Thank you for purchasing a Honeywell Dehumidifier. This User Manual is intended to provide you with important information needed to set up, operate, maintain and troubleshoot this product.
WARNING -- READ AND SAVE THESE INSTRUCTIONS BEFORE USING THIS PRODUCT. The use of electrical products may create hazards that include, but are not limited to injury, fire, electrical shock. Failure to follow these instructions may damage and/ or impair its operation and void the warranty. In case there is any inconsistency or conflict between the English version and any other language version of the content of this material, the English version shall prevail.
When using electrical appliances, basic safety precautions should always be followed:
DO NOT touch the dehumidifier or the electrical plug with wet hands. Check the household voltage to ensure it matches the appliance's specification. Before operating, remove all packaging material and check for any damage that may have occurred during shipping. DO NOT operate any product with a damaged cord or plug. DO NOT use an extension cord with this appliance. DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from areas where it may be tripped over. Always unplug the dehumidifier before emptying the water tank. The water collected in the tank must be discarded. The water should never be used for drinking. Always unplug the dehumidifier and remove the water from the water tank before cleaning, servicing or relocating the unit. Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only, never pull the cord. This appliance has been manufactured for use in domestic environments and must not be used for other purposes. DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are used or stored. This dehumidifier is designed for indoor residential applications only. It should not be used for commercial or industrial applications. DO NOT attempt to repair or adjust any electrical or mechanical functions of the dehumidifier, as this may cause danger and void the warranty. DO NOT cover the air inlet or outlet on the appliance as this may cause the unit to fail. DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause electrical shock or fire.

DO NOT let children play with this appliance, packaging or included plastic bag. If the unit is damaged or it malfunctions, do not continue to operate it. Unplug the product from the electrical outlet. Refer to the troubleshooting section and contact the customer support
center. Always place the dehumidifier on a leveled floor. Never install the product near a bathtub or any water container. Store in a dry area, away from direct sunlight, when not in use. This appliance and its packaging materials are not intended for use by persons (including children or elderly) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning the use of the appliance by a person responsible for their safety. Always grip the top handle and keep the unit upright when transporting from room to room – DO NOT tilt the product on its side or upside-down. If the dehumidifier was transported tilted on its side, you must position it upright again and wait at least 4 hours before using it. WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid state speed control device.

When the dehumidifier is switched ON, a fan pulls moisture-laden air into the dehumidifier where it passes through dehumidifying coils inside the unit. These coils condense moisture from the air and collect it in the water tank. The dry air is then exhausted from the dehumidifier. The air flows
through the air vents of the dehumidifier into the room as dry, warm air.
Before using the dehumidifier, place the unit UPRIGHT for at least 1 hour before use to allow the refrigerant to stabilize. If the unit was tilted on its side or upside-down during transportation, set the unit upright for 4 hours before use.
For optimal efficiency, the dehumidifier must be operated in an enclosed area. Keep all doors, windows and other outside entrances to the room closed.
• · •

Place the dehumidifier in an area where the temperature will not drop below 41°F (5°C)
Place the dehumidifier at least 17.7 inches (45 cm) away from other objects (e.g. curtains or
furniture) that may restrict airflow from the back or through the air vents of the unit.
The dehumidifier must be positioned on a level floor.

IMPORTANT: The effectiveness of the dehumidifier can be influenced by different factors. One factor is the rate at which new, moisture-laden air enters the room and the amount of air circulating in and out of the area to be dehumidified. For example, if a door to a basement is constantly opened, letting new, moisture-laden air into the room, dehumidification will take longer than if the door was kept closed. If the dehumidifier is in a room with a storage closet or cabinets, it will have little or no effect in drying the inside of the storage closet or cabinets unless there is adequate circulation of air in and out of these spaces. To dehumidify these spaces, open the storage door or cabinet doors to allow air circulation. You may find that installing a second dehumidifier may be required for larger enclosed areas.
• · • · •

This Dehumidifier is packaged with a colored or transparent tape to secure some parts during transportation. Remove the colored or transparent packaging tape from the unit.
There is a Foam Float inside the water tank that senses the water level to automatically stop dehumidification when the water tank is full. Make sure the Foam Float is positioned correctly inside the water tank by ensuring it lies level with the top edge of the water tank.
DO NOT REMOVE THIS FOAM FLOAT.




* THIS IS ONLY FOR MODEL TP70P / TP70PN WITH BUILT-IN DRAIN PUMP

Once you have removed the cord winder accessories from the water tank - follow the steps below.

(1) (8) (9) (10^)

(6) (4) (3) (2) (3) (5) (7) (11*)
^THIS IS ONLY FOR MODEL TP30A / TP50A / TP70A WITH WIFI SMART FEATURES
http://honeywellaircomfort.com/TP-SmartApp-Manual.pdf
11*) Auto Drain Pump Mode

POWER CONTROL Press to switch the dehumidifier ON or OFF.
When the unit is switched ON, the Display Screen shows the current humidity percentage. Press or to select your preferred humidity level. The humidity is adjusted in increments of 5% by pressing or . The adjustable Relative Humidity (RH) range is between 30% RH to 90% RH. Ten seconds after setting the preferred humidity setting, the display will revert back to displaying the current humidity.
Recommended Settings: It is recommended to leave the unit running at 30% humidity at High Fan Speed during the first 2 to 3 days until damp odors are removed. After a few days when the Relative Humidity has been reduced to a more comfortable level, press or to choose a higher RH% that maintains a comfortable humidity level thereafter. A recommended healthy humidity level is between 40% and 50%.
CONTINUOUS MODE To activate the Continuous Mode, press the button on the Display Screen until appears. The indicator light will be illuminated. The unit will run continuously.
WATER TANK FULL ALERT When the Water Tank is full, the indicator will be illuminated. The unit will beep for 3 seconds. The compressor will shut off, and the fan will stop for a few minutes. To switch off the indicator light, empty the water tank and when replacing it ensure the tank is secured properly in place.

TIMER CONTROL The dehumidifier can be set to automatically switch ON or OFF for a selected period of time (between 0.5-24 hour intervals). The Timer hours selection is displayed on the Display Screen.
Auto-Off Timer: While the unit is running, press , the timer indicator light will flash, press or to select the number of hours (0.5-24 hours) you want the unit to run before it switches off. In 5 seconds without the operation, the Timer start function, the timer indicator light is illuminated. Timer must be set again after each use.
Auto-On Timer: When unit is in Standby Mode, press , the timer indicator light will flash, press or to select the number of hours (0.5-24 hours) until you want the unit to automatically start running. In 5 seconds without the operation, the Timer start function, the timer indicator light is illuminated. The previous fan speed and humidity setting will be maintained. The unit will turn on and continue running until the water tank is full (unless the unit is set up for continuous draining) or until you switch it off manually. Timer must be set again after each use.
FAN SPEED CONTROL There are two fan speeds - High and Low. When, the indicator light is illuminated, the unit is operating on High speed. When the indicator light is off, and the unit is on - the unit is operating on Low speed.
FILTER ALERT When the Filter Alert Light is ON, it is time to clean the filter. Switch the unit OFF and carefully remove the filter from the unit and clean. Replace the filter and switch ON the unit.
The Filter Alert Light should not be illuminated until the filter requires cleaning again. The frequency of filter cleaning depends on room environment conditions. Some rooms may require changing more frequently than others.

SLEEP MODE The LED display brightness will be reduced when the unit is in Sleep Mode. Press the to activate the Sleep Mode. When Sleep Mode is activated the indicator light will be illuminated. There is a one-minute window period in which you can adjust the settings such as humidity and fan speed. After one minute has lapsed, the top display will shut off, except the indicator light. Press any button to deactivate Sleep Mode.
WI-FI MODE^ When the Smart Dehumidifier is connected to the wifi function, the indicator light will be illuminated.
^THIS IS ONLY FOR MODEL TP30A / TP50A / TP70A WITH WI-FI SMART FEATURES
AUTO DRAIN PUMP MODE* The Auto Drain Pump function helps to remove condensation vertically and horizontally. Press the to activate the Pump function, the indicator light will be illuminated.
*THIS IS ONLY FOR MODEL TP70P / TP70PN WITH BUILT-IN DRAIN PUMP
Frost may build up on the internal coils of the unit. When there is frost build up, the internal compressor will turn off and the fan will continue to run until the frost has melted. Once the internal
coils have defrosted and dried, the compressor or fan will automatically restart and dehumidifying will resume.

The condensed water can be collected directly into the water tank. When the water tank is full, the dehumidifier will automatically shut OFF and the indicator will illuminate on the control panel followed by a beeping sound.
Locate the water tank at the front of the dehumidifier. Gently pull the water tank out.

Grip the handle inside the water tank and carry the water tank to a sink to empty.
Replace the empty water tank back into the front of the dehumidifier. Please make sure that the tank is properly positioned. The safety feature ensures that any misalignment of the tank and the unit will prevent the unit from turning back on.

DO NOT REMOVE THIS FOAM FLOAT.
Foam Float

A continuous water drain tube is included with this unit. To activate the continuous water draining function, you will require a suitable water drain (e.g. sink or drain hole at floor level) near the dehumidifier.
Drain Tube 3.28 ft. (1 m) Continuous Water Drain Cap
Locate the drain outlet at the back of the unit. Unscrew and remove the Direct Drain Cap. Insert and screw the Continuous Water Drain Tube into the Direct Drain Outlet.
Continuous Water Drain Tube
Continuous Water · Direct Drain Cap


If there are leaks, the Continuous Water Drain Tube and Cap may have loosened and may not be connected properly. Disconnect, replace and tighten again.
Position the other end of the Continuous Water Drain Tube in the sink or drain. Make sure the tube is not bent or kinked which might stop the water flow. Make sure the tube is secured over the drain and will not fall out of place causing unwanted water spillage.

*THIS IS ONLY FOR MODEL TP70P / TP70PN WITH BUILT-IN DRAIN PUMP
The Auto Drain Pump is available if you want to use the continuous drain function, but the drain is further away, or located above the dehumidifier. The Auto Drain Pump Tube can be attached to the Direct Drain Outlet located on the back side of the dehumidifier. When the water level in the water tank reaches a certain level, the drain pump will automatically pump the water out of the tank to the drain. This allows you to drain water condensation vertically or horizontally, even if the drain is located above the dehumidifier.
Auto Drain Pump Tube
16.4 ft. (5 m)
Auto Drain Pump Cap
Locate the drain outlet at the back of the unit. Unscrew and remove the Direct Drain Cap. Insert and screw the Auto Drain Pump Tube into the Direct Drain Outlet.
Auto Drain Pump Tube
Direct Drain Cap

If there are leaks, the Auto Drain Pump Tube and Auto Drain Pump Cap may have loosened and may not be connected properly. Disconnect, replace and tighten again.
To activate the Pump function, press the indicator. Once on, the indicator light will be illuminated.
Place the other end of the tube into the sink or drain. The water can be pumped up to 16.4 ft (5 m) vertically or horizontally.
*Auto Drain Pump Tube is included in Dehumidifier models with Auto Drain Pump feature only.

Dust Filter Maintenance: The Dust Filter located at the back of the unit helps to remove dust particles from the air. A dirty filter clogged by dust particles can reduce the efficiency of the dehumidifier. For optimum dehumidification, it is recommended to clean the dust filter every 2 weeks:
Switch off and unplug the dehumidifier from the electrical outlet.
Carefully pull out the dust filter from the dehumidifier.
Rinse the dust filter under running water, or vacuum away the dust with a vacuum cleaner.
After cleaning the dust filter, dry in a cool, shaded place, then carefully reinstall into the unit.
End of Season Storage & Maintenance:
If the appliance will not be used for an extended period of time:
Switch OFF the unit and unplug from the electrical power outlet. Empty the water tank and let it dry. If your dehumidifier is connected to the continuous drain hose, you must disconnect the hose, dry and then replace the drain cap back into the drain outlet. Remove the air filter and clean with water. Let the air filter dry and reinstall back into the unit. Make sure all parts of the dehumidifier and accessories are dry before storage. Cover the dehumidifier with a cloth/ plastic bag before storage, to protect the surface from dust and scratches. It is recommended to coil the power cord and store it off the floor to ensure it is protected from bends and kinks. Store the unit upright in a dry location, away from direct sunlight.

The following troubleshooting guide addresses the most common problems. If problems persist, call customer service.
No electricity. Check for power.
The power cord is not properly plugged in. Remove and reconnect the power cord.
Dehumidifier does not start
The safety switch activated on the electrical plug.
Reset the safety switch and wait for 3 minutes to pass. Contact customer service if problem persists.
The water tank is not in the correct position.
Position the water tank correctly into the unit. Unit will not operate until the water tank is secure in place.
The humidity level setting is too high. Decrease the humidity level setting.
A door or window is open, letting in new moisture.
Make sure all windows or doors to the outside are closed and tightly sealed.
There are other sources of humidity in the room (e.g. boiling water in pot).
Switch on the dehumidifier when these sources are not present.
Unit runs but the humidity level does not decrease
The dehumidifier is designed to operate between 41°F (5°C) and 89°F (32°C). Moisture removal is greatly reduced if room temperatures exceed this temperature range.
The temperature in the room is too low.
The dust filter is dirty/ blocked. Clean the dust filter.
Air outlet or intake is blocked. Remove blockage.

Unit runs but the humidity level does not decrease
Insufficient time for the dehumidifier to remove moisture.
After initial installation, allow 24 hours to maintain desired dryness.
Area to be dehumidified is too large.
The capacity of your dehumidifier may not be adequate for the room it is used in. It is recommended to add an extra dehumidifier for large areas.
Dehumidifier runs constantly/ does not stop
A door or window is open, letting in new moisture.
Make sure all windows or doors to the outside are closed and tightly sealed.
The water tank is full. Empty the water tank.
Water Tank Full is illuminated and the unit is beeping
The water tank is not in the correct position.
Position the water tank correctly into the unit. Unit will not operate until the water tank is secure in place.
The unit is blowing cold air out of the top vent
The purpose of the top air vent is to distribute air into the room.
The temperature of the air from the vent depends on the room environment and other factors. It can fluctuate and this is normal. No action required.
Dehumidifier has been recently turned on in low room temperatures (usually below 41°F (5°C)).
Frost appears on the coils
This is normal. Frost will disappear in an hour or so after the dehumidifier is switched OFF.
Connected the continuous drain but the water condensation is not draining out the tube
Some floors may have an uneven surface which may affect the continuous drainage function
Raise the front of the Dehumidifier ½ to 1 inch (1.27 cm to 2.54 cm) from the floor. The water condensation will drain out the back hose and not into the bucket.

Check the connections between the hose and the drain outlet on the unit. See Continuous Water Drainage section.
The garden hose/ drain hose may be loose.
Water on the floor
You intended to use the water tank to collect water but the continuous drain hose is still connected.
Disconnect the hose and replace the rubber stopper and drain cap if using the water tank to collect water. See Continuous Water Drainage section.
Fan is working. Wind from the fan can create sounds during operation. This is a normal sound.
There is a sound when the compressor turns on. The compressor will activate periodically based on humidity settings. This is normal.
Compressor is working.
Noise

This only appears for model TP70P / TP70PN with Built-in Drain Pump. Position the water tank correctly into the unit. Unit will not operate until the water tank is secure in place.
P1 Water tank pull out
EH Humidity sensor failure Please contact the service center.
E1 / E2 Temperature sensor failure Please contact the service center.
If E3 appears, Please the check the ambient temperature range whether below 89.6°F (32°C).
If the ambient temperature over 89.6°F (32°C) place the unit below 86°F (30°C) for 2 hours before running the Dehumidifier again.
If the E3 appears again in 2 hours, please contact the service center.
E3 Gas leakage

This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum 20 cm between the radiator and your body. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC.
This Class B digital apparatus complies with Canadian ICES-003. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. The antenna (or antennas) must be installed so as to maintain at all times a distance minimum of at least 20 cm between the radiation source (antenna) and any individual. This device may not be installed or used in conjunction with any other antenna or transmitter.
Electrical products should be properly disposed of. Please recycle where facilities exist. Check with your local authority or retailer for recycling.
ENERGY STAR® qualified units remove moisture with less energy than conventional dehumidifiers.

Thank you for purchasing a Honeywell Smart Dehumidifier. This user manual is intended to provide you with important information needed to set up, operate, maintain and troubleshoot this product.
The Smart Dehumidifier has added features to allow you to operate the dehumidifier remotely using a smart device, and to use voice commands through an Amazon Echo device, to control the unit.
Set up the Honeywell Air Comfort App on your smart phone or tablet to connect the Honeywell Smart Dehumidifier for WiFi and Voice control. IMPORTANT: A 2.4 GHz Wi-Fi network is required for proper connection and operation between the Dehumidifier and the App.






a. Open the app. b. Tap Register.
a. Enter your email*
a. Enter the verification
code. b. The verification code
(2A) or mobile phone number (2B). b. Tap Get Verification
should be recieved & entered within 60 seconds. If time is exceeded, go back and get another code.
Code.



a. Set the password. b. Tap Done.
a. Tap Create Family.
a. Set the Family Name
and Family Location. b. Mark the location of
the dehumidifier. c. Tap Done.
* The user will receive a verification email from “[email protected]” with contact name “Honeywell Air Comfort” and subject title “Registration Verification Code”. If email is not received in your inbox, check your junk or spam folders. If you didn’t receive a verification email after 60 seconds, click the resend button.

The Smart Dehumidifier has two different setup modes:
CF (Quick Connection): The CF mode is a quick and simple way to set the unit up.
AP (Access Point): The AP mode uses a direct local Wi-Fi connection between your phone and the dehumidifier to upload the network details.
Before starting the setup, please ensure that your Smart Dehumidifier is plugged in and turned OFF (in Standby Mode) for the connection type you are attempting. The display on the Dehumidifier will confirm the current connection mode during setup.


a. Tap Add Device.
a. Tap Dehum icon.


a. Switch on the dehumidifier. b. On the Dehumidifier, Press the button 6 times until displays on the unit. c. Tap Next.



a. Choose the Wi-Fi
a. Tap Done. a. Wait until the connection
network. b. Enter the Wi-Fi password. c. Tap Confirm.
is completed.




a. Tap Dehum icon.
a. Tap AP Mode in the top
a. Tap Add Device.
right corner.


a. Switch on the dehumidifier. b. On the Dehumidifier, press the button 6 times until displays on the unit. c. Tap Next.




a. Tap Go to Connect. a. Choose the Wi-Fi
a. Tap the Smartlife-XXXX
network. b. Enter the Wi-Fi
network (Wi-Fi board number). b. Once connected, press
password. c. Tap Confirm.
the home/back button on your device and go back to the Honeywell Air Comfort App.


a. Wait until the
a. Tap Done.
connection is completed.


- Dry: 0-40%RH - Comfortable: 40-70%RH - Moist: above 70%RH c. Outdoor Air Pressure d. Outdoor Wind Speed
a. Family/User
Management b. Message Center c. Help Center d. Settings
- Voice ON/OFF - Push Notifications ON/OFF - About - Clear Cache - Log Out

Setting the Family (User) Name
Setting the Family Location
John Smith john.smith@gma
Adding a Family (User) member



a. Tap Dehumidifier.
a. Tap to switch the dehumidifier on/off.

Go back to main screen
(Voice Activated Control) e. Share Device f. Create Group g. Device Information h. Feedback i. Add to Home Screen j. Check for Firmware
Upgrade k. Remove Device l. Restore to Factory
Defaults Current humidity level
Humidity down button Humidity up button
Fan speed button Timer set button
Dehumidifier on/off · Pre-set humidity level


a. Tap fan speed button. b. Select Low or High fan speed.

Select for unit to turn OFF after unit completes selected time period.
Select for unit to turn ON after selected time period of being idle ends.
a. Tap Timer set button. b. Tap Add Timer. c. Set the timer(s). d. When the timer is set, tap Save.

The Scenario feature allows you to set up multiple Dehumidifiers under one Scenario and control them on one dashboard as needed. When you click on the Scenario, all Dehumidi fiers will switch ON at the same time using previous settings.
E.g.: If you had set up a Dehumidifier in the Living Room and one in the Basement, you can create a “Scenario 1” to switch both dehumidifiers on at the same time.



a. Tap Smart control
a. Tap Edit Name to set
a. Select the Enable or
button. b. Tap Add Scenario.
the name of the scenario. b. Tap the background
Disable Automation. Tap . b. Select the Time-Lapse
to set the background image of the scenario. c. Tap Add Action to add
of the action. Tap . c. Select the Device and
the action (on/off). Tap . d. Tap Switch. Select the
action of the scenario.
action for the device to perform (on/off). e. Tap Save and then
Next. f. Tap Save.

The Automation Scenario feature allows you to set up multiple dehumidifiers under one Scenario and it will automatically activate those dehumidifiers when there is a change in outdoor environment conditions.
Pre-Set Outdoor Humidity Conditions:
When a change in outdoor condition is met, the pre-set Automation Scenario will switch ON or OFF all Dehumidifiers set up in that Automation Scenario.
E.g.: If you had set up a Dehumidifier in the Living Room and one in the Basement, you can create an “Automation Scenario 1” to switch both dehumidifiers on at the same time when outdoor humidity changes from “Comfortable” to “Moist”. When the outdoor humidity changes to “Moist” level , the dehumidifiers will automatically switch ON using previous settings. The Dehumidifiers will continue running until internal room humidity reaches previous desired humidity settings.


a. Tap Smart control button. b. Tap Automation. c. Tap Add Automation
a. Tap Edit Name to set the name
of the automation scenario. b. Tap the background to set the
Scenario.
background image of the automation scenario. c. Tap Add Condition to add the
condition of the automation scenario activation.



a. Tap Device. b. Tap Dehumidifier.
a. Select function(s) for the
dehumidifier to perform, when the automation scenario condition(s) is/are met. b. Tap Next.


a. Tap Add Action to set the
a. Tap Effective Period
action to be performed when the automation scenario condition(s) is/are met. b. Tap Next.
to select when the automation scenario should activate. b. Tap Next. c. Tap Save.

Connecting to an Amazon Echo Device: NOTE: Ensure your Amazon Echo device is switched on and connected to the Wi-Fi
network.
a. Open the "Amazon Alexa" app on your smart device.
b. Tap and then Skills & Games.
c. Tap and type "Honeywell Air Comfort". Tap the Honeywell Air Comfort skill.
d. Tap Enable To Use button.
e. Enter your Honeywell Air Comfort App login and password.
f. Tap Link Now and then tap Authorize.
g. Tap Done.
h. Tap Discover Device. Choose "Dehumidifier".
i. Tap Sst Up Device Choose a group for the device or tap Skip.
j. Choose "Dehumidifier".
k. Tap Done.
Switching On/Off:
Say: "Alexa, turn on/off dehumidifier".

Mobile smart device’s Wi-Fi is switched off.
Switch on the mobile phone’s Wi-Fi.
Install a Wi-Fi extender (not included).
Unable to register/login to an account.
Wi-Fi signal is too weak.
Move the smart dehumidifier closer to the Wi-Fi router.
Dehumidifier is not connected to the the electrical outlet.
Connect the dehumidifier to the socket-outlet.
Install a Wi-Fi extender (not included).
Wi-Fi signal is too weak.
Move the smart dehumidifier closer to the Wi-Fi router.
The default pairing mode does not work.
Pair the dehumidifier in AP mode (see section on “Connecting in AP Mode”)
Wi-Fi connection frequency is incorrect.
Select a 2.4 GHz Wi-Fi network
Dehumidifier cannot pair with the Honeywell Air Comfort App.
Wi-Fi password is incorrect. Use a correct Wi-Fi password.
Wi-Fi network is invisible. Set the Wi-Fi network to visible.
Set the Wi-Fi name to use alphanumerical characters and numbers only.
Wi-Fi name uses foreign characters.
Set the encryption method of the router’s wireless setting to “WPA2-PSK” and the authentication type to “AES”, or both are set as automatic. Note: “802.11n only” is not allowed in wireless mode.
The encryption method of the router’s wireless setting is wrong.

Turn off the Wi-Fi functions of some of the connected devices.
The number of connected devices reached the limit of the router.
Re-configure the router.
Dehumidifier cannot pair with the Honeywell Air Comfort App. (Continued)
Remove the device from the MAC address filter on the router.
The router has enabled the wireless MAC address filter.
Ensure the device is not prohibited by the router to connect to the network.

^ Canada Customer Support service available for models sold in Canada only. ^ Le Service Client Canadien est disponible uniquement pour les modèles vendus sur le territoire Canadien. ^ Servicio de Atención A Clientes en Canadá disponible solo para modelos vendidos en Canadá.
Made in China © 2020 JMATEK Limited. All rights reserved. The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties with respect to this product. This product is manufactured by Airtek Int'l Corp. Ltd. (subsidiary of JMATEK Ltd.).
JMATEK North America LLC Mahwah, New Jersey 07495 USA Email: usinfo@jmatek.com Web: www.jmatek.com
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Dehumidifier does not start | No electricity. | Check for power. | p.19 |
| Dehumidifier does not start | The power cord is not properly plugged in. | Remove and reconnect the power cord. | p.19 |
| Dehumidifier does not start | The safety switch activated on the electrical plug. | Reset the safety switch and wait for 3 minutes to pass. Contact customer service if problem persists. | p.19 |
| Dehumidifier does not start | The water tank is not in the correct position. | Position the water tank correctly into the unit. Unit will not operate until the water tank is secure in place. | p.19 |
| Unit runs but the humidity level does not decrease | The humidity level setting is too high. | Decrease the humidity level setting. | p.19 |
| Unit runs but the humidity level does not decrease | A door or window is open, letting in new moisture. | Make sure all windows or doors to the outside are closed and tightly sealed. | p.19 |
| Unit runs but the humidity level does not decrease | There are other sources of humidity in the room (e.g. boiling water in pot). | Switch on the dehumidifier when these sources are not present. | p.19 |
| Unit runs but the humidity level does not decrease | The temperature in the room is too low. | The dehumidifier is designed to operate between 41°F (5°C) and 89°F (32°C). Moisture removal is greatly reduced if room temperatures exceed this temperature range. | p.19 |
| Unit runs but the humidity level does not decrease | The dust filter is dirty/ blocked. | Clean the dust filter. | p.19 |
| Unit runs but the humidity level does not decrease | Air outlet or intake is blocked. | Remove blockage. | p.19 |
| Unit runs but the humidity level does not decrease | Insufficient time for the dehumidifier to remove moisture. | After initial installation, allow 24 hours to maintain desired dryness. | p.20 |
| Dehumidifier runs constantly/ does not stop | Area to be dehumidified is too large. | The capacity of your dehumidifier may not be adequate for the room it is used in. It is recommended to add an extra dehumidifier for large areas. | p.20 |
| Dehumidifier runs constantly/ does not stop | A door or window is open, letting in new moisture. | Make sure all windows or doors to the outside are closed and tightly sealed. | p.20 |
| Water Tank Full is illuminated and the unit is beeping | The water tank is full. | Empty the water tank. | p.20 |
| Water Tank Full is illuminated and the unit is beeping | The water tank is not in the correct position. | Position the water tank correctly into the unit. Unit will not operate until the water tank is secure in place. | p.20 |
| The unit is blowing cold air out of the top vent | The purpose of the top air vent is to distribute air into the room. | The temperature of the air from the vent depends on the room environment and other factors. It can fluctuate and this is normal. No action required. | p.20 |
| Frost appears on the coils | Dehumidifier has been recently turned on in low room temperatures (usually below 41°F (5°C)). | This is normal. Frost will disappear in an hour or so after the dehumidifier is switched OFF. | p.20 |
| Connected the continuous drain but the water condensation is not draining out the tube | Some floors may have an uneven surface which may affect the continuous drainage function | Raise the front of the Dehumidifier ½ to 1 inch (1.27 cm to 2.54 cm) from the floor. The water condensation will drain out the back hose and not into the bucket. | p.20 |
| Water on the floor | The garden hose/ drain hose may be loose. | Check the connections between the hose and the drain outlet on the unit. See Continuous Water Drainage section. | p.21 |
| Water on the floor | You intended to use the water tank to collect water but the continuous drain hose is still connected. | Disconnect the hose and replace the rubber stopper and drain cap if using the water tank to collect water. See Continuous Water Drainage section. | p.21 |
| Noise | Fan is working. | Wind from the fan can create sounds during operation. This is a normal sound. | p.21 |
| Noise | Compressor is working. | There is a sound when the compressor turns on. The compressor will activate periodically based on humidity settings. This is normal. | p.21 |
| Unable to register/login to an account. | Mobile smart device’s Wi-Fi is switched off. | Switch on the mobile phone’s Wi-Fi. | p.37 |
| Unable to register/login to an account. | Wi-Fi signal is too weak. | Install a Wi-Fi extender (not included). | p.37 |
| Unable to register/login to an account. | Move the smart dehumidifier closer to the Wi-Fi router. | p.37 | |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. | Dehumidifier is not connected to the the electrical outlet. | Connect the dehumidifier to the socket-outlet. | p.37 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. | Wi-Fi signal is too weak. | Install a Wi-Fi extender (not included). | p.37 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. | Move the smart dehumidifier closer to the Wi-Fi router. | p.37 | |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. | The default pairing mode does not work. | Pair the dehumidifier in AP mode (see section on “Connecting in AP Mode”) | p.37 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. | Wi-Fi connection frequency is incorrect. | Select a 2.4 GHz Wi-Fi network | p.37 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. | Wi-Fi password is incorrect. | Use a correct Wi-Fi password. | p.37 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. | Wi-Fi network is invisible. | Set the Wi-Fi network to visible. | p.37 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. | Wi-Fi name uses foreign characters. | Set the Wi-Fi name to use alphanumerical characters and numbers only. | p.37 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. | The encryption method of the router’s wireless setting is wrong. | Set the encryption method of the router’s wireless setting to “WPA2-PSK” and the authentication type to “AES”, or both are set as automatic. Note: “802.11n only” is not allowed in wireless mode. | p.37 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. (Continued) | The number of connected devices reached the limit of the router. | Turn off the Wi-Fi functions of some of the connected devices. | p.38 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. (Continued) | Re-configure the router. | p.38 | |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. (Continued) | The router has enabled the wireless MAC address filter. | Remove the device from the MAC address filter on the router. | p.38 |
| Dehumidifier cannot pair with the Honeywell Air Comfort App. (Continued) | Ensure the device is not prohibited by the router to connect to the network. | p.38 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.