


Full declaration available at www.eterna-lighting.co.uk
The light source is designed to last the lifetime of the luminaire.

The light source contained in this luminaire shall only be replaced by the manufacturer, service agent or a similar qualified person. CAUTION, RISK OF ELECTRIC SHOCK.
Sensor
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” effective August 2005—UK WEEE Regulations effective 2nd January 2007). Environment Agency Registered Producer: WEE/GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST - DO NOT DISPOSE WITH HOUSEHOLD WASTE.
Model: SDCSLEDCR / SDCSLEDWH LED Colour Temperature Selectable Ceiling/Wall Fitting With
Clean this fitting only with a soft dry cloth. Do not use any chemical or abrasive cleaners.
If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specific instructions regarding individual installations.
See website for more information on replacability and recycling

These instructions are provided as a guideline to assist you. PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
Visit our website: www.eterna-lighting.co.uk Made in China Issue 0821
Microwave Occupancy Sensor · LED Indication

This product is not intended to be used by children and persons with sensory, physical and/or mental impairments that would prevent them from using it safely.
Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
This determines the effective range of the motion detector and is set up by DIP switches at the sensor itself, refer to figure. Note that reducing the sensitivity will also narrow the detection range.
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specified in the current IEE wiring and building regulations.
This product must be installed by a competent person in accordance with the current building and IEE wiring regulations.
The following settings are available:
As the buyer, installer and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. Eterna Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
I - Detection Range 100% II - Detection Range 75% III - Detection Range 50% IV - Detection Range 25% V - Detection Range 10%
The ceiling / wall light incorporates a microwave sensing device which continuously scans the operating zone and immediately switches the light on when it detects movement in that area. This means that whenever movement is detected within the range of the sensor the light will switch on automatically and illuminate the area you have selected to light. While there is movement within range of the unit the light will remain on.
This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal domestic service. Using this fitting in any other environments may result in a shortened working life, for example where there is prolonged periods of use or higher than normal ambient temperatures such as lighting public or shared spaces or in nursing /care home facilities.

This determines the time the fitting remains at 100% level on motion detection and is set with DIP switches at the sensor itself, refer to figure. The walk test setting is useful when installing the fitting to establish correct operation and range.
A microwave sensor is an active motion detector emitting high-frequency electro-magnetic waves at 5.8GHz and receiving their echo. The sensor detects change in the echo pattern within its detection zone and the light is then triggered. The wave can pass through doors, glass and thin walls and will continually monitor the signal within the detection area.
Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB.
The following settings are available:
This product is suitable for use in living areas, Bathroom Zone 2 and outsides of zones.
I - 5s II - 30s III - 1 minute IV - 5 minutes V - 15 minutes VI - 30 minutes
If being fitted in a bathroom a 30mA RCD must be used.

Choose the location for your new fitting according to the conditions listed opposite.
DAYLIGHT SENSOR:
The Daylight Sensor options cannot be adjusted with this model. It is supplied preset to disabled and should not be amended.
The photocell is mounted inside the enclosure and lower daylight levels may not be detected through the diffuser. Select dip switch setting VI to disable the Photocell. On presence detection the fitting will run at 100% and then return to 10% corridor function after the pre-set Hold Time in daytime and night time operation.
This product is designed for permanent connection to fixed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).
This product is suitable for installation on surfaces with normal flammability e.g. wood, plasterboard and masonry. It is not suitable for use on highly flammable surfaces (e.g. polystyrene, textiles).
Refer to microwave sensor diagram on front page.
This luminaire has a step dim (corridor) function - operation is at 100% light level after last presence detection, reducing to 10% light output after installer selected time delay.
Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
The sensor is an active motion detector: it emits a high frequency electromagnetic wave 5.8GHz and receives its echo. The sensor detects the change in echo from movement in its detection zone. A microprocessor then triggers the switch light ON command. Detection is possible through doors, panels of glass and thin walls.
The chosen location of your new fitting should allow for the product to be securely mounted (e.g. to a ceiling joist) and safely connected to the mains supply (lighting circuit).
When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.
This product must be connected to earth termination.


Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.