© 2020 This document or any part of it must not be translated, reproduced, or transmitted in any form or by any means, elec-tronic or mechanical, including photocopying, recording, or by any information or retrieval system. Violations will be prose-cuted. The use of general descriptive names, registered names, trademarks, etc. in this document does not imply, even in the absence of a specific statement, that such names are exempt from the relevant protective laws and regulations and therefore free for general use. Software programs will fully remain the property of ZEISS. No program, documentation, or subsequent up-grade thereof may be disclosed to any third party, unless prior written consent of ZEISS has been procured to do so, nor may be copied or otherwise duplicated, even for the customer's internal needs, apart from a single back-up copy for safety purposes.
ZEISS reserves the right to make modifications to this document without notice.
Original Manual


1 Welcome | 1.1 Working with ZEN starter ZEISS
ZEN core is the image acquisition and analysis software from ZEISS designed to support mainly in- dustry & manufacturing markets. Its design and intuitive user interface help you examine samples quickly, easily, and reliably, especially in quality assurance environments. The software offers two main operating modes. In Free mode you can configure and use the software freely to your per- sonal needs. It is designed for expert microscopy users who exactly know what they want to do. The workflow-based approach of the Job mode is used for repeatable experiments.
You can use the software without any license. The software is then run as the free version called ZEN starter with limited functionality. Nevertheless, you can still perform many typical actions, for example:
§ Load and view existing microscope images
§ Acquire images (Manual EDF, Panorama)
§ Perform interactive measurements (reduced set of tools available)
ZEN core is designed to support two fundamental ways of using your microscope:
§ Working with jobs (creating, running, editing and managing jobs) in Job Mode
§ Performing free examinations in Free Mode
Job Mode In the software, the term job refers to a collection of examination tasks. Jobs can be created to ensure that the same examination tasks are carried out each time the job is run, in the same man- ner, and with the same settings. Jobs are used mainly in routine quality control examinations where it is essential that identical examinations are performed for each sample.
Free Mode Free examinations can be used to inspect a sample quickly, easily, and flexibly without defining examination tasks. A typical use is to examine a faulty sample where the cause of the fault is un- known or for one-off examinations that will not be repeated. In such cases only the examination results, reports and images need to be saved rather than the examination tasks.
§ Create reports

2 Starting the Software | 2.1 User Interface - Home Screen ZEISS
Prerequisite ü The software and all required licenses have been installed.
1. Double click on the program icon on your desktop. à The software starts, and the login screen is displayed. 2. Click on the button of the application you want to work with. à The available applications depend on your licenses and system. à During the program start the hardware settings will be initialized. 3. On the login screen, click on your name in the list of users, and enter your password. Click Login. If you forgot your password or don`t know your user name, contact the System Administra- tor or Supervisor.
The Home Screen is displayed. You can start working with the software.
The Home Screen is displayed after you log in. The available operating modes depend on your user role.

1 Title Bar including System Messages icon, Workspace Zoom and Help icon.
2 Operating Modes selection, see Operating Modes [} 7].

3 Operating Modes ZEISS
ZEN core contains different operating modes that correspond to the different ways of working with the microscope. The modes that are available to you depend on your user role.

Free Mode Inspect a sample quickly, easily, and flexibly without defining examination tasks.

Job Mode Run an examination on a sample according to the step-by-step tasks defined in the job template.
Also, define fixed examination steps to be performed each time a sample is examined.

Manage Templates Edit and manage templates in the archive:
§ Image analysis settings
§ Standards technical cleanliness

Browse Results View and manage job results in the archive.

Maintenance Configure global settings, manage users, cali- brate measurements etc.

4 User Roles ZEISS
User management is an optional component. It is disabled by default. If user management is dis- abled, the user has all user rights at the same time. When user management is enabled, three types of user role are defined initially in the software:
The available modes and tasks you can perform in the software depend on your user role. User roles can be added and modified under Maintenance > User Management.
Administrators Administrators install and configure the software. This includes:
§ Managing system settings
§ Specifying the connected hardware in the Microscope Tool Box ap-
§ Configuring and managing the archives.
Supervisors Supervisors perform the following main tasks:
§ Creating job templates for the operators to run
§ Performing free examinations (Free Mode)
They are also able to perform the following tasks:
§ Managing jobs in the archive (running, editing, deleting)
§ Defining and evaluating job reports
§ Releasing Job Templates
Operators Operators can only perform a limited number of tasks:
§ Searching for a job
§ Running a job
§ Browsing the job results
2 User Interface - Home Screen [} 6]

5 Creating a Job Template | 5.1 Introduction ZEISS
This chapter only applies mainly to supervisors.
One typical workflow when creating a job template can be summarized in the following figure. Each step represents one task in the job template and is represented with an icon in the Task List.
1 Select Job Mode and click on Create a new template and edit it.
Use the microscope camera or load an image from the file system.
Enhance the image and configure which parameters can be modified, for example adjust the brightness and specify that contrast can only be altered +/- 10%.
Define the measurements to be performed and configure the accepted measurement tol- erances.
If desired, repeat steps 2 – 4.
Select a form template and specify the metadata to be recorded (e.g. sample ID, current time) and how it is entered (manually, automatically).
Select a report template and configure how measurement results and metadata should appear in it.

5 Creating a Job Template | 5.3 Creating a New Job Template ZEISS
Specify a name for the job template and which users are allowed to run it.
The software is supplied with example job templates which you can configure to your require- ments.
However, you can also create a new job template from scratch.
Prerequisite ü You are logged in as a supervisor or you have the sufficient privileges to create a job template
ü The Home Screen is visible
are displayed in the Workbench Panel. 4. Continue with the steps described in the typical workflow.
2 Specifying Tools for a Task [} 10]
2 Saving and Completing the Job Template [} 13]
2 Workflow [} 9]
For each task to be performed when the job is run, you can specify which tools are available to complete the task. For example, for a processing task, you can specify that only the White Bal- ance tool and Gauss tool are available.
This is done by adding and removing tools from the corresponding workbench so that only those required when running the job are included in the workbench.
If a tool is required when running a job, it must be included in the workbench. However, if you do not want the operator to be able to change the values of the tool parameters you can lock or hide individual parameters. To hide the entire task from the operator, right-click it and apply the Run Silent option. The task is then executed but not visible to the operator when the job is run.
To add a tool to a workbench:
See also · Adding tools

5 Creating a Job Template | 5.5 Locking and Hiding Parameters in Tools ZEISS
If you wish to add large numbers of tools to a workbench, it may be advisable to add another workbench of the same type and to distribute the tools across the two workbenches.
To remove a tool from a workbench:
If you remove a processing tool, the new processing result is not displayed until you click the cor- responding
icon in the Task List.
When creating a job template you can specify the operator's privileges for each parameter individ- ually. The privilege is indicated by the following icons:
Parameter can be seen and changed by the operator If the parameter can be changed by the operator, you can choose to limit the range of permitted values.
Parameter can be seen but not changed by the operator
Parameter is hidden from the operator (and thus cannot be changed)
To change the property of a parameter:
If all the parameters in a workbench are hidden or locked, the corresponding task is performed automatically in the background when the job is run.
If you want an entire task to be performed automatically in the background without user interac- tion, you can use the Run Silent option. This overrides the settings of individual parameters within the task.
2 Specifying Tools for a Task [} 10]
ZEN core contains various image processing tools you can apply to your images. To apply an im- age processing tool, you must select the Image Processing workbench and add the desired tool (if not already available).
To add an image processing tool:
Prerequisite ü You are logged in as a supervisor.
ü The Image Processing workbench is selected.

5 Creating a Job Template | 5.7 Analyzing the image ZEISS
The tool is added to the Image Processing workbench. You can now adjust it as required for the job, add more tools, or remove tools you do not need.
If you are working in Create a new template and edit it within Job Mode and a branch in the Task List contains multiple processing workbenches, they are all applied, from left to right. The output of a processing workbench provides the input for subsequent processing workbenches.
The same holds for the tools within one processing workbench: the processing tools are applied from top to bottom and the output of a processing tool provides the input for the subsequent processing tool.
2 Selecting Workbenches [} 21]
2 Specifying Tools for a Task [} 10]
Once you have acquired an image you can analyze its properties by performing various types of measurements. The measurement results can then be added to a report.
In Create Job Template mode you can specify which measurement tools are available when the job is run as well as tolerances (upper and lower limits for the measurement value).
ther tools, click Add Tool. 2. Select a tool and click in the image to measure the sample. 3. To specify measurement tolerances click the
icon. Expected value: Typically the theoretical value contained in the CAD data or sample speci- fication. Upper limit/Lower limit: Limits between which the measurement must lie, e.g. to fulfill quality control criteria. 4. Enter instructions about how to perform the task, for example which part of the sample should be measured in the input field of the workbench.
Forms provide a simple way to add information to a job when it is run by an operator. If the avail- able form templates in the Archive are not suitable for your purposes, you can create a new form template or modify an existing one.
The Form workbench is selected.
See also

5 Creating a Job Template | 5.9 Configuring a Job Report ZEISS
Reports enable you to collate all the information from your examination, e.g. images, measure- ment data and hardware setup, in a single document as a protocol of your examination.
Reports contain placeholders to enable you to collate the information easily. The placeholders also ensure that each time the job i run, the same information is added to the report.
button in the Add Templates tool. à Opens the Select Report Templates dialog. 3. Activate the checkbox of the desired report template, e.g. Report Form, and click the Se- lect button. 4. Select the report template in the Add Template tool to display the available placeholders. 5. Click on the arrow
in a placeholder, e.g. Image and select the corresponding measure- ment information that you wish to add. You can add multiple items to a single placeholder.
You can save a job template at any time during its creation. The Save Job Template dialog en- ables you to specify the following:
§ Job template properties (name and description)
§ Category to which the job template is assigned
§ Permissions (users that can run the job)
You can also modify the above in the Archive later.
For each job you can specify which users are allowed to run it. Typically, a group of users is speci- fied, but you can also specify individual users. By default, a job can be performed by any user.
Prerequisite ü You are in Create a new template and edit it within Job Mode.

6 Running a Job | 6.1 Introduction ZEISS
This chapter applies to supervisors and operators.
The following diagram shows an example of the workflow when running a job. Any steps where no interaction is required are performed automatically in the background.

1 Select the appropriate job for the sample.
2 Acquire an image of the region defined by the supervisor.
3 Process the image as defined by the supervisor.
4 Perform the analyses defined by the supervisor.
You are automatically guided through the analyses and presented with the appropriate tool.
Repeat steps 2 - 4 for other areas of the sample as defined by the supervisor.
5 Check the information in the job report.
6 Save the job results.
Prerequisite ü You are logged in as an operator.
ü You are on the Home Screen.

6 Running a Job | 6.4 Acquiring an Image ZEISS
à The first step in the job is displayed (typically acquire an image). 4. To continue with the next step, click on Next. 5. When you have completed all the steps, click on Save and close.
If the job requires a different hardware configuration to your current setup, the system prompts you which components need to be changed. For more information about how to change compo- nents, see your microscope instruction manual.
Acquiring an image is typically the first step when running a job. The image is acquired using the camera on your microscope.
more information, see your microscope instruction manual. 3. If your microscope has a motorized object revolver you can select the correct zoom level us- ing the software. à Otherwise, select the correct objective by hand. For more information, see your micro-
scope instruction manual. 4. If desired, adjust the acquisition parameters.
. 5. Click Snap. à If you are not satisfied with the image, click Live and repeat the above steps. 6. When you are satisfied with the image, click Next.
à For more information about individual parameters, click
Image processing enables you to adjust the appearance of the image after it has been acquired, for example to compensate changes in brightness if the illumination changes between jobs.
Typical processing actions include:
§ Brightness and contrast
§ Reduce noise and enhance contours
§ Adjust the size, rotation, and quality
The tools that you can use, and thus the properties that you can alter, depend on what the super- visor has enabled in the job template.
. 4. Click Next.
à For more information about individual parameters, click

6 Running a Job | 6.6 Performing an Interactive Measurement ZEISS
Interactive measurements enable you to measure e.g. distances, angles, area, and intensities of pixels. All the measurements to be performed in the current image are displayed in the Center Screen Area at the locations specified by the supervisor.
image. 4. Click Next.
If the supervisor specified an expected value and upper/lower limits for a measurement value (e.g. area or diameter), a corresponding color symbol in the Task Panel indicates whether your mea- surement result lies inside the expected limits (green) or outside the limits (red).
Reports enable you to collate all the information from your examination in a single document. Typical information includes:
§ Metadata (e.g. examination time, hardware setup)
Each report template contains placeholders for the above information to enable you to collate the information easily. The placeholders are usually filled automatically with the correct information. Depending on the settings applied when the job was created, you might be allowed to change the content of a placeholder.
in a placeholder and select the corresponding measurement infor- mation that you wish to add, for example image, measurement result, etc. à You can add multiple items to a single placeholder. The report preview updates accord-
ingly. 5. If you require a paper copy click Print Report.
When you have completed the last examination task, you can save the job.
§ Images · § Measurement data

6 Running a Job | 6.8 Saving and Completing a Job ZEISS
à Repeat the same job with a new sample. à Return to the Home Screen.

7 Performing a Free Examination | 7.1 User Interface - Free Mode ZEISS
The following figure shows the typical user interface when working in Free Mode.

Displays the added workbenches and tools.
Shows the current image, measurements and measurement results.
Lists the results of all the measurements in the image. You can show / hide the table by clicking on the Show/Hide results table button.
Contains a list of all documents (images, measurement results, reports and imported doc- uments) within the examination.
Click a document to display it and select it in the open task. Each time you apply a tool a new document is generated.
Some document formats might not be supported within ZEN core, e.g. .txt or MS Excel files. A link is provided to open them externally.
Here, you can adjust how the image is displayed (i.e. Gamma value). For a detailed de- scription, see Display tab.
Here, you can configure the display of additional hardware and acquisition data which are related to the acquired image. The data to be displayed can be configured under Maintenance | General Options | Documents | Image Data Zone Optional Data.
Data Zone Tab

7 Performing a Free Examination | 7.2 Workflow ZEISS
2 Workflow [} 19]
In Free Mode there is no typical workflow. In this mode, workbenches can be used in any se- quence.

1 Select Free Mode from the Home Screen.
Acquire an image using the camera or load an image from the file system.
Enhance the appearance of the image using various processing tools.
5 Save or export the images and analysis results.
Each time you apply a tool a new image is generated in the Documents Area. You can apply any number of processing or analysis tools in any order.
In Free Mode, user-created documents such as images, tables, forms, or reports are listed in the Documents Area. To have a good overview, the documents name is displayed permanently and the full name is displayed when you hover over it.
In the Documents Area, you can open a document by clicking on it. If you use a tool, it is ap- plied to the currently selected image (rather than the most recent image). The resulting image is added to the bottom of the Documents Area. From the context menu, you can also close, re- name or save documents.
Renaming Documents in the Documents Area
See also

7 Performing a Free Examination | 7.3 Documents ZEISS
In the Documents Area, the image and the image name is displayed permanently. The full name is visible via mouse over.
Saving Documents in the Documents Area
You can save one document or you multi-select documents to save them on a drive.
same name that is used in the Documents Area and on the Data Zone tab. Click OK 3. You can multi-select documents, right-click and select Save as. à The file browser opens. 4. To keep the documents names of each document, activate the Use names of Documents Area checkbox. If you deactivate the checkbox, all documents will have the name of the document to be saved on top in the Documents Area. For your overview, they are counted up. Check the name and type and change it, if necessary. If you have annotations in your image, you want to burn in, you can resize them between 1 and 1000000 % with the image. 5. Press [Enter] or click somewhere outside the document name to save the document.
Example:

Here, aaa is activated. The name is visible on the Data Zone tab. 2. Activate both images, and in one of them, right-click and select Save as. In the following dialog, do not activate the Use names of Documents Area checkbox.


7 Performing a Free Examination | 7.4 Selecting Workbenches ZEISS
In Free Mode you can change which workbenches are displayed in the Workbench Area. To be able to use the tools within a workbench it must be selected. However, you can add or remove a workbench from the Workbench Area at any time without affecting the examination results. The order of the workbenches also does not affect the examination results. Remove any work- benches you do not require to reduce the number of workbenches displayed in the Workbench Area.
To add a workbench to the Workbench Area:
To remove a workbench from the Workbench Area:
The next time you start a free examination the workspace is displayed as you left it.
2 Customizing Workspace [} 21]
The Free Mode workspace always starts with the same workbenches displayed in the Work- bench Bar as were used for the previous free examination.
§ If you have a set of workbenches that you commonly use for free examinations, you can sim- plify your work by adding them to the Workbench Bar.
§ Furthermore, if there are workbenches you rarely need, you can remove these from the Workbench Bar.
§ You can also modify existing workbenches by adding and removing tools.
By combining the above methods, you can configure the free examination workspace to your re- quirements.
2 Selecting Workbenches [} 21]
Reports enable you to summarize all the information from your examination in a single document. Typical information includes:

7 Performing a Free Examination | 7.7 Exporting Results ZEISS
§ Measurement data tables
§ Metadata (e.g. examination time, hardware setup)
Each report template contains placeholders for the above information to enable you to collate the information easily. The placeholders also ensure that each time the job is run, the same informa- tion is added to the report.
Prerequisite ü At least one report template is listed in the Add Templates tool.
displayed in the Center Screen Area. 2. Click the arrow icon in a placeholder and select the corresponding data that you wish to add, for example an image or a table containing measurement results, etc.. à As a rule you can add a single item to each placeholder. The image placeholder is an ex-
ception: you can add multiple images to a single image placeholder. Therefor simply se- lect multiple images from the list. The selected images are highlighted grey. à The report preview updates accordingly. 3. Repeat the above step until you have added information to all the placeholders. 4. Click Create Report to create the document in the Documents Area. à You can export the report from the Documents Area by using the context-menu. 5. If you require a paper copy of the template click Print Report.
You can export images or measurements results, e.g. to publish them or to archive them on an external storage device.
Alternatively, you can right-click a document (such as an image or report) in the Documents Area and use the context menu to export it.
§ Images

The archive is the central location for storing and managing result data and templates. Basically the archive can be split in three areas:
§ Area for organizing all kind of templates except job templates which is found under Manage Templates.
§ Area for all results which is found under Browse Job Results.
§ Area for all jobs to be managed under Job Mode.
Access to the items in the Archive depends on the current user's privileges, which can be set up in the software for each usergroup of the system. Technically the software supports the following archive types:
§ ZEN Data Storage Archive ZEN Data Storage provides a client/server database solution for microscopy customers who deal with the storage of large amounts of data originating from one or several microscopes. ZEN Data Storage allows the exchange of data and workflows and supports microscopists who want to separate image acquisition from post-acquisition work. In this way it also facilitates correlative workflows where the data of a sample can be accessed from a centralized location.
For more information (mainly relevant for Administrators) read Archive Options.
8 Archive ZEISS

Modifications reserved.
Carl Zeiss Microscopy GmbH Carl-Zeiss-Promenade 10 07745 Jena Germany
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.