Table of Contents 23 sections Multiple Sound Siren PSE04 A/B · Specification · Built-in high accuracy Temperature sensor · Overview · … ShowHide
Page 1 of the philo Multiple Sound Wireless Siren (PSE04) user manual — Built-in high accuracy Temperature sensor
Page 1 · click to enlarge
Page 1

Multiple Sound Siren PSE04 A/B

with other Z-WaveTM certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

philo Multiple Sound Wireless Siren (PSE04) — Multiple Sound Siren PSE04 A/B diagram (page 1)
Fig. 1 · Multiple Sound Siren PSE04 A/B
philo Multiple Sound Wireless Siren (PSE04) — Multiple Sound Siren PSE04 A/B diagram (page 1)
Fig. 2 · Multiple Sound Siren PSE04 A/B

The device adopt the Z-WaveTM 700 series chip, when your Z-WaveTM

network system is all made by Z-WaveTM 700 series devices. The network system will have the advantages as below.

  • Concurrent multi-channel support reduces external interference.
  • Better RF range, improve about 10 meters in indoor.
  • Support 100 Kbps transmit speed, speed up communication.
philo Multiple Sound Wireless Siren (PSE04) — Multiple Sound Siren PSE04 A/B diagram (page 1)
Fig. 3 · Multiple Sound Siren PSE04 A/B

Specification

philo Multiple Sound Wireless Siren (PSE04) — Specification diagram (page 1)
Fig. 4 · Specification
Rating6VDC (AA Battery *4), Max.300mA RF distanceMin. 40M indoor, 100M outdoor line of sight, RF Frequency868.40 MHz, 869.85 MHz(EU) 908.40 MHz, 916.00 MHz(US) 920.9MHz, 921.7MHz, 923.1MHz (TW/KR/Thai/SG) RF Maximum Power+10dBm (Peak), -10dBm (Average) Dimension170mm(L) X 58mm (W) X 30mm(H) Weight205g IP classification, LocationIPx4; Outdoor use Operation temperature-20 to 54° C Humidity85%RH max FCC IDRHHPSE04 Max. sound duration time110dB @30cm Multi sound6 Different tunes, Fire Alarm/Ambulance/Police/Alarm/Door chime/beep Temperature detector range-20 to 54° C

Built-in high accuracy Temperature sensor

The PSE04 is a wireless siren, based on Z-WaveTM technology. It is the Z-Wave PlusTM product, it support the security, OTA... Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.

This product can be included and operated in any Z-WaveTM network

Specifications are subject to change and improvement without notice.

Page 2 of the philo Multiple Sound Wireless Siren (PSE04) user manual — CAUTION
Page 2 · click to enlarge
Page 2

Overview

Func on

SirenTemperature sensor PSE04-AVV PSE04-BV
philo Multiple Sound Wireless Siren (PSE04) — Overview diagram (page 2)
Fig. 5 · Overview

Troubleshooting

SymptomCause of FailureRecommendation The device can not join to Z-Wave™ networkThe device may in a ZWave™ network.Exclude the device then include again.

For Instruction to http:// www.philio-tech.com

philo Multiple Sound Wireless Siren (PSE04) — Troubleshooting diagram (page 2)
Fig. 6 · Troubleshooting

CAUTION

– replacement of a battery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium battery types);

– disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion; – leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas; – a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas

The marking information is located at the bottom of the apparatus.

Page 3 of the philo Multiple Sound Wireless Siren (PSE04) user manual — Battery Installation
Page 3 · click to enlarge
Page 3

Battery Installation

philo Multiple Sound Wireless Siren (PSE04) — Battery Installation diagram (page 3)
Fig. 7 · Battery Installation

When the device report the low battery message. The user should replace the battery to new one. The battery type is AA, 1.5V

Please loosen the screw on the back cover to release the front cover

philo Multiple Sound Wireless Siren (PSE04) — Battery Installation diagram (page 3)
Fig. 8 · Battery Installation
philo Multiple Sound Wireless Siren (PSE04) — Battery Installation diagram (page 3)
Fig. 9 · Battery Installation
philo Multiple Sound Wireless Siren (PSE04) — Battery Installation diagram (page 3)
Fig. 10 · Battery Installation
Page 4 of the philo Multiple Sound Wireless Siren (PSE04) user manual — Adding to Z-Wave TM Network
Page 4 · click to enlarge
Page 4
SmartStart1. Product has a DSK string , you can key in first five digit to increment SmartStart process,or you can scan QR code. Ex:mydsk 10209-46687-52248-13629-04783-07465-15776-56519 2. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of minutes On in the network vicinity. *notice1:The QR code can be found on the device PSE04 or on the box. AssociationThis machine provides one groups of nodes. Each group can set 1 Nodes. Group 1 is called Lifeline the device will report : 1.Notification report 2.Sensor multilevel report 3.Device Reset Locally Notification 4.Battery Report 5.Indicator Report • Failed or success in including/excluding the node ID can be viewed from Z-WaveTM Controller.

Adding to Z-Wave TM Network

There is one tamper key on the device. The tamper key can add, remove, reset from Z-WaveTM network.

In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the add mode. And then power on the device. The device will auto start the SmartStart Inclusion mode.

Controller means “Remove” or “Exclusion”.

FunctionDescription Add1. Have Z-WaveTM Controller entered inclusion mode. 2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. 3. After add successful, the LED will light ON 1 second Remove1. Have Z-WaveTM Controller entered exclusion mode. 2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. 3. Node ID has been excluded. ResetNotice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON. 2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. 3. IDs are excluded and all settings will reset to factory default.
Page 5 of the philo Multiple Sound Wireless Siren (PSE04) user manual — Z-Wave TM Message Report
Page 5 · click to enlarge
Page 5

LED Light Indication

* Siren State Report: When the siren start playing or stop the alarm sounds, the device will unsolicited to send the “Notification Report” to the nodes in the group 1.

The LED light indicates the different modes of the PSE04

State TypeLED Indication Without Node IDUnder normal operation, when the PSE04 has not been allocated a node ID, the LED light will flash on and off alternately at 0.5 second intervals. By pressing the On/Off button, LED light will stop flashing temporarily. LearningSlow flashes once when learning is successful. Alarm TriggerAll LED flashes until trigger off.
Notification TypeSiren (0x0E) Event: Siren active (0x01) , Siren idle (0x00)

*Temperature Report: When the temperature differential over, the device will unsolicited to send the “Sensor Multilevel Report” to the nodes in the lifeline group. Sensor Type: Temperature (0x01)

*** Temperature differential report *** This function default is disable, to enable this function by setting the configuration NO.5 is greater than 0. In the default, is disable temperature differential report. If setting the configuration NO.5 to 1, when the temperature is changed to plus or minus one degree Celsius (1.8 degree Fahrenheit), the device will report temperature information to the nodes in the lifeline group. The device will measure the temperature in every 10 seconds. Notice 1: The PSE04 must stay awake for at least 2 seconds after communicating, so therefore the more communication, the power consumption fast, please pay attention to use configuration NO.5. Notice 2: This product cannot reflect outdoor temperature immediately because of the temperature sensor equipped inside rather than surface.

Z-Wave TM Message Report

In default the device will using Notification Report to represent the tamper trigger event.

* Tamper Report: When the tamper key is pressed over 5 seconds. The device will into the alarm state. In that state, if the tamper key be released, the device will unsolicited to send the report to the nodes in the group 1.

Notification TypeHome Security (0x07) Event: Tampering. Product covering removed (0x03)

Notification Report (V8) · Notification Report (V8)

Page 6 of the philo Multiple Sound Wireless Siren (PSE04) user manual — Over The Air (OTA) Firmware Update
Page 6 · click to enlarge
Page 6

change the tick interval, the default value is 30, if setting to 1, that means the minimum auto report interval will be one minute. And please notice if setting this value to zero, that means disable all of the timing report except the low battery detection.

*Play Sound: Using the BASIC_SET or Sound_Switch_Tone_Play_Set to play the siren, BASIC_SET or Sound_Switch_Tone_Play_Set with Value 0xFF, the Sound ID will be the same as the value which was set in Configuration No.7, 0x00 will stop to play.

Power Up Procedure

Basic Set (V2) or Sound Switch Tone Pley Set (V1)

ValueSound 0x00Stop Play 0x01Fire 0x02Ambulance 0x03Police 0x04Alarm 0x05Ding Dong 0x06Beep 0xFFSame as configuration NO.7 setting, or sound switch configuration setting.

*Battery Power Check

When the device power up, the device will detect the power level of the battery immediately. If the power level is too low, device will report low battery even every 30 minutes. Please change another new battery.

*Wake up beam

If a Z-Wave controller or other node in the network needs to communicate with a battery-powered device such as a door lock, the controller sends a special beam signal. The purpose of this beam is to wake up the FLiRS device. When the FLiRS device receives this beam, it immediately fully wakes up and then communicates with the controller or other Z-Wave device utilizing standard Z-Wave protocol commands. If the device does not hear a Beam it goes back to full sleep for another period until it partially awakes again and listens for a Beam.

* Timing Report: Beside the event triggered could report message, the device also support the timing unsolicited report of the status.

  • Battery level report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 6.
  • Low battery report: When the battery level is too low, every 30 minutes will report once.
  • Temperature report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 4.

Over The Air (OTA) Firmware Update

The device is supported with Z-Wave™ firmware update via OTA. 1. Set the Z-WaveTM Controller into the firmware update mode. 2. Choose the hex file to update the firmware. 3. Wait 10~15 minutes for completing the OTA process. 4. Result of OTA will show in Z-Wave™ Controller log.

Page 7 of the philo Multiple Sound Wireless Siren (PSE04) user manual — Power Up Procedure
Page 7 · click to enlarge
Page 7

During the OTA process, please DO NOT remove the power, otherwise, the firmware will be broken, and the device will be nonfunctional.

0Bit6: Reserve. 0Bit7: Reserve. 4Auto Report Temperature Time0x0C0~255The interval time for auto report the temperature. 5Temperature Differential Report0x000~255The temperature differential to report. 6Auto Report Battery Time0x0C0~255The interval time for auto report the battery level. 7Play Sound Control0x43AllControl play sound's level and which sound. 3Bit0~1: Play sound's level. Level 1~3, 0: Level 3. 0Bit2: Reserve. 0Bit3: Reserve. 4Bit4~7: Which sound id will play, when control form controller. Sound ID 1~6, 0: Disable.
philo Multiple Sound Wireless Siren (PSE04) — Power Up Procedure diagram (page 7)
Fig. 11 · Power Up Procedure

Z-Wave Configuration Settings Notice 1: All of the configuration, the data size is 1. Notice 2: The reserve bit or not supported bit is allowed any value, but no effect. Notice 3: The PSE04 must stay awake for at least 2 seconds after communicating, so therefore the more communication, the power consumption fast, please pay attention to use configuration NO.1, NO.4, NO.5, NO.6.

NO.NameDef.ValidDescription 1Auto Report Tick Interval0x1E0~255The interval time for auto report each tick. 2Sound Duration0x060~255Play sound duration, 1 tick is 30 seconds. 3Customer Function0x00AllCustomer function switch, using bit control. 0Bit0: Disable Trigger Alarm. 0:Enable , 1:Disable. 0Bit1: Disable Sound. Only using optical alarm. 0:Enable , 1:Disable. 0Bit2: Temperature Unit. 0:Fahrenheit , 1:Celsius. 0Bit3: Reserve. 0Bit4: Reserve. 0Bit5: Reserve.
philo Multiple Sound Wireless Siren (PSE04) — Power Up Procedure diagram (page 7)
Fig. 12 · Power Up Procedure
Page 8 of the philo Multiple Sound Wireless Siren (PSE04) user manual — Caution, avoid listening at high volume levels for long periods
Page 8 · click to enlarge
Page 8

Z-Wave Supported Command Class

Warning

Command ClassVersionRequired Security Class Z-Wave Plus™ Info2None Security1None Security 21None Supervision1None Transport Service2None Association2Highest granted Security Class Association Group Information3Highest granted Security Class Device Reset Locally1Highest granted Security Class Firmware Update Meta Data5Highest granted Security Class Indicator3Highest granted Security Class Manufacturer Specific2Highest granted Security Class Multi-Channel Association3Highest granted Security Class Powerlevel1Highest granted Security Class Version3Highest granted Security Class Configuration4Highest granted Security Class Sensor Multilevel11Highest granted Security Class Basic1Highest granted Security Class Notification8Highest granted Security Class Sound Switch1Highest granted Security Class Battery1Highest granted Security Class
philo Multiple Sound Wireless Siren (PSE04) — Z-Wave Supported Command Class diagram (page 8)
Fig. 13 · Z-Wave Supported Command Class
philo Multiple Sound Wireless Siren (PSE04) — Z-Wave Supported Command Class diagram (page 8)
Fig. 14 · Z-Wave Supported Command Class

Caution, avoid listening at high volume levels for long periods

Choosing a Suitable Location 1. The suitable ambient temperature for the module/device is 0°C~40°C. 2. Do NOT place the module/device direct under sunlight, in a humid place or in any location where they may contact moisture, dirt, dust. 3. Do NOT place the module/device where exists combustible substances or any source of heat, fires, radiators, boiler etc.

philo Multiple Sound Wireless Siren (PSE04) — Caution, avoid listening at high volume levels for long periods diagram (page 8)
Fig. 15 · Caution, avoid listening at high volume levels for l…

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

Philio Technology Corporation 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C) w ww.philio-tech.com

Disposal

Page 9 of the philo Multiple Sound Wireless Siren (PSE04) user manual — 前述合法通信,指依電信管理法規定作業之無線電通信。低功率射頻器材須忍受合 法通信或工業、科學及醫療用電波輻射性電機設備之干擾。」
Page 9 · click to enlarge
Page 9

FCC Interference Statement

警語:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.

「取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變 更頻率、加大功率或變更原設計之特性及功能。

These limits are designed to provide reasonable protection against harmful interference in a residential installation.

低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時, 應立即停用,並改善至無干擾時方得繼續使用。

This equipment generates, uses, and can radiate radio frequency en- ergy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

前述合法通信,指依電信管理法規定作業之無線電通信。低功率射頻器材須忍受合 法通信或工業、科學及醫療用電波輻射性電機設備之干擾。」

However, there is no guarantee that interference will not occur in a particular installation.

  • If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
The device can not join to Z-Wave™ networkThe device may in a Z- Wave™ network. p.2

Ask about the philo Multiple Sound Wireless Siren (PSE04)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the philo Multiple Sound Wireless Siren (PSE04)

Be the first to ask — other owners or our team will answer.

Original document

philo Multiple Sound Wireless Siren (PSE04) manual PDF

9 pages·275 KB·Siren·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…