EN
Bryant logo
Official user manual

Bryant 224A

8 pages·318 KB·Heat Pump·PDF·ENDEFRITNLJA
Bryant 224A
Table of Contents 56 sections SAFETY CONSIDERATIONS · OUTDOOR WALL INDOOR WALL · CAULK · LIQUID TUBE · … ShowHide
Page 1 of the Bryant 224A user manual — INSTALLATION RECOMMENDATIONS
Page 1 · click to enlarge
Page 1
Bryant 224A — SAFETY CONSIDERATIONS diagram (page 1)
Fig. 1

223A, 224A Legacyt Line Heat Pump with Puronr Refrigerant 1--1/2 To 5 Nominal Tons (Sizes 018 to 060) Installation Instructions

5. When passing refrigerant tubes through the wall, seal opening with RTV or other pliable silicon--based caulk. (See Fig. 1.) 6. Avoid direct tubing contact with water pipes, duct work, floor joists, wall studs, floors, and walls. 7. Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with tubing.(See Fig. 1.) 8. Ensure that tubing insulation is pliable and completely surrounds vapor tube. 9. When necessary, use hanger straps which are 1 in. wide and conform to shape of tubing insulation. (See Fig. 1.) 10. Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory--authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements.

Avoid contact between tubing and structure NOTE:

OUTDOOR WALL INDOOR WALL

CAULK

Recognize safety information. This is the safety--alert symbol !!. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety--alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

LIQUID TUBE

VAPOR TUBE INSULATION

THROUGH THE WALL

JOIST

HANGER STRAP (AROUND VAPOR

TUBE ONLY)

INSULATION

VAPOR TUBE

Bryant 224A — LIQUID TUBE diagram (page 1)
Fig. 2

1″ MIN.

LIQUID TUBE

Failure to follow this warning could result in personal injury or death.

SUSPENSION

Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label.

A94028 Fig. 1 -- Connecting Tubing Installation

When outdoor unit is connected to factory--approved indoor unit, outdoor unit contains system refrigerant charge for operation with ARI rated indoor unit when connected by 15 ft. (4.57 m) of field--supplied or factory accessory tubing. For proper unit operation, check refrigerant charge using charging information located on control box cover and/or in the Check Charge section of this instruction. IMPORTANT: Maximum liquid--line size is 3/8--in. OD for all residential applications including line line. IMPORTANT: Always install the factory--supplied liquid--line filter drier. Obtain replacement filter driers from your distributor or branch.

INSTALLATION RECOMMENDATIONS

1. Locate unit away from windows, patios, decks, etc. where unit operation sound may disturb customer. 2. Ensure that vapor and liquid tube diameters are appropriate for unit capacity. 3. Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends. 4. Leave some slack between structure and unit to absorb vibration.
Page 2 of the Bryant 224A user manual — UNIT DAMAGE HAZARD
Page 2 · click to enlarge
Page 2

INSTALLATION Check Equipment and Job Site Unpack Unit Move to final location. Remove carton taking care not to damage unit. Inspect Equipment

Operating Ambient

The minimum outdoor operating ambient in cooling mode without accessory is 55°F (12.78°C), and the maximum outdoor operating ambient in cooling mode is 125°F (51.67°C). The maximum outdoor operating ambient in heating mode is 66 °F (18.89°C). Check Defrost Thermostat

File claim with shipping company prior to installation if shipment is damaged or incomplete. Locate unit rating plate on unit corner panel. It contains information needed to properly install unit. Check rating plate to be sure unit matches job specifications. Install on a Solid, Level Mounting Pad

Check defrost thermostat to ensure it is properly located and securely attached. There is a liquid header with a brass distributor and feeder tube going into outdoor coil. At the end of the one of the feeder tubes, there is a 3/8 in. O.D. stub tube approximately 2 in. long. (See Fig. 3.) The defrost thermostat should be located on stub tube. Note that there is only one stub tube used with liquid header, and on most units it is the bottom circuit.

If conditions or local codes require the unit be attached to pad, tie down bolts should be used and fastened through knockouts provided in unit base pan. Refer to unit mounting pattern in Fig. 2 to determine base pan size and knockout hole location. For hurricane tie downs, contact distributor for details and PE Certification (Professional Engineer), if required. On rooftop applications, mount on level platform or frame. Place unit above a load--bearing wall and isolate unit and tubing set from structure. Arrange supporting members to adequately support unit and minimize transmission of vibration to building. Consult local codes governing rooftop applications. Roof mounted units exposed to winds above 5 mph may require wind baffles. Consult the Service Manual -- Residential Split System Air Conditioners and Heat Pumps for wind baffle construction. NOTE: Unit must be level to within ±2° (±3/8 in./ft) per compressor manufacturer specifications. Clearance Requirements

Bryant 224A — Operating Ambient diagram (page 2)
Fig. 3 · Operating Ambient

A97517 Fig. 3 -- Defrost Thermostat Location

Make Piping Connections

! WARNING

When installing, allow sufficient space for airflow clearance, wiring, refrigerant piping, and service. Allow 24 in. (609.6 mm) clearance to service end of unit and 48 in. (1219.2 mm) (above unit. For proper airflow, a 6--in. (152.4 mm) clearance on 1 side of unit and 12--in. (304.8 mm) on all remaining sides must be maintained. Maintain a distance of 24 in. (609.6 mm) between units. Position so water, snow, or ice from roof or eaves cannot fall directly on unit. On rooftop applications, locate unit at least 6 in. above roof surface.

PERSONAL INJURY AND ENVIRONMENTAL HAZARD

Failure to follow this warning could result in personal injury or death.

Relieve pressure and recover all refrigerant before system repair or final unit disposal.

Use all service ports and open all flow--control devices, including solenoid valves.

3/8---in. (9.53 mm) Dia. Tiedown Knockouts in Basepan(2) Places

Bryant 224A — PERSONAL INJURY AND ENVIRONMENTAL HAZARD diagram (page 2)
Fig. 4

UNIT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage or improper operation.

If ANY refrigerant tubing is buried, provide a 6--in (152.4 mm). vertical rise at service valve. Refrigerant tubing lengths up to 36--in (914.4 mm). may be buried without further special consideration. Do not bury lines longer than 36 in (914.4 mm).

Outdoor units may be connected to indoor section using accessory tubing package or field--supplied refrigerant grade tubing of correct size and condition. For tubing requirements beyond 80 ft, substantial capacity and performance losses can occur. Following the recommendations in the Application Guideline and Service Manual--Residential Split--System Air Conditioners and Heat Pumps will reduce these losses. Refer to Table 1 for accessory requirements. Refer to Table 2 for field tubing diameters. There are no buried--line applications greater than 36 in. (914.4 mm) If refrigerant tubes or indoor coil are exposed to atmosphere, they must be evacuated to 500 microns to eliminate contamination and moisture in the system.

UNIT BASE PAN DimensionTIEDOWN KNOCKOUT LOCATIONS in. (mm) ABC 26 X 269–1/8 (231.8)4–7/16 (112.7)21–1/4 (539.8) 31–1/2 X 31–1/29–1/8 (231.8)6–9/16 (166.7)24–11/16 (627.1) 35 X 359–1/8 (231.8)6–9/16 (166.7)28–7/16 (722.3)

A05177 Fig. 2 -- Tiedown Knockout Locations

Page 3 of the Bryant 224A user manual — Operating Ambient
Page 3 · click to enlarge
Page 3

Table 1 – Accessory Usage

RE AccessoryQUIRED FOR LOW---AMBIENT COOLING APPLICATIONS (Below 55°F / 12.8°C)REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 ft. / 24.38 m)REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km) AccumulatorStandardStandardStandard Ball Bearing Fan MotorYes{NoNo Compressor Start Assist Capacitor and RelayYesYesNo Crankcase HeaterYesYesNo Evaporator Freeze ThermostatYesNoNo Hard Shutoff TXVYesYesYes Isolation RelayYesNoNo Liquid Line Solenoid ValveNoSee Long---Line Application GuidelineNo Motor Master® Control or Low Ambient SwitchYesNoNo Support FeetRecommendedNoRecommended

* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline. { Additional requirement for Low---Ambient Controller (full modulation feature) MotorMasterr Control. Outdoor Unit Connected To Factory Approved Indoor Unit

Table 2 – Refrigerant Connections and Recommended Liquid

and Vapor Tube Diameters (In.)

UNIT SIZELIQUIDRATED VAPOR up to 80 ft. (24.38 m)* Connection DiameterTub Diamee Connection ter DiameterTube Diameter 018, 0243/83/85/85/8 030, 0363/83/83/43/4 042, 0483/83/87/87/8 0603/83/87/81--1/8

Outdoor unit contains correct system refrigerant charge for operation with approved ARI rated indoor unit when connected by 15 ft (4.57 m) of field--supplied or factory--accessory tubing, and factory supplied filter drier. Check refrigerant charge for maximum efficiency. Refrigerant Tubing and Sweat Connections

Connect vapor tube to fitting on outdoor unit vapor service valves (see Table 2). Connect liquid tubing to adapter tube on liquid service valve. Use refrigerant grade tubing.

2. Do not apply capillary tube or fixed orifice indoor coils to these units.
Bryant 224A — Operating Ambient diagram (page 3)
Fig. 5 · Operating Ambient

* For Tubing Set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or 20 ft. (6.10 m) vertical differential (250 ft./ 76.2 m)Total Equivalent Length), refer to the Longline Guideline--- Air Conditioners and Heat Pumps using Puronr Refrigerant. Install Liquid Line Filter Drier Indoor

Failure to follow this caution may result in equipment damage or improper operation.

Refer to Fig. 5 and install filter drier as follows:

1. Braze 5 in. (127 mm) liquid tube to the indoor coil. 2. Wrap filter drier with damp cloth. 3. Braze filter drier to 5 in. (127 mm) long liquid tube from step 1. 4. Connect and braze liquid refrigerant tube to the filter drier.

Service valves must be wrapped in a heat--sinking material such as a wet cloth while brazing.

Remove plastic retainer holding outdoor piston in liquid service valve, leaving the piston and piston retainer inside the valve. Connect sweat/flare adapter provided, to valve. (See Fig. 4.) Connect refrigerant tubing to fittings on outdoor unit vapor and liquid service valves. Service valves are closed from factory and ready for brazing. After wrapping service valve with a wet cloth, tubing set can be brazed to service valve using either silver bearing or non--silver bearing brazing material. Do not use soft solder (materials which melt below 800°F/427°C). Consult local code requirements. Refrigerant tubing and indoor coil are now ready for leak testing. This check should include all field and factory joints.

Bryant 224A — Operating Ambient diagram (page 3)
Fig. 6 · Operating Ambient

A05227 Fig. 5 -- Liquid Line Filter Drier Evacuate Refrigerant Tubing and Indoor Coil

Bryant 224A — Operating Ambient diagram (page 3)
Fig. 7 · Operating Ambient

Failure to follow this caution may result in equipment damage or improper operation.

Never use the system compressor as a vacuum pump.

Refrigerant tubes and indoor coil should be evacuated using the recommended deep vacuum method of 500 microns. The alternate triple evacuation method may be used (see triple evacuation procedure in service manual). Always break a vacuum with dry nitrogen.

A05226 Fig. 4 -- Liquid Service Valve

Page 4 of the Bryant 224A user manual — WIRING
Page 4 · click to enlarge
Page 4

Deep Vacuum Method The deep vacuum method requires a vacuum pump capable of pulling a vacuum of 500 microns and a vacuum gage capable of accurately measuring this vacuum depth. The deep vacuum method is the most positive way of assuring a system is free of air and liquid water. A tight dry system will hold a vacuum of 1000 microns after approximately 7 minutes. See Fig. 6.

Connect Ground and Power Wires Connect ground wire to ground connection in control box for safety. Connect power wiring to contactor as shown in Fig. 7.

Bryant 224A — MICRONS diagram (page 4)
Fig. 8

Failure to follow this warning could result in personal injury or death.

Bryant 224A — MICRONS diagram (page 4)
Fig. 9

The unit cabinet must have an uninterrupted or unbroken ground to minimize personal injury if an electrical fault should occur. The ground may consist of electrical wire or metal conduit when installed in accordance with existing electrical codes.

MICRONS

Connect ground wire to ground connection in control box for safety. Connect power wiring to contactor as shown in Fig. 7.

DISCONNECT PER N.E.C. AND/OR LOCAL CODES

CONTACTOR

MINUTES 0 1 2 3 4 5 6 7

A95424

FIELD POWER

WIRING

A95424 Fig. 6 -- Deep Vacuum Graph

BLUE 3 PHASE ONLY

FIELD GROUND

Final Tubing Check IMPORTANT: Check to be certain factory tubing on both indoor and outdoor unit has not shifted during shipment. Ensure tubes are not rubbing against each other or any sheet metal. Pay close attention to feeder tubes, makings sure wire ties on feeder tubes are secure and tight. Be sure field wiring complies with local and national fire, safety, and electrical codes, and voltage to system is within limits shown on unit rating plate. Contact local power company for correction of improper voltage. See unit rating plate for recommended circuit protection device. NOTE: Operation of unit on improper line voltage constitutes abuse and could affect unit reliability. See unit rating plate. Do not install unit in system where voltage may fluctuate above or below permissible limits.

WIRING

GROUND LUG

A94025 Fig. 7 -- Line Connections

Bryant 224A — WIRING diagram (page 4)
Fig. 10
Bryant 224A — WIRING diagram (page 4)
Fig. 11

A00010 Fig. 8 -- 3--Phase Monitor Control

Failure to follow this caution may result in equipment damage or improper operation.

(Applies to 3--Phase Units Only)

Table 3 – 3--Phase Monitor LED Indicators

Installation of filter drier in liquid line is required. Make Electrical Connections

LEDSTATUS OFFNo call for compressor operation FLASHINGReversed phase ONNormal
Bryant 224A — WIRING diagram (page 4)
Fig. 12

Failure to follow this warning could result in personal injury or death.

Do not supply power to unit with compressor terminal box cover removed.

NOTE: Use copper wire only between disconnect switch and unit. NOTE: Install branch circuit disconnect of adequate size per NEC to handle unit starting current. Locate disconnect within sight from and readily accessible from unit, per Section 440--14 of NEC. Route Ground and Power Wires Remove access panel to gain access to unit wiring. Extend wires from disconnect through power wiring hole provided and into unit control box.

Page 5 of the Bryant 224A user manual — Follow these steps to properly start up system:
Page 5 · click to enlarge
Page 5

loading and increase the transformer capacity or split the load with an accessory transformer as required. Final Wiring Check IMPORTANT: Check factory wiring and field wire connections to ensure terminations are secured properly. Check wire routing to ensure wires are not in contact with tubing, sheet metal, etc. Compressor Crankcase Heater

TYPICAL FAN COIL

HEAT PUMP

HP THERMOSTAT

24 VAC HOT R

R

R

24 VAC COM

W2

W2

HEAT STAGE 2

W2

COOL/HEAT STAGE 1

E

When equipped with a crankcase heater, furnish power to heater a minimum of 24 hr before starting unit. To furnish power to heater only, set thermostat to OFF and close electrical disconnect to outdoor unit. A crankcase heater is required if refrigerant tubing is longer than 80 ft. Refer to the Long Line Guideline--Residential Split--System Air Conditioners and Heat Pumps. Install Electrical Accessories

Y

Y

W3

INDOOR FAN

G

G

RVS COOLING

O

O

EMERGENCY HEAT

E

IF AVAILABLE *

LEGEND

Refer to the individual instructions packaged with kits or accessories when installing. Start--Up

24-V FACTORY WIRING

24-V FIELD WIRING

ODT

FIELD SPLICE CONNECTION

OUTDOOR THERMOSTAT

EHR

EMERGENCY HEAT RELAY

SUPPLEMENTAL HEAT RELAY SHR

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal injury.

A02325 / A97413 Fig. 9 -- Generic Wiring Diagrams (See Thermostat Installation Instructions for

Wear safety glasses, protective clothing, and gloves when handling refrigerant and observe the following: S Front seating service valves are equipped with Schrader valves.

Sequence of Operation NOTE: Defrost control board is equipped with 5 minute lockout timer that is initiated upon any interruption of power. Turn on power to indoor and outdoor units. Transformer is energized. Cooling On a call for cooling, thermostat makes circuits R--O, R--Y, and R--G. Circuit R--O energizes reversing valve, switching it to cooling position. Circuit R--Y sends low voltage through the safeties and energizes the T1 terminal on the circuit board. If the compressor has been off for 5 minutes, or power has not been cycled for 5 minutes, the OF2 relay and T2 terminal will energize. This will close the contactor, and start the outdoor fan motor and compressor. When the cycle is complete, R--Y is turned off, stopping the compressor and outdoor fan. The 5 minute time guard begins counting. Compressor will not come on again until this delay expires. In the event of a power interruption, the time guard will not allow another cycle for 5 minutes.

ENVIRONMENTAL HAZARD

Failure to follow this caution may result in environmental damage.

Federal regulations require that you do not vent refrigerant to the atmosphere. Recover during system repair or final unit disposal.

UNIT OPERATION AND SAFETY HAZARD

Failure to follow this caution may result in personal injury, equipment damage or improper operation. S Do not overcharge system with refrigerant. S Do not operate unit in a vacuum or at negative pressure. S Do not disable low pressure switch in scroll compressor

applications. S Compressor dome temperatures may be hot.

Heating On a call for heating, thermostat makes circuits R--Y and R--G. Circuit R--Y sends low voltage through the safeties and energizes the T1 terminal on the circuit board. T1 energizes the defrost logic circuit. If the compressor has been off for 5 minutes, or power has not been cycled for 5 minutes, the OF2 relay and T2 terminal will energize. This will close the contactor, start the outdoor fan motor and compressor. When the cycle is complete, R--Y is turned off , stopping the compressor and outdoor fan. The 5 minute time guard begins counting. Compressor will not come on again until this time delay expires. In the event of a power interruption, the time guard will not allow another cycle for 5 minutes.

Follow these steps to properly start up system:

1. After system is evacuated, fully open liquid and vapor service valves. 2. Unit is shipped with valve stem(s) front seated (closed) and caps installed. Replace stem caps after system is opened to refrigerant flow (back seated). Replace caps finger--tight and tighten with wrench an additional 1/12 turn. 3. Close electrical disconnects to energize system. 4. Set room thermostat at desired temperature. Be sure set point is below indoor ambient temperature. 5. Set room thermostat to HEAT or COOL and fan control to ON or AUTO mode, as desired. Operate unit for 15 minutes. Check system refrigerant charge.

Show 4 more labels / short text on this page
* · * · * · specific unit combinations)
Page 6 of the Bryant 224A user manual — CARE AND MAINTENANCE
Page 6 · click to enlarge
Page 6

Quiet Shift Quiet shift is a field selectable defrost mode (factory set to OFF), which will eliminate occasional noise that could be heard at the start of defrost cycle and restarting of heating cycle. It is selected by placing DIP switch 3 on defrost board (see Fig. 10) in the ON position. When Quiet Shift switch is placed in ON position, and a defrost is initiated, the following sequence of operation will occur. Reversing valve will energize, compressor will turn off for 30 seconds, and then turn back on to complete defrost. At the start of heating after conclusion of defrost, reversing valve will de--energize, compressor will turn off for another 30 seconds, and the fan will turn off for 40 seconds, before starting in the heating mode. Defrost The defrost control is a time/temperature control which has field selectable settings of 30, 60, 90, or 120 minutes, factory set to 90 minutes. These settings represent the amount of time that must pass after closure of the defrost thermostat before the defrost sequence begins. The defrost thermostat senses coil temperature throughout the heating cycle. When the coil temperature reaches the defrost thermostat setting of approximately 32_F, it will close, which energizes the DFT terminal and begins the defrost timing sequence. When the DFT has been energized for the selected time, the defrost cycle begins. Defrost cycle is terminated when defrost thermostat opens, or automatically after 10 minutes. Defrost Speedup To initiate a forced defrost, speedup pins (J1) must be shorted with a flat head screwdriver for 5 seconds and RELEASED. If the defrost thermostat is open, a short defrost cycle will be observed (actual length depends on Quiet Shift switch position). When Quiet Shift is off, only a short 30 second defrost cycle is observed. With Quiet Shift ON, the speedup sequence is one minute; 30 second compressor off period followed by 30 seconds of defrost with compressor operation. When returning to heating mode, the compressor will turn off for an additional 30 seconds and the fan for 40 seconds. If the defrost thermostat is closed, a complete defrost cycle is initiated. If the Quiet Shift switch is turned on, the compressor will be turned off for two 30 second intervals as explained previously.

Check Charge

Factory charge amount and desired subcooling are shown on unit rating plate. Charging method is shown on information plate inside unit. To properly check or adjust charge, conditions must be favorable for subcooling charging. Favorable conditions exist when the outdoor temperature is between 70_F and 100_F (21.11_C and 37.78_C), and the indoor temperature is between 70_F and 80_F (21.11_C and 26.67_C). Follow the procedure below: Unit is factory charged for 15ft (4.57 m) of lineset. Adjust charge by adding or removing 0.6 oz/ft of 3/8 liquid line above or below 15ft (4.57 m) respectively. For standard refrigerant line lengths (80 ft/24.38 m or less), allow system to operate in cooling mode at least 15 minutes. If conditions are favorable, check system charge by subcooling method. If any adjustment is necessary, adjust charge slowly and allow system to operate for 15 minutes to stabilize before declaring a properly charged system. If the indoor temperature is above 80_F (26.67_C), and the outdoor temperature is in the favorable range, adjust system charge by weight based on line length and allow the indoor temperature to drop to 80_F (26.67_C) before attempting to check system charge by subcooling method as described above. If the indoor temperature is below 70_F (21.11_C), or the outdoor temperature is not in the favorable range, adjust charge for line set length above or below 15ft (4.57 m) only. Charge level should then be appropriate for the system to achieve rated capacity. The charge level could then be checked at another time when the both indoor and outdoor temperatures are in a more favorable range. NOTE: If line length is beyond 80 ft (24.38 m) or greater than 20 ft (6.10 m) vertical separation, See Long Line Guideline for special charging requirements. Heating Check Chart Procedure

To check system operation during heating cycle, refer to the Heating Check Chart on outdoor unit. This chart indicates whether a correct relationship exists between system operating pressure and air temperature entering indoor and outdoor units. If pressure and temperature do not match on chart, system refrigerant charge may not be correct. Do not use chart to adjust refrigerant charge. Final Checks

Bryant 224A — Check Charge diagram (page 6)
Fig. 13 · Check Charge
1. Ensure that all wiring is routed away from tubing and sheet metal edges to prevent rub--through or wire pinching. 2. Ensure that all wiring and tubing is secure in unit before adding panels and covers. Securely fasten all panels and covers. 3. Tighten service valve stem caps to 1/12--turn past finger tight. 4. Leave Owner’s Manual with owner. Explain system operation and periodic maintenance requirements outlined in manual. 5. Fill out Dealer Installation Checklist and place in customer file.

Defrost interval DIP switches Quiet Shift

A05378 Fig. 10 -- Defrost Control Table 4 – Defrost Control Speedup--Timing Sequence

CARE AND MAINTENANCE

For continuing high performance and to minimize possible equipment failure, periodic maintenance must be performed on this equipment. Frequency of maintenance may vary depending upon geographic areas, such as coastal applications. See Users Manual for information.

PARAMETERMINIMUM (MINUTES)MAXIMUM (MINUTES)SPEEDUP (NOMINAL) 30---minute cycle27337 sec 50---minute cycle455512 sec 90---minute cycle819921 sec 10---minute cycle9112 sec 5 minutes4.55.51 sec
Bryant 224A — CARE AND MAINTENANCE diagram (page 6)
Fig. 14

Speedup Pins

Page 7 of the Bryant 224A user manual — PURON R (R--410A) QUICK REFERENCE GUIDE
Page 7 · click to enlarge
Page 7

PURON R (R--410A) QUICK REFERENCE GUIDE

S Puron refrigerant operates at 50--70 percent higher pressures than R--22. Be sure that servicing equipment and replacement

components are designed to operate with Puron S Puron refrigerant cylinders are rose colored. S Recovery cylinder service pressure rating must be 400 psig, DOT 4BA400 or DOT BW400. S Puron systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose when

charging into suction line with compressor operating S Manifold sets should be 700 psig high side and 180 psig low side with 550 psig low--side retard. S Use hoses with 700 psig service pressure rating. S Leak detectors should be designed to detect HFC refrigerant. S Puron, as with other HFCs, is only compatible with POE oils. S Vacuum pumps will not remove moisture from oil. S Do not use liquid--line filter driers with rated working pressures less than 600 psig. S Do not leave Puron suction line filter driers in line longer than 72 hours. S Do not install a suction--line filter drier in liquid line. S POE oils absorb moisture rapidly. Do not expose oil to atmosphere. S POE oils may cause damage to certain plastics and roofing materials. S Wrap all filter driers and service valves with wet cloth when brazing. S A factory approved liquid--line filter drier is required on every unit. S Do NOT use an R--22 TXV. S If indoor unit is equipped with an R--22 TXV or piston metering device, it must be changed to a hard shutoff Puron TXV. S Never open system to atmosphere while it is under a vacuum. S When system must be opened for service, recover refrigerant, evacuate then break vacuum with dry nitrogen and replace filter

driers. Evacuate to 500 microns prior to recharging. S Do not vent Puron into the atmosphere. S Do not use capillary tube coils. S Observe all warnings, cautions, and bold text. S All indoor coils must be installed with a hard shutoff Puron TXV metering device.

Page 8 of the Bryant 224A user manual — PURON R (R--410A) QUICK REFERENCE GUIDE
Page 8 · click to enlarge
Page 8
ReplacesII223A---18---3 Catalog No. II223A---18---4

E2007 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 12/07

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Ask about the Bryant 224A

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bryant 224A

Be the first to ask — other owners or our team will answer.

Original document

Bryant 224A manual PDF

8 pages·318 KB·Heat Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…