ENGLISH



Thank you for purchasing a PIEPS beacon! Register your PIEPS beacon in the PIEPS APP (iOS, Android) or at my.pieps.com and get:
- A warranty extension free of charge - Important information about software updates Your PIEPS beacon includes all tried and tested PIEPS features:
An avalanche beacon does not protect against avalanches! Detailed knowledge of avalanche prevention is as indispensable as regularly practicing victim searches in an emergency. The following procedures and tips relate only to special usage in conjunction with the PIEPS beacon. The basic line of action in an emergency – as explained in specialist publications and material from avalanche courses – must be followed.
With the PIEPS beacon you have a product that is state of the art in terms of safety and user-friendliness. Despite this, the PIEPS beacon can pose risks if used inappropriately or incorrectly. We refer to possible hazards in chapter 2 and with safety notes placed throughout the operating manual. This operating manual is intended to ensure the safe use of the PIEPS beacon. The safety instructions in this document must be followed at all times. Before you use the PIEPS beacon, you must have read and understand this operating manual.
Pieps GmbH is not liable for technical or printing errors in this operating manual, neither is any liability accepted for damage caused directly or indirectly by the delivery, performance or use of this operating manual.
Copyright © Pieps GmbH, 04/2021 This translation of the original manual is protected by copyright. All rights, especially the rights of reproduction, distribution and translation, are reserved. No part of this document may be reproduced or stored, processed, duplicated or distributed using electronic systems in any form (photocopy, microfilm or other method) without the written consent of Pieps GmbH. Violations may incur criminal penalties.

In accordance with applicable regulations, the following marks may be found on the PIEPS beacon or/and on the packaging:
CE mark of conformity: indicating the fulfillment of the following standards: EMV 2014/30/EU, RED 2014/53/EU, RoHS 2011/65/EU.
Dustbin symbol: advising users to dispose of waste electrical and electronic equipment separately from unsorted municipal waste. FCC ID FCC ID: indicating the compliance with Part 15 of the FCC Rules. IC ID IC ID: indicating the compliance with Industry Canada’s licence-exempt RSS standard(s).
Bluetooth® logo: The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Pieps GmbH is under license. Other trademarks and trade names are those of their respective owners. SN 12 digit serial number: identifying the device and is used for device registration.
Recycling symbol.
Battery symbol: indicating battery type and correct position.
Instruction pictogram: advising users to read the instructions and warnings.
PIEPS brand name.
PIEPS logo.
The information contained in this operating manual describes but does not guarantee the features of the product. No liability is accepted for damage caused by:

The manufacturer provides a 2-year warranty covering manufacturing and material defects of the PIEPS beacon from the date of purchase. Exceptions are the battery, carrying system, hand-loop and bag as well as any damage caused by improper use or dismantling of the device by unauthorized persons. Any other warranties and liability for consequential damage are expressly excluded. For warranty claims, please take proof of purchase and a description of the fault to the point of sale. 1.4 MANUFACTURER ADDRESS & SUPPORT
Pieps GmbH, Parkring 4, 8403 Lebring, Austria For technical problems, please contact the support: support@pieps.com 1.5 INTENDED USE
The PIEPS beacon serves as an avalanche victim search device (avalanche transceiver) for the localization of buried persons and must only be used as intended. Any other use requires the written consent of Pieps GmbH. Improper use can put individuals at risk and result in the device being damaged. The PIEPS beacon is not an automatically functioning device with partly automated functionalities – for this reason, the PIEPS beacon may only be commissioned after having read and understood the documentation. Failure to use the device as intended will result in all liability and warranty claims being rejected. The PIEPS beacon is to be operated only under the conditions of use described in the documentation. 1.6 TARGET GROUP AND PREVIOUS KNOWLEDGE
An avalanche beacon should be part of the avalanche emergency equipment of everyone who ventures off from the secured piste into open, unsecured terrain (e.g. ski touring, freeriding, mountain rescue operations, etc.). Users of the PIEPS beacon must meet the following conditions:
as the instructions in the documentation without problem.
correctly interpret the display indications in accordance with the instructions in the operating manual.
The PIEPS beacon meets the current state of technology and the applicable health and safety regulations. However, incorrect operation or misuse can give rise to hazards for:

Name PIEPS MICRO BT sensor/button/RACE Transmission frequency 457 kHz
Field strength max. 7 dBµA/m (2,23 µA/m) at a distance of 10 m
Bluetooth transmission frequency 2.402 - 2.480 GHz
Bluetooth transmission power 0 dBm Power supply 1x Alkaline (AA) LR6 1.5 V or 1x Lithium (AA) FR6 1.5V
Battery lifetime 200 h (Alkaline), 350 h (Lithium) Search strip width 50 m
Dimensions (LxWxH) 106 x 74 x 20 mm Weight 150 g (incl. battery)
Temperature range -20° C to +45° C (-4° F to +113° F) Storage temperature range -25° C to +70° C (-13° F to +158° F)
This operating manual is structured in accordance with the applicable EU regulations and contains safety instructions. Each individual is personally responsible for complying with the safety instructions. This chapter contains all safety-related information. Should anything be unclear or difficult to understand, please contact our support team. 2.1 SIGNAL WORDS USED IN THE SAFETY INSTRUCTIONS
DANGER Imminent threat to the life of individuals A safety instruction with the signal word DANGER indicates an imminent threat to the life and health of individuals! WARNING Risk of personal injury (serious injuries) and possible material damage A safety instruction with the signal word WARNING indicates a dangerous situation which could affect the health of individuals. CAUTION Risk of material damage and possible minor risk of injury A safety instruction with the signal word CAUTION indicates a possibly dangerous situation which could primarily result in material damage. NOTICE This symbol with the text NOTICE indicates supporting information. 2.2 GENERAL SAFETY RULES AND OBLIGATIONS
The following safety rules and obligations apply in general for using the PIEPS beacon:

Even though the PIEPS beacon has been designed with maximum care and all safety-related facts have been taken into consideration, residual risks may exist and must be evaluated by means of a risk assessment. All residual risks and warnings from the risk assessment are listed in this chapter.
Only use batteries of type “Alkaline (AA) LR6 1.5 V or Lithium (AA) FR6 1.5V“! The use of Lithium batteries must be confirmed in the PIEPS APP!

PIEPS MICRO BT sensor
PIEPS MICRO BT button



1A
1A
1B
1B
1B
1H
1K
1K
1D
1D
1D
1J
1E
1E
1E
1F
1F
1F
1G
1G
1G
(1A) MARK button (1H) “Release SEARCH-LOCK ” info symbol* (1B) Transmit control LED (1J) Proximity-Sensor* (1C) (1D)
(1K) “Confirm SEND-SEARCH switch with MARK button” info symbol** (1E) Battery polarity (1L) SEND/SEARCH button** (1F) Main switch ON/OFF/access to battery compartment
LCD-Display (backlight) Battery compartment
* PIEPS MICRO BT sensor only ** PIEPS MICRO BT button/RACE only (1G) Loudspeaker


(2A) Bluetooth active (2B) Auxiliary display (2C) Battery capacity (2D) Group check (2E) Direction indicator (2F) Distance indicator (2G) SEARCH-LOCK (search mode blocked) * (2H) Transmit indicator (2J) MARK (marking possible) (2K) Current sending antenna (2L) Number of burials (1-3) (2M) Number of burials (4 or more) (2N) Transmitter marked * PIEPS MICRO BT sensor only
2B
2D
2E
2G
2F
2H
2J
2N
2K
2M


PIEPS recommends using the included carrying system (3A). The MICRO bag (3B) is for storage use. The included hand-loop (3C) is intended for training purpose.
The proximity-sensor (1J) is used for automatic switching from send to search mode. The sensor detects whether it is covered or not. This feature also works in darkness. 4.3.2 Switching on I Self-check I Send mode:
To turn on the PIEPS MICRO BT sensor, remove the beacon from the carrying system and switch it on by turning the main switch (1F) to the ON position. The switching on is confirmed with an acoustic (1x Pieps-tone) and haptic (1x Vibra) signal.

While switching on the beacon the following is displayed: current firmware-version is shown, the battery capacity/type, the status of the self-check (4A), the result of the self-check (4B) and the countdown for the group- check (4C). If the self-check is successful, “OK” is indicated on the display (4B). In the event of a device warning, an alert signal sounds and the display indicates “E” in combination with a warning-code (4E). After the self-check, place the PIEPS MICRO BT sensor into the carrying system. The PIEPS MICRO BT sensor emits an acoustic and tactile (Vibra) warning for 4 seconds that the device will switch over from search to send mode. The PIEPS MICRO BT sensor transmits (4F) and an LED indicator light (1B) flashes. In send-mode the transmitting symbol alternates with the AR-symbol (4F). AR stands for an active Auto-Revert Search-to-Send function. The Send-Vibra is an additional, haptic send confirmation (10x vibration).
4B
4E





Firmware Version Battery capacity/type (AL=Alkaline, LI=Lithium)
Self-check OK Group check countdown



system. Search mode is blocked in this case (SEARCH-LOCK, 2G).
system after the start sequence (switch-on). Search mode is not blocked in this case.
Sensor Test warning · Self-check Error · Send mode SEARCH-LOCK

SEARCH-LOCK To prevent accidental switching back to send mode during the search, search mode is blocked as soon as you take the PIEPS MICRO BT sensor out of its carrying system. The PIEPS MICRO BT sensor remains in search mode even if you return it to the carrying system during probing or digging. A blocked seach mode is indicated on the display with the SEARCH-LOCK symbol (4G).

If necessary, you can release the SEARCH-LOCK, by pressing the MARK button (1A) for 3 seconds and placing the PIEPS MICRO BT sensor in the carrying system or covering the sensor. The PIEPS MICRO BT sensor emits an acoustic and tactile (Vibra) warning for 4 seconds that the device will switch over from search to send mode. A tactile send confirmation is performed after the switchover (see Send-Vibra).
To turn on the PIEPS MICRO BT button/RACE, remove the beacon from the carrying system and switch it on by turning the main switch (1F) to the ON position. The switching on is confirmed with an acoustic (1x Pieps-tone)
and haptic (1x Vibra) signal.
While switching on the beacon the following is displayed: current firmware-version, the battery capacity/type, the status of the self-check (5A), the result of the self-check (5B), the countdown for the group-check (5C) and at the end the transmitting display with the active transmitting antenna (5D). If the self-check is successful, “OK” is indicated on the display (5B). In the event of a device warning, an alert signal sounds and the display indicates “E” in combination with a warning-code (5E). For error codes, see chapter 6.1. The PIEPS MICRO BT button/RACE transmits (4F) and an LED indicator light (1B) flashes. In send-mode the transmitting symbol alternates with the AR-symbol (4F). AR stands for an active Auto-Revert Search-to-Send function. The Send-Vibra is an additional, haptic send confirmation (10x vibration).
After the self-check, place the PIEPS MICRO BT button/RACE into the carrying system.

5B
5D
5E

Firmware Version Battery capacity/type (AL=Alkaline, LI=Lithium)
Self-check OK Group check countdown
Send mode Self-check Error
A secure switching from send mode to search mode is possible with the 2-button-activity.
Send Search Search Send Press the SEND/SEARCH button (1L) and confirm within the switching-countdown (5F) with the MARK button (1A). The PIEPS MICRO BT button is now in search mode (5G).
Press the SEND/SEARCH button (1L) and confirm within the switching-countdown (5F) with the MARK button (1A). The PIEPS MICRO BT button is now in send-mode (5D).


Umschalt-Countdown · Suchmodus (ohne Signalempfang) · Sendemodus

Despite a comprehensive self-check, a beacon check (transmit check and receive check) is obligatory prior to every tour! The PIEPS beacon provides the group check function. At the group check it is checked easy and efficient if the beacon of the partner is transmitting and if the transmitting parameters are according to the standard. In group check mode the receiving range is limited to 1 m.

Device not transmitting or distance too big (> 1 m)
Device not transmitting or distance too big (> 1 m)
More than one signals within 1 m range => increase distance
End Release the button MARK to end the group check mode. During the 3 seconds countdown the group check mode can be activated again. The Regular group check is sufficient for checking modern, digital devices with 3 antennas. The Extended group check is recommended for checking old devices (analogue single-antenna devices).

The PIEPS beacon additionally provides a pro-mode. The pro-mode allows a transmit check as well as a receive check without exiting the group check mode. By default, it is disabled and can be enabled in the PIEPS APP device manager.



Display in group check send mode CT = Check Transmit Standardmäßig ist der Pro-Mode deaktiviert. In der PIEPS APP kann das Feature aktiviert werden.
The full avalanche beacon check with pro-mode

Group leader => pro-mode SEARCH: device receiving? All others => send mode: devices transmitting? NOTICE The receive check can be combined with a range test by choosing a large distance (50 m).
Pro-Mode SEARCH · Pro-Mode SEND · (1) Receive check

Maximum background support in send mode and search mode! 4.6.1 PIEPS Interference Protection
If the transmitting antenna is impacted by external interference, the other antenna would take over the
transmit function. The PIEPS beacon always transmits with the strongest possible signal!
Only a verified 457kHz signal is indicated. The PIEPS beacon doesn´t confuse with ghost signal indication!
External interference and distance recommendations All beacons are very sensitive to electrical and magnetic sources of interference. Due to this, all manufacturers recommend keeping a minimum distance from electronic, magnetic and metallic sources of interference (mobile phone, radio, keys, magnetic closures, etc.): Minimum distance in send mode: 20 cm | Minimum distance in search mode: 50 cm
Beacons with iPROBE-support* get automatically deactivated when probing with the electronic probe PIEPS iPROBE. This prevents signal overlaps and the next-strongest signal is automatically shown on the display of the receiving beacon. Maximum support in multiple burials!
The PIEPS MICRO BT sensor/button has the Auto-Revert Search-to-Send (AR) function. The device switches from search to send mode automatically if the device has recognized a burial (no motion).
The AR function is shown clearly on the display: the transmitting symbol alternates with AR.

The AR-function provides the following characteristics:
Beacon function SEARCH WARNING SEND
PIEPS MICRO BT sensor:
PIEPS MICRO BT button/RACE:
abort Turn device or press MARK button
START WARNING Setting 1 (60 s) 0:30 min Setting 2 (90 s) 1:00 min Setting 3 (120 s) 1:30 min
SWITCHING TO SEND 1:00 min 1:30 min 2:00 min
After the switching the PIEPS MICRO BT sensor transmits permanently with a warning signal till it is switched off. The PIEPS MICRO BT button/RACE can be switched into search-mode with the secured 2-button-confirmation.
Display indication Search-Display · Sound Search-sound · Manual

A buried person has the greatest chance of being rescued by an efficient companion rescue. In the event of an accident, the following applies: KEEP CALM, OBSERVE, ALERT, ACT WITH COORDINATION! (1) Keep calm & get an overview
(2) Make a brief emergency call
(4) Systematic digging (5) First Aid (6) Rescue

Result Accuracy Search Speed

Start searching in the primary search area for the initial signal detection as well as for visual/acoustic signals. The PIEPS beacon has a circular receiving range that allows a correct indication of direction and distance from the point of initial signal detection – a specific method such as turning/rotating is not necessary. All signals of the burials that are within the maximum receiving range are received simultaneously.
Walk the search strip width in the search area quickly. The recommended search strip width for the PIEPS beacon is 50 m. The display shows “no signal”.



One rescuer with skis for signal search
More rescuers for signal search d = search strip width
One rescuer by foot for signal search
one two three four or more
Vibra on initial signal detection The PIEPS beacon provides additional haptic support by vibration on initial signal detection. This lets rescuers focus on the visual surface search during the signal search.

Follow the directional arrow quickly and check for a decreasing distance reading. Change the search direction by 180° in case of an increasing distance reading.




Turn right NOTICE Work calmly and with concentration in search mode. Avoid hasty movements!
From a distance of 5 m, the search speed should be notably reduced (50 cm/s). At the same time, start working close to the surface of the snow. To prevent confusion during the fine search, the direction indication disappears below a distance of 2 m. Reduce the search speed again and find, by cross-like movements, the position of the lowest distance reading. A dynamic acoustic signal output supports the fine search: the closer the faster.


Do an accurate direction adjustment before the direction arrow disappears! You are then moving to the transmitting beacon in best coupling position and save time during the cross-like movements.
Move your beacon at a slow, steady speed of about 10 cm/s, keep it leveled close to the surface and do not rotate your device. Search along the Y axis, determine the lowest distance value, then follow along the X axis. Always move past the point of the lowest distance to verify the distance tendency. Mark the point of the lowest distance reading and start pinpointing.
Turn left · Move straight ahead


Begin at the point of the lowest distance indicated. Always probe perpendicular to the surface. Use your lower hand as a “probe guide” to ensure the probe follows a steady path. Follow a proven system until you have a hit. Communicate a hit clearly to companions. Leave the probe stuck for shoveling guidance.
A multiple burial is indicated clearly on the display by the number of small human figures (2G, 2H). Marking is possible from a distance reading of 5 m and is indicated by the MARK symbol (2E). Press the button MARK (1A) briefly to “hide” the localized transmitter. A successful flagging is confirmed by a frame around the human figure (2J). The display then indicates the direction/distance to the next strongest signal inside the receiving range. If there are no further signals within the receiving range the display indicates “no signal”.

Continuous wave indication | old-device-indication Old analog transceivers are transmitting a continuous wave in addition to the pulse signal. To keep an impact at a minimum, it is recommended to step a few meters away after marking such a transmitter.


Signal without continuous wave Signal with continuous wave
The PIEPS beacon identifies a continuous wave and supports visually by flashing human figures.
prior to marking · after marking

Bluetooth and the PIEPS APP allow a straightforward device management (e.g. software update, device configuration) and additionally provide a handy training mode. Get the PIEPS APP (Android Play Store, iOS App Store), connect your PIEPS beacon and take advantage of all features!
To activate Bluetooth (2A), press the button MARK (1A) while switching on the beacon. As soon as the Bluetooth symbol is shown on the display, the MARK button can be released. The Bluetooth-mode is confirmed with an acoustic (2x Pieps-tone) and haptic (2x Vibra) signal. To enable Bluetooth, press the button MARK (1A) while switching on the beacon.
Bluetooth enabled Connection to mobile device established

Admin Lock ✓ ✓ Battery type (Alkaline/Lithium) ✓ ✓ Auto-Search-to-Send Timeout (60 s/90 s/120 s) ✓ ✓ Group check ON/OFF ✓ ✓ Group check Pro-Mode ON/OFF ✓ ✓ Send-Vibra ON/OFF ✓ ✓ Group check extended ON/OFF ✓ ✓ iPROBE support ON/OFF ✓ ✓ Reset to factory defaults ✓ ✓ Further useful features of the PIEPS APP:

Error Description Measure No indication on the display Check the device for physical damage. Check the battery capacity, type and polarity (+,-). Replace the batteries. Take the device to your retailer. E0 High current This error disappears after the self-check.
Take the device to your retailer.
E1 System configuration This error remains on the display. The device is not serviceable.
Take the device to your retailer.
Repeat the self-check in an area free from interference (outdoors) and check for electronic, magnetic and metallic sources of interference. In case of a permanent error take the device to your retailer. E5 Processor This error remains on the display. The device is not serviceable.
Transmitter or receiver or amplifier The error disappears after the self-check. The device has limited functionality in send or search mode.
Take the device to your retailer.
E6 Distance and/or direction indicator This error disappears after the self-check. The device has limited functionality regarding the distance and/or direction indication.
Take the device to your retailer.
E7 Proximity sensor The error remains in the additional display (2B). In this case, automatic SendSearch switching is not possible; the switching must be performed manually.
Repeat the self-check and ensure that the sensor area is not covered during the self-check. Manual SendSearch switching is performed by pressing the MARK button for 3 seconds. Take the device to your retailer. Automatic SendSearch switching does not take place.
Ensure that the sensor is not covered. Check the display glass and especially the sensor area for soiling or deposits (large snowflakes), clean the display glass as necessary. E8 Accelerometer This error disappears after the self-check. The device has limited functionality: Auto- Search-to-Send is not possible. Group check pro-mode is not possible.
Take the device to your retailer.
E9 Bluetooth Bluetooth activation and/or connection not possible. The avalanche beacon function is working. Is not checked during the self-check, occurs only during Bluetooth activation.
Retry to activate the Bluetooth mode. In case of a permanent error take the device to your retailer.

Change the batteries as soon as the battery capacity indication (2C) shows an empty battery. Always change all three batteries at once! To do so, open the battery compartment (1D, 1F) and be sure to insert the new batteries the right way around. For battery disposal, follow the applicable regulations in your country.

PIEPS MICRO BT sensor 200 h 350 h PIEPS MICRO BT button/RACE 200 h 350 h

3/3 full 100% - 66% (h SEND) ✓ 2/3 full 66% - 33% (h SEND) ✓ 1/3 full 33% (h SEND) - 20 h SEND ✓
empty 20 h SEND (+10° C, 50° F) + 1 h SEARCH (-10° C, 14° F)
empty, blinking Final reserve, device can shut down at any time
Use a damp cloth without cleaning agent to clean the device.

Store the device in a dry room at room temperature.

Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| E0 | High current This error disappears after the self-check. | p.22 | |
| E1 | System configuration This error remains on the display. The device is not serviceable. | p.22 | |
| E2 E3 E4 | Transmitter or receiver or amplifier The error disappears after the self-check. The device has limited functionality in send or search mode. | p.22 | |
| E5 | Processor This error remains on the display. The device is not serviceable. | p.22 | |
| E6 | Distance and/or direction indicator This error disappears after the self-check. The device has limited functionality regarding the distance and/or direction indication. | p.22 | |
| E7 | Proximity sensor The error remains in the additional display (2B). In this case, automatic SendSearch switching is not possible; the switching must be performed manually. | p.22 | |
| E8 | Accelerometer This error disappears after the self-check. The device has limited functionality: Auto- Search-to-Send is not possible. Group check pro-mode is not possible. | p.22 | |
| E9 | Bluetooth Bluetooth activation and/or connection not possible. The avalanche beacon function is working. Is not checked during the self-check, occurs only during Bluetooth activation. | p.22 |