ET4001 Crimp machine and accessories

ET4001 is ideal for factory high performance machine operations, construction and mine locations. The ET4001 press offers crimping capabilities through 2” I.D. six spiral hose.
Weight 500 lbs.
Size 30”high, 22”deep, 12”wide
The Eaton ET4001P-002 power unit is ideally suited for use with the ET4001 press. It features a two-stage pump providing high flow at low pressure for fast ram approach and low flow at high pressure for actual crimping.
Dimensions 7½” high, 10” wide, 22” long
Weight 75 lbs.
Reservoir capacity 6 Quarts
Outlet port size ¾-16 Straight thread O-ring
Motor 1HP, 3450 RPM, 220 volts, 60 cycle, Single Phase
Hydraulic oil ISO 32 (SAE 10W)
Flow 2.6 GPM to 900 psi. 0.6 GPM above 900 psi
The ET4001P-002 Electric pump has the relief valve set at 5,000 psi. Damage to the press will result and the warranty may be voided if higher pressures are used. Requires individual 20 amp service breaker (220 v).
3 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E4 April 2021
ET4001 Crimp machine · Pressure 5000 psi

ET4001 Press and pump
Shop/Work table mounting instructions*
The following methods are offered as a guide and may be varied to suit your particular needs.
which may be used for lifting purposes (Figure 2). If these tapped holes are used, it is recommended that a minimum of two be utilized, preferably four. If two holes are used for lifting, use holes directly across from each other on the center line and not two on a diagonal. This will prevent press from tilting as it is raised.
Washers and nuts are installed from underneath. TIGHTEN.
Bench layout for ET4001 press

be taken to insure that the surface to which the press is bolted is capable of supporting the weight of the press (approximately 500 lbs.) and pump (approximately 75 lbs).
Lifting hole layout on ET4001 press top plate

Figure 4 Connection at top plate

Figure 5 Gauge installation
Cart (part number FF 91042) holes are pre- drilled. See page 5 for photo.


Figure 6 Hose connection

IT IS RECOMMENDED THAT THE PUMP BE ON AN INDIVIDUAL 20 AMP SERVICE OUTLET.
4 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E4 April 2021
Instructions · ET4001P-002 Outlet port

Refer to safety information regarding Eaton hose, hose fittings and assembly equipment compatibility on page 2.
Figure 8 Typical ET4001 equipment set-up on shop/work table
ET4001 on FF91042 cart


Cart, FF91042, holes are pre-drilled for ET4000, ET4001 or T-420 crimp machines
Check-out procedure for using electric pump ET4001P-002.
Throughout the Check-out procedure, check hose assembly/ adapter connections for any leaks. TIGHTEN if necessary. For-seal swivel nut torque for hose assembly; 32-35 ft. lbs.
Check oil level in power unit. The oil reservoir was filled at the factory; however, if oil is required, use ISO 32 (SAE 10W).
Do not cycle without base adapter ring in place.
Do not attempt to disconnect the hose sssemblies when the pusher is not fully retracted.
5 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E4 April 2021
Check out procedure

Eye protection required when press and pump are in use.




6 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E4 April 2021
Using ET4000AR-001

Using ET4000AR-002 for heavy 4-wire and 6-wire fittings (-24 thru -32 collets)
Eye protection required when press and pump are in use.








7 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E4 April 2021

Using T-410-25 adapter ring
Eye protection required when press and pump are in use.




PLACE appropriate side of spacer ring on top of collet with uncrimped hose assembly held in place.

8 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E4 April 2021

Spacer ring and nominal crimp diameter measurement

Typical spacer ring illustrating both sides of ring
Flat side Counterbore side

Nominal crimp diameter measurement

Measuring crimp diameters should be a part of the normal hose assembly procedure. To insure a proper crimp diameter reading, follow these steps:
Collet assembly lubrication Every 30 crimps = Re-lubricate sliding surfaces of dies
Every 250 crimps = Remove old grease and re-lubricate
Base adapter ring lubrication Every 250 crimps = Remove old grease and re-lubricate
Every 1,000 crimps = Remove old grease, inspect for
wear or damage and re-lubricate if okay.
9 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E4 April 2021
Spacer ring · Maintenance



Problem Cause Solutions (page 11)
Pump/motor does not start Blown fuse; Improper electrical hookup Step #1 (cut cord, loose wire, switch malfunctions) Motor starts but blows fuses High amps; Pusher doesn’t advance; Step #1 Pump binding or scored; cold oil Replace pump Motor runs - pusher does not advance Shuttle stuck open; Pump coupling sheared; Step #4 Pump unload valve stuck open Replace pump Check valve stuck shut Step #5 Motor runs - Pusher does not advance Solenoid malfunction Step #5 Motor runs - Pusher advances Pump unload valve stuck shut Replace pump but doesn’t develop final crimp pressure, blows fuse Motor runs - Pusher advances Relief valve leaking; Step #3 but doesn’t develop final crimp pressure Shuttle valve leaking; Step #4 Relief valve set low Step #3 Pusher won’t retract Shuttle valve stuck closed Step #4 Erratic pusher movement Low oil level; Step #2, Worn seal Replace pump Noisy pump; On start up only Low room temp. - Oil too thick; Use lighter weight oil (continuous) Air leaking - Low oil Level Step #2 Oil temperature hot Having unit operate at crimping psi too long; Operate for 3 seconds at crimp pressure; Low oil level: Step #2, Pump worn (longer cycle time); Replace pump, Leaking relief valve and /or shuttle valve Step #3, #4
10 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E4 April 2021
Front view · Back view

adjustment screw, spring and ball. Ball should be attached to spring. Check ball and seat for possible scoring. Replace spring and ball in cavity. Insert a small punch through spring against ball. Give punch a moderate tap to seat ball. Return adjustment screw to original position making sure adjustment screw is at least one turn from bottoming. Remove 1/4” NPTF plug from port above check valve and install a 6,000 psi pressure gage. With 6,000 psi pressure gauge in place, operate unit to full crimping position. Gauge should read approximately 5,000 psi. To raise setting, turn screw inward (clockwise); to lower, turn screw outward (counterclockwise) in ¼ turn increments. After each adjustment, recycle and read gauge for proper setting. Run a cycle of the crimping system for
final gauge reading before removing gauge and reinstalling pipe plug.
damage the O-ring seals. If cartridge disassembly is required use care in removing stem as it has a .0005 metal seal fit. Rotate stem in solvent and push from seat end to remove from cartridge. Do not lose the loose ball. Wash parts in clean solvent and examine for any surface markings. If necessary, polish with a fine crocus cloth. After final cleaning, reassembly cartridge. Shake cartridge and check for free movement of ball and stem. Replace cartridge if not functional at this point. Reassemble shuttle valve into its cavity and check crimping cycle prior to using system.
Step 4: Shuttle valve – If the shuttle valve is in a closed position and the ET4001 pusher will not retract, it may be helpful to tap the shuttle valve cap several times to dislodge any silt that may be causing the stem to bind. If this does not free the valve and allow the pusher to retract, use extreme caution prior to proceeding with shuttle valve removal as the system is still under pressure. It may be advisable to relieve pressure at a hose connection to avoid an oil bath. After pressure is removed from system, remove cap and valve cartridge. Soak cartridge in a PETROLEUM BASED SOLVENT ONLY (clean Stoddard solvent). Do not use Triethene, gasoline or paint thinner as they will
Item Number Qty. Part number Description
1 1 T-410-1M Micro switch 2 1 ET4000AR-001 Base adapter ring 3 1 ET4000AR-002 Base adapter ring 4 1 ET4000TP-0001 Locator bracket kit 5 1 ET4000TP-0002 Wear plate kit 6 1 ET4001C-0015 Blue shroud 7 8 120-00429 Screw, hex head 8 1 ET4001C-0006* Left hand pusher assembly 9 1 ET4001C-0005* Right hand pusher assembly
* must be ordered as a pair
11 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E4 April 2021
ET4001 Crimp machine

Eaton Hydraulics Group USA 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 952-937-9800 Fax: 952-294-7722 www.eaton.com/hydraulics
Eaton Hydraulics Group Europe Route de la Longeraie 7 1110 Morges Switzerland Tel: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601
Eaton Hydraulics Group Asia Pacific Eaton Building No.7 Lane 280 Linhong Road Changning District, Shanghai 200335 China Tel: (+86 21) 5200 0099 Fax: (+86 21) 2230 7240
© 2021 Eaton All Rights Reserved Printed in USA Document No. W-EQCR-TM022-E4 April 2021
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.