(Ver.1.0)


JR_G6T_AOP_PUB is using 60G millimeter wave radar technology to
realize human respiratory heart rate perception and sleep assessment.
The module is based on the FMCW radar system, aiming at the output of
the respiratory heart rate frequency of personnel in specific
occasions, combined with the long-time sleep posture body motion
acquisition, and timely reporting the record of personnel's sleep
state and history.
Radar detection is realized based on FMCW FM continuous wave signal To achieve the synchronous perception of human respiration and heart rate
Realize a historical record of human sleep quality
Human sleep quality monitoring to detect the maximum distance:≤2.5m Human respiratory heart rate detects the maximum distance: ≤2.5m
Not affected by temperature, humidity, noise, airflow, dust, light and other environments
A Universal UART / RS485 communication interface that provides a general protocol;
Someone to unmanned detection (report) time: according to the algorithm, the typical value is 30 seconds


Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yuehai street,Nanshan district,Shenzhen city,Guandong province,China
Characteristic: · (a) front · (b) back

2.1Detection angle and distance

Antenna gain (GANT) / 5 / dBi
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yuehai street,Nanshan district,Shenzhen city,Guandong province,China

3.1Radar operating range
The beam coverage range of the radar module is shown in Figure 3. The radar covers a three-dimensional sector area of horizontal 60 and pitch 60.

Figure3Diagram of the radar beam coverage range
Affected by the beam characteristics of radar, the action distance of radar in the normal direction of the antenna surface is relatively far, but the action distance deviated from the antenna normal direction will become shorter. When the radar is tilted, the action scope of the radar will decrease due to the radar beam range and effective radiation space, so attention should be paid to when using.
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yuehai street,Nanshan district,Shenzhen city,Guandong province,China

duration of sleep quality
3.2.1Respiratory detection function
cavity and radar antenna surface)
3.2.2Heart detection function
cavity and radar antenna surface)
3.2.3Existence of detection
3.2.4Move detection
a.Movement trigger
b. Motion direction and position perception
4.1Installation
This radar module recommends tilt installation and a distance
of 1.5 m parallel to the scanning surface。
For the demand of sleep breathing and heartbeat detection, the
radar should be installed tilted (as shown in Figure 5). The radar
should be installed 1m directly above the bed and tilted 45 between
the bed. The distance between the radar and the chest cavity is
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China
antenna surface) The · radar antenna surface)

within 1.5m to ensure that the radar can normally detect breathing,
heartbeat and sleep-related parameters. The radar normal direction
is aligned with the main detection position to ensure that the main
beam of the radar antenna covers the human sleep detection area
land within certain boundaries.
The radar normal direction is aligned with the main detection
position to ensure that the main beam of the radar antenna covers
the human sleep detection area land within certain boundaries.
Limited by the beam range of the radar antenna, the effective
action distance of the radar normal direction will be reduced.
Millimeter wave frequency band electromagnetic wave has certain
penetration properties for non-metallic substances, which can
penetrate common glass and wood Plate, screens and thin partition
walls can detect moving objects behind the shelter; but for thicker
load-bearing walls, Metal doors, etc., do not penetrate.

Figure5i nst al l at i on ahead of t he bed
4.3 Operating mode of the radar
After the radar module passes the statistical analysis and
processing, the personnel status of the current detection area is
comprehensively evaluated, and the user can directly use the result.
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China

In this mode, the radar module periodically gives the existence
and movement states of personnel in the current radar detection
area. The main states include:
In this mode, for the accuracy of the environmental state
judgment, the state output logic of the radar module is as follows:
A. Only when the radar equipment detects the status change, it has
the corresponding status output of the radar; otherwise, the radar
B. The radar switch from unmanned to manned (motion, approach, away)
is a fast switching state, and the switching time is 1s;
C. If the radar switches from manned to unmanned, it needs to be
confirmed many times and the switching time is 1 minute;
D. Radar collects the breathing / heart rate frequency and breathing
/ heart rate signal state during the dynamic and static human body
in real time. The breathing heart rate frequency refresh frequency
is 3s, and the signal state changes and output;
In this mode, the module periodically gives the sleep status and
breathing rate of the personnel in the current radar detection area, and the
safety for the accuracy of sleep-related state judgment Installation
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China
remains silent; · main states include

mode and installation height limit;
The radar should be installed at 1m height directly above the head
of the bed, and tilted downward to 45 pairs in the middle of the bed,
to ensure that the distance between the radar and the human body
is within 1.5m, and to ensure that the radar detection range can
normally cover the sleep area.
This module is mainly used in scenarios such as health
management or home enabling. The following explains the
application mode of typical scenarios.
5.1.Bedroom installation and application
For specific applications, real-time relevant information
about bedridden personnel, such as human / unmanned, sleep
state, sleep depth, exercise information, etc., and then give
relevant information to achieve specific applications. In
this mode, the radar needs to be top-mounted. Based on this
mode of application, the application can be implemented
including.
a. Elderly care
b. Health care
c. Smart home
d. Family health
5.2.Healthy life application
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China

Based on the detection characteristics of the sleep state
and breathing rate of the sleepers, the radar can be better
used in a healthy life, including:
a. Intelligent health single product linkage application
b.Household electrical appliances
6.1Start time
Because the module needs to completely reset the internal
circuit of the module, and the environmental noise is fully
evaluated, to ensure the normal operation of the module.
Therefore, when the module is initially powered up, the startup
stabilization time needs 30s to ensure the effectiveness of the
subsequent output parameters.
6.2Respiratory and heartbeat detection scene limitations
Radar is a non-contact device, and the respiratory and
heartbeat detection of the target needs to lock the position of
the target first Then, the respiratory and heartbeat intensity
and value of the target were collected and calculated.
Therefore, the detection target is required to maintain a
resting state for detection within a reasonable detection range,
so as to avoid the continuous motion affecting the locking of
the radar to the target, thus affecting the detection of
breathing and heartbeat.
6.3Effective detection distance
The detection distance of the radar module is closely related to
the target RCS and environmental factors, and the effective
detection distance may change with the change of the environment and
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China

the target. This module does not have the ranging function
temporarily, so it is normal for the effective detection range to
fluctuate in a certain range.
6.4Radar biological detection performance
Because human biometric features are ultra-low frequency and
weak reflection characteristic signals, radar processing needs a
relatively long time of accumulation processing. In the
accumulation process, many factors may affect radar parameters, so
the accidental detection failure is a normal phenomenon.
6.5Power
The radar module has higher power quality requirements than
conventional low-frequency circuits. When powering the module, electricity
is required The source has no threshold burr or ripple phenomenon, and
effectively shields the power supply noise caused by the accessory
equipment. Radar module needs good grounding, and the ground noise caused
by other circuits may also cause the radar module performance decline or
even abnormal operation; the most common is that the detection distance is
approaching or the false alarm rate increases. To ensure the normal
operation of the VCO circuit inside the module, the power supply
requirement for this module is + 5V~+5.5V Electric, voltage ripple of
100mV. External power supplies must provide sufficient current output
capacity and transient responsiveness
My company thinks that we should try to describe the
documentation accurately during publication. Considering the
technical complexity of the product and the difference of the
working environment, it is still difficult to exclude some
inaccurate or incomplete descriptions, so this document is only for
user reference. Our company reserves the right to make changes to
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China

the product without notifying the users, and we will make no
promises and guarantees in any legal sense. Encourage customers to
comment on recent updates to the product and support tools.
The components and devices mentioned in this document are
references to the information published by the copyright holder
company, and the right to modify and publish it belongs to the
copyright holder company. Please confirm the update and errata
information through appropriate channels during the application. We
do not have any rights and obligations to these documents.
Shenzhen Jinghua phase control Co.,LTD
E-mail:JHXK@xkgtech.com.
Any Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China
Guandong province,China

the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for
help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set
forth for an uncontrolled environment .This equipment should be
installed and operated with minimum distance 20cm between the
radiator& your body.
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China

Integration instructions for host product manufacturers
according to KDB 996369 D03 OEM
10.1 List of applicable FCC rules
CFR 47 FCC PART 15 SUBPART C has been investigated. It is
applicable to the modular.
10.2 Specific operational use conditions
This module is stand-alone modular. If the end product will
involve the Multiple simultaneously transmitting condition or
different operational conditions for a stand-alone modular
transmitter in a host, host manufacturer have to consult with
module manufacturer for the installation method in end system.
10.3 Limited module procedures
10.4 Trace antenna designs
10.5 RF exposure considerations
To maintain compliance with FCC’s RF Exposure guidelines, This
equipment should be installed and operated with minimum distance of
20cm from your body.
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China
Manual v01 · Not applicable · Not applicable

10.6 Antennas
approved by Federal Communications Commission to operate with the
antenna types listed below, with the maximum permissible gain
indicated. Antenna types not included in this list that have a gain
greater than the maximum gain indicated for any type listed are
strictly prohibited for use with this device.
Antenna Type Frequency Range (MHz) Impedance
Microstrip Patch 60-64GHz 50 5.0
10.7 Label and compliance information
The final end product must be labeled in a visible area with the following" Contains FCC ID: 2A784JRG6TAOPPUB”2.9 Information on test modes and additional testing requirements
Host manufacturer is strongly recommended to confirm compliance with FCC requirements for the transmitter when the module is installed in the host.
10.8 Additional testing, Part 15 Subpart B disclaimer
Host manufacturer is responsible for compliance of the host system with module installed with all other applicable requirements for the system such as Part 15 B
Tel:0755-86567969Mail: jhxk@xkgtech.com Address:912 5A Building,ECO- Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China
Maximum antenna · gain(dBi)
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.