F (18.9°C). 6. For reliable operation, unit should be level in all horizontal planes. 7. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft. (See items 8 and 9 following). 8. For interconnecting refrigerant tube lengths greater than 50 ft and/or elevation differences between indoor and outdoor units greater than 20 ft, con- sult Residential Split-System Application Guideline and Service Manual for Air Conditioners and Heat Pumps using Puron Refrigerant. 9. If ANY refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36-in. may be buried without further considerations. Buried refrigerant tubing lengths greater than 36 in. are not recommended. 10. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 11. Mixmatches of indoor coil capacity more than 1 size larger than outdoor unit capacity (unless so specified) may result in inadequate indoor comfort. 12. Do not apply capillary tube indoor coils to these units. 13. Factory-supplied filter drier must be installed.




[ ] Packaged Service Training [ ] Classroom Service Training
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
© 1998 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indianapolis, IN 46231 —20— PRINTED IN U.S.A. Catalog No. 5265-002 1-99