USER MANUAL






Thanks for selecting the MT series; please read this manual carefully before
using the product.
Please keep this manual for future reference.
When you receive the product, check whether there is any damage that
occurred in transportation. Contact the transportation company or our company in time for any problem.
Please read this manual and safety information carefully before installing it.
Keep the product away from rain, exposure, severe dust, vibration,
corrosion, and intense electromagnetic interference.
Please avoid water, and other liquids enter into the product.
There are no user-serviceable parts inside the product. Do not disassemble
or attempt to repair it.

MT91 is a new generation of remote meters specially designed for the EPEVER inverters. It displays the real-time parameter of the inverter on one screen. Supporting parameter configuration by the button operations, which makes the product suitable for different requirements.
Dual interface design, friendly connection with the EPEVER inverter and other optional modules
LCD screen, real-time dynamic display of system data
Visually error codes, timely notification of warnings and faults
Load ON/OFF button to control the load output directly
Simple installation and friendly operation interface
Features


«In the real-time interface, long press for 2 seconds to turn off the load(default on); long-press it again for 2 seconds to turn on the load.


Definition of the inverter terminal/remote terminal:

Buzzer · Remote terminal · Inverter terminal

Connect the MT91 with an inverter:
Connect the MT91's "inverter terminal" and the inverter's RJ45 port through an RS485 communication cable (included accessory, model: CC- RJ45-3.81-100U. The cable length can be customized according to customers' actual requirement.)
Connect the MT91 with an auxiliary module
Connect the "remote terminal" of the MT91 and the auxiliary modules such as the Bluetooth module/wireless module/BMS through an adapter cable.

Surface mounting installation is recommended.
(no smaller than 77x52mm).


In the real-time interface (that is,
the default interface after the device is powered on), press it for 2s to enter the setting interface.
In the setting interface, press it for
2s to enter the specific parameter configuration interface.
In the real-time interface, press it
for 2s to turn on/off the load output (default on, press it for 2s to turn off the load output).
In the setting interface, press it for
2s to confirm the parameter configuration.
In the setting interface, click them to exit the parameter configuration interface. Press for
2s In the real-time interface, press them for 2s to clear the faults.
A long beep for parameter confirming and short beeps for other button operations.

In the real-time interface(namely, the default interface after the device is
powered on), please click or to display the below parameters in a
cycle.


The parameter configuration process is as follows.

Common parameters are shown in the following table:

12V:10.5V~14.2V; step size:0.1V 24V: 21V-30.2V; step size:0.1V 48V: 42V-62.4V; step size:0.1V

① After configuring the parameters marked with ①, the inverter will restart
automatically. It will resume work according to the new parameter value.
② NPower and IPower-Plus series support the modification of parameters
marked with ②. Please refer to the following rules for the modification; otherwise, the parameter setting will not succeed. IPower does not support modification of parameters marked with ②.
Rules for battery protection voltage:
A. Over voltage limiting voltage(16.2/32.2/64.4V) ≥ Over voltage
disconnect voltage ≥ Over voltage reconnect voltage +1V.
B. Over voltage reconnect voltage ≥ Low voltage reconnect voltage.
C. Low voltage reconnect voltage ≥ Low voltage disconnect voltage +1V.
D. Low voltage disconnect voltage ≥ Low voltage limiting
voltage(10.5/21/42V).

Detail status is shown as the following when reaching the protection voltage point.
The output is switched OFF. The blue indicator fast flashes.
Buzzer beeps. LCD displays the .
Over voltage reconnect The blue indicator is ON solid.
The output voltage is normal.
The output is switched OFF. The blue indicator slowly flashes.
Buzzer beeps.
LCD displays the .
Low voltage reconnect The blue indicator is ON solid.
The output voltage is normal.
function, the surge voltage is not higher than 20V for the 12V system, not higher than 40V for the 24V system, and not higher than 80V for the 48V system; otherwise, the inverter may be damaged.




Net Weight 65g


Any changes without prior notice! Version number: V1.1

HUIZHOU EPEVER TECHNOLOGY CO., LTD.
Huizhou Tel: +86-752-3889706
E-mail: [email protected]
Website: www.epsolarpv.com
www.epever.com