EN
Official user manual

PSI SpectraPen Mini Software

15 pages·358 KB·Software·PDF·ENDEFRITNLJA
PSI SpectraPen Mini Software
Table of Contents 8 sections 1 Software installation · 2 Data transfer · 3 Software menu · 4 Data visualization · … ShowHide
Page 1 of the PSI SpectraPen Mini Software user manual
Page 1 · click to enlarge
Page 1
PSI SpectraPen Mini Software diagram (page 1)
Fig. 1
Page 2 of the PSI SpectraPen Mini Software user manual
Page 2 · click to enlarge
Page 2

Manual Version: 2022/01 © PSI (Photon Systems Instruments), spol. s r.o.

www.psi.cz

This document and its parts can be copied or provided to a third party only with the express permission of PSI.

The contents of this manual have been verified to correspond to the specifications of the device. However, deviations cannot be ruled out. Therefore, a complete correspondence between the manual and the real device cannot be guaranteed. The information in this manual is regularly checked, and corrections may be made in subsequent versions.

The visualizations shown in this manual are only illustrative.

This manual is an integral part of the purchase and delivery of equipment and its accessories and both Parties must abide by it.

Page 3 of the PSI SpectraPen Mini Software user manual — T ABLE OF C ONTENT
Page 3 · click to enlarge
Page 3

T ABLE OF C ONTENT

1 Software installation 4

2 Data transfer 4

3 Software menu 6

4 Data visualization 7

5 Troubleshooting and Customer Support 12

6 Appendix 12

6.1 Programming custom index in SpectraPen 12

6.1.1 Function description 13

Page 4 of the PSI SpectraPen Mini Software user manual — 2 D ATA TRANSFER
Page 4 · click to enlarge
Page 4

1 S OFTWARE INSTALLATION

PSI SpectraPen Mini Software — 1 S OFTWARE INSTALLATION diagram (page 4)
Fig. 2
1. Download the SpectraPen software from PSI website https://handheld.psi.cz/products/spectrapenmini/#download to your computer and launches the SpectraPen program. 2. To activate all software features register the SpectraPen software as follows (Fig. 1).
  • Select: Help > Register
  • Enter serial registration number, which is available in download section on PSI website
  • Select: OK

Fig. 1 Software registration.

It is not possible to download data from the SpectraPen device without software registration.

2 D ATA TRANSFER

For data transfer from mobile application to your computer select Share and choose your preferred option (Fig. 2).

PSI SpectraPen Mini Software — 2 D ATA TRANSFER diagram (page 4)
Fig. 3

Fig. 2 Data export and sharing via available communication channels.

It is not possible to download data from the SpectraPen device without software registration.

Page 5 of the PSI SpectraPen Mini Software user manual — 1 Software installation
Page 5 · click to enlarge
Page 5

Open your data in .spec format using the SpectraPen software (Fig. 3).

PSI SpectraPen Mini Software — 1 Software installation diagram (page 5)
Fig. 4 · 1 Software installation

Fig. 3 Opening data in SpectraPen software.

Page 6 of the PSI SpectraPen Mini Software user manual — 3 S OFTWARE MENU
Page 6 · click to enlarge
Page 6

3 S OFTWARE MENU

MENUFile
PSI SpectraPen Mini Software — 3 S OFTWARE MENU diagram (page 6)
Fig. 5

Load Loads previously saved data files.

Save Saves data to hard disc.

Export Exports data in .txt format.

Export to JSON Exports data in JavaScript Object Notation.

Close Closes the current experiment.

Close All Closes all open experiments.

Exit Exits the program.

MENUDevice – NOT ACTIVE FOR SP mini
PSI SpectraPen Mini Software — 3 S OFTWARE MENU diagram (page 6)
Fig. 6

Connect Detects and connects the device.

Update Firmware Used for firmware updates.

Attach GPS File Used to download data from the GPS module of the old versions of the SpectraPen or PolyPen.

Memory Erase Erases data from the memory of connected device.

Online Control Online control of the device.

MENUSetup
PSI SpectraPen Mini Software — 3 S OFTWARE MENU diagram (page 6)
Fig. 7

Update Software Used for software updates.

Settings On/off – Auto memory erase after download.

Selection of separator for the csv file after its export and following opening in Excel (TAB, SEMICOLON, COMMA, SPACE).

MENUHelp
PSI SpectraPen Mini Software — 3 S OFTWARE MENU diagram (page 6)
Fig. 8

Registration Used for the SpectraPen software registration.

About Offers basic information about the program.

Page 7 of the PSI SpectraPen Mini Software user manual — 4 D ATA VISUALIZATION
Page 7 · click to enlarge
Page 7

4 D ATA VISUALIZATION

1. Visualization modes: Scope mode window is always displayed as the default. To view irradiance data go to Irradiance tab (Fig. 4).

Scope mode represents non-calibrated spectrum.

PSI SpectraPen Mini Software — 4 D ATA VISUALIZATION diagram (page 7)
Fig. 9

Fig. 4 Scope spectra.

2. All data that are downloaded are displayed in the Scope window after download from the SpectraPen. The user can select the set of measurements to be displayed by marking and unmarking the data from the selection list (Fig. 4). 3. Right click on list of measured data enables edit data name, delete selected measurement or show and hide all measured data in the graph– Select all measure and Clear all measure (Fig. 5).
PSI SpectraPen Mini Software — 4 D ATA VISUALIZATION diagram (page 7)
Fig. 10

Fig. 5 Options for list of data.

Page 8 of the PSI SpectraPen Mini Software user manual — 4 Data visualization
Page 8 · click to enlarge
Page 8
4. In the graph marker feature is available, which enables display of the numeric values for wavelength and light irradiance for the selected wavelength of the scan (Fig. 6). Use the mouse to select the given point. In top right corner of the graph (red rectangle) is displayed exact value for the selected point on the x-axis and y-axis.
PSI SpectraPen Mini Software — 4 Data visualization diagram (page 8)
Fig. 11 · 4 Data visualization

Fig. 6 Marker feature.

5. To zoom in on the data displayed in the graph select an area of the displayed graph (Fig. 7). To reverse these steps and return to original display use minus icon in the corners of the zoom area marked with red rectangles in Fig. 7.
PSI SpectraPen Mini Software — 4 Data visualization diagram (page 8)
Fig. 12 · 4 Data visualization

Fig. 7 Zoom function.

Page 9 of the PSI SpectraPen Mini Software user manual — 4 Data visualization
Page 9 · click to enlarge
Page 9

6. Select Irradiance tab to view the irradiance data stored either as umol/m2/s/nm or per µWatts/cm2/nm. To change the units in which the spectra is displayed click on the unit icon as shown in (Fig. 8). 7. To view the light meter data for the spectral scans acquired click on the unit icon as depicted by red arrow in Fig. 8. Irradiance and illuminance light meter numerical values for each scan are displayed as LUX, PAR or IRRADIANCE values (Fig. 9).

PSI SpectraPen Mini Software — 4 Data visualization diagram (page 9)
Fig. 13 · 4 Data visualization

Fig. 8 Irradiance shown in different units.

PSI SpectraPen Mini Software — 4 Data visualization diagram (page 9)
Fig. 14 · 4 Data visualization

Fig. 9 Numerical values of measured light intensities.

Page 10 of the PSI SpectraPen Mini Software user manual — 4 Data visualization
Page 10 · click to enlarge
Page 10

8. To Save the experiment select File>Save. All data stored in the device memory will be saved irrespective of the data selection in the SpectraPen software. The file will be stored as .spec. Spec files stores all Scope and Light meter data. 9. Select File>Export to export the data in .txt format. Export function allows the user to specify the type of data. The options are: Spectrum (Fig. 10) – all raw scope data for entire range of measured wavelengths are exported including data for the dark scan. Spectrum scope – scope data normalized to dark spectrum scan are exported for all acquired scans or set of selected measurements.

PSI SpectraPen Mini Software — 4 Data visualization diagram (page 10)
Fig. 15 · 4 Data visualization

Fig. 10 Export options.

Spectrum Irradiance – irradiance data for all measurements are exported. The user can choose to export the numeric values either in µE/m2/s/nm, µW/cm2/nm or both (Fig. 11).

PSI SpectraPen Mini Software — 4 Data visualization diagram (page 10)
Fig. 16 · 4 Data visualization

Fig. 11 Export of Irradiance spectrum.

Computed Data – computed numeric values for Scope and Irradiance are exported for all measurements. The user can choose if only Scope numeric values or Irradiance numeric values are exported. For irradiance values, numeric data for Photon flux density and PAR in µmol/m2/s units, irradiance in µW/cm2 units and illuminance in LUX units are exported (Fig. 12).

Page 11 of the PSI SpectraPen Mini Software user manual — 4 Data visualization
Page 11 · click to enlarge
Page 11

Export interpolation – if this option is marked the spectrum is exported with step of 1 nm.

PSI SpectraPen Mini Software — 4 Data visualization diagram (page 11)
Fig. 17 · 4 Data visualization

Fig. 12 Export of computed values.

Page 12 of the PSI SpectraPen Mini Software user manual — 6 A PPENDIX
Page 12 · click to enlarge
Page 12

5 T ROUBLESHOOTING AND C USTOMER S UPPORT

In case of problems with the SpectraPen SW visit FAQ on our websites (http://psi.cz/support/faq) or contact customer support by email to [email protected], or contact your local distributor.

6 A PPENDIX

6.1 P ROGRAMMING CUSTOM INDEX IN S PECTRA P EN

The SpectraPen software enables programming custom indexes, which can be used for wide range of calculation based on the measured spectrum.

1. Go to the main SpectraPen folder in your PC (Usually in Program Files). 2. Open the file Config > Formulas.txt. 3. Write your index into this .txt file and save it (Fig. 13). Index example: Scope:PSIindex:PSI test index:Scope[600nm]/ Scope[500nm] Scope – the index is placed in the bookmark Scope in data in the software PSIindex – name of the index in the SpectraPen software and in exported data PSI test index – full name of the index (not showed) Scope[600nm]/ Scope[500nm] – equation for calculation; calculated from 500 and 600 nm of Scope spectra

PSI SpectraPen Mini Software — 6 A PPENDIX diagram (page 12)
Fig. 18

Fig. 13 New index in the Formulas file.

4. Restart the SpectraPen Software. 5. The new index appears in the selected bookmark in the data (Fig. 14). 6. For export of this index choose the option “Computed values” and selected spectrum in the export table.
Page 13 of the PSI SpectraPen Mini Software user manual — 6.1.1 F UNCTION DESCRIPTION
Page 13 · click to enlarge
Page 13
PSI SpectraPen Mini Software — 6.1.1 Function description diagram (page 13)
Fig. 19 · 6.1.1 Function description

Fig. 14 New index.

6.1.1 F UNCTION DESCRIPTION

Different mathematical functions can be used in SpectraPen software syntax to create new custom formulas.

value1 - number, variable, function

value2 – number, variable, function

- only one value can be function!

array – array of numbers

example1max(Scope)
example2min(Irradiance)
example3min(Scope[760nm], max(Scope[450], Scope[680]))
example4max(Irradiance[550nm], (5+4)*4)

ln – the natural (base e) logarithm of specified number

value – number, variable, function

example1ln(5)
example2ln(Irradiance[760nm])
Show 5 more labels / short text on this page
min, max - · min(value1, value2) · min(array) · __________________________________________________________________________ · ln(value)
Page 14 of the PSI SpectraPen Mini Software user manual — 6.1.1 Function description
Page 14 · click to enlarge
Page 14
example3ln(max(Irradiance [550nm], Irradiance[480nm]))
example4ln((5+4)*4)

log – the logarithm of specified number in a specified base.

B – base - number

value – number, variable, function

example1log2(5)
example2log5(Scope[760nm])
example3log10(max(Scope[550nm], Scope[480nm]))
example4log10((5+4)*4)

sqrt – the square root of a specified number

value – number, variable, function

example1sqrt(5)
example2sqrt(Scope[760nm])
example3sqrt(max(Scope[550nm], Scope[480nm]))
example4sqrt(((5+4)*4) + 6)

^ - specified number raised to the specified power

value – number, variable, function

power – number, variable, function

example1Irradiance[760nm]^ Irradiance[550nm]
example2min(Irradiance[760nm], Irradiance[550nm])^max(Irradiance[435nm], Irradiance[430nm])
example3Transmitance[760nm]^0.5

integral - express the area under the curve of a graph of the function in the interval

function_values – input values for integral compute

from,to – limit values

Show 8 more labels / short text on this page
__________________________________________________________________________ · logB(value) · __________________________________________________________________________ · sqrt(value) · ____________________________________________________________________________ · value^power · ___________________________________________________________________________ · integral(function_values, from, to)
Page 15 of the PSI SpectraPen Mini Software user manual — 6.1.1 Function description
Page 15 · click to enlarge
Page 15
example1integral(IrradianceL, 360nm, 700nm)
example2integral(IrradianceE, 360nm, 700nm) * IrradianceE[450]
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the PSI SpectraPen Mini Software

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the PSI SpectraPen Mini Software

Be the first to ask — other owners or our team will answer.

Original document

PSI SpectraPen Mini Software manual PDF

15 pages·358 KB·Software·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…