Page 1 of the AdobeAir US960 user manual — Durable Construction
Page 1 · click to enlarge
Page 1
AdobeAir US960 — INDUSTRIAL DIRECT AND INDIRECT/DIRECT EVAPORATIVE COOLING diagram (page 1)
Fig. 1

INDUSTRIAL DIRECT AND INDIRECT/DIRECT EVAPORATIVE COOLING

Engineer designed to satisfy your design requirements.

Modular Components

Cost Effectiveness

  • Air Handling Modules in side, down or up discharge and single or dual inlet design.
  • Competitive fi rst cost combined with substantial energy savings over refrigerated air units results in quick payback. Plus, the simplicity of design allows low maintenance requirements.
  • Evaporative Media Modules with standard 8” or Hi-Performance 12” media.
  • Indirect Cooling Modules for added cooling with no moisture added (optional).

Other Features

  • Precision balanced blower wheel.

Durable Construction

  • Solid shaft for rugged durability.
  • Galvanized steel with our exclusive POLYBOND® polyester epoxy powder based coating ensures years of dependable service. Effi ciency
  • AdobeAir motors and pumps are U.L. Recognized.
  • City of Los Angeles (C.O.L.A.) approved.
  • AMCA Licensed ratings
  • U.L. Classifi ed
  • U.L. Listed
  • Choice of media modules allows cooling effi ciencies tailored to your design requirements.
AdobeAir US960 — Durable Construction diagram (page 1)
Fig. 2 · Durable Construction
AdobeAir US960 — Durable Construction diagram (page 1)
Fig. 3 · Durable Construction

Dual Inlet Models MD628, MS628, and MU628 U.L. Classified Shown with 12” media modules DM120

Single Inlet Models MD524 and MS524 U.L. Classified Shown with 12” media modules DM080

Models UD980 and US980 U.L. Listed Shown with 12” media modules UM120

Models UD960 and US960 U.L. Listed Shown with 12” media modules UM080

AdobeAir, Inc. certifies that the evaporative air cooling products shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

AdobeAir US960 — Durable Construction diagram (page 1)
Fig. 4 · Durable Construction
Page 2 of the AdobeAir US960 user manual — SINGLE-STAGE INDUSTRIAL EVAPORATIVE COOLING
Page 2 · click to enlarge
Page 2

SINGLE-STAGE INDUSTRIAL EVAPORATIVE COOLING

MasterCool Evaporative Media MasterCool evaporative media is constructed of special cellulose material, impregnated with insoluble anti-rot salts and rigidifying saturants. The cross-fl uted design continually directs water to the air-entering side, inducing a highly turbulent mixing of air and water for optimum heat and moisture transfer.

Direct Evaporative Cooling Process Direct evaporative cooling exchanges sensible heat for latent heat, and follows upward along a constant wet-bulb temperature line on the Psychrometric Chart. The result is a dry-bulb temperature of the leaving air (B) approaching the wet-bulb temperature of the entering air (A).

AdobeAir US960 — SINGLE-STAGE INDUSTRIAL EVAPORATIVE COOLING diagram (page 2)
Fig. 5

Standard and Hi-Performance Models The fl exibility of modular components allows selection of CFM and saturation effi ciencies producing the sensible heat capacities needed to meet design requirements. For many applications, our standard 8” media continues to be an economical choice, with an 80% saturation effi ciency at 450 FPM. For more demanding design conditions, our 12” media offers 90% effi ciency at around 450 FPM.

Direct Evaporative Cooling Put simply, whenever water is evaporated, heat is absorbed. This basic principle underlies the design of the MasterCool direct evaporative cooler.

Comfort Levels Not only does evaporative cooling lower the temperature in the space to be cooled, it also lowers the temperature you feel. Rapid air movement produced by the MasterCool increases skin evaporation which causes you to feel 3-5° effectively cooler than the temperature read from a thermometer. Evaporative cooling can provide effective temperatures acceptable in most commercial/ industrial applications throughout the world.

High Quality Construction Hot-dipped galvanized steel, welded for maximum strength is combined with our exclusive POLYBOND® fi nish that protects the whole system – cabinet pans, distributor covers, louvers, and all other parts contacting water. The electrostatically applied polyester epoxy powder-based coating is cured at high temperature and is so durable that these models are backed by the best warranty in the industry.

Typical Applications The Industrial MasterCool is used for area cooling or spot cooling. In many areas it can replace or supplement mechanical refrigeration needs in agricultural, institutional, commercial, and industrial applications. Applications such as kitchens, laundries, gymnasiums, heat treating areas, and dry cleaning plants requiring large quantities of fresh air moving through the building are ideal candidates for evaporative cooling.

Energy Efficient... Environmentally Friendly With no compressors or condensors, MasterCool evaporative coolers offer signifi cant energy savings over mechanical refrigeration units; and, with no CFC’s, do not contribute to depletion of the ozone layer. Their air washing effect improves indoor air quality with fresh, fi ltered air constantly brought into the cooled space...forcing stale air out.

AdobeAir US960 — SINGLE-STAGE INDUSTRIAL EVAPORATIVE COOLING diagram (page 2)
Fig. 6
Page 3 of the AdobeAir US960 user manual — 2-STAGE INDUSTRIAL EVAPORATIVE COOLING
Page 3 · click to enlarge
Page 3

2-STAGE INDUSTRIAL EVAPORATIVE COOLING

The Indirect Cooling Module Outside air is drawn into the ICM. A fan draws air through the inside of vertical fi ns (which have water running inside them). The air picks up heat and is expelled from the ICM while the fi ns are cooled by evaporation. Other outside air is drawn across the outside surfaces of the cooled fi ns, and is cooled without coming in contact with water. This cooled air, with no humidity added, then enters the direct evaporative section of the Industrial MasterCool for fi nal cooling.

Indirect/Direct Evaporative Cooling Process In the indirect cooling stage, entering air is cooled along a horizontal humidity ratio line on the Psychrometric Chart (A to B) without adding moisture. In the next cooling stage, this air is further cooled along a new wet-bulb line (B to C), resulting in a lower dry-bulb temperature of leaving air than can be achieved with single stage direct evaporative cooling alone.

AdobeAir US960 — 2-STAGE INDUSTRIAL EVAPORATIVE COOLING diagram (page 3)
Fig. 7

Typical Confi gurations Many confi gurations of 2-Stage Industrial MasterCool are possible. Typical fi eld-assembled components include 2 or 3 Indirect Cooling Modules with Models MD/MS524 and 4 or 6 ICM’s with models MD/MS/

MU628 Contact your local MasterCool representative for assistance in sizing.

AdobeAir US960 — 2-STAGE INDUSTRIAL EVAPORATIVE COOLING diagram (page 3)
Fig. 8

Models shown with three ICM’s at each inlet location.

2-Stage Indirect/Direct Evaporative Cooling 2-Stage cooling allows you to use energy-saving evaporative cooling technology for design conditions where direct evaporative cooling alone is not adequate. A 2-stage cooler results in greater cooling power, less affected by higher ambient temperature and humidity.

KoolKalk... Computer Aided Sizing The sizing method described in this brochure can be used for general sizing of direct evaporative Industrial MasterCool units.

For more accurate sizing, and for sizing indirect/direct units, we recommend the use of KoolKalk... an IBM compatible computer program designed specifi cally for AdobeAir Evaporative Coolers. For more information please visit the AdobeAir, Inc. website at www.AdobeAir.com

In the indirect cooling stage, outside entering air is cooled sensibly reducing its total enthalpy. This “precooled” air is then evaporatively cooled in the direct cooling stage, approaching its new, lower wet-bulb temperature.

The end result is discharge temperatures near or even slightly below the wet-bulb temperature. More importantly, these lower discharge temperatures translate into customer comfort at a fraction of the cost of refrigerated air conditioning.

Applications With its substantial increase in cooling capacity, the indirect/direct 2-stage Industrial MasterCool can replace mechanical refrigeration in many applications.

Page 4 of the AdobeAir US960 user manual — Pump Specifi cations
Page 4 · click to enlarge
Page 4

DIMENSIONS AND SPECIFICATIONS

Single Inlet Model Dimensions MD524 or UD960 (Down Discharge) and MS524 or US960 (Side Discharge)

Top View Side View Front View

AdobeAir US960 — Top View Side View Front View diagram (page 4)
Fig. 9 · Top View Side View Front View
AdobeAir US960 — Top View Side View Front View diagram (page 4)
Fig. 10 · Top View Side View Front View

MD/MS524 or UD/US960

Duct Location Side Down A B C EDrain1 Location F GMedia Cabinet JBlower Cabinet KWater2 Service Location L MElectric3 Service Location S TBlower Wheel Dia. Width ShaftBlower Pulley Pitch Dia.Skid Location N P Q RMedia Dimension X V DM080 or UM080 51½ 491/ 8 6626¾ 17 3 11¼13 133/ 817491/ 87¼ 123/ 818 35½24 24 13/ 16132 15/ 8 4 2½445/ 8 4814.8 DM120 or UM120 51½ 491/ 8 7026¾ 17 3 11¼13 173/ 821491/ 87¼ 163/ 822 35½24 24 13/ 16132 15/ 8 4 2½445/ 8 4814.8
AdobeAir US960 — MD/MS524 or UD/US960 diagram (page 4)
Fig. 11 · MD/MS524 or UD/US960
1. Drain is 3/4” male hose thread. 2. Water service can be left or right for 1/4” tubing. 3. 7/8” knockout for running electrical service.

Electrical Specifi cations HP Speed Phase Voltage Amperage NEMA Frame Shaft Diameter Motor Kit # ¾ 1 1 115/230 12.5/6.2 56 5/8 EJ006 ¾ 2 1 230 5.9 56 5/8 EJ020 ¾ 1 3 208-230/460 3.0/1.5 56 5/8 EJ883 115/230 15.1/7.5 56 5/8 EJ007 1 2 1 230 7.3 56 5/8 EJ021 1 1 3 208-230/460 3.6/1.7 143T 7/8 EJ665 1½ 1 1 115/230 14.5/6.3 143T 7/8 EJ212 1½ 1 3 208-230/460 4.6/2.2 143T 7/8 EJ666 2 1 1 115/230 19.0/8.5 143T 7/8 EJ213 2 1 3 208-230/460 7.1/3.3 143T 7/8 EJ667 3 1 3 208-230/460 8.7-8.4/4.2 182T 11/8 EJ668 5 1 3 208-230/460 14.2-13.0/6.5 184T 11/8 EJ659 7½ 1 3 208-230/460 20.9-19.2/9.6 213T 13/8 EJ675

  • Amperage from National Electric Code.
  • See nameplate on actual motor for amperage in fi guring overload protector.
  • Single phase motors rated 230 volts can be operated at nameplate amps at 208 volts.
  • All 3-phase motors listed are suitable for use on evaporative coolers at 200 volts.

Pump Specifi cations

Bleed Rates GPH per Media Module

Pump Volts Amps Watts GPH Model# At 4’ Head CP280 115 1.2 80 300 CP480 230 .6 80 300

Blower Model Blower Motor HP ¾ 1 1½ 2 3 5 7½ 524 or 960 7 8 9 10 10 – – 628 or 980 – 11 13 14 16 18 20

Page 5 of the AdobeAir US960 user manual — (T1 - LAT)
Page 5 · click to enlarge
Page 5

Dual Inlet Model Dimensions MD628 or UD980 (Down Discharge), MS628 or US980 (Side Discharge) and MU628 (Up Discharge)

(UP) Top View Side View - Blower Section Front View

AdobeAir US960 — (UP) Top View Side View - Blower Section Front View diagram (page 5)
Fig. 12 · (UP) Top View Side View - Blower Section Front View

MD/MS/MU628 or UD/US980

Duct Location Side Down A B C EDrain1 Location F GMedia B Cabinet Jlower Cabinet KWater2 Service Location L MElectric3 Service Location S TBlower Wheel Dia. Width ShaftBlower Pulley Pitch Dia.Skid Location N P Y Q RMedia Dimension X V DM080 or UM080 51½ 831/ 8 491/ 831¾ 17¾ 15¼ 8¾13 133/ 817491/ 871⁄4 123/ 818 35½28 28 13/ 161819 15/ 8 2 4 2½445/ 8 4814.8 DM120 or UM120 51½ 911/ 8 491/ 831¾ 17¾ 15¼ 8¾13 173/ 821491/ 871⁄4 163/ 822 35½28 28 13/ 161823 15/ 8 4 4 2½445/ 8 4814.8
AdobeAir US960 — MD/MS/MU628 or UD/US980 diagram (page 5)
Fig. 13 · MD/MS/MU628 or UD/US980
1. Drain is 3/4” male hose thread. 2. Water service can be left or right for 1/4” tubing. 3. 7/8” knockout for running electrical service.

Sizing Instructions Follow these steps to properly size the Industrial MasterCool. The performance or Sensible Heat Capacity of any cooler is a function of both the CFM and saturation effi ciency (which determines the delivered air discharge temperature). Sizing by only considering CFM may result in an improperly sized application.

Refer to the Electrical Specifi cations chart on facing page.

4. Determine the RPM that will deliver the required airfl ow (CFM) at the static pressure of the system.

Refer to the Certifi ed Air Delivery CFM chart for the chosen cooler and selected motor HP.

1. Determine design conditions:
5. Determine the sheave, and the number of turns open, that is closest to the desired RPM.

Refer to the Sheave Selection charts on the next page. Find the selected motor HP, shaft size, and desired RPM (See Steps 2-4 above). You might need to look at more than one sheave before fi nding the correct RPM.

2. Determine design sensible heat load (Btuh)
6. Specify the sheave and sheave setting (turns open) for the installer. Ordering When ordering your cooler, you should know this information.
3. Determine leaving air temperature (LAT):

LAT = DB1 - [(DB1 - WB ) * EFF]

where EFF ‘ 0.80 for 8” media or 0.90 for 12” media

  • System design static pressure.
4. Determine CFM required:
  • Desired air volume at system design.

CFM = 0.925 * Sensible Heat Load

  • Electrical power supply available.

(T1 - LAT)

  • Stability of structure to support operating weight of unit.
5. Determine the cooler(s) required:

Complete systems consist of the following components, and are sold separately for application versatility.

Refer to the specifi cation / air fl ow charts on next page.

6. Use KoolKalk to account for various losses:
  • Cabinet – 1 blower section

This will result in more accurate sizing. Motor Sheave Selection 1. Determine the external static pressure of the air delivery system.

  • Wet media section (1 for 524’s - 2 for 628’s)
  • Motor
  • Motor sheave
2. Determine the motor (H.P., Voltage and Phase) required to deliver the design airfl ow.
  • Pulley-belt kit
  • Pump (one required for each media section)
3. Determine the shaft size for the motor selected.

Outdoor Dry-Bulb DB1 · Outdoor Wet-Bulb WB1 · Indoor Dry-Bulb T1

Page 6 of the AdobeAir US960 user manual — DIMENSIONS
Page 6 · click to enlarge
Page 6

DIMENSIONS

Certifi ed Air Delivery CFM at Various External Static Pressures Inches Water Gauge. AMCA Licensed Ratings.

Belt information Quantity Down Side Up.0 .0 CFM RPM.1 .1 CFM RPM.2 .2 CFM RPM 524 with DM080 or 960 with UM080 — 8” Media 560 ¾ 1 AX78 AX80 6390 298 6070 310 5710 320 570 1 1 AX78 AX80 7030 329 6760 339 6420 349 575 1½ 1 AX78 AX80 8050 376 7810 385 7530 394 580 2 1 AX78 AX80 8860 414 8640 422 8400 430 590 3 1 AX78 A82* 9050 422 9050 440 9050 459 524 with DM120 or 960 with UM120 — 12” Media 600 ¾ 1 AX78 AX80 6250 298 5900 309 5550 321 610 1 1 AX78 AX80 6880 328 6560 338 6250 349 615 1½ 1 AX78 AX80 7880 376 7600 384 7320 393 620 2 1 AX78 AX80 8670 414 8420 421 8160 429 630 3 1 AX78 A82* 9050 422 9050 439 9050 458 628 with two DM080 or 980 with two UM080 — 8” Media 818 1 1 A95* A95* A95 9720 214 9320 224 8650 235 823 1½ 1 A95* A95* A95 11130 245 10720 254 10230 263 828 2 1 A95* A95* A95 12250 270 11890 278 11460 286 838 3 2 A97 A97 A95 14020 309 13720 316 13350 323 858 5 2 A97 A97 A95 16620 367 16390 371 16080 378 898 7½ 2 A100* A100* A95 18100 406 18100 418 628 with two DM120 or 980 with two UM120 — 12” Media 908 1 1 A95* A95* A95 9680 216 9080 226 8530 237 913 1½ 1 A95* A95* A95 11080 248 10540 256 10080 265 918 2 1 A95* A95* A95 12190 273 11700 280 11260 288 928 3 2 A97 A97 A95 13950 312 13510 318 13130 325 948 5 2 A97 A97 A95 16540 370 16050 375 15820 380 988 7½ 2 A100* A100* A95 18100 406 18100 409 18100 428 Shaded Areas: Do not exceed listed RPM, water entrainment may result. *Not supplied: MS524 coolers with a 3 HP motor require the purchase of one A82 belt (AX78 belt included with unit). MD628 and MS628 coolers with 1, 11⁄ or 2 HP motor 2 NOT RECOMMENDED requires one A95 belt (two A97 belts included with unit). MD628 and MS628 coolers with 71⁄ HP motor require two A100 belts (two A97 belts included with unit). 2 MD/MS 524 or UD/US 960 Sheave Selection 1 AX78 AX806390 2986070 3105710 320 1 AX78 AX807030 3296760 3396420 349 1 AX78 AX808050 3767810 3857530 394 1 AX78 AX808860 4148640 4228400 430 1 AX78 A82*9050 4229050 4409050 459 1 AX78 AX806250 2985900 3095550 321 1 AX78 AX806880 3286560 3386250 349 1 AX78 AX807880 3767600 3847320 393 1 AX78 AX808670 4148420 4218160 429 1 AX78 A82*9050 4229050 4399050 458 1 A95* A95* A959720 2149320 2248650 235 1 A95* A95* A9511130 24510720 25410230 263 1 A95* A95* A9512250 27011890 27811460 286 2 A97 A97 A9514020 30913720 31613350 323 2 A97 A97 A9516620 36716390 37116080 378 2 A100* A100* A9518100 40618100 418 1 A95* A95* A959680 2169080 2268530 237 1 A95* A95* A9511080 24810540 25610080 265 1 A95* A95* A9512190 27311700 28011260 288 2 A97 A97 A9513950 31213510 31813130 325 2 A97 A97 A9516540 37016050 37515820 380 2 A100* A100* A9518100 40618100 40918100 428
Page 7 of the AdobeAir US960 user manual — DIMENSIONS
Page 7 · click to enlarge
Page 7
.3 .3 CFM RPM.4 .4 CFM RPM.5 .5 CFM RPM.6 .6 CFM RPM.7 .7 CFM RPM.8 .8 CFM RPM.9 .9 CFM RPM1.0 1.0 CFM RPM 5320 3334850 3484200 3733670 3913200 4082770 4262400 4432060 460 6080 3595720 3715280 3864660 4094160 4263720 4423310 4582940 473 7250 4026930 4126630 4226240 4345840 4495260 4714830 4854440 499 7880 4467590 4557310 4646970 4756630 4876140 505 9050 4759050 4919050 5088820 5168570 5248330 5328030 5427730 552 5170 3344720 3494070 3713590 3903140 4072740 4232340 4411980 458 5910 3605540 3735130 3864510 4084060 4253650 4413270 4552900 471 7040 4036740 4136430 4246070 4355620 4505110 4694710 4844350 498 7920 4387650 4477380 4567100 4666760 4766440 4875930 5055510 520 9050 4759050 4928820 5098570 5188340 5268080 5347790 5447520 553 8030 2467380 2606670 2765240 3084540 3263840 3453290 3632740 379 9700 2739160 2838600 2947990 3077030 3295890 3545290 3714690 387 10510 30310010 3139500 3238960 3358360 3486990 379 12540 33712130 34511690 35311250 36210800 37110330 382 15770 38415450 39015090 39614730 40214390 40914020 41613660 42313280 430 18100 43118030 44017760 44517440 45017130 45516820 46116520 46716210 473 7930 2487220 2616490 2795130 3104390 3293810 3453220 3612630 376 9570 2749030 2858420 2967810 3106930 3305760 3585130 3744600 388 10830 29710350 3069860 3159310 3258730 3378110 3536900 3796150 398 12760 33212370 34011960 34811530 35611070 36410580 37310070 3849630 396 15510 38615190 39314890 39914530 40614190 41213820 41913460 42613060 433 18010 43717730 44317450 44817190 45416900 45916590 46516300 47115970 477
  • Power ratings (BHP) does not include drive losses.
  • Performance ratings include the effects of evaporative media in the airstream.
  • Belt tension should be 20 pounds for “A” section belts.
  • Performance shown is for installation type B: Free Inlet, Ducted Outlet.

MD/MS/MU 628 or UD/US 980 Sheave Selection Motor HP Browning Bore Blower RPM / Sheave Turns Open MasterCool Part # 5 4 ½ 4 3 ½ 3 2 ½ 2 1 ½ 1 ½ 0 Package # Single Phase Motor Blower RPM @ 1725 Motor RPM / Sheave Turns Open 1 1VL40 5/8 230 240 249 259 268 278 288 297 307 316 326 EL110 1½, 2 1VL40 7/8 230 240 249 259 268 278 288 297 307 316 326 EL112 1 1VL44 5/8 268 278 288 297 307 316 326 335 345 355 364 ESH2411 1½, 2 1VL44 7/8 268 278 288 297 307 316 326 335 345 355 364 EL685 1 1VP50 5/8 326 335 345 355 364 374 383 393 403 412 422 693 1½, 2 1VP50 7/8 326 335 345 355 364 374 383 393 403 412 422 686 Three Phase Motor Blower RPM @ 1750 Motor RPM / Sheave Turns Open 1, 1½, 2 1VL34 7/8 185 194 204 214 224 233 243 253 263 272 282 EL116 1, 1½, 2 1VL40 7/8 233 243 253 263 272 282 292 301 311 321 331 EL112 1, 1½, 2 1VL44 7/8 272 282 292 301 311 321 331 340 350 360 369 EL685 1, 1½, 2 1VP50 7/8 331 340 350 360 369 379 389 399 408 418 428 686 3 2VP42 11/8 253 263 272 282 292 301 311 321 331 340 350 687 3, 5 2VP50 11/8 331 340 350 360 369 379 389 399 408 418 428 688 5 2VP60 11/8 408 418 428 438 447 457 467 476 486 496 506 689 7½ 2VP60 13/8 408 418 428 438 447 457 467 476 486 496 506 692

Page 8 of the AdobeAir US960 user manual — Blower Section – Motor – Motor Sheave – Pulley and Belt Kit
Page 8 · click to enlarge
Page 8

Project Submittal Sheet Models MD/MS 524, MD/MS/MU 628 — U.L. Classifi ed or UD/US 960, UD/US 980 — U.L. Listed

*Total design sensible heat load of project.

Blower Section – Motor – Motor Sheave – Pulley and Belt Kit

Blower Section Motor Specifi cations Kits Ref. No. Qty. Model No. Motor HP Volts Phase Amps Motor Sheave Belt

*NOTE: Each unit (ready to operate) consists of one blower section, one blower motor, one pulley-belt kit, one motor sheave. Wet Section – Pump

Wet Section Pump Ref. No. Qty. Model No. Quantity Volts Amps GPM

*NOTE: Each wet section (ready to operate) consists of one wet module and one pump.

Your local MasterCool Representative of AdobeAir, Inc., is ready to assist you in unit selection and application.

MasterCool evaporative coolers and components are designed and tested in accordance with one or more of the following standards or agencies: Air Delivery: Data published derived from tests conducted in accordance with A.M.C.A. (Air Move- ment and Control Assoc.) Standard 210. Sealant: Water Immersion: per ASTM D870. Flexibility: per ASTM D756. Corrosion Resistance: per ASTM B117. Cycle Freeze/Thaw: per ASTM C117. POLYBOND®: Corrosion Resistance: per ASTM B117. Pencil Hardness: per ASTM D3363. Adhesion: per ASTM D3359. Impact Resistance: per ASTM D2794. Flexibility: per ASTM D522. Specular Gloss: per ASTM D523. Surface Burning Characteristics of Building Materials (best rating) per U.L. 723 and ASTM E-84. Pumps: Recognized under the U.L. component recognition program for the application – construc- tion, thermal overload, running overload, and locked rotor protection. Blower Motors: U.L. Recognized general purpose drip-proof. Polymeric Materials: Tested in accordance with U.L. 94 and 746C. Covered by City of Los Angeles Research Reports (C.O.L.A.) RR930224 (for all single phase applications), or RR930190 (for 3 phase applications) Electrical, and RR8141 Mechanical.

The world leader in evaporative cooling technology, AdobeAir, Inc. is continually involved in the process of product improvement. AdobeAir, Inc. therefore reserves the right to change specifi cations and/or design without prior notice. To obtain the most current product information and/or specifi cations, visit the AdobeAir, Inc. web site at www.AdobeAir.com

Manufactured in Mexico byAdobeAir, Inc. 1450 East Grant St. Phoenix, AZ 85034 www.AdobeAir.com
Show 7 more labels / short text on this page
Project SHL* · Location · Architect · Engineer · Contractor · Submitted By Date · L900799A March 2007
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the AdobeAir US960

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the AdobeAir US960

Be the first to ask — other owners or our team will answer.

Original document

AdobeAir US960 manual PDF

8 pages·308 KB·Humidifier·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…