Barco NV Beneluxpark 21, 8500 Kortrijk, Belgium www.barco.com/en/support www.barco.com

All rights reserved. No part of this document may be copied, reproduced or translated. It shall not otherwise be recorded, transmitted or stored in a retrieval system without the prior written consent of Barco.
USB Type-CTM and USB-CTM are trademarks of USB Implementers Forum.
Brand and product names mentioned in this manual may be trademarks, registered trademarks or copyrights of their respective holders. All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufacturers.
The terms HDMI, HDMI High Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc.
As a global technology leader, Barco is committed to deliver secure solutions and services to our customers, while protecting Barco’s intellectual property. When product security concerns are received, the product security incident response process will be triggered immediately. To address specific security concerns or to report security issues with Barco products, please inform us via contact details mentioned on https://www.barco.com/psirt. To protect our customers, Barco does not publically disclose or confirm security vulnerabilities until Barco has conducted an analysis of the product and issued fixes and/or mitigations.
This product is covered by patents and/or pending patent applications. For more info: https://www.barco.com/en/about-barco/legal/patents
Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee. On receipt, the purchaser must immediately inspect all delivered goods for damage incurred during transport, as well as for material and manufacturing faults Barco must be informed immediately in writing of any complaints.
The period of guarantee begins on the date of transfer of risks, in the case of special systems and software on the date of commissioning, at latest 30 days after the transfer of risks. In the event of justified notice of complaint, Barco can repair the fault or provide a replacement at its own discretion within an appropriate period. If this measure proves to be impossible or unsuccessful, the purchaser can demand a reduction in the purchase price or cancellation of the contract. All other claims, in particular those relating to compensation for direct or indirect damage, and also damage attributed to the operation of software as well as to other services provided by Barco, being a component of the system or independent service, will be deemed invalid provided the damage is not proven to be attributed to the absence of properties guaranteed in writing or due to the intent or gross negligence or part of Barco.
If the purchaser or a third party carries out modifications or repairs on goods delivered by Barco, or if the goods are handled incorrectly, in particular if the systems are operated incorrectly or if, after the transfer of risks, the goods are subject to influences not agreed upon in the contract, all guarantee claims of the purchaser will be rendered invalid. Not included in the guarantee coverage are system failures which are attributed to programs or special electronic circuitry provided by the purchaser, e.g. interfaces. Normal wear as well as normal maintenance are not subject to the guarantee provided by Barco either.
The environmental conditions as well as the servicing and maintenance regulations specified in this manual must be complied with by the customer.

THIS PRODUCT SPECIFIC USER LICENSE AGREEMENT (EULA) TOGETHER WITH THE BARCO GENERAL EULA ATTACHED HERETO SET OUT THE TERMS OF USE OF THE SOFTWARE.
PLEASE READ THIS DOCUMENT CAREFULLY BEFORE OPENING OR DOWNLOADING AND USING THE SOFTWARE.
DO NOT ACCEPT THE LICENSE, AND DO NOT INSTALL, DOWNLOAD, ACCESS, OR OTHERWISE COPY OR USE ALL OR ANY PORTION OF THE SOFTWARE UNLESS YOU CAN AGREE WITH ITS TERMS AS SET OUT IN THIS LICENSE AGREEMENT.
Barco ClickShare (the “Software”) offered as a wireless presentation solution that includes the respective software components as further detailed in the applicable Documentation.
The Software can be used upon purchase from, and subject to payment of the relating purchase price to, a Barco authorized distributor or reseller of the ClickShare base unit and button or download of the authorized ClickShare applications (each a “Barco ClickShare Product”).
The Software is subject to the warranty conditions outlined in the Barco warranty rider. Maintenance, including the provision of upgrades and updates to the Software, and helpdesk support are available at your option on the terms of Barco’s then current warranty rider.
Higher maintenance and support levels can be obtained at the moment of product sale or during the Barco ClickShare Product and/or Software warranty term.
Higher maintenance and support levels may be included in the initial transaction if ordered and paid for additionally. It is strongly suggested to maintain the maintenance and support agreement without interruption. Barco reserves the right not to restart maintenance following an interruption by the customer.
The Software can be used as set out in the Barco EULA attached hereto.
The provisions of this Product Specific EULA override the Barco generic EULA in case of conflicts or inconsistencies.
In case of (inadvertent or other) non-compliance (e.g. where the actual use overshoots the use authorized hereunder), Barco shall have the option to suspend access to the Software until the non-compliance is remedied, failing of which Barco may terminate the License Agreement as set out herein.
You are controller for personal data which are being processed via the Software. Therefore, you remain solely responsible for complying with all applicable data protection laws and for implementing and maintaining privacy protection and security measures (especially for components that you provide or control). Barco disclaims any liability in this regard.
Barco created a specific privacy policy for the ClickShare software application for mobile devices, which describes the processing of personal data via this application ( http://www.barco.com/en/about-barco/legal/privacy-policy/clickshare-app).

copyright notices and, as relevant, source code access conditions apply as set out in the Barco EULA attached hereto. • Retention of data Barco right to use and retain Functional Information (section 10.2 of the EULA) shall survive the term of this EULA.
By accepting these terms (through tick box or other mechanism designed to acknowledge agreement to the terms of an electronic copy of this License Agreement), or by installing, downloading, accessing, or otherwise copying or using all or any portion of the Software (as defined below), (i) you accept this License Agreement on behalf of the entity for which you are authorized to act (e.g., your employer) and you agree to act in a manner consistent with this License Agreement (or, if there is no such entity for which you are authorized to act, you accept this License Agreement on behalf of yourself as an individual and acknowledge that you are legally bound by this Agreement), and (ii) you represent and warrant that you are duly empowered by the end user in case you act on behalf of such entity.
These terms apply to your use of the Software as of and for the original Term of your license. When you renew or purchase an additional license, the then current version of this License Agreement shall apply and will remain unchanged during the term of that license and/or in respect of such changed elements. The other contract documents (Product Specific EULA; Maintenance and Support Agreement, if and when provided alongside with this document) applies in addition to these terms and constitute the entire License Agreement. You acknowledge that an electronic copy of this Agreement shall have the same proving value as a hard copy signed by the parties.
If you are unwilling to accept this License Agreement on these terms, or you do not have the right, power and authority to act on behalf of and bind such entity (or yourself as an individual if there is no such entity), DO NOT SELECT THE “I ACCEPT” BUTTON OR OTHERWISE CLICK ON ANY BUTTON OR OTHER MECHANISM DESIGNED TO ACKNOWLEDGE AGREEMENT, AND DO NOT INSTALL, DOWNLOAD, ACCESS, OR OTHERWISE COPY OR USE ALL OR ANY PORTION OF THE SOFTWARE.
“Affiliate” means any corporation or other entity directly or indirectly, controlling, controlled by or under common control with such corporation or entity. For the purpose of the above, “control” shall mean (i) the ownership or control, directly or indirectly, of fifty percent (50%) or more of the equity capital or the shares or voting rights in the corporation or other entity in question or (ii) the control of the composition of the board of directors of the corporation or other entity in question.
“Barco” means Barco NV (company number 0473.191.041) with company address at Beneluxpark 21, 8500 Kortrijk, Belgium, or its designated Affiliate licensing to you the proprietary software which is the subject matter of this Agreement.
“Documentation” means all technical, reference and installation manuals, user guides, published performance specifications and other written documentation provided by Barco generally to its licensees with respect to the Software, along with any modifications and updates thereto;
“DRM” means Barco’s digital rights management platform used to provide access to and access conditions of the Software.
“License Agreement” means this Barco End User License Agreement (EULA), incorporating the terms of the Product Specific EULA, and any modifications thereof as set out herein.
“Product Specific EULA” means the supplemental software terms applicable
“Software” means the computer software, released in object code only, which is being licensed hereunder, as described in the applicable purchase order and related Product Specific EULA.
“Term” means the period set out in article 9.1 hereof, as well as any agreed renewal period.
“you” means the entity on behalf of which these terms are accepted, and any of its representatives having access to the Software.
2.1 ‘License Scope’. Subject to compliance with all license terms and payment of applicable fees, Barco grants you a limited, non-exclusive, non-assignable, non-transferable, non-sub-licensable license to use the Software exclusively in accordance with the conditions and parameters set forth herein. Save for the Product Specific EULA or any broader license terms confirmed through the DRM tool, the license under this License Agreement applies to one (1) copy of the Software to be used on one single computing device by one (1)

single user. Installation on a computing device that may be concurrently accessed by more than one user shall not constitute a permitted use and a separate license is required for each user connecting at the same time to a computing device on which the Software is being deployed.
2.2 ‘ License Type’. The applicable license type, and your rights in time, deployment and usage, are further detailed in the Product Specific EULA (in the absence of which the scope shall be as set in article 2.1 hereof).
2.3 ‘License restrictions’.
Intended Use. You agree to use the Software solely as permitted by this License Agreement (and any Product Specific EULA made part of it), by any applicable laws and in a matter consistent with its design and Documentation.
No Transfer (License Agreement). You agree not to transfer, assign or sublicense your license rights to any other person or entity, unless Barco’s prior written consent is obtained.
No Transfer (Software). If you deactivate or uninstall the Software from the computer device on which it was originally installed, this will terminate this License Agreement unless otherwise and specifically approved by Barco. You agree not to use the Software in association with other hardware or software that allows to pool connections, reroute information or in any other way enables to breach or circumvent the license restrictions by enabling the deployment and use of the Software by more than the authorized number of devices or users (e.g. multiplexing) or otherwise attempts to reduce the number of licenses actually required.
Authorized Users. The use of the Software is restricted to persons within your organization, or any third party representatives operating under your responsibility and control, provided any such persons have accepted the terms of this License Agreement. You agree not to use or permit the Software to be used to perform services for third parties, whether on a service bureau or time sharing basis or otherwise, without the prior written authorization of Barco. You shall not lease, rent, sell or otherwise transfer or grant a security or other interest in the Software.
No Modifications. You shall not make error corrections to or otherwise modify or adapt the Software or create derivative works based upon the Software, or permit third parties to do the same.
No Reverse Engineering. You agree not to reverse engineer or decompile, decrypt, disassemble or otherwise reduce the Software to human-readable form, except to the extent otherwise expressly permitted under applicable law notwithstanding this restriction, or except to the extent Barco is legally required to permit such specific activity pursuant to any applicable open source license.
Code required to ensure interoperability. To the extent required by law, and at your written request, Barco shall provide you with the interface information needed to achieve interoperability between the Software and another independently created programs used by you, on payment of Barco’s applicable fee (if any). You shall observe strict obligations of confidentiality with respect to such information and shall use such information in compliance with terms and conditions which Barco makes applicable.
No Unbundling. The Software may include various applications and components, may support multiple platforms and languages, and may be provided on multiple media or in multiple copies. Nonetheless, the Software is designed and provided to you as a single product to be used as a single product on devices as permitted herein. You agree not to unbundle the component parts of the Software for use on different computer devices.
Territory. You agree to use the Software solely in the territory or region where you obtained the Software from Barco or its authorized reseller or as otherwise stated in the Documentation. Any export if permitted shall comply with any applicable (export) laws and regulations.
2.4 ‘Your Infrastructure’. You remain responsible to procure and maintain hardware, operating system, network and other infrastructure (the “Infrastructure”) required to operate the Software and to keep such Infrastructure functioning and virus-free. You acknowledge that the Software is a complex computer software application, and that the performance thereof may vary depending hardware platform, software interactions and configuration. You acknowledge that the Software is not designed and produced specifically to meet your requirements and expectations and the selection of the Software by you is entirely your own choice and decision.
3.1 ‘Ownership’. Any Software is licensed, not sold to you, on a non-exclusive basis for use only under the terms of this License Agreement, and Barco and its suppliers reserve all rights not expressly granted to you. You may own the carrier on which the Software is provided, but the Software is owned and copyrighted by Barco or by third party suppliers. Your license confers no title or ownership and is not a sale of any rights in the Software or its Documentation.

3.2 ‘Third Party Materials’. The Software may contain or require the use of certain third party technology (whether proprietary or open source software), identified by Barco in the Documentation, readme file, third- party click-accept, on www. barco. com or elsewhere (the “Identified Components”). Identified Components may be subject to additional and/or different terms and you agree that the Identified Components are licensed under the terms, disclaimers and warranties of their respective licenses which in the forthcoming case shall override the provisions of this License Agreement.
3.3 ‘Source Code Access’. To the extent required under third party (open source) license terms, and for a period of 36 months following your acceptance of this License Agreement, Barco shall provide access to the source code controlled by a third party (open source) license, via email or download link. If the relevant license terms require so, you may require Barco (attn. its legal department, at the address stated above) to obtain such code on tangible medium against payment of the cost of media, shipping and handling.
3.4 ‘Trademarks / Copyright’. Any brand and product names mentioned in relation to the Software may be trademarks, registered trademarks or copyrights of their respective (third party) holders. In addition, the Software is protected by national and international laws and treaty provisions. Copyright on the Software components belongs to the respective initial copyright holder, each additional contributor and/or their respective assignee(s), as may be identified in the Software Documentation, source code, README file, or otherwise. You shall not remove or obscure or otherwise alter any trademark, copyright or other proprietary notices, legends or logo’s placed on or contained within the Software.
3.5 ‘Trade Secrets’. You acknowledge that the Software embodies valuable trade secrets of Barco and its third party licensors and agree not to disclose, provide or otherwise make available such trade secrets contained within the Software and Documentation in any form to any third party without the prior written consent of Barco. You shall implement all reasonable security measures to protect such trade secrets.
4.1 ‘Principle’. Barco is under no obligation to provide support and maintenance in respect of the Software, except as included in a Product Specific EULA and/or to the extent you have entered into a separate maintenance and support agreement and paid applicable maintenance and support fees. Any unauthorized use of the Software, as specified in any maintenance and support agreement, may prohibit Barco from providing such support and maintenance.
4.2 ‘Support policy’. Maintenance releases updates or upgrades can be obtained under the terms of a separate maintenance and support agreement which is being offered to you. Such agreements, together with the support included in a Product Specific EULA, include Barco’s sole liability and your sole remedy in respect of the support and maintenance of the Software. You agree to install any maintenance releases to address bugs or security issues in the Software if the same are being provided to you. Barco will keep you informed as of when earlier versions of the Software are no longer serviced.
4.3 ‘Remote connectivity’. Barco may require, as a material condition to provide maintenance or support, that the Software remains remotely connected with Barco over a network.
EXCEPT FOR THE LIMITED WARRANTY THAT MAY APPLY AS PER THE PRODUCT SPECIFIC EULA, YOU UNDERSTAND THAT THE SOFTWARE IS BEING PROVIDED TO YOU "AS IS". BARCO DOES NOT MAKE NOR INTENDS TO MAKE ANY WARRANTIES OR REPRESENTATIONS, EXPRESS OR IMPLIED AND SPECIFICALLY DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT OF INTELLECTUAL PROPERTY AND DOES NOT WARRANT THAT THE SOFTWARE WILL BE FREE FROM ERRORS OR THAT YOU WILL BE ABLE TO OPERATE THE SOFTWARE WITHOUT INTERRUPTIONS OR THAT SUCH ERRORS WILL BE CORRECTED BY BARCO. EXCEPT FOR ANY MAINTENANCE AND SUPPORT OBLIGATIONS SEPARATELY AGREED, YOU ARE SOLELY RESPONSIBLE FOR ALL COSTS AND EXPENSES ASSOCIATED WITH RECTIFICATION, REPAIR OR DAMAGE CAUSED BY SUCH ERRORS. IN THE FORTHCOMING CASE, THE WARRANTY DISCLAIMER FOUND IN APPLICABLE OPEN SOURCE LICENSES SHALL OVERRIDE THE PROVISIONS OF THIS LICENSE AGREEMENT.
6.1 ‘Reporting and Audit’. In addition to good practice record-keeping obligations, you agree to report the use of the Software and relating billing metrics in the DRM or otherwise as agreed. You grant to Barco and its designated auditors, at Barco’s expenses, the right to verify your deployment and use of the Software during your normal business hours so as to verify your compliance with the License Agreement. In the event such audit reveals non-compliance with your payment obligations hereunder, you shall promptly pay to Barco the appropriate license fees plus the reasonable cost of conducting the audit.

6.2 ‘Fair Use Monitor’. You are informed and acknowledge that the Software includes technology which allows to remotely decrease (in part or in full) the functionality of the Software (the “Fair Use Monitor”). Such technology is an enabling tool and a material condition precedent for Barco to enter into this License Agreement.
6.3 ‘Enforcement’. Upon breach of the License Agreement (including overdue payment), Barco shall inform the then known user, through the DRM or otherwise in writing, (i) which condition of the License Agreement (including payment terms) is violated; (ii) allow a period of 8 calendar days to cure such breach, if it can be cured at all; and (iii) inform which part of the functionality Barco intends to reduce (all Software or certain additionally licensed features only; in part or in full) if the breach is not remedied on time and in full.
6.4 ‘Remedy’. If the breach is not cured within the applicable remedy period (or cannot be cured at all), Barco shall have the option (i) to cause you to procure such additional licenses required as per the actual usage; (ii) to reduce the Software’s functionality, including through the use of the Fair Use Monitor; or (iii) to terminate the License Agreement as set out herein, without prejudice to any other remedies available at law, under contract or in equity.
6.5 ‘Indemnification’. YOU HEREBY AGREE TO INDEMNIFY, DEFEND AND HOLD HARMLESS BARCO AND BARCO’S AFFILIATES FROM AND AGAINST ANY AND ALL ACTIONS, PROCEEDINGS, LIABILITY, LOSS, DAMAGES, FEES AND COSTS (INCLUDING ATTORNEY FEES), AND OTHER EXPENSES INCURRED OR SUFFERED BY BARCO ARISING OUT OF OR IN CONNECTION WITH ANY BREACH BY YOU OF THE TERMS OF THIS SOFTWARE LICENSE.
TO THE MAXIMUM EXTENT PERMITTED BY LAW, BARCO ACCEPTS NO LIABILITY FOR ANY DAMAGES, LOSSES OR CLAIMS YOU OR ANY THIRD PARTY MAY SUFFER AS A RESULT OF YOUR USE OF THE SOFTWARE. IN JURISIDCTIONS WHERE BARCO’S LIABILITY CANNOT BE EXCLUDED, BARCO’S LIABILITY FOR DIRECT DAMAGES SHALL BE LIMITED TO THE LICENSE FEES ACTUALLY PAID FOR THE SOFTWARE DURING THE TWELVE MONTHS PRECEEDING THE CLAIM (OR AN AMOUNT OF 250 EURO IF NO FEE WOULD BE PAID) IN THE AGREGATE.
TO THE MAXIMUM EXTENT PERMITTED BY LAW, IN NO EVENT WILL BARCO BE LIABLE FOR ANY INDIRECT, SPECIAL, PUNITIVE, INCIDENTAL OR CONSEQUENTIAL LOSS OR DAMAGES OF ANY KIND WHICH MAY ARISE OUT OF OR IN CONNECTION WITH THE SOFTWARE, THIS SOFTWARE LICENSE OR THE PERFORMANCE OR PURPORTED PERFORMANCE OF OR FAILURE IN THE PERFORMANCE OF BARCO’S OBLIGATIONS UNDER THIS SOFTWARE LICENSE OR FOR ANY ECONOMIC LOSS, LOSS OF BUSINESS, CONTRACTS, DATA, GOODWILL, PROFITS, TURNOVER, REVENUE, REPUTATION OR ANY LOSS ARISING FROM WORK STOPPAGE, COMPUTER FAILURE OR MALFUNCTION OF THE SOFTWARE AND ANY AND ALL OTHER COMMERCIAL DAMAGES OR LOSSES WHICH MAY ARISE IN RESPECT OF USE OF THE SOFTWARE, EVEN IF BARCO HAS BEEN ADVISED OF THE POSSIBILITY OF THEIR OCCURRENCE.
8.1 ‘Confidential Information’. You will be receiving information which is proprietary and confidential to Barco during the procurement and Term of this License Agreement. “Confidential Information” shall include (i) the underlying logic, source code and concepts of the Software or other trade secrets (the access to which is strictly limited as expressly set out herein), (ii) any information designated as confidential by Barco or which has the necessary quality of confidence about it and (iii) any license key provided by Barco to you hereunder.
8.2 ‘Non-Disclosure’. You agree not to divulge any Confidential Information to any persons without Barco's prior written consent provided that this article 8 shall not extend to information which was rightfully in your possession prior to the commencement of this License Agreement, which is already public knowledge or becomes so at a future date (otherwise than as a result of a breach of this article 8), to the extent it is required to be disclosed by law or which is trivial or obvious. You agree not to use any Confidential Information except for the authorized purpose hereunder. The foregoing obligations as to confidentiality shall survive the Term of this License Agreement.
9.1 ‘Term’. The duration of this License Agreement will be from the date of your acceptance (as set forth above) of the Software (whereby you acknowledge that use of the Software implies acceptance), until you de- activate the Software, discontinue the use of the device on which the Software was first installed for its intended use or the expiration of the limited time period set out in the Product Specific EULA, whichever comes first.
9.2 ‘Termination’. You may terminate this License Agreement at any time by destroying all copies of the Software then in your possession and destroying all Documentation and associated materials, or returning the

same to Barco or the appointed Barco reseller that sold or provided these to you. Barco may terminate this License Agreement, immediately or gradually in accordance with article 6 hereof, by informing you at any time if any user is in breach of any of the License Agreement's terms.
9.3 ‘Consequences of Termination’. All rights associated with the use of the Software and the acquisition of updates and upgrades cease once the License Agreement is terminated or expires. Termination or expiry of your license will not entitle you to any retroactive refund of current or past payments.
10.1 ‘Personal Data’. Whether or not Barco assumes the role of processor of personal data (as stated in the Product Specific EULA), you remain solely responsible for complying with all applicable data protection laws and for implementing and maintaining privacy protection and security measures (especially for components that you provide or control). Barco disclaims any liability for any data not provided by Barco, or any use of the Software outside the intended use as per this License Agreement or an applicable data processing annex.
10.2 ‘Functional Information’. Via the Software, Barco may gather technical information about (i) the functioning and the functionality of the products which are connected through the Software, and/or (ii) as provided by you or generated by your use of the Software (“Functional Information”). Barco may make use of such Functional Information for purposes of analytics, for developing and improving products and services, offering products and services to your organization and/or allowing third parties to access such Functional Information; based on the legitimate interest of Barco of evaluating the market, assessing and improving its products and conducting research and development. All knowhow, inventions and works derived by Barco from the Functional Information will be exclusively owned by Barco.
11.1 ‘Entire Agreement’. This License Agreement is the only understanding and agreement between you and Barco for use of the Software. This License Agreement supersedes all other communications, understandings or agreements we had prior to this License Agreement (with the exception of any continuing confidentiality agreement).
11.2 ‘Notices’. Notices can be validly delivered through the DRM and alternatively or additionally to the parties’ last known address.
11.3 ‘Severability’. This License Agreement shall not be altered, amended or varied, except by written agreement signed by its parties. If any provision of this License Agreement is determined to be illegal, void or unenforceable, or if any court of competent jurisdiction in any final decision so determines, this License Agreement shall continue in full force save that such provision shall be deemed to be deleted with effect from the date of such decision, or such earlier date, and shall be replaced by a provision which is acceptable by law and which embodies the intention of this License Agreement a close as possible.
11.4 ‘Export’. You acknowledge that this Software may be subject to U.S. or other governments’ Export control laws and regulations. You agree to comply with all applicable international and national laws that apply to the Software, including the U.S. Export Administration Regulations, as well as end-user, end-use, and destination restrictions issued by the U.S. or other governments.
11.5 ‘Survival’. The provisions of articles 3, 5, 6, 7, 8, 10 and 11 will survive the termination of this License Agreement, howsoever caused, but this will not imply or create any continued right to use the Software after termination of this License Agreement.
11.6 ‘Assignment’. You are not allowed to assign this Agreement in part or in full to any third party without Barco’s consent. Barco shall be entitled to assign all or any of Barco's obligations hereunder to a third party and/or any of Barco's Affiliates.
11.7 ‘Law and Jurisdiction’. The construction, validity and performance of this License Agreement shall be governed in all respects by the laws of Belgium, without recourse to its conflict of law principles. All disputes arising in any way out of or affecting this License Agreement shall be subject to the exclusive jurisdiction of the courts of Kortrijk (Belgium), without prejudice to enforcement of any judgment or order thereof in any other jurisdiction. The United Nations Convention on Contracts for the International Sale of Goods (the "Convention") shall not apply to this License Agreement, however, if the Convention is deemed by a court of competent jurisdiction to apply to this License Agreement, Barco shall not be liable for any claimed non- conformance of the Software under Article 35(2) of the Convention.
YOU HEREBY ACKNOWLEDGE TO HAVE READ, UNDERSTOOD AND ACCEPTED TO BE BOUND BY ALL THE TERMS AND CONDITIONS OF THIS LICENCE AGREEMENT AS INDICATED ABOVE

You are controller for personal data which are being processed via the Software. Therefore, you remain solely responsible for complying with all applicable data protection laws and for implementing and maintaining privacy protection and security measures (especially for components that you provide or control). Barco disclaims any liability in this regard. Barco created a specific privacy policy for the ClickShare software application for mobile devices, which describes the processing of personal data via this application ( http://www.barco.com/en/about-barco/legal/privacy-policy/clickshare-app).
Via the Software, Barco may gather technical information about (i) the functioning and the functionality of the products which are connected through the Software, and/or (ii) as provided by you or generated by your use of the Software (“Functional Information”). Barco may make use of such Functional Information for purposes of analytics, for developing and improving products and services, offering products and services to your organization and/or allowing third parties to access such Functional Information; based on the legitimate interest of Barco of evaluating the market, assessing and improving its products and conducting research and development. All knowhow, inventions and works derived by Barco from the Functional Information will be exclusively owned by Barco.
This product contains software components released under an Open Source license. A copy of the source code is available on request by contacting your Barco customer support representative.
EACH SEPARATE OPEN SOURCE SOFTWARE COMPONENT AND ANY RELATED DOCUMENTATION ARE PROVIDED "AS IS"WITHOUT EXPRESS OR IMPLIED WARRANTY INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL THE COPYRIGHTHOLDER OR ANY OTHER CONTRIBUTOR BE LIABLE FOR DIRECT, INCIDENTAL, SPECIAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS OPEN SOURCE SOFTWARE. MORE INFORMATION/ DETAILS IS TO BE FOUND IN EACH SPECIFIC OPEN SOURCE LICENSE.
Copyright on each Open Source Software component belongs to the respective initial copyright holder, each additional contributor and/or their respective assignee (s), as may be identified in the respective documentation, source code, README file, or otherwise. You shall not remove or obscure or otherwise alter the respective copyrights.
You acknowledge living up to the conditions of each separate Open Source Software license.
In the development of the Software, the following Open Source Software components have been used:
alsa-lib 1.1.7 ftp://ftp.alsa-project.org/pub/lib
alsa-utils 1.1.7 ftp://ftp.alsa-project.org/pub/utils
libsamplerate 0.1.9 http://www.mega-nerd.com/SRC
libsndfile 1.0.28 http://www.mega-nerd.com/libsndfile/files
ncurses 6.1 http://ftpmirror.gnu.org/ncurses
avahi 0.7 https://github.com/lathiat/avahi/releases/download/v0.7
dbus 1.12.16 https://dbus.freedesktop.org/releases/dbus
expat 2.2.7 http://downloads.sourceforge.net/project/expat/expat/2.2.7
libselinux 2.8 https://raw.githubusercontent.com/wiki/SELinuxProject/selinux/files/ releases/20180524
libsepol 2.8 https://raw.githubusercontent.com/wiki/SELinuxProject/selinux/files/ releases/20180524
pcre 8.42 https://ftp.pcre.org/pub/pcre
python3 3.7.4 https://python.org/ftp/python/3.7.4

bluez5_utils- headers 5.50 https://cdn.kernel.org/pub/linux/bluetooth
libffi v3.3-rc0 https://github.com/libffi/libffi/archive/v3.3-rc0
libzlib 1.2.11 http://www.zlib.net
libdaemon 0.14 http://0pointer.de/lennart/projects/libdaemon
libglib2 2.56.4 http://ftp.gnome.org/pub/gnome/sources/glib/2.56
elfutils 0.176 https://sourceware.org/elfutils/ftp/0.176
bzip2 1.0.8 https://sourceware.org/pub/bzip2
util-linux 2.33 https://cdn.kernel.org/pub/linux/utils/util-linux/v2.33
linux-pam 1.3.1 https://github.com/linux-pam/linux-pam/releases/download/v1.3.1
flex 2.6.4 https://github.com/westes/flex/files/981163
readline 8.0 http://ftpmirror.gnu.org/readline
bc 1.06.95 http://alpha.gnu.org/gnu/bc
bellagio 0.9.3 http://downloads.sourceforge.net/project/omxil/omxil/Bellagio%200.9.3
bitstream 1.4 https://get.videolan.org/bitstream/1.4
bluez5_utils 5.50 https://cdn.kernel.org/pub/linux/bluetooth
libical 1.0.1 https://github.com/libical/libical/releases/download/v1.0.1
eudev 3.2.7 http://dev.gentoo.org/~blueness/eudev
kmod 25 https://cdn.kernel.org/pub/linux/utils/kernel/kmod
boost 1.69.0 http://downloads.sourceforge.net/project/boost/boost/1.69.0
icu 60.2 http://download.icu-project.org/files/icu4c/60.2
bridge-utils 1.6 https://cdn.kernel.org/pub/linux/utils/net/bridge-utils
busybox 1.29.3 http://www.busybox.net/downloads
dosfstools 4.1 https://github.com/dosfstools/dosfstools/releases/download/v4.1
e2fsprogs 1.44.5 https://cdn.kernel.org/pub/linux/kernel/people/tytso/e2fsprogs/v1.44.5
iproute2 4.19.0 https://cdn.kernel.org/pub/linux/utils/net/iproute2
iptables 1.8.2 https://netfilter.org/projects/iptables/files
netcat 0.7.1 http://downloads.sourceforge.net/project/netcat/netcat/0.7.1
ntp 4.2.8p13 https://www.eecis.udel.edu/~ntp/ntp_spool/ntp4/ntp-4.2
libedit 20180525-3.1 http://www.thrysoee.dk/editline
libbsd 0.10.0 https://libbsd.freedesktop.org/releases
libevent 2.1.8-stable https://github.com/libevent/libevent/releases/download/release-2.1.8- stable
libopenssl 1.1.1c https://www.openssl.org/source
pciutils 3.5.5 https://cdn.kernel.org/pub/software/utils/pciutils

unzip 60 ftp://ftp.info-zip.org/pub/infozip/src
usbutils 010 https://cdn.kernel.org/pub/linux/utils/usb/usbutils
libusb 1.0.22 https://github.com/libusb/libusb/releases/download/v1.0.22
c-ares 1.15.0 http://c-ares.haxx.se/download
ca-certificates 20190110 http://snapshot.debian.org/archive/debian/20190513T145054Z/pool/ main/c/ca-certificates
cairo 1.15.12 http://cairographics.org/snapshots
fontconfig 2.13.1 http://fontconfig.org/release
freetype 2.9.1 http://download.savannah.gnu.org/releases/freetype
libpng 1.6.37 http://downloads.sourceforge.net/project/libpng/libpng16/1.6.37
libdrm 2.4.97 https://dri.freedesktop.org/libdrm
libpthread- stubs 0.4 http://xcb.freedesktop.org/dist
pixman 0.34.0 http://xorg.freedesktop.org/releases/individual/lib
wayland 1.16.0 http://wayland.freedesktop.org/releases
libxml2 2.9.9 http://xmlsoft.org/sources
collectd 5.7.2 http://collectd.org/files
libgcrypt 1.8.4 https://gnupg.org/ftp/gcrypt/libgcrypt
libgpg-error 1.33 https://www.gnupg.org/ftp/gcrypt/libgpg-error
lm-sensors V3-5-0 https://github.com/lm-sensors/lm-sensors/archive/V3-5-0
crda 4.14 https://git.kernel.org/pub/scm/linux/kernel/git/mcgrof/crda.git/snapshot
libnl 3.4.0 https://github.com/thom311/libnl/releases/download/libnl3_4_0
cryptsetup 2.0.6 https://cdn.kernel.org/pub/linux/utils/cryptsetup/v2.0
json-c 0.13.1 https://s3.amazonaws.com/json-c_releases/releases
lvm2 2.02.183 ftp://sources.redhat.com/pub/lvm2
libaio 0.3.111 https://releases.pagure.org/libaio
popt 1.16 http://rpm5.org/files/popt
dhcp 4.3.6 http://ftp.isc.org/isc/dhcp/4.3.6
dnsmasq 2.79 http://thekelleys.org.uk/dnsmasq
dropbear 2018.76 https://matt.ucc.asn.au/dropbear/releases
dvblast 3.4 https://get.videolan.org/dvblast/3.4
libev 4.24 http://dist.schmorp.de/libev/Attic
faad2 2.8.8 http://downloads.sourceforge.net/project/faac/faad2-src/faad2-2.8.0
fbv 1.0b http://s-tech.elsat.net.pl/fbv
giflib 5.1.4 http://downloads.sourceforge.net/project/giflib

jpeg-turbo 2.0.1 https://downloads.sourceforge.net/project/libjpeg-turbo/2.0.1
ffmpeg 4.1.3 http://ffmpeg.org/releases
libva 2.4.0 https://github.com/intel/libva/releases/download/2.4.0
libvorbis 1.3.6 http://downloads.xiph.org/releases/vorbis
libogg 1.3.3 http://downloads.xiph.org/releases/ogg
libvpx v1.7.0 https://github.com/webmproject/libvpx/archive/v1.7.0
opus 1.3.1 https://downloads.xiph.org/releases/opus
speex 1.2.0 https://downloads.xiph.org/releases/speex
20e- d3452074664a- d07e380- e51321b148a- cebdf20 https://git.xiph.org/speexdsp.git
file 5.36 ftp://ftp.astron.com/pub/file
gdb 8.1.1 http://ftpmirror.gnu.org/gdb
gnupg2 2.2.17 https://gnupg.org/ftp/gcrypt/gnupg
libassuan 2.5.2 ftp://ftp.gnupg.org/gcrypt/libassuan
libksba 1.3.5 ftp://ftp.gnupg.org/gcrypt/libksba
libnpth 1.6 https://www.gnupg.org/ftp/gcrypt/npth
sqlite 3280000 https://www.sqlite.org/2019
gssdp 1.0.2 http://ftp.gnome.org/pub/gnome/sources/gssdp/1.0
libsoup 2.62.3 http://ftp.gnome.org/pub/gnome/sources/libsoup/2.62
gst1-libav 1.14.4 https://gstreamer.freedesktop.org/src/gst-libav
gst1-plugins- base 1.14.4 https://gstreamer.freedesktop.org/src/gst-plugins-base
gstreamer1 1.14.4 https://gstreamer.freedesktop.org/src/gstreamer
gst1-plugins- bad 1.14.4 https://gstreamer.freedesktop.org/src/gst-plugins-bad
wayland- protocols 1.17 http://wayland.freedesktop.org/releases
gst1-plugins- good 1.14.4 https://gstreamer.freedesktop.org/src/gst-plugins-good
libv4l 1.16.3 https://linuxtv.org/downloads/v4l-utils
qt5base 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
libinput 1.12.5 http://www.freedesktop.org/software/libinput
libevdev 1.6.0 http://www.freedesktop.org/software/libevdev
mtdev 1.1.4 http://bitmath.org/code/mtdev
pcre2 10.32 https://ftp.pcre.org/pub/pcre
speexdsp

gst1-vaapi 1.14.4 https://gstreamer.freedesktop.org/src/gstreamer-vaapi
htop 2.2.0 http://hisham.hm/htop/releases/2.2.0
hwdata v0.308 https://github.com/vcrhonek/hwdata/archive/v0.308
input-event- daemon v0.1.3 https://github.com/gandro/input-event-daemon/archive/v0.1.3
iperf3 3.6 https://downloads.es.net/pub/iperf
iw 4.14 https://cdn.kernel.org/pub/software/network/iw
jansson 2.12 http://www.digip.org/jansson/releases
jose 10 https://github.com/latchset/jose/releases/download/v10
json-for- modern-cpp v3.5.0 https://github.com/nlohmann/json/archive/v3.5.0
jsoncpp 1.8.4 https://github.com/open-source-parsers/jsoncpp/archive/1.8.4
libarchive 3.3.3 http://www.libarchive.org/downloads
libconfig v1.7.2 https://github.com/hyperrealm/libconfig/archive/v1.7.2
libcurl 7.65.3 https://curl.haxx.se/download
libestr 0.1.10 http://libestr.adiscon.com/files/download
libfastjson v0.99.8 https://github.com/rsyslog/libfastjson/archive/v0.99.8
libhttpparser v2.9.0 https://github.com/nodejs/http-parser/archive/v2.9.0
liblogging 1.0.6 http://download.rsyslog.com/liblogging
libnspr 4.20 https://ftp.mozilla.org/pub/mozilla.org/nspr/releases/v4.20/src
libnss 3.42.1 https://ftp.mozilla.org/pub/mozilla.org/security/nss/releases/NSS_3_42_ 1_RTM/src
libopusenc 0.2.1 https://downloads.xiph.org/releases/opus
libpcap 1.9.0 http://www.tcpdump.org/release
libqrencode 4.0.0 http://fukuchi.org/works/qrencode
libsha1 0.3 https://github.com/dottedmag/libsha1/archive/0.3
libtool 2.4.6 http://ftpmirror.gnu.org/libtool
libuv v1.25.0 https://github.com/libuv/libuv/archive/v1.25.0
libxkbcommon 0.8.2 http://xkbcommon.org/download
libyaml 0.2.1 http://pyyaml.org/download/libyaml
libzip 1.5.1 http://www.nih.at/libzip
lighttpd 1.4.53 http://download.lighttpd.net/lighttpd/releases-1.4.x
logrotate 3.13.0 https://github.com/logrotate/logrotate/archive/3.13.0
memtester 4.3.0 http://pyropus.ca/software/memtester/old-versions
monit 5.25.3 http://mmonit.com/monit/dist

netsnmp 5.8 https://downloads.sourceforge.net/project/net-snmp/net-snmp/5.8
nodejs 8.15.1 http://nodejs.org/dist/v8.15.1
opkg 0.3.6 http://downloads.yoctoproject.org/releases/opkg
opus-tools 0.2 https://downloads.xiph.org/releases/opus
opusfile 0.11 https://downloads.xiph.org/releases/opus
php 7.3.9 http://www.php.net/distributions
v190600_ 20161030 http://www.portaudio.com/archives
powertop 2.9 https://01.org/sites/default/files/downloads/powertop
protobuf v2.6.1 https://github.com/google/protobuf/archive/v2.6.1
https://files.pythonhosted.org/packages/a8/c6/ a8d1555e795dbd0375c3c93b576ca13bbf139db51ea604a- fa19a2c35fc03
python- pyyaml 4.2b4
https://files.pythonhosted.org/packages/cc/74/ 11b04703ec416717b247d789103277269d567db575d2fd88f25d9767f- e3d
python-serial 3.4
qt5declarative 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5xmlpat- terns 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5graphica- leffects 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5imagefor- mats 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5multimedia 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5quickcon- trols 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5quickcon- trols2 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5serialport 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5svg 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5tools 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5webchan- nel 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5websock- ets 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
qt5webengine 5.12.4 https://download.qt.io/archive/qt/5.12/5.12.4/submodules
webp 1.0.1 http://downloads.webmproject.org/releases/webp
ramspeed 2.6.0 http://www.alasir.com/software/ramspeed
rsync 3.1.3 http://rsync.samba.org/ftp/rsync/src
rsyslog 8.22.0 http://rsyslog.com/files/download/rsyslog
portaudio

strace 4.26 https://strace.io/files/4.26
tcpdump 4.9.2 http://www.tcpdump.org/release
tpm-tools 1.3.9.1 http://downloads.sourceforge.net/project/trousers/tpm-tools/1.3.9.1
trousers 0.3.14 http://downloads.sourceforge.net/project/trousers/trousers/0.3.14
tzdata 2018e http://www.iana.org/time-zones/repository/releases
weston 5.0.0 http://wayland.freedesktop.org/releases
wireless- regdb 2019.06.03 https://cdn.kernel.org/pub/software/network/wireless-regdb
wireless_tools 30.pre9 https://hewlettpackard.github.io/wireless-tools
xkeyboard- config 2.23.1 http://www.x.org/releases/individual/data/xkeyboard-config
zip 30 ftp://ftp.info-zip.org/pub/infozip/src
splashutils 1.5.4.4 http://dev.gentoo.org/~spock/projects/gensplash/archive
libresample 0.1.3 ftp://ftp.ubuntu.com/ubuntu/pool/universe/libr/libresample
5_4-2016q3- 20160926 https://launchpad.net/gcc-arm-embedded/5.0/5-2016-q3-update/ +download
alsa-plugins 1.1.1 ftp://ftp.alsa-project.org/pub/plugins
arphic-uming- fonts 20080216 http://archive.ubuntu.com/ubuntu/pool/main/t/ttf-arphic-uming
dejavu-fonts 2.34 http://downloads.sourceforge.net/project/dejavu/dejavu/2.34
sazanami- fonts 20040629 http://sourceforge.jp/projects/efont/downloads/10087
unfonts 1.0 http://kldp.net/frs/download.php/1425
liblockfile 1.09 http://snapshot.debian.org/archive/debian/20151026T153523Z/pool/ main/libl/liblockfile
lockfile-progs 0.1.17 http://snapshot.debian.org/archive/debian/20141023T043132Z/pool/ main/l/lockfile-progs
37c86e60c0442- fef570b75c- d81aeb1db4d0- cbafd git://git.kernel.org/pub/scm/linux/kernel/git/cjb/mmc-utils.git
usbmount 0.0.22 http://snapshot.debian.org/archive/debian/20141023T043132Z/pool/ main/u/usbmount
json 1.8.4-cs2 http://json.org/
flexnet 1.0.5 https://www.flexerasoftware.com/monetize/products/flexnet-licensing html
qca6174a-30 4.5.25.38 https://source.codeaurora.org/external/wlan/qcacld-2.0
a5ffe45908- cae43925bb5c- b13d98251- c802b4717 http://w1.fi/hostap.git
ta-arm-eabi · mmc-utils · wpa_ supplicant

a5ffe45908- cae43925bb5c- b13d98251- c802b4717 http://w1.fi/hostap.git
a5ffe45908- cae43925bb5c- b13d98251- c802b4717 http://w1.fi/hostap.git
a5ffe45908- cae43925bb5c- b13d98251- c802b4717 http://w1.fi/hostap.git
a5ffe45908- cae43925bb5c- b13d98251- c802b4717 http://w1.fi/hostap.git
rscode 1.3 https://sourceforge.net/projects/rscode/files/rscode
xz 5.1.1 https://tukaani.org/xz
libsrp 2.1.2 https://github.com/secure-remote-password/stanford-srp/tree/master/ libsrp
libfdk-aac 0.1.4 https://github.com/mstorsjo/fdk-aac
libalac 4 https://github.com/macosforge/alac
mDNSRes- ponder 878.30.4 https://opensource.apple.com/source/mDNSResponder
nlohmann:: json 3.7.3 https://github.com/nlohmann/json
azure-iot-c- sdk 2019-10-07 https://github.com/Azure/azure-iot-sdk-c
angular 7.2.0 https://github.com/angular/angular.git
bcrypt 3.0.6 https://github.com/kelektiv/node.bcrypt.js
bcryptjs 2.4.3 https://github.com/dcodeIO/bcrypt.js
body-parser 1.18.3 https://github.com/expressjs/body-parser
bootstrap 4.3.1 https://getbootstrap.com/
bunyan 1.8.12 https://github.com/trentm/node-bunyan
bunyan- prettystream 0.1.3 https://github.com/trentm/node-bunyan
bunyan- syslog 0.3.3 https://github.com/trentm/node-bunyan
chromedriver 77.0.0 https://github.com/giggio/node-chromedriver
Core-js 2.5.4 https://github.com/zloirock/core-js
cors 2.8.5 https://github.com/expressjs/cors
dbus-native 0.4.0 https://github.com/sidorares/dbus-native
express 4.16.4 https://github.com/expressjs/express

generate- password 1.4.2 https://github.com/brendanashworth/generate-password
inversify 5.0.1 http://inversify.io
jquery 3.4.1 https://jquery.com/
js-yaml 3.12.0 https://github.com/nodeca/js-yaml
moment 2.27.0 http://momentjs.com/
morgan 1.9.1 https://github.com/expressjs/morgan
multer 1.4.1 https://github.com/expressjs/multer
ngx-cookie- service 2.2.0 https://github.com/7leads/ngx-cookie-service
npm 6.10.2 https://docs.npmjs.com
passport 0.4.0 http://github.com/jaredhanson/passport
passport-http 0.3.0 http://github.com/jaredhanson/passport-http
popper.js 1.15.0 https://popper.js.org
reflect- metadata 0.1.13 http://rbuckton.github.io/reflect-metadata
rxjs 6.3.3 https://github.com/ReactiveX/RxJS
swagger- parser 6.0.5 https://github.com/APIDevTools/swagger-parser
swagger-ui- express 4.0.1 https://github.com/scottie1984/swagger-ui-express
microsoft- graph-client 2.0.0 https://github.com/microsoftgraph/msgraph-sdk-javascript
isomorphic- fetch 2.2.1 https://github.com/matthew-andrews/isomorphic-fetch
promise 8.1.0 https://github.com/then/promise
request 2.88.2 https://github.com/request/request
tslib 1.9.0 http://typescriptlang.org
ws 7.1.1 https://github.com/websockets/ws
zone.js 0.8.26 https://github.com/angular/zone.js
f44ca27357563- e9ed43f1ff76d3- bd8dd14f4747e https://github.com/rockchip-linux/u-boot
805e544f539- b96d- e96388960173- bb673dab5a9dd https://github.com/rockchip-linux/kernel
https://android.googlesource.com/platform/external/avb/ +/21e95266704e572ced1c633bbc4aea9f42afa0a5/avbtool

b18c9afdb7- d02e1249cee5- cb430dc9f15a3- ccc27 https://github.com/rockchip-linux/avb/tree/master/boot_control
7617e69a524a- cc1a50a8a98- b257d1374ea6f- e4a4 https://github.com/rockchip-linux/avb/tree/master/libavb
7617e69a524a- cc1a50a8a98- b257d1374ea6f- e4a4 https://github.com/rockchip-linux/avb/tree/master/libavb_ab
7617e69a524a- cc1a50a8a98- b257d1374ea6f- e4a4 https://github.com/rockchip-linux/avb/tree/master/libavb_user
d6676eb02- c8a1b4966df7- d8c4bb203e- a25fc98b2 https://github.com/rockchip-linux/bin
1e3bdb582- c52707d71e5c- be29- ca1064d7c04- b696 https://github.com/rockchip-linux/rk_tee_user
04e55089bb4b- ba- de7c50d9b54- b5a1c- fa70771cd6 https://github.com/rockchip-linux/rkbin
59c3bdd06- a22844957fe20- f47c998bb8255- bedd2 https://github.com/rockchip-linux/gstreamer-rockchip
862b0d89363- e18e45e5db5c- c6c316a173- c5ac2e7 https://github.com/rockchip-linux/mpp
f226- e982386287a4- df669e2832d9d- dd613d4153b https://github.com/rockchip-linux/libmali
72e7764a9f- e358e6a- d50eb1b21176- cc95802c7fb https://github.com/rockchip-linux/linux-rga
https://www.nxp.com/support/developer-resources/software- development-tools/mcuxpresso-software-and-tools/mcuxpresso- software-development-kit-sdk:MCUXpresso-SDK?tab=Design_Tools_ Tab
unlz4 - https://github.com/lz4/lz4/blob/dev/lib/lz4.h

ring-buff - https://code.google.com/archive/p/ring-buff
wpa_ supplicant 2.6 http://w1.fi/wpa_supplicant
You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
You may also find helpful the following booklet, prepared by the FCC: "How to Identify and Resolve Radio-TV Interference Problems." This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commissions rules.
In order to maintain compliance with FCC regulations shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio & television reception.
FCC RF Radiation Exposure Statement: This device is capable of operating in 802.11a mode. For 802.11a devices operating in the frequency range of 5.15 - 5.25 GHz, they are restricted for indoor operations to reduce any potential harmful interference for Mobile Satellite Services (MSS) in the US. WIFI Access Points that are capable of allowing your device to operate in 802.11a mode (5 .15 - 5.25 GHz band) are optimized for indoor use only. If your WIFI network is capable of operating in this mode, please restrict your WIFI use indoors to not violate federal regulations to protect Mobile Satellite Services.
ClickShare Button 2AAED-R9861600D01 has been tested and meets the FCC RF exposure guidelines.The maximum SAR value reported is 1.19 W/kg.
ClickShare Button 2AAED-R9861600D01 should be installed and operated with a minimum distance of 5 mm between the radiator and your body.
FCC responsible: Barco Inc., 3059 Premiere Parkway Suite 400, 30097 Duluth GA, United States, Tel: +1 678 475 8000
For coutry code selection usage (WLAN devices) :

This device complies with Industry Canada licence-exempt RSS standard (s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
The radiated output power of the Barco Wireless Device is below the Industry Canada (IC) radio frequency exposure limits. The Barco Wireless Device should be used in such a manner such that the potential for human contact during normal operation is minimized.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This radio transmitter 23575-R9861511 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.
This device is also designed to meet the requirements for exposure to radio waves established by the Industry Canada.
The SAR limit adopted by Canada is 1.6 W/kg averaged over one gram of tissue. The highest SAR value reported to the IC for this device type complies with this limit.
The highest SAR value reported to the IC for this device type when using in portable exposure conditions is 1.15 W/kg.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
La puissance de sortie émise par l'appareil de sans fil Barco est inférieure à la limite d'exposition aux fréquences radio d'Industry Canada (IC). Utilisez l'appareil de sans fil Barco de façon à minimiser les contacts humains lors du fonctionnement normal.


6 C-10, C-5 Configurator 61 6.1 Accessing the Configurator 63 6.2 ClickShare Configuration Wizard 66 6.3 On-Screen ID information 69 6.4 Personalisation, Wallpaper 71 6.5 Personalisation, Personalized wallpaper 72 6.6 Manage configuration files 74 6.7 Display & Audio setup 75 6.8 Peripherals 76 6.9 Wi-Fi settings 76 6.10 Wi-Fi settings, Access Point settings 77 6.11 Wi-Fi settings, Wireless Client 79 6.12 Wi-Fi settings, Wireless Client, EAP-TLS 80 6.13 Wi-Fi settings, Wireless Client, EAP-TTLS 82 6.14 Wi-Fi settings, Wireless Client, PEAP 83 6.15 Wi-Fi settings, Wireless Client, WPA2-PSK 84 6.16 LAN settings 85 6.17 Services, Mobile devices 87 6.18 Service, ClickShare API, remote control via API 89 6.19 Services, SNMP 89 6.20 Security, security level 90 6.21 Security, passwords 92 6.22 Status information Base Unit 92 6.23 Date & Time setup, manually 93 6.24 Date & Time setup, time server 95 6.25 Energy savers 95 6.26 Buttons 96 6.27 Buttons, External access point, mode EAP-TLS 97 6.28 Buttons, External access point, mode EAP-TTLS 99 6.29 Buttons, External access point, mode PEAP 100 6.30 Buttons, External access point, mode WPA2-PSK 101 6.31 Blackboard 101 6.32 XMS Cloud Integration 102 6.33 Firmware Update 103 6.34 Support & Updates, Troubleshoot, log settings 104 6.35 Troubleshooting, Erase all settings 105 6.36 Reset to factory defaults 106
7 Firmware updates 109 7.1 Updating the C-10, C-5 firmware 110
8 Troubleshooting 111 8.1 Troubleshooting list 112
Index 115

1.1 Documentation 26 1.2 Symbols and fonts 26

Introduction to the Installation Guide
This installation guide explains how to install your C-10, C-5 in a meeting room, It explains also how to make everything operational. It provides detailed information on how to configure your C-10, C-5.
Next to the installation manual, a user guide and a safety guide are available on Barco’s website, www.barco.com/clickshare.
A printed copy of the Safety Guide is included in the C-10, C-5 box at purchase.
Depending on the C-10, C-5 version, some graphics might be different to the ones used in this manual. This however does not have any effect on the functionality.
The following icons are used in the manual :
Info, term definition. General info about the term


This ClickShare device is a wireless presentation system and your ticket to a collaborative meeting.
This device not only helps the presenter get the presentation on-screen in a second. The result is enhanced meeting efficiency and better decision-making.
The set is compatible with any laptop, desktop tablet or smartphone OS.
At the moment 6 different sets are available on the market. Each set is sold in its specific region and it can only be used in that specific region because of WiFi regulations.
For C-10:
A standard C-10 set consists of a Base Unit and one Button. Depending on the location where you buy the product, the software of the Base Unit is different.

Image 2–1
1 Base Unit 2 Button
For C-5:
A standard C-5 set consists of only a Base Unit. Depending on the location where you buy the product, the software of the Base Unit is different.

Image 2–2
Depending on the country where you buy the product, the following regionalized accessories are also included in the box.
C-10, C-5 Specifications

R9861600D01C3, 5 1 x R9861600D1C3,5
Contact your local sales representative for the correct regional variant to be used in your country.
Dimensions (HxWxD) 34 mm x 135 mm x 135 mm
Power supply Standard 110/220 V AC plug
Operating system Windows 8/8.1/10. macOS 10.13 and higher. Android v9 and higher (ClickShare App)* iOS 12 and higher (ClickShare App)*
Video outputs 4K UHD (3840*2160) @ 30Hz. HDMI 1.4b
ClickShare App Desktop & Mobile
Native protocols Airplay, Google Cast, Miracast*
Noise Level Max. 25dBA @ 0-30°C Max. 30dBA @ 30-40°C
Authentication protocol WPA2-PSK in stand alone mode WPA2-PSK or IEEE 802.1X using the ClickShare Button in network integration mode
IEEE 802.11 a/g/n/ac and IEEE 802.15.1
Reach Adjustable with signal strength modulation; max. 30m (100 ft) between ClickShare Button and ClickShare Base Unit Frequency band 2.4 GHZ and 5 GHz


Frequency band 2.4 GHZ and 5 GHz (DFS channels supported in select number of countries)
Connections 1x Ethernet LAN 1Gbit 1x USB Type-C 2.0 (front); 1x USB Type A 2.0 (front)
Temperature range Operating: 0°C to +40°C (+32°F to +104°F) Max: 35°C (95°F) at 3000m Storage: -20°C to +60°C (-4°F to +140°F)
Warranty 1 year standard. 5 years coverage via SmartCare
* * depends on configuration, available in future firmware updates

Dimensions (HxWxD) 34 mm x 135 mm x 135 mm
Operating system Windows 8/8.1/10. macOS 10.13 and higher. Android v9 and higher (ClickShare App)* iOS 12 and higher (ClickShare App)*
Video outputs 4K UHD (3840*2160) @ 30Hz. HDMI 1.4b
Noise Level Max. 25dBA @ 0-30°C Max. 30dBA @ 30-40°C
Authentication protocol WPA2-PSK in stand alone mode WPA2-PSK or IEEE 802.1X using the ClickShare Button in network integration mode
C-10, C-5 Specifications

IEEE 802.11 a/g/n/ac and IEEE 802.15.1
Reach Adjustable with signal strength modulation; max. 30m (100 ft) between ClickShare Button and ClickShare Base Unit Frequency band 2.4 GHZ and 5 GHz
Frequency band 2.4 GHZ and 5 GHz (DFS channels supported in select number of countries)
Connections 1x Ethernet LAN 1Gbit 1x USB Type-C 2.0 (front); 1x USB Type A 2.0 (front)
Temperature range Operating: 0°C to +40°C (+32°F to +104°F) Max: 35°C (95°F) at 3000m Storage: -20°C to +60°C (-4°F to +140°F)
Anti-theft system Kensington lock
Touch screen support & Interactivity
Room Dock (peripheral support)
Local view & moderation Local view of the room display only
Network connection LAN & WiFi
Management and reporting Yes
Warranty 1 year standard. 5 years coverage via SmartCare
* * depends on configuration, available in future firmware updates
Weight 60 gr - 0.132 lb
Frequency band 2.4 GHZ and 5 GHz
IEEE 802.11 a/b/g/n/ac
Authentication protocol WPA2-PSK in stand alone mode WPA2-PSK or IEEE 802.1X in network integration mode
Dimensions (HxWxD) 14.6 mm x 59.3 mm x 161.39 mm / 0.57” x 2.354” x 6.354”
Power consumption Powered over USB 5V DC 350mA Typical 500mA Maximum

The Base Unit receives the wireless input and controls the content of the meeting room display.
The Base Unit can be put on the meeting room table or mounted on a wall or ceiling. Check the installation guide for instructions on how to install the Base Unit.

Image 2–3
1 USB Type-A port (USB 2.0)
2 USB Type-C port (USB 2.0)
3 Status LED ring
5 Hardware reset button
The USB Type-CTM is used to pair the (optional) available Buttons. The USB Type-CTM and USB Type-A can be used to update the Base Unit firmware when not done via XMS.
When plugging in the (optional) Button into the Base Unit, the Button is paired to the Base Unit. The Base Unit checks whether the software and firmware of the Button is up to date. If not, the Base Unit updates the software and/or firmware.
The use of a convertor is sometimes necessary to connect to one of these ports.
The color of the LED ring around the power button of the Base Unit give information on the status of the system.
breathing white • ECO standby mode
C-10, C-5 Specifications · 4 Standby button · LEDs behavior Explanation

red blinking • an error occurred
dark • deep standby/off
The connection panel is situated at the back of the Base Unit.

Image 2–4
3 LAN Ethernet connection 4 Kensington lock
The mechanical fixture points are located at the bottom of the Base Unit.
The antenna is built-in in the C-10, C-5.
The serial number label containing the Barco part number, the revision number, production date (week-year) and the serial number.
The product label with the applicable certification logos.
The product label contains:
The below list of Apps are supported by ClickShare and can be installed on your mobile device from Google Play or Apple App Store. Or can be installed on your Windows or Mac pc

Before you can use your mobile device with ClickShare, you have to connect the mobile device Wi-Fi with the ClickShare Base Unit Wi-Fi. Follow the instructions as given in your mobile device user guide. Or connect the Base Unit to the network, then you do not need to switch your Wi-Fi.
ClickShare App iOS Android Windows Mac OS
Apps can be downloaded from www.clickshare.app.
C-10, C-5 Specifications · App Used on

3.1 Environmental Condition Check 36 3.2 Basic Workflow 36

For installations in environments where the device is subject to excessive dust, then it is highly advisable and desirable to have this dust removed prior to it reaching the device clean air supply. Devices or structures to extract or shield excessive dust well away from the device are a prerequisite; if this is not a feasible solution then measures to relocate the device to a clean air environment should be considered.
It is the customer's responsibility to ensure at all times that the device is protected from the harmful effects of hostile airborne particles in the environment of the device. The manufacturer reserves the right to refuse repair if a device has been subject to negligence, abandon or improper use.
Do not install the device in a site near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive dust or humidity. Be aware that room heat rises to the ceiling; check that temperature near the installation site is not excessive.
For a detailed overview of the content of the C-10, C-5 box, see “C-10, C-5 Specifications”, page 29
For more information on the installing procedures,see “Installation methods for the Base Unit”, page 38
For more information, see “Power connection”, page 44,
Getting started

4.1 Installation methods for the Base Unit 38 4.2 Table mounting 38 4.3 Wall or ceiling mounting 38 4.4 Out-of-the-box use of the Base Unit 40 4.5 Network connected setup 41 4.6 Dedicated network setup 41 4.7 Video signal connections to the Base Unit 42 4.8 Touch screen connections to the Base Unit 43 4.9 LAN connection 43 4.10 Power connection 44 4.11 Starting up for the first time 44 4.12 First setup of the Base Unit 45 4.13 Registration to XMS Cloud 46 4.14 Use without registration of the device 48 4.15 Basic configuration of the ClickShare device 51

For optimal performance, install the Base Unit close to the display and avoid obstacles between the Base Unit and the Buttons.
Make sure not to install the Base Unit in a metal enclosure.
The Base Unit can be installed in different ways in a meeting room.
The Base Unit can be use as standalone unit or integrated in a corporate network.
Put the Base Unit directly on the meeting room table.
The total weight of the Base Unit is 530 g.
A mounting base is used to mount the C-10, C-5t o the wall or ceiling. This base has key-shaped screw holes to allow you to fasten the base to a wall or ceiling or you can use the self-adhesive layer to mount the base. Once you determine the location for your device follow the next procedure to mount the device.
C-10, C-5 Installation


Image 4–1


Image 4–2
C-10, C-5 Installation


Image 4–3
This setup is the simplest in terms of installation and can be used for temporary setups and in organizations where central management and 3rd party integration are not required.
The ClickShare Base Unit and (optional) Button operate directly out of the box, without any integration in the Enterprise network. The Base Unit should be connected to the internet at least once to update and to register. Users can connect directly to the Base Unit via the ClickShare Button, using the ClickShare App or Miracast or with their mobile devices using Airplay or Google Cast.
Using a ClickShare Button allows you to stay connected to the internet. Using the ClickShare App, Airplay or Google Cast will require connecting to the Base Unit directly and will only be able to access the internet if the device supports to use data (3G/4G) at the same time. Note that this requires the Base Unit’s access point is not turned off, is visible and can be connected to by anyone.
Sharing via Miracast will only be possible via Wi-Fi direct.


Image 4–4
Image 4–5
Using the ClickShare Base Unit and Button directly out of the box is ideal for temporary setups, visitor centers and small to medium installations without network integration needs or possibilities. This setup requires the least installation effort and keeps any shared data completely separated from your Enterprise network. Updating and configuring the Base Units will need to be done manually.
C-10, C-5 Installation

This is the simplest installation which offers a seamless experience for employees and is the recommended setup for temporary setups, visitors' centers, small to medium installations without network integration needs, for internal meeting rooms, for companies with a flat network topology or when the ClickShare Button will be the main way for people to the system.
In this default mode, (optional) ClickShare Button and Base Unit operate directly out of the box (Button must be paired to the Base Unit before it can be used) and users can share to the Base Unit with the ClickShare Desktop App, the ClickShare Mobile App, AirPlay, Google Cast via the network to which the Base Unit is connected without losing the internet connectivity. Sharing via Miracast depends on the configuration of the device.
Using a ClickShare Button allows guests to stay connected to the Guest LAN and thus retain internet connectivity. Guest mobile devices will usually need to connect to the Base Unit directly and will only be able to access the internet if the device supports to use data (3G/4G) at the same time.


Image 4–6
Image 4–7
This installation offers an isolated network setup where all connections from and to the Base Units can be controlled. This dedicated AV (or ClickShare) network or VLAN can be used for more fine-grained access control, to ensure no connection can happen between any of the connected physical or virtual LANs or to separate all ClickShare traffic from all other IP traffic to ensure business requirements in terms of bandwidth, security and latency.
In this setup, the configurations can widely differ depending on network topology and security requirements in the organization. Here, we will describe a simple setup where the Base Unit is placed in a dedicated AV VLAN, a commonly used practice within organizations.
In this setup, ClickShare Buttons and Base Unit operate directly out of the box (Buttons must be paired to the Base Unit before they can be used)). Since the Base Unit has been installed in a dedicated network, firewall configuration will be required to enable the use of the ClickShare Desktop App, the ClickShare Mobile App, AirPlay and Google Cast over the network
If the firewall is not configured to allow connections from either the guest Wi-Fi or the employee Wi-Fi, users can connect to the wireless access point of the Base Unit to share with the ClickShare Desktop App, ClickShare Mobile App, AirPlay and Chromecast and will only be able to access the internet if the device supports to use data (3G/4G/5G) at the same time. Note that this requires that the Base Unit’s access point is not turned off, is visible and can be connected to by anyone. Mobile users are limited to the experience described in the standalone setup. For Miracast, the Base Unit will have to be configured for Miracast to offer a Wi-Fi direct connection.
C-10, C-5 Installation

Connecting the Base Unit to the Enterprise network opens the possibility for using the eXperience Management Suite (XMS) for central management and/or using the auto-update functionality to keep your installed base up to date.
A Base Unit which is connected to the network, can be monitored through SNMP, can be controlled and monitored by other 3rd party systems such as Overture or Crestron or can be interfaced through the ClickShare REST API.


Image 4–8
Image 4–9
Select External Access Point from the drop down menu and select the preferred authentication mode and fill out the details.
Click Save Changes. For more information, see “Buttons”, page 96
For more detailed information on how to use XMS, consult the XMS user guide.
A single screen can be connected to the Base Unit.
To connect a display, an HDMI connection should be made between the Base Unit and the display.
C-10, C-5 Installation

When setting up a display configuration, connect the HDMI cable to the display. When necessary, use an adapter piece to connect to a display port or a DVI port on the display side.
Image 4–10 Display connection
Only available on C-10.
A single screen can be connected to the Base Unit.
To connect video, an HDMI connection should be made between the Base Unit and the display. To connect the touch functionality, an USB cable should be connected between the touch screen and the Base Unit. A list of supported touch screen can be found on Barco’s website. See https://www.barco.com/en/support/docs/TDE9538.
The Base Unit can be connected to a local network or directly to a laptop.
We do strongly advise the LAN connection and the use of XMS cloud for configuration, monitoring and additional functionality. The LAN connection also greatly improves the user experience when using the ClickShare Apps and native sharing protocols such as Airplay and others.
C-10, C-5 Installation

An external power adapter is delivered with the product. The output rate is 12 VDC 2A.
which is applicable in your country.

Image 4–11 Power adapter
The following steps are necessary before the Base Unit can be used:
C-10, C-5 Installation

After the physical installation is done, start with the first setup procedure to activate and configure your device.
The following screen can be seen on the Base Unit’s main output when it is not connected to any network.

Image 4–12
This screen can show up when either no network cable is connected to the Base Unit, when additional configuration is required or when network requirements for the first time setup of the Base Unit have not been met.
The system checks for updates.

Image 4–13
If an update is available, the base unit will download, update and reboot
if no update is available, the unit will continue to the next step
C-10, C-5 Installation

When your device is connected to the internet and updated you can start to register your device. You have to register your device in order to claim your 5 years SmartCare warranty.
Registration can be done to

Image 4–14
The XMS login page is displayed.

Image 4–15 Sign in page
The XMS cloud welcome page is displayed.
C-10, C-5 Installation


Image 4–16 Welcome page to XMS-cloud

Image 4–17 Company information
Click Continue.

Image 4–18 Enter device token
C-10, C-5 Installation


Image 4–19 Assign meeting room
Your device is successfully registered.

Image 4–20 Start pairing buttons
The wallpaper page will be displayed.
Several reasons are possible to use your product without registration:
then you can skip the registration
The end-customer, then has 6 months to still register the unit in XMS cloud to activate the Smart Care package
C-10, C-5 Installation

The default SSID is ClickShare-.
Browse to http://192.168.2.1
The ClickShare Configurator starts up.

Image 4–21 Configurator startup

Image 4–22 Configurator, language selection
A registration message is displayed.
C-10, C-5 Installation


Image 4–23 Registration message

Image 4–24 Start pairing
Your still have to register your device to get your 5 years warranty.
When browsing in the Configurator to System →XMS, you will see a XMS Cloud integration message how to register it and the token to use.
C-10, C-5 Installation


Image 4–25 XMS cloud message
Make sure you are connected via WiFi to the Base Unit.
The ClickShare Configurator starts up.
Image 4–26 Configurator startup
C-10, C-5 Installation

Image 4–27 Configurator, language selection
A registration message is displayed.
The Configurator Login page is displayed.

Image 4–28 Configurator, login page
C-10, C-5 Installation

A welcome page to the ClickShare Configuration Wizard opens.
Follow the instructions as given on the different pages.
Click Next to continue to the next page and Back to return to the previous page.
Security select your desired security level
Password Enter a new password to login to the ClickShare Configurator.
Network Setup the network settings:
For more detailed information about all these settings,
Your Base Unit can now communicate via LAN.
Start pairing the buttons.
C-10, C-5 Installation · Personali- sation

C-10, C-5 Installation

5.1 Pairing 56 5.2 ClickShare Extension Pack 57 5.3 ClickShare Extension Pack installer 57 5.4 ClickShare Windows Certified driver 58 5.5 ClickShare Desktop app 58

To be able to use a Button it should be assigned to the Base Unit you are using. This process is called pairing. All Buttons will need to be updated and paired before use.
In case you buy additional Buttons or when a Button should be assigned to another Base Unit, the Button needs to be paired (again). The Button software update runs in the background and will not impact users while using the system. When downgrading or updating to an older version of the Base Unit software the Button need to paired manually to update their software.
A Button can only be paired to one Base Unit at a time. The Button will always make connection to the Base Unit it was last paired to.
Pairing a Button can be done in two ways:

Image 5–1 Pair Button
The Base Unit LED is blinking while the Button LED fills up a circle. This means pairing is in progress.
The Base Unit automatically checks whether the software of the Button is up to date. If not, the Base Unit updates the Button software. This may take more time. The result of the pairing process can be as follows:
The Button is now ready for use.

Image 5–2
Preparing the Buttons

The ClickShare Extension Pack is a collection of tools to upgrade your ClickShare user experience. This Extension Pack contains the ClickShare Launcher service and a driver to enable the Extended Desktop functionality (only on Windows). Both tools will be installed by default. To change the default behavior of the installer, the installer will need to be executed with command line parameters.
The ClickShare Extension Pack can be installed by the end user manually, pre-installed on your company’s laptop image or deployed company-wide with SCCM or other tools.
The ClickShare Extension Pack can be used in combination with a Button and/or with the ClickShare desktop app.
The latest extension pack can be downloaded via http://www.barco.com/en/product/clickshare-extension-pack
In this setup, the user runs the installer which will install the ClickShare Extension Pack on his computer after the user accepts the EULA.
After the setup finished, the ClickShare launcher will be started automatically. The Extended desktop driver can only be used after the user reboots his computer.

Image 5–3
If necessary, follow the on screen instructions.
In this setup, a user or an IT admin can install the ClickShare Extension pack using the Windows command prompt. Following is an example of a silent installation (version numbers are only given as example, always check Barco’s web for the latest version):
Launcher only install:
Preparing the Buttons

msiexec. exe /i ClickShare-Extension-Pack-01.00.02.0003. msi ACCEPT_EULA=YES INSTALLFOLDER=C:\ LAUNCH_APP=YES /qn
Extended desktop only install :
msiexec. exe /i ClickShare-Extension-Pack-01.00.02.0003. msi ACCEPT_EULA=YES ADDLOCAL=ExtendedDesktopDriverFeature INSTALLFOLDER=C:\ LAUNCH_APP=YES /qn
Full install (laucher + extended desktop):
msiexec. exe /i ClickShare-Extension-Pack-01.00.02.0003. msi ACCEPT_EULA=YES ADDLOCAL=ALL INSTALLFOLDER=C:\ LAUNCH_APP=YES /qn
The computer will reboot. This can be suppressed with /norestart. A reboot will be needed afterwards for the extended desktop feature to be working. In case the end-user should decide if they want to reboot, /promptrestart /QB!+ can be used (basic UI, no cancel option, but prompt to reboot)
ACCEPT_EULA This parameter shows that the installer accepts the EULA text as is. This parameters must be set to YES in order to continue to the installation.
This parameter specifies the installation directory for ClickShare launcher. If not specified, the default folder will be the Program Files folder.
LAUNCH_APP The ClickShare launcher application will be started right after the installation finishes if this parameter is set to YES. Otherwise, the launcher application will not be started.
/qn This parameter indicates that the installation will be done in silent mode, meaning that there will be no visible windows during the installation.
ADDLOCAL This parameter indicated the type of the installation. No parameter added, installs only the launcher.
The variable to be used is CLICKSHARE_LAUNCHER_CLIENT_PATH. The value should be the path to the client software.
The ClickShare Windows Certified driver is auto-installed when plugging in a Button in a Window PC.
This Windows driver automatically lauches the executable on the Button.
With the ClickShare desktop app installed on your computer you can enter a meeting room and get on the screen in a few seconds without the need to plug in a Button. The ClickShare app can be used in combination with a Button.
The ClickShare desktop app connects to the meeting room screen in order to share your content. Presence detection technology is used to do so. The ClickShare desktop app uses presence detection technics to determine which meeting room is closest to the user. Just click on your meeting room name. This means you will never have to enter IP addresses or scroll long lists of meeting rooms before being connected to your meeting room.
When using Outlook as your main agenda, you get also an immediate overview of your next meetings. No need to search for the appointment or invite in Outlook. Just click Join to join your conference call.
Preparing the Buttons · Parameter Description · Windows environment variable

When the ClickShare desktop app is not pre-deployed in your IT environment, you can download and install the software without administrator rights from www.clickshare.app.
Preparing the Buttons

Preparing the Buttons

6.1 Accessing the Configurator 63 6.2 ClickShare Configuration Wizard 66 6.3 On-Screen ID information 69 6.4 Personalisation, Wallpaper 71 6.5 Personalisation, Personalized wallpaper 72 6.6 Manage configuration files 74 6.7 Display & Audio setup 75 6.8 Peripherals 76 6.9 Wi-Fi settings 76 6.10 Wi-Fi settings, Access Point settings 77 6.11 Wi-Fi settings, Wireless Client 79 6.12 Wi-Fi settings, Wireless Client, EAP-TLS 80 6.13 Wi-Fi settings, Wireless Client, EAP-TTLS 82 6.14 Wi-Fi settings, Wireless Client, PEAP 83 6.15 Wi-Fi settings, Wireless Client, WPA2-PSK 84 6.16 LAN settings 85 6.17 Services, Mobile devices 87 6.18 Service, ClickShare API, remote control via API 89 6.19 Services, SNMP 89 6.20 Security, security level 90 6.21 Security, passwords 92 6.22 Status information Base Unit 92 6.23 Date & Time setup, manually 93 6.24 Date & Time setup, time server 95 6.25 Energy savers 95 6.26 Buttons 96 6.27 Buttons, External access point, mode EAP-TLS 97 6.28 Buttons, External access point, mode EAP-TTLS 99 6.29 Buttons, External access point, mode PEAP 100 6.30 Buttons, External access point, mode WPA2-PSK 101 6.31 Blackboard 101 6.32 XMS Cloud Integration 102 6.33 Firmware Update 103 6.34 Support & Updates, Troubleshoot, log settings 104 6.35 Troubleshooting, Erase all settings 105 6.36 Reset to factory defaults 106

The configuration of your device can be done in
The configurator in XMS cloud will (in time) more elaborated than the local configurator. Therefore it preferred to configure your devices via XMS cloud. For more info see XMS documentation.
The next topics are describing the local configurator.
Within some menus the Configurator is indicated as WebUI. E.g. WebUI password, that is the password to enter the Configurator.

There are three ways to access the Configurator:
When accessing the configurator for the first time, the ClickShare Configuration Wizard starts automatically.
This configuration wizard can be started at any moment to change your configuration instead of using the menus.
A login screen appears.
Image 6–1 Login screen


Image 6–2 Configurator lanuguages
The following languages are possible:
The Configurator language changes to the selected language.
By default, the password is set to 'admin'.
The Configurator opens.


Image 6–3 Start screen
The language of the configurator can be changed on any page in the interface.
The screen is split up in 2 panes. Left pane with the selection buttons and a right pane to configure the selected function.
Each of these boxes are also direct links to the described function.
If you cannot find the IP address (e.g. there is no screen available) you should connect to the Base Unit directly with your laptop via an Ethernet crossover cable and access the web interface using the fixed IP address 192.168.1.23. Make sure your own LAN adapter is set in the 192.168.1.x range.
To access the Configurator via a direct connection.
A login screen appears.
By default the password is set to 'admin'.
The configurator opens. The wired IP address is given on the startup page.

The default SSID and password to connect to the Base Unit are respectively 'ClickShare-' and 'clickshare'.
A login screen appears.
By default the password is set to 'admin'.
The configurator opens. The wired IP address is given on the startup page.
Older laptops might not support the 5 GHz Frequency Band. If your Base Unit is set to that frequency range, those devices will not be able to connect to the Base Unit via the wireless network.
Personalization On-Screen ID Wallpaper
Display & Audio Display & Audio
Wi-Fi & Network Wi-Fi Settings
Passwords System Base Unit Status
XMS Support & Updates Firmware
During the first start up of the Base Unit, the configuration wizard starts up automatically.
All basic settings necessary to configure the Base Unit are covered by the configuration wizard. Once the configuration wizard is finished, the Base Unit is ready to be used.


Image 6–4 Configuration wizard
To start the wizard, click on Start Configuration.


Image 6–5 Configuration wizard, Personalisation
Fill out the necessary field and click Next to continue.
To return to the previous step, click on Back.
For more information about a specific topic, see one of the following topics.
The ClickShare Configuration Wizard can be started at any time to change the configuration just by clicking on ClickShare Configuration Wizard at the left bottom of each screen.
Language on-screen text See “On-Screen ID information”, page 69.
Meeting room name, location name and welcome message
See “On-Screen ID information”, page 69.
System Time zone, manual time setup See “Date & Time setup, manually”, page 93.
Use NTP See “Date & Time setup, time server”, page 95. Security Level settings See “Security, security level”, page 90.
Password ClickShare Configurator (WebUI) password See “Security, passwords”, page 92.
Network Frequency band, channel Wi-Fi passphrase See “Wi-Fi settings, Wireless Client”, page 79.
Personalisa- tion


Image 6–6 Configuration Wizard start
The following items can be set:


Image 6–7 On-Screen ID
The following languages are possible:
This text is shown on the user's device when the Button is ready to share ("Ready to share on..."), on the central screen connected to the Base Unit and in the list of AirPlay receivers on the user's iOS device.

When C-10, C-5 starts up, a background (wallpaper) is displayed. The display of this background wallpaper can be disabled.
By default two general ClickShare wallpapers are available. The possibility exists to upload personal backgrounds (wallpapers). The default wallpapers cannot be removed from the system.

Image 6–8 Wallpaper selection
The Wallpaper selection pane is shown. The current selected wallpaper is shown with a red border.
The selected wallpaper is indicated with a red border.
The message Successfully applied changes appears on top of the wallpaper selection window.
You can also add a personal wallpaper, e.g. your company logo. For more information on adding a new wallpaper to the list, see “Personalisation, Personalized wallpaper”, page 72.


Image 6–9 Download wallpaper
The wallpaper is downloaded to your PC.
Checked: wallpaper will be displayed when no one is sharing content.
Not checked: no wallpaper will be displayed when no one is sharing content. The video output of the Base Unit is disabled when no content is shared. This feature is especially useful when the Base Unit is integrated in a room system such as a Cisco video conferencing system, Microsoft Teams room system or a Zoom room system.
The Wallpaper selection pane is shown. The current selected wallpaper is shown with a red border.

Image 6–10 Personalized wallpaper selection
A browser window opens.

The content of the file is checked and when valid (format and size), the file is uploaded. The new wallpaper gets a red border.
The message Successfully applied changes is displayed on top of the page.

Image 6–11 Change image
The content of the file is checked and when valid (format and size), the file is uploaded. The new wallpaper gets a red border.
The message Successfully applied changes is displayed on top of the page.

Image 6–12 Remove wallpaper
The personalized wallpaper is removed and the default wall paper is activated.

A full backup can be downloaded but cannot be used to duplicate configuration settings to other Base Units. Therefore, it is possible to download a Portable version. This portable version can be uploaded via the upload configuration button on other Base Units (same type). Via the same button, the full backup can be uploaded on the original Base Unit.
A portable backup contains:

Image 6–13 Configuration files
An xml file, containing all information and history will be downloaded. This file can be reused on the same Base Unit only.
An xml file, containing portable information to duplicate settings on another Base Unit.
A browser window opens. Navigate to the upload file (xml file) and click Open to upload.
A full backup can be uploaded on the Base Unit where the backup was created and a portable version can be uploaded on any other Base Unit of the same model.

When uploading a config file, the history of software updates and paired Buttons is lost. Paired Buttons will however remain functional if the Base Unit has not changed from SSID or wireless password.
The output resolution to the display is set on Auto. That means that the C-10, C-5 output resolution is automatically adapted to the resolution of the display. For HDMI displays, a hot plug detection is available.
Consumer Electronics Control (CEC) is a feature of HDMI designed to allow users to command and control devices connected through HDMI by using only one remote control.
To enable CEC, check the check box before Enable CEC.
Enable or disable audio output.
Check the check box in front of Enable audio to enable audio output.

Image 6–14
When the slider is set completely to the left, the screen saver will never be activated.

Information about the speaker is given in the Peripherals pane.
Information about the speaker is given.

Image 6–15
The operational mode of the Wi-Fi setting can be set in 3 different modes:


Image 6–16 Wi-Fi settings
The following options are possible.
For more detailed information, see “Wi-Fi settings, Access Point settings”, page 77
For more detailed information, see “Wi-Fi settings, Wireless Client”, page 79.
Checked: access point settings are enabled. All current settings can be changed.
Unchecked: access point settings are disabled.


Image 6–17 Wi-Fi settings, access point settings
The default SSID is ClickShare-<serial number Base Unit>.
In an ideal setup, overlapping channels should not be used for two ClickShare Base Units within range of each other. As the channels in the 2.4 GHz band overlap with each other, best practice is to use channels 1, 6 and 11 on a single floor. On floors above and below, the channel pattern will be shifted to avoid overlap between floors, e.g. by placing channel 6 at the center of the illustrated pattern.
Image 6–18

The 5 GHz channels do not overlap with each other and are less used by non-Wi-Fi devices than the 2.4 GHz channels. Moreover, 5 GHz signals are more rapidly damped than 2.4 GHz signals. Therefore, the use of a 5 GHz channel is recommended. This will limit the impact of a ClickShare system on other installed ClickShare units and on other WLAN users.
The channels available in the list vary according to the regional version of your Base Unit. Re-pairing the Buttons is not required when changing the frequency band or wireless connection channel.
Ideally, the ClickShare channel is selected after conducting a wireless site survey. A site survey maps out the sources of interference and the active RF systems. There are several Wi-Fi survey tools available on the market. Based on the results from a site survey, the least occupied channel can be found and selected for each meeting room.
Below the channel selection pane, an indication is given of the available bandwidth of the current channel. To see if sufficient bandwidth is available in a different channel, select the channel in the drop down and save the changes. The page will reload with the new settings and an indication of the channel fit will be given after approximately 1 minute. There is no need to reload the page to see the result.
The channels available in the list vary according to the regional version of your Base Unit. Re-pairing the Buttons is not required when changing the frequency band or wireless connection channel.
When Intense use, change to another Wi-Fi channel is displayed, change to another channel. The page will reload after approximately 1 minute.
Checked: Configurator accessible via Wi-Fi.
Not checked: access to the configurator via Wi-Fi is blocked.
For more info, see “Wi-Fi settings, Wireless Client”, page 79.
Wireless Client mode allows to connect the Base Unit to a network over Wi-Fi instead of via the Ethernet interface. It brings identical functionality as a wired network connection; complete network integration, auto- update functionality and central management in XMS. It offers increased flexibility in the placement of the Base Unit as a network cable drop is no longer required on the installation location.
Note that when Wireless Client mode is enabled, the Base Unit Wi-Fi is occupied and can no longer be used for direct connections, either from the ClickShare Button, the ClickShare apps or from Airplay or Google Cast and Miracast. This means that these connections need to happen over the corporate network. As a consequence, when setting up Wireless Client mode, the Buttons are auto-configured to connect to the same network as the Base Unit. This setting however can be manually changed in the Buttons tab in the System menu.

For Wireless Conferencing, a direct connection between the Button and the Base Unit is advised.

Image 6–19 Wi-Fi settings, Wireless Client
EAP-TLS (Transport Layer Security) is an EAP method based on certificates which allows mutual authentication between client and server. It requires a PKI (Public Key Infrastructure) to distribute server and client certificates. For some organizations this might be too big of a hurdle, for those cases EAP-TTLS and PEAP provide good alternatives. Even though a X.509 client certificate is not strictly required by the standard it is mandatory in most implementations including for ClickShare. When implemented using client certificates, EAP-TLS is considered one of the most secure EAP methods. The only minor disadvantage, compared to PEAP and EAP-TTLS, is that the user identity is transmitted in the clear before the actual TLS handshake is performed. EAP-TLS is supported via SCEP or manual certificate upload.


Image 6–20 Wi-Fi Settings, Wireless Client, EAP-TLS
The SSID of your corporate wireless infrastructure to which the ClickShare Buttons will connect.
Allowed file formats:
The should at least include the client certificate and corresponding private key.
The following formats are allowed:

File should at least contain the root CA certificate for your domain.
The Simple Certificate Enrolment Protocol (SCEP) is a protocol which enables issuing and revoking of certificates in a scalable way. SCEP support is included to allow a quicker and smoother integration of the ClickShare Base Unit and Buttons into the corporate network. Since most companies are using Microsoft Windows Server and its active directory (AD) to manage users and devices our SCEP implementation is specifically targeted at the Network Device Enrolment Service (NDES) which is part of Windows Server 2008 R2 and Windows Server 2012. No other SCEP server implementations are supported.

Image 6–21 Wi-Fi Settings, Wireless Client, EAP-TLS, SCEP
This is the IP or hostname of the Windows Server in your network running the NDES service. By default HTTP is used. E.g.: http://myserver or http://10.192.5.1
SCEP User name This is a user in your Active Directory which has the required permission to access the NDES service and request the challenge password. To be sure of this, the user should be part of the CA Administrators group (in case of a stand-alone CA) or have enroll permissions on the configured certificate templates.
SCEP Password The corresponding password for the identity that you are using to authenticate on the corporate network. Per Base Unit, every Button uses the same identity and password to connect to the corporate network.
Click Save Changes to save the settings.
EAP-TTLS (Tunneled Transport Layer Security) is an EAP implementation by Juniper networks. It is designed to provide authentication that is as strong as EAP-TLS, but it does not require each user to be issued a certificate. Instead, only the authentication servers are issued certificates. User authentication is performed by password, but the password credentials are transported in a securely encrypted tunnel established based upon the server certificates.
User authentication is performed against the same security database that is already in use on the corporate LAN: for example, SQL or LDAP databases, or token systems. Since EAP-TTLS is usually implemented in corporate environments without a client certificate we have not included support for this. If you prefer using client certificates per user we suggest using EAP-TLS.
SCEP ServerIP/ hostname


Image 6–22 Wi-Fi Settings, Wireless Client, EAP-TTLS
PEAP (Protected Extensible Authentication Protocol) is an EAP implementation co-developed by Cisco Systems, Microsoft and RSA Security. It sets up a secure TLS tunnel using the servers CA certificate after which actual user authentication takes place within the tunnel. This way of working enables it to use the security of TLS while authenticating the user but without the need for a PKI.
The standard does not mandate which method is to be used to authenticate within the tunnel. But in this application note, with regard to PEAP, we are referring to PEAPv0 with EAP-MSCHAPv2 as the inner authentication method. This is one of the two certified PEAP implementations in the WPA and WPA2 standards – and by far the most common and widespread implementation of PEAP.


Image 6–23 Wi-Fi Settings, Wireless Client, PEAP
The SSID of your corporate wireless infrastructure to which the ClickShare Buttons will connect.
The following formats are allowed:
File should at least contain the root CA certificate for your domain.
WPA2-PSK does not distinguish between individual users, there is 1 password (PSK – Pre-Shared Key) for all clients connecting to the wireless infrastructure. This makes setup very straightforward. Once connected, all data transmitted between client and AP (access point) is encrypted using a 256 bit key.


Image 6–24 Wi-Fi Settings, Wireless Client, WPA-PSK
The SSID of your corporate wireless infrastructure to which the ClickShare Buttons will connect.
The key used in WPA2-PSK to authenticate onto the wireless infrastructure. This can be a string of 64 hexadecimal digits or a passphrase of 8 to 63 printable ASCII characters.
A network connection can be configured through DHCP or by manually entering a fixed IP address.
DHCP Dynamic host configuration protocol. DHCP is a communications protocol that lets network administrators manage centrally and automate the assignment of IP addresses in an organization's network. Using the Internet Protocol, each machine that can connect to the Internet needs a unique IP address. When an organization sets up its computer users with a connection to the Internet, an IP address must be assigned to each machine. Without DHCP, the IP address must be entered manually at each computer and, if computers move to another location in another part of the network, a new IP address must be entered. DHCP lets a network administrator supervise and distribute IP addresses from a central point and automatically sends a new IP address when a computer is plugged into a different place in the network.


Image 6–25 LAN settings
The default host name is ClickShare-<serial number Base Unit>.
When Automatic (DHCP) is selected, the IP address, subnet mask and default gateway fields are grayed out but the currently used settings are filled out.
The IP address, subnet and gateway input fields are activated.

Do not use IP address 192.168.2.x for a Subnet mask 255.255.255.0 and IP address 192.168.x.x for a Subnet mask 255.255.0.0
This setting is important for the auto-update feature of the Base Unit, which require internet access.

Image 6–26 Proxy settings
The proxy settings become available.
Some proxy servers need a port number, user name and password, for others is this optional.
The ClickShare app is enabled by default and makes it possible to connect with a mobile device to the Base Unit.
Before you can stream information and display it via ClickShare your device must be connected with the wireless network of the Base Unit. Then AirPlay must be activated on your device. For more information about activating AirPlay, consult the user guide of your device.
The supported versions of AirPlay can be found on Barco’s website, www.barco.com\clickshare. The support of non-released version of these protocols cannot be guaranteed by Barco.
Before you can mirror information and display it via ClickShare your device must be connected with the wireless network of the Base Unit. When activating Google Cast on your device an overview of the access points is given. For more information about using Google Cast, consult the user guide of your device.
The supported versions of Google Cast can be found on Barco’s website, www.barco.com\clickshare. The support of non-released version of these protocols cannot be guaranteed by Barco.

Google Cast does not support a passcode.
Google Cast can only be used when the clock of the Base Unit is set correctly. If not Google Cast cannot make a connection with the Base Unit.
About streaming via Miracast™
Miracast™enables seamless display of multimedia content between Miracast® devices. Miracast allows users to wirelessly share multimedia, including high-resolution pictures and high-definition (HD) video content between Wi-Fi devices, even if a Wi-Fi network is not available.
Miracast sets up its own network to stream information and display it via ClickShare so there is no need for a direct connection with the Base Unit. Miracast must be activated on your device. For more information about activating Miracast, consult the user guide of your device.
The supported versions of Miracast can be found on Barco’s website, www.barco.com\clickshare. The support of non-released version of these protocols cannot be guaranteed by Barco.
To be able to use Miracast, you need to disable the access point and integrate the Buttons into the corporate network.

Image 6–27 Services, mobile devices
To allow streaming via AirPlay, check the check box in front of Streaming via AirPlay.
To allow streaming (mirroring) via Google Cast, check the check box in front of Streaming via Google Cast. Google cast does not support a passcode.
To allow streaming via Miracast, check the check box in front of Streaming via Miracast.

Passcode applies to all BYOD screen sharing except Google Cast.
The API can be enabled or disabled, that means that the access to the unit from an external device can be allowed or can be blocked.
This functions in enabled by default.
The API documentation is included in the Base Unit. Just click on View API documentation to access to the documentation. Enter your user name and password to access the stored documentation on the Base Unit.
The default user name and password are identical to those of the configurator (admin/admin). This can be changed in Security →Passwords.

Image 6–28 ClickShare API & documentation
This check box is normally checked by default.
Checked: remote control via API is allowed. A password can be used to protect the access.
Not checked: no remote control via API allowed.
The complete API documentation for integration by 3th parties is stored on the Base Unit and protected by user name and password.
The documentation is displayed as a clickable HTML page.
Simple Network Management Protocol (SNMP) is an internet standard protocol for collecting and organizing information about managed devices on IP networks and for modifying that information to change device

behaviour. In general a SNMP management suite (running on a server) communicates with an SNMP agent (running on the device). The SNMP agent collects and exposes device information in the form of variables according a MIB (Management Information Base). SNMP management suites will be able to approach ClickShare devices via SNMP protocol for requesting device information.
SNMPv3 is supported.

Image 6–29 Service, SNMP
The configuration fields become available.
The default engine ID is a combination of the Barco Enterprise Number with the MAC-address (eth0).
That is the host address which will receive the TRAP events/messages. Possible traps can be:
For the use of the ClickShare system, a security level can be set. By default, level 1 is activated. A security level is a predefined set of settings which are automatically set when a level is selected.
Level 1: offers support for normal day-to-day operations in any organization.
Level 1 contains the standard security options and encryption of audio and video data.
The standard security options are:

Level 2: this level offers a higher degree of security, fit for organizations that are more sensitive to security matters.
Level 2 contains the level 1 security and a mandatory PIN code for mobile devices. Alphanumeric PIN codes for mobile apps and Buttons and the Buttons require a certificate for pairing.
Level 3: this level is used for organizations that have extremely strict requirements with regards to security.
Level 3 contains the level 2 security extended with blocking of mobile apps, downgrading firmware not possible and no wireless access to the Configurator (WebUI).
When a security level is set, the individual items included in that security level can be changed using the individual item in the Configurator. When changing an individual item the security level indication will be adapted accordingly, but no other settings will be changed automatically.
E.g. when level 3 is set and you change mobile app blocking to allowed, then the security level indication will change to level 2. But all other items initially in level 3 remains in the level 3 state.
To reset your individual changes, select the desired security level and click Save changes.
Changing the security level will require a re-pairing of the Buttons. Changing the security level from 1 to a higher level will change the compatibility setting for Buttons with certificate (R9861006D01). They cannot re-pair as long as the security setting is higher than level 1.

Image 6–30 Security levels

To access the ClickShare Configurator a user name and password is needed. That password can be changed at any time to protect the ClickShare Configuration settings.

Image 6–31 Passwords
The following information can be found:


Image 6–32
A ClickShare system reboot message with progress bar is displayed while rebooting takes place.
When the reboot is finished, a re-login is necessary.
The date and time can be set manually using the time zone indication or using at least one NTP servers.


Image 6–33 Manual time & date update
The current time is indicated next to Current time.
A calendar window opens. The current date is indicated with a red background.

Image 6–34 Date selection
Click on a number in the number field to setup the day.
A window with 3 scroll counters open.

Image 6–35 Time setup

The clock is continuously synchronized with an external time server and the deviation is in the order of milliseconds. Extra time servers can be added.
As long as there is no synchronization with a time server the status is indicated as disabled.

Image 6–36 Time server setup
The current time is indicated next to Current time.
A synchronization with the NTP server takes place. The status field indicates the progress.
Standby after (minutes): If there is no client connection detected during the standby timeout period, the Base Unit will enter the selected standby mode.
Default setting: Time to standby: 10 min, the Base Unit will enter the Eco standby mode.

When the Base Unit enters ECO standby mode, it will disable the HDMI output signal. The Base Unit's LEDs will be breathing white to indicate the ECO standby mode.
The Base Unit will wake up with one of the following actions:
When the Base Unit goes in Deep standby mode, it will shut down all processes, including the Wi-Fi access point and LAN connection. The Base Unit's LEDs will be dark to indicate this standby mode.
The Base Unit will wake up only when the standby button on the Base Unit is pressed.

Image 6–37 Energy savers
The Button page indicates to which Base Unit or network the Buttons are connected. It indicates also the current state.
When connected to a network, it indicates the domain, the identity and provided certificate.
Eco mode · Standby mode

All Buttons used with the Base Unit are indicated in the Buttons List. The list contains the serial number, MAC address, article code and the firmware version, the number of connections and last connection date and time.
It is possible to update the software of the Buttons over Wi-Fi.
The Buttons can be connected to Base Unit or to an external access point.

Image 6–38 Buttons overview
The current state is indicated and the list of Buttons is given.
Depending on the selection, your ClickShare device or external access point, settings should be filed out.
For your ClickShare device, no settings are needed.


Image 6–39 Buttons, External access point, mode EAP-TLS
The SSID of your corporate wireless infrastructure to which the ClickShare Buttons will connect.
Allowed file formats:
The should at least include the client certificate and corresponding private key.
The following formats are allowed:
File should at least contain the root CA certificate for your domain.
The Simple Certificate Enrolment Protocol (SCEP) is a protocol which enables issuing and revoking of certificates in a scalable way. SCEP support is included to allow a quicker and smoother integration of the

ClickShare Base Unit and Buttons into the corporate network. Since most companies are using Microsoft Windows Server and its active directory (AD) to manage users and devices our SCEP implementation is specifically targeted at the Network Device Enrolment Service (NDES) which is part of Windows Server 2008 R2 and Windows Server 2012. Initial support for other generic servers is available by extending the possible parameters to use for NDES/SCEP enrolment.
Image 6–40 Buttons, EAP-TLS, SCEP
This is the IP or hostname of the Windows Server in your network running the NDES service. By default HTTP is used. E.g.: http://myserver or http://10.192.5.1
SCEP User name This is a user in your Active Directory which has the required permission to access the NDES service and request the challenge password. To be sure of this, the user should be part of the CA Administrators group (in case of a stand-alone CA) or have enroll permissions on the configured certificate templates.
SCEP Password The corresponding password for the identity that you are using to authenticate on the corporate network. Per Base Unit, every Button uses the same identity and password to connect to the corporate network.
Click Save Changes to save the settings.

Image 6–41 Buttons, External access point, mode EAP-TTLS
The SSID of your corporate wireless infrastructure to which the ClickShare Buttons will connect.
SCEP ServerIP/ hostname

The following formats are allowed:
File should at least contain the root CA certificate for your domain.

Image 6–42 Buttons, External access point, mode PEAP
The SSID of your corporate wireless infrastructure to which the ClickShare Buttons will connect.
The following formats are allowed:
File should at least contain the root CA certificate for your domain.


Image 6–43 Buttons, External access point, mode WPA2-PSK
The SSID of your corporate wireless infrastructure to which the ClickShare Buttons will connect.
The key used in WPA2-PSK to authenticate onto the wireless infrastructure. This can be a string of 64 hexadecimal digits or a passphrase of 8 to 63 printable ASCII characters.
Only available on C-10.
Saving information from a blackboard can be enabled or disabled. When enabled, the information is saved on hard disk of all connected Buttons, connected ClickShare apps and on the USB sticks connected with the Base Unit.


Image 6–44 Save annotations
Checked: annotations on the blackboard can be saved.
Unchecked: no annotations on the blackboard can be saved.
When your device is not registered and connected to the cloud service, the following message will be displayed: The ClickShare device is unable to connect to the cloud service. Make sure the network settings are correctly configured.
When your device is correctly registered, the following message is displayed: The ClickShare device has been successfully registered.

Image 6–45 XMS cloud

Follow procedure as described in “Registration to XMS Cloud”, page 46.
The SmartCare package is included in the purchase of each ClickShare unit.
For those rare occasions when you encounter issues with our ClickShare units., we have launched SmartCare, a service package that provides your company with budget predictability, swift hardware replacement and expert support from both Barco and our partners for up to 5 years.
When SmartCare is activated, in the SmartCare pane the message SmartCare active, valid until... is displayed.
When not yet activated, you have 6 months after the first setup to activate SmartCare and enjoy 5 years of hardware coverage.
When the activation period is expired, the warranty end date will be displayed.
The firmware of the Base Unit can be updated via the web interface. The latest version of the firmware is available on Barco's website.

Image 6–46 Firmware update
There are 3 ways to configure automatic updates:

A browser window opens.
The Base Unit software is updated.
If a firmware downgrade is required on the Base Unit, check the check box in front of Allow firmware downgrade.
Next to using the configurator to upgrade the firmware, the following ways are also possible:
Both Button and Base Unit log data is saved in log files on the Base Unit. These log files can contain debugging information. They can be downloaded on a local computer and cleared on the Base Unit. Debug logging covers only a few hours before it will be overwritten. Therefore, it is important if you discover a problem with your system to download the logging immediately.


Image 6–47 Troubleshoot, logging
When erasing all settings, the device settings are reverted to defaults. There is no need to go through the onboarding procedure.
The device will not be removed from the organization account in XMS cloud.

Image 6–48 Troubleshoot, logging
When applying a reset to factory defaults, the device settings are reverted to the factory defaults. Additionally, the Base Unit will be removed from the organization account in XMS cloud and the first time setup procedure will be initiated, as if the device came out of the box.
The unit needs to be connected to the internet to complete the first time setup.


Image 6–49 Factory reset
The following message is displayed: “This action will remove all settings of the Base Unit and replace them with the default settings. Are you sure you want to continue?”
When yes is clicked, the system starts a reboot.




When starting up the device for the first time a software update is necessary. This update can only be done via the network.
There are different ways to update the Base Unit software:
To update the Base Unit software by copying the software on a USB stick
You can have multiple firmwares for multiple device types on the same stick.
The Base Unit reboots.
Firmware updates


Quality of the image on the meeting room display is not satisfactory
The quality or length of the cable between the Base Unit and the display or the connection between these two.
Bad resolution of the display The system can handle the average laptop resolution of 3 Megapixel. However, up or down scaling on the meeting room display can cause visible artefacts.
Change the resolution on the web interface and match it to the native resolution of the meeting room display.
Users have a bad wireless connection. The connection from the Button to the Base Unit keeps falling away.
Wireless congestion • Use a WiFi scanner to find a free wireless channel and select it via the web interface. You can use commercial as well as free online tools such as inSSIDer or Xirrus for this. Refer to “WiFi settings”.
Users do not get a ClickShare drive when inserting the Button in their laptop.
Bad connection at USB port on the laptop
If possible, change the USB port policy on the laptop.
Troubleshooting · Problem Cause Solution

Wireless connectivity See “Users have bad connectivity”
Some programs of Windows are not shown on the display
Use of overlays, 3D or hardware acceleration in the GPU
When using Windows 7 the following message about the Windows Aero color scheme appears: "Windows has detected your computer's performance is slow. This could be because there are not enough resources to run the Windows Aero color scheme. To improve...".
ClickShare uses resources from the GPU. In combination with other programs which do so, Windows 7 sometimes shows this message suggesting to disable Aero to improve the performance of your laptop.
It is safe to ignore this message and choose 'Keep the current color scheme'.
Your screen is not shown on the display when pressing the Button
The number of shared video’son the screen is exceeded. When roomdock is used, only one participant can share his screen.
Click and hold the button for 2 seconds to use the Show me full screen function.
The ClickShare software is not running.
Go to the ClickShare drive and run the software.
Your content is removed from the display and the LEDs on the button are blinking white
Connection to the Base Unit is lost.
ClickShare tries to restore the connection automatically. If it fails, the LEDs on the Button start blinking red. Unplug the Button from your laptop and try a new Button.
Noting is shown on the displays at all.
The displays are switched off. Switch on the displays.
The display cable is not correctly connected
Insert the display cable to the display and the Base Unit.
The display does not recognize or is not able to display the Base Unit output resolution.
Change the corresponding setting via the web interface.
The Base Unit is in standby mode Briefly push the standby button on the Base Unit or insert a Button and run the ClickShare software.
Troubleshooting · Problem Cause Solution

Bad WiFi connectivity Congestion of the wireless channel
Use wireless network scan tools to look for free or the least congested channels.
Metal cabinets, walls, construction elements, ... can cause reflections deteriorating the wireless signal. Obstructions between Buttons and Base Unit cause lowering of the wireless strength and quality.
Move the Base Unit to another place in the room.
Avoid placing it inside cabinets, false ceiling, below the table, behind a wall, in another room,
Re-orient the Base Unit antennas
Check out the ClickShare White paper on WiFi See www.barco.com/clickshare.
Web Interface shows error in the processes “WiFi Access Point Daemon” and/or “DHCP Server”
Configuration file is corrupted Browse to the Configuration tab on the Web Interface and press “Load Default Settings”.
ClickShare Base Unit does not start up correctly
Configuration file is corrupted Browse to the Configuration tab of the Web Interface and press “Load Default Settings”.
No LAN connection with the Base Unit
Wrong IP address IP address is not within your LAN range.
DHCP is not enabled.
No WiFi connection with Base Unit SSID not correct Enter the correct SSID
Locate the problem you are experiencing in the table below and apply the solution.
Go to the product page on Barco’s website and select in the right column Support. You will get access to Barco’s Knowledge base and Latest tutorial videos. For more YouTube videos, consult https://www.youtube.com/user/barcoTV and select ClickShare.
Troubleshooting · Problem Cause Solution


Button 103 First setup
Personalized wallpaper 72 Wallpaper
Base Unit 45 Full backup 74
Wallpaper 71 Portable version 74 Prepare
R
Installation 37 Base Unit
Methods 38 Ceiling mounting
Base Unit 38 Network connected setup 41 Dedicated 41 Out-of-the-box 40 Table mounting
Environment condition check 36 Security level 90 Services
Base Unit 38 Wall mounting
Mobile devices 87 SNMP 89 Specifications 27 C-10, C-5 29 Start up
Base Unit 38 Introduction 25 Fonts 26 symbols 26
First time 44 Status information 92 Symbols 26 System
LAN settings 85 Language 69 Location name 69 Log settings 104
Base Unit 38 Troubleshoot
Log settings 104 Troubleshooting 111 Logging 105 Troubleshooting list 112
Meeting room name 69 Mobile Device
Support 33 Mobile devices 87
N
Base Unit 103 Button 103 Upload configuration 74
Basic configuration 51 Network settings
Setup 51 Out-of-the-box 40
Wallpaper 71 Personalized 72 WebUI password 92 Welcome text 69 Wi-Fi settings 76–77 Wireless client 79 EAP-TLS 80 EAP-TTLS 82 PEAP 83 WPA-PSK 84
Button 56 Passwords 92 Peripherals 76 Persnalisation


Index



Wi Fi
Owners and our team usually reply within a day — and your question helps the next person too.