

604D AND 607C LEGACYt AND PREFERREDt 13 AND 14 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURON (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2 -5 NOMINAL TONS (SIZES A24-A60)


A09042 Fig. 2 - Unit 607C

For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.

! CAUTION
Improper installation adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory--authorized kits or accessories when modifying this product Refer to the individual instructions packaged with the kits or accessories when installing.
Failure to follow this caution may result in personal injury.
Sheet metal parts mayhave sharpedges or burrs.Use careand wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing furnaces.
Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes, the current editions of the National Electrical Code (NEC) NFPA 70.
The operation of your heat pump system is controlled by the indoor thermostat. You simply adjust the thermostat and itmaintains thein- door temperature at the level you select. Most thermostats of heat pump systems have 3 controls: a temperature control selector, a FAN control, and a SYSTEM or MODE control. Refer to your ther- mostat owner’s manual for more information.
In Canada refer to the current editions of the Canadian electrical Code CSA C22.1.
To better protect your investment and to eliminate unnecessary ser- vice calls, familiarize yourself with the following facts:
Recognize safety information. This is the safety--alert symbol
. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety--alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to high- light suggestions which will result in enhanced installation, reli- ability, or operation. Note: Installer: This manual should be left with the equipment user.
To start the unit:
To shut off unit: Note: If the unit is being shut down because of a malfunction, call your dealer as soon as possible.
Failure to follow this warning could result in personal injury, death, and/or property damage. Installation and servicing of this equipment can be hazardous due to mechanical and electrical components. Only trained and qualified personnel should install, repair, or service this equipment.
With the SYSTEM or MODE control set to COOL, your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected. On extremely hot days, your unit will run for longer periods at a time and have shorter “off” periods than on moderate days.
With the SYSTEM or MODE control set to HEAT, your unit will run in heating mode until the room temperature is raised to the level you have selected. Of course, your unit will run for longer periods to maintain a comfortable environment on cooler days and nights than on moderate ones.
Failure to follow this warning could result in personal injury, death or property damage.
Do not use this unit if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system which has been under water.
Your unit is your primary heating source. Your system may also be equipped with a supplemental heating source such as electric heat. On cold days and nights, your system will automatically turn on the supplemental heat, as needed, in order to maintain the level of com- fort you have selected.
When your heat pump needs additional heat to keep you comfort- able your thermostat will turn on the supplemental heat (if equipped).
Failure to follow this warning could result in personal injury or death.
When your unit is providingheat toyour homeor officeand theout- door temperature drops below 45°F (7.2°C), moisture may begin to freezeonthe surfaceof thecoil. Ifallowed tobuild up,this icewould impede airflow across the coil and reduce the amount of heat ab-
Before performing recommended maintenance, be sure the main power switch to unit is turned off and a lock--out tag is installed.

sorbed from the outside air. So, to maintain energy--efficient opera- tion, your unit has an automatic defrost mode.
instance of filter grilles, the filters can simply be removed from the grille and replaced. The other typical application is an accessory filter rack installed in- side the unit itself. The following information is given to assist in changing filters used in these internal filter racks. Table 1 indicates the correct indoor filter size for your unit. Refer to Fig. 3 to access filters installed in the accessory filterrack. Ifusing an Accessory Filter Rack, refer to the Installation Instructions pro- vided with it for correct filter sizes and quantities.
The defrost mode starts at a preset time interval of 60 minutes, al- though, it may be reset to 30, 90 or 120 minutes. Defrost will start at the preset time only if the ice is sufficient to interfere with normal heating operation.
After the ice is melted from the coil, or after a maximum of 10 min- utes in defrost mode, the unit automatically switches back to normal heating operation.
Table 1—Air Filters Located Inside Unit
Do not be alarmed if steam or fog appears at the outdoor unit during defrost mode. Water vapor from the melting ice may condense into a mist in the cold outside air.

During certain weather conditions such as heavy snow and freezing rain it is not uncommon for ice to build up on the unit grille. This is normal for these weather conditions. Do not attempt to remove the ice from the unit grille. This condition will not affect the proper function of the unit and will clear within a few days.
To replace or inspect filters in accessory filter rack:
In the event of primary unit heat failure, the emergency heat mode allows your supplemental heating source to keep your home or of- fice warm until your unit can be serviced. Contact your dealer in the event of primary unit heat failure.
This section discusses maintenance that should be performed by your dealer and care you, as the owner, may wish to handle for your new unit.
All routine maintenance should be handled by skilled, experienced personnel. Your dealer can help you establish a standard procedure.

To assure proper functioning of the unit, flow of condenser air must not be obstructed from reaching the unit. Clearance from the top of the unit is 48 in. (1219 mm). Clearance of at least 36 in. (914 mm) is required on sides except the power entry side (42 in. clearance) (1067 mm) and the duct side (12 in. minimum clearance) (305mm).
Maintenance and Care for the Equipment Owner
Before proceeding with those things you might want to maintain yourself, please carefully consider the following:

Filter Access Panel For Accessory Filter Rack
Failure to follow this warning could result in personal injury, death or property damage.

Failure to follow this warning could result in personal injury, death or property damage.
Never operate your unit without filters in place. An accumulation of dust and lint on internal parts ofyour unit can cause loss of efficiency.
The air filter(s) should be checked every 3 or 4 weeks and changed or cleaned whenever it becomes dirty. Dirty filters produce exces- sive stress on the blower motor and can cause the motor to overheat and shut down.
Fans and Fan Motor Periodically check the condition of fan wheels and housings and fan--motorshaftbearings.Contactyourdealerforthe requiredannu- al maintenance. Indoor and Outdoor Coils Cleaning of the coils should only be done by qualified service per- sonnel. Contact your dealer for the required annual maintenance.
This unit must have an air filter in place before it can be operated. These filters should be located in at least one of two places. In many applications, the installer will provide return air filter grilles mounted on the wall or ceiling of the conditioned structure. In the

The drain pan and condensate drain line should be checked and cleaned at the same time the cooling coils are checked by your deal- er.
All compressors arefactory shippedwith anormal chargeof thecor- rect type and quantity of refrigeration grade oil. A compressor should rarely require additional oil.
Failure to follow this warning could result in personal injury, death or property damage.
Do not poke sticks, screwdrivers, or any other object into revolving fan blades.
The fan must be kept free of all obstructions to ensure proper cool- ing. Contact your dealer for any required service.
Your servicing dealer may offer an economical service contract that covers seasonal inspections. Ask for further details.
Electrical Controls and Wiring
Electrical controlsare difficultto checkwithout properinstrumenta- tion. If there are any discrepancies in the operating cycle, contact your local dealer and request service.
Complete service instructions can be found in the unit Installation, Start--up and Service Instructions.
Your unit has a limited warranty. Be sure to read the warranty care- fully to determine the coverage for your unit.
Therefrigerantcircuitisdifficulttocheckforleakswithout theprop- er equipment. If inadequate cooling is suspected, contact your local dealer for service.
Before you call for service...
...check for several easily solved problems.
If insufficient heating or cooling is suspected:
( ) Check for sufficient airflow. Check the air filter for dirt. Check forblockedreturnor supplyair grilles.Be surethey areopen andun- obstructed. If these checks do not reveal the cause, call your servic- ing dealer.
Failure to follow this warning could result in personal injury, death or property damage.
If your unit is not operating at all, check the following list for easy solutions:
System under pressure. Relieve pressure and recover all refrigerant before system repair or final unit disposal. Use all service ports and open all flow--control devices, including solenoid valves.
( ) Check to be sure that your thermostat temperature selector is set below the indoor temperature during the cooling season or above theindoortemperatureduring heatingseason. Besure theSYSTEM switch or MODE control is in the COOL or HEAT and not OFF.
After performing any maintenance or service on the unit, be sure all panels are fastened securely in place to prevent rain from entering unit cabinet and to prevent disruption of the correct unit airflow pat- tern.
( ) If your unit still fails to operate, call your servicing dealer for troubleshooting and repairs. Specify the model and serial numbers of your unit. (Record them in this manual in the space provided.) If the dealer knows exactly which unit you have, he may be able to of- fer suggestions over the phone, or save valuable time through knowledgeable preparation for the service call.
In addition to the type of routine maintenance you might be willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection (preferably each year, but at least every other year) should include the following:
In Case of Trouble If you perform the steps above and unit performance is still unsatis- factory, shut off the unit and call your dealer.
Heating & Cooling Systems
“Heating Equipment” or “Air Conditioning Contractors & Systems” heading for dealer listing by brand name.
Have available the Model No., Series Letter, & Serial No. of your equipment to ensure correct replacement part.
Copyright 2009 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indianapolis, IN 46231
Printed in the U.S.A.
Catalog No:OM604D---607C---01 Edition Date: 03/09
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.