SAFETY CONSIDERATIONS Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified personnel should install, repair, or service air-conditioning equipment. Untrained personnel can perform basic maintenance functions of cleaning coils and filters. All other operations should be performed by trained service personnel. When working on air-conditioning equipment, observe precautions in the literature, tags, and labels attached to the unit, and other safety precautions that may apply.
Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for unbrazing operations. Have fire extinguisher available for all brazing operations.
Recognize safety information. This is the safety-alert symbol
. When you see this symbol on the product or in instructions or manuals, be alert to the potential for personal injury.
Understand the signal words — DANGER, WARNING, CAU- TION, and NOTE. Danger identifies the most serious hazards, which will result in severe personal injury or death. Warning indicates a condition that could cause serious personal injury or death. Caution is used to identify unsafe practices, which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
Fig. 1—Unit 604B
b. Select temperature and set SYSTEM switch or MODE
control to desired mode.
a. Set system SWITCH or MODE control to OFF.
b. Turn off the electrical power supply to unit.
OPERATING YOUR HEAT PUMP The operation of your heat pump system is controlled by the indoor thermostat. You simply adjust the thermostat and it maintains the indoor temperature at the level you select. Most thermostats of heat pump systems have 3 controls: a temperature control selector, a FAN control, and a SYSTEM or MODE control. Refer to your thermostat owner’s manual for more information. To better protect your investment and to eliminate unnecessary service calls, familiarize yourself with the following facts:
a. Turn on the electrical power supply to unit.

To assure proper functioning of the unit, flow of condenser air must not be obstructed from reaching the unit. Clearance from the top of the unit is 48 in. Clearance of at least 36 in. is required on sides except the power entry side (42 in. clearance) and the duct side (12 in. minimum clearance). B. Maintenance and Care for the Equipment Owner Before proceeding with those things you might want to maintain yourself, please carefully consider the following:
I. COOLING MODE With the SYSTEM or MODE control set to COOL, your heat pump will run in cooling mode until the indoor temperature is lowered to the level you have selected. On extremely hot days, your heat pump will run for longer periods at a time and have shorter “off” periods than on moderate days.
TO YOUR UNIT BEFORE SERVIC- ING OR PERFORMING MAINTE- NANCE. ELECTRIC SHOCK COULD CAUSE SERIOUS INJURY OR DEATH. 2. When removing access panels or performing mainte- nance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care is taken to keep sharp edges to a minimum, be extremely careful when handling parts or reaching into the unit.
II. HEATING MODE With the SYSTEM or MODE control of your indoor thermostat set to HEAT, your heat pump will run in heating mode until room temperature is raised to the level you have selected. Of course, your heat pump will run for longer periods to maintain a comfortable environment on cooler days and nights than on moderate ones.
III. SUPPLEMENTAL HEAT Your heat pump is your primary heating source. Your system may also be equipped with a supplemental heating source such as electric heat. On cold days and nights, your system will automati- cally turn on the supplemental heat in order to maintain the level of comfort you have selected. When your heat pump needs additional heat to keep you comfort- able, your Bryant electronic thermostat will turn on the supple- mental heat (if equipped) and display the “AUX HT” message.
The air filter(s) should be checked at least every 3 or 4 weeks and changed or cleaned whenever it becomes dirty. Dirty filters produce excessive stress on the blower motor and can cause the motor to overheat and shut down. This unit must have air filters in place before it can be operated. These filters can be located in one of at least two places. In many applications the installer will provide return air filter grilles mounted on the wall or ceiling of the conditioned structure. In the instance of filter grilles, the filters can simply be removed from the grille and replaced. The other typical application is an accessory filter rack installed inside the unit itself. The following information is given to assist in changing filters used in these internal filter racks. Table 1 indicates the correct filter size for your unit. Refer to Fig. 2 to access filters installed in the accessory filter rack.
When your heat pump is providing heat to your home or office and the outdoor temperature drops below 45°F, moisture may begin to freeze on the surface of the coil. If allowed to build up, this ice would impede airflow across the coil and reduce the amount of heat absorbed from the outside air. So, to maintain energy-efficient operation, your heat pump has an automatic defrost mode. The defrost mode starts at a preset time interval of 30 minutes, although, it may be reset to 60, 90 or 120 minutes. Defrost will start at the preset time only if the ice is sufficient to interfere with normal heating operation. After the ice is melted from the coil, or after a maximum of 10 minutes in defrost mode, the unit automatically switches back to normal heating operation. Do not be alarmed if steam or fog appears at the outdoor unit during defrost mode. Water vapor from the melting ice may condense into a mist in the cold outside air. During certain weather conditions such as heavy snow and freezing rain it is not uncommon for ice to build up on the unit grille. This is normal for these weather conditions. Do not attempt to remove the ice from the unit grille. This condition will not affect the proper function of the unit and will clear within a few days.
UNIT SIZE FILTER SIZE 604B024-030 20x20x1 604B036 20x24x1 604B042-060 24x30x1
To replace or inspect filters in accessory filter rack (See Fig. 2):
1. Remove the filter access panel using a 5/16-in. nut driver. 2. Remove the filter(s) by pulling it out of the unit. If the filter(s) is dirty, clean or replace with a new one. When installing the new filter(s), note the direction of the airflow arrows on the filter frame. If you have difficulty locating your air filter(s) or have questions concerning proper filter maintenance, contact your dealer for instructions. When replacing filters, always use the same size and type of filter that was supplied, originally, by the installer.
This allows your supplemental heating source to keep your home or office warm until your heat pump can be serviced.
MAINTENANCE AND SERVICE This section discusses maintenance that should be performed by your dealer and care you, as the owner, may wish to handle for your new heat pump.
A. Routine Maintenance
All routine maintenance should be handled by skilled, experienced personnel. Your dealer can help you establish a standard proce- dure. For your safety, keep the unit area clear and free of combustible materials, gasoline, and other flammable liquids and vapors.
Periodically, check the condition of fan wheels and housings and fan-motor shaft bearings. Contact your dealer for the required annual maintenance.

UNIT PANELS After performing any maintenance or service on the unit, be sure all panels are fastened securely in place to prevent rain from entering unit cabinet and to prevent disruption of the correct unit airflow pattern.
C. Regular Dealer Maintenance In addition to the type of routine maintenance you might be willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection (preferably each year, but at least every other year) should include the following:
FILTER ACCESS PANEL*
*For accessory filter rack.
Fig. 2—Accessory Filter Rack Access Panel
Cleaning of the coils should only be done by qualified service personnel. Contact your dealer for the required annual mainte- nance.
The drain pan and condensate drain line should be checked and cleaned at the same time the cooling coils are checked by your dealer.
All compressors are factory-shipped with a normal charge of the correct type refrigeration grade oil. A compressor should rarely require additional oil.
D. Warranty Certificate
Unit 604B has a limited warranty. Be sure to read the warranty carefully to determine the coverage for your unit.
E. Before You Call for Service ...
...check for several easily-solved problems. If insufficient heating or cooling is suspected: ( ) Check for sufficient airflow. Check the air filter for dirt. Check for blocked return-air or supply-air grilles. Be sure they are open and unobstructed. If these checks do not reveal the cause, call your servicing dealer. If your unit is not operating at all, check the following list for easy solutions: ( ) Check to be sure that your thermostat temperature selector is set below the indoor temperature during the cooling season or above the indoor temperature during heating season. Be sure the SYS- TEM switch or MODE control is in the COOL or HEAT position and not in the OFF position. ( ) If your unit still fails to operate, call your servicing dealer for troubleshooting and repairs. Specify the model and serial numbers of your unit. (Record them in this manual in the space provided.) If the dealer knows exactly which unit you have, he may be able to offer suggestions over the phone, or save valuable time through knowledgeable preparation for the service call.
The fan must be kept free of all obstructions to ensure proper cooling. Contact your dealer for any required service.
Electrical controls are difficult to check without proper instrumen- tations. If there are any discrepancies in the operating cycle, contact your dealer and request service.
REFRIGERANT CIRCUIT The refrigerant circuit is difficult to check for leaks without the proper equipment. If inadequate cooling is suspected, contact your local dealer for service.

F. In Case of Trouble If you perform the steps above and unit performance is still unsatisfactory, shut off the unit and call your dealer. Dealer’s Name
© 2003 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 —4— Printed in U.S.A. om0262 Catalog No. 5360-401