SEPTEMBER 1998p.1CL050A CL050A-R2p.1CL050C CL050AEp.1RM005p.1RS-232 ↔ Current Loopp.1Interface Converterp.1(232/CL-E)p.1232/CL-Ep.1RX TXp.1CUSTOMERp.1SUPPORT INFORMATIONp.1FCC STATEMENTp.2FEDERAL COMMUNICATIONS COMMISSIONp.2AND CANADIAN DEPARTMENT OF COMMUNICATIONSp.2RADIO FREQUENCY INTERFERENCE STATEMENTSp.21. Specificationsp.32. Introductionp.4Figure 2-1. With the CL050, you can interconnect ap.43. Installationp.54. The Current-Loop Interfacep.64.1 Testing for Other Active Devices on the Current Loopp.64.1.1 LED T ESTp.6R+ RT+ T-p.6CL050Ap.64.2 Connecting the Current Loop Wires to the CL050Ap.74.2.1 4-W IRE C URRENT L OOPp.74.1.2 V OLTMETER T ESTp.74.2.2 2-W IRE C URRENT L OOPp.8Figure 4-6. 2-Wire Half-Duplex Multipointp.10Figure 4-7. 2-Wire Half-Duplex Multipointp.114.3 Switch SWAp.124.4 Switch SWBp.125. The RS-232C Interfacep.135.1 The RS-232C Interface Pinoutp.13RS-232 Interface (Female)p.13SIGNAL DESTINATIONp.13PIN NUMBERp.13PROTECTIVE GROUNDp.13TRANSMITTED DATAp.13RECEIVED DATA REQUEST TO SENDp.13RECEIVED LINE SIGNAL DETECTORp.13+ VOLTAGEp.13- VOLTAGEp.13SECONDARY RECEIVED LINE SIGNAL INDICATORp.13SECONDARY CLEAR TO SENDp.136. Operations and Troubleshootingp.156.1 Indicatorsp.15RX LEDp.15TX LEDp.156.2 Self Testp.167. Current Loop Rack and Cardsp.177.1 Descriptionp.17CURRENT LOOP INTERFACE CONNECTORp.17T+ TR+ R-p.17U6 U5p.17TDp.17WIp.17RD C6 C7p.17POWER CONNECTORp.17Q2p.17DTE/DCEp.17Q3p.17RS-232 INTERFACE CONNECTORp.17U3p.17SW Bp.17SW Ap.17Q1p.17U2p.17U4p.17SW Cp.17SWITCH C (DTE/DCE)p.17
Page 1 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — SUPPORT INFORMATION
Page 1 · click to enlarge
Page 1

SEPTEMBER 1998

CL050A CL050A-R2

CL050C CL050AE

RM005

RS-232 ↔ Current Loop

Interface Converter

(232/CL-E)

232/CL-E

RX TX

CUSTOMER

Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com

SUPPORT INFORMATION

Page 2 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — FCC STATEMENT
Page 2 · click to enlarge
Page 2

FCC STATEMENT

FEDERAL COMMUNICATIONS COMMISSION

AND CANADIAN DEPARTMENT OF COMMUNICATIONS

RADIO FREQUENCY INTERFERENCE STATEMENTS

This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.

Page 3 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 1. Specifications
Page 3 · click to enlarge
Page 3

1. Specifications

Connectors — RS-232/CCITT V.24DB25 (female) Current Loop: 4 screw terminals

Indicators — (2) LEDs indicating RS-232 port activity: RX for Receive Data from an RS-232 external device TX for Transmit Data to an RS-232 external device

Switches — 10-position DIP switch for current-loop transmission mode 10-position DIP switch for RS-232 DTE or DCE configuration 4-position DIP switch for electrical current in the current loop

Maximum Transmission Distance — (based on using 24-AWG solid copper wire):

at 9600 bps300 to 400 meters

(984 to 1,312 feet)

at 300 bps1000 to 3000 meters

(3,281 to 9,843 feet)

Power — Input — 115/220 VAC, 50 to 60 Hz, 12W Output — 18 VAC, center tapped, 8VA

Size — 1.75"H x 5.5"W x 8.5"D (4.4 x 14 x 21.6 cm)

Weight — 1.5 lb. (0.7 kg)

Page 4 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — Figure 2-1. With the CL050, you can interconnect a
Page 4 · click to enlarge
Page 4

2. Introduction

The RS-232 ↔Current Loop Interface Converter (CL050) is a bidirectional self-contained unit that enables the interconnection of a digital 20/30/60mA unipolar current-loop interface with an RS-232 interface. The CL050 cannot be used with an analog current loop (4 to 20 mA) or bipolar current loop.

the CL050 will not supply loop current, but it will operate with 20, 30, or 60 ma unipolar current at up to 30 VDC.

Current loop was designed to transfer data in a noisy environ-ment with as much integrity as possible. The maximum distance that the CL050 can be placed from other devices on the current loop (see Chapter 1) is based on using 24 AWG under ideal conditions, with the CL050 designated as the active device in a point-to-point configuration.

Switch selections allow for half-duplex or full-duplex operation; 20, 30, or 60 mA loop current; and configuring the CL050 as either DTE or DCE.

Two LEDs monitor data flow.

If you ordered the CL050A-R2, you should have received cables with it.

The CL050 can act as either an active or passive device on the current loop. As an active device, the CL050 supplies 20, 30, or 60 ma loop current at 18 VDC for operation. As a passive device,

A 220-volt power supply (CL050E) is also available.

Device using RS-232 Interface

Figure 2-1. With the CL050, you can interconnect a

current loop interface and an RS-232 interface.

Current · Loop Device

Page 5 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 3. Installation
Page 5 · click to enlarge
Page 5

3. Installation

1. Remove the screw located at the center of the bottom cover.
7. Insert the back panel into its guide, making sure the powersupply cable and current-loop cable exit through the holes provided for them.
2. Remove the top cover.
3. Lift the back panel from its guide.
8. Set switches SWA, SWB and SWC to the desired positions. The CL050 is shipped with SWA set to Full-Duplex, Passive; SWB set to 20mA receive; 20mA transmit; and SWC set to DTE. See Sections 4.3, 4.4, and 5.2, respectively, on pages 11 and 13 for more information on these switches.
4. Insert the power supply receptacle into the 4-prong plug (See Figure 7-1 on page 16. The 4-prong plug is near W1). The receptacle should be aligned so that the lip is on the upward side. DO NOT PLUG THE POWER SUPPLY INTO AN AC OUTLET!
5. Test your current loop for active devices. See Section 4.1 on page 11.
9. Replace the top cover.
10. Replace the screw.
6. Connect your current loop to the CL050. See Section 4.2 on page 12.
11. Attach your RS-232C cable.
12. Plug the power supply into an AC outlet. The CL050 is now ready for operation.
Page 6 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — +
Page 6 · click to enlarge
Page 6

4. The Current-Loop Interface

4.1 Testing for Other Active Devices on the Current Loop

4.1.1 LED T EST

(1) Unplug the CL050 from the AC outlet.

You must test for an active device on the current loop if you plan to have the CL050 supply loop current.

(2) Set the SWA switch to full duplex, passive.

(3) Attach the T- of the 4-wire current loop device (or “-” in a 2-wire current loop) to R- of the CL050A.

(4) Attach the T+ of the 4-wire current loop device (or “+” in a 2-wire current loop) to R+ of the CL050A. See Figure 4-1 (4-wire current loop) or Figure 4-2 (2-wire current loop).

There are two tests that you can run. Either is sufficient.

(5) Plug the CL050 into the AC outlet.

R+ RT+ T-

CL050A

Figure 4-1. Wiring configuration for a 4-wire current loop LED test.

+

CL050A

Figure 4-2. Wiring configuration for a 2-wire current loop LED test.

Page 7 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 4.2.1 4-W IRE C URRENT L OOP
Page 7 · click to enlarge
Page 7
4-Wire Full-Duplex 2-Wire Half-Duplex Passive 2-Wire Half-Duplex ActiveTerminals 1 (T+)2 (T-)3 (R+)4 (R-) + Receive + Loop No Connection- Receive Jumper to 3 (R+) + Loop+ Transmit Jumper to 2 (T-) - Loop- Transmit - Loop No Connection Table 1. Current Loop Cable Connections.

(6) Test results:

4.2 Connecting the Current Loop Wires to the CL050A

(a) If the TX LED on the CL050 is off, the other device is active.

When you attach current loop wires to the CL050, the unit should not be connected to an AC outlet. Unless very fine stranded-wire cable is used, wire tinning is not required. Just insert the wire into the receptacle and tighten the screw. The wire will be firmly gripped by the terminal. Table 1 details how the current loop should be connected to the CL050. Refer also to Figures 4-3 through 4-7 on pages 8, 9, and 10.

(b) If the TX LED on the CL050 lights continuously, there is no current in the loop. Therefore, the other current-loop device is passive.

(c) If the TX LED flashes, the current loop is sending data. This indicates that the other device is active.

(7) Unplug the CL050 from the AC outlet and remove the R- to R- and R+ to R+ wires.

4.2.1 4-W IRE C URRENT L OOP

4.1.2 V OLTMETER T EST

Regardless of whether the CL050 is active or passive, attach the current loop wires as indicated in Table 1 and as shown in Figures 4-3 or 4-4.

Attach the voltmeter to the two Transmit lines (T+ and T-) of a current loop device (not the CL050). If the voltmeter reads voltage, the device is active. If no voltage registers, the device is passive.

Page 8 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 4.2.2 2-W IRE C URRENT L OOP
Page 8 · click to enlarge
Page 8

4.2.2 2-W IRE C URRENT L OOP

Connections to a 2-wire half-duplex multipoint current loop depend on whether the CL050 is used as an active or passive unit. Note the connections in Table 1. The connections are also shown in Figures 4-5, 4-6, and 4-7. Note: Not all 2-wire current loops are bidirectional half-duplex. Some current loops are simplex.

Page 9 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 4.2.2 2-W IRE C URRENT L OOP
Page 9 · click to enlarge
Page 9

Figure 4-3. 4-Wire Point-to-Point.

Figure 4-4. 4-Wire Multipoint.

Show 4 more labels / short text on this page
Passive · Active · Passive · Passive
Page 10 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — Figure 4-6. 2-Wire Half-Duplex Multipoint
Page 10 · click to enlarge
Page 10

+

CL050 (set to half-duplex

Figure 4-5. 2-Wire Point-to-Point (half-duplex).

+

+

+

Figure 4-6. 2-Wire Half-Duplex Multipoint

(CL050 passive).

Show 7 more labels / short text on this page
Passive · active) · Passive · Jumper · Active · CL050 (Passive) · Passive
Page 11 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — Figure 4-7. 2-Wire Half-Duplex Multipoint
Page 11 · click to enlarge
Page 11

+

+

+

Figure 4-7. 2-Wire Half-Duplex Multipoint

(CL050 active).

Show 4 more labels / short text on this page
Passive · CL050 (active) · Passive · Passive
Page 12 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 4.4 Switch SWB
Page 12 · click to enlarge
Page 12

4.3 Switch SWA

Switch SWA controls the Current Loop Configuration. The CL050 is shipped with the SWA in a “Full-Duplex, Passive” configuration.

SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW9 SW10 Loop Configuration

0 1 0 1 0 0 1 0 1 0 Full-Duplex, Passive

1 0 1 0 1 1 0 1 0 1 Full-Duplex, Active

0 1 0 1 0 1 0 1 0 1 Full-Duplex, Passive Receive/Active Transmit

1 0 1 0 1 0 1 0 1 0 Full-Duplex, Active Receive/Passive Transmit

0 1 0 1 0 0 1 0 1 0 Half-Duplex, Passive (2-wire operation)

0 1 0 0 1 1 1 0 1 0 Half-Duplex, Active (2-wire operation)

4.4 Switch SWB

Switch SWB controls loop current (20/30/60 mA). The CL050 is shipped with the SWB in a “20mA receive; 20mA transmit” configuration.

SW1 SW2 SW3 SW4 Loop Current

0 20mA receive; 20mA transmit loops

1 60mA receive; 60mA transmit loops

1 1 0 0 60mA receive; 20mA transmit loops

0 0 1 1 20mA receive; 60mA transmit loops

1 0 1 0 30mA receive; 30mA transmit loops

Page 13 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — RECEIVED LINE SIGNAL DETECTOR
Page 13 · click to enlarge
Page 13

5. The RS-232C Interface

5.1 The RS-232C Interface Pinout

Pin Circuit Description Direction

1 AA Protective Ground ---

2 BA Transmit Data To DCE

3 BB Receive Data From DCE

4 CA Request to Send To DCE

5 CB Clear to Send From DCE

6 CC Data Set Ready From DCE

7 AB Signal Ground ---

20 CD Data Terminal Ready To DCE

RS-232 Interface (Female)

SIGNAL DESTINATION

PIN NUMBER

PIN NUMBER

SIGNAL DESTINATION

PROTECTIVE GROUND

1 2 3 4 5 6 7 8 9 10 11 12 13

TRANSMITTED DATA

14 15 16 17 18 19 20 21 22 23 24 25

SECONDARY TRANSMITTED DATA DCE TRANSMITTER SIGNAL ELEMENT TIMING SECONDARY RECEIVED DATA RECEIVER SIGNAL ELEMENT TIMING

RECEIVED DATA REQUEST TO SEND

CLEAR TO SEND DATA SET READY SIGNAL GROUND / COMMON RETURN

SECONDARY REQUEST TO SEND DATA TERMINAL READY SIGNAL QUALITY DETECTOR RING INDICATOR DATA SIGNAL RATE SELECTOR DTE TRANSMITTER SIGNAL ELEMENT TIMING

RECEIVED LINE SIGNAL DETECTOR

+ VOLTAGE

- VOLTAGE

SECONDARY RECEIVED LINE SIGNAL INDICATOR

SECONDARY CLEAR TO SEND

Figure 5-1. The RS-232C Interface.

Page 14 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 5. The RS-232C Interface
Page 14 · click to enlarge
Page 14

5.2 Switch SWC Switch SWC controls the RS-232 Connector Configuration (DCE/DTE).

5.2.1 DCE The CL050 default configuration is DCE. The 10-position DIP switch is set as follows:

SW1 Not Used SW2 OPEN = SW2 and SW3 are ALWAYS in opposite

positions SW3 CLOSED = With SW2 OPEN, Data Out is on Pin 3 SW4 OPEN = SW4 and SW5 are ALWAYS in opposite

positions SW5 CLOSED = With SW4 OPEN, Data In is on Pin 2 SW6 OPEN = Pin 4 (RTS) not connected SW7 CLOSED = Ties Pin 5 (CTS) to Pin 20 (DTR) SW8 OPEN = Removes High on Pin 20 (DTR). If

system does not use DTR, raise CTS by CLOSING both SW7 and SW8 SW9 CLOSED = Place High on Pin 6 (DSR) SW10 Not Used

5.2.2 DTE When configuring the CL050 as a DTE, the 10-position DIP switch is set as follows:

SW1 Not Used SW2 CLOSED = With SW3 OPEN, Data Out is on Pin 2 SW3 OPEN = SW2 and SW3 are ALWAYS in opposite

positions SW4 CLOSED = With SW5 OPEN, Data In is on Pin 3 SW5 OPEN = SW4 and SW5 are ALWAYS in opposite

positions SW6 CLOSED = Place High on Pin 4 (RTS) SW7 OPEN = Pin 5 (CTS) not connected SW8 CLOSED = Place High on Pin 20 (DTR) SW9 OPEN = Pin 6 (DSR) not connected SW10 Not Used

Page 15 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 6.1 Indicators
Page 15 · click to enlarge
Page 15

6. Operations and Troubleshooting

6.1 Indicators

RX LED

TX LED

On ContinuouslyError. Call
On ContinuouslyIndicates

Technical Support.

(1) receive current loop not attached; (2) no current flowing; or (3) you have an open loop. Check the polarity of the receive loop and/or the active/passive options.

OffNo data being received by the RS-

232 port.

FlashingData is being received by the

RS-232 port from the RS-232C interface.

OffThe CL050 is not connected to

an AC outlet or loop current is flowing continuously (which is normal in an idle state).

FlashingData is being transmitted

from the RS-232 port to the RS- 232C interface.

Page 16 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 6.2 Self Test
Page 16 · click to enlarge
Page 16

6.2 Self Test

(6) On the CL050, connect a wire from T+ to R+.

Follow these instructions to test the internal circuitry of the CL050:

(7) Plug the CL050 into an AC outlet.

(8) Set the DTE device to full-duplex.

(1) Unplug the CL050 from AC outlet.

(2) Set switch SWA to full-duplex, transmit active, receive passive.

(9) Enter data.

(10) The TX and RX LEDs should flash and the data should display on the DTE’s monitor. If this occurs, all internal circuitry is operational.

(3) Set switch SWC to DCE configuration.

(4) Attach a DTE device using a straight-pinned cable from the DTE to the CL050.

(5) On the CL050, connect a wire from T- to R-.

Figure 6-1. Wiring for the Internal Circuitry Test.

Show 4 more labels / short text on this page
CL050 RS-232C Cable · + · DTE DCE Configuration · +
Page 17 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — RS-232 INTERFACE CONNECTOR
Page 17 · click to enlarge
Page 17

7. Current Loop Rack and Cards

7.1 Description

voltage selector switch to 115 and make sure the input fuse is rated at 1 A.

The RM005 Rack can hold up to 16 CL050C printed circuit cards and fits in a standard 19-inch equipment rack. The RM005 comes complete with its own built-in AC power supply. The operation of the CL050C is the same as the CL050.

  • For 230 VAC ±15% primary power: The voltage selector switch must be set to 230 and the fuse must be rated 0.5 A.

Inside the fuseholder are two fuses. Open the fuseholder by pressing down on the cover, then release. The fuse closest to the cover is a spare. Select the correct fuses and place them in the Fuse Retaining Cover. Discard the incorrect fuses.

  • For 115 VAC ±15% primary power: Set 115/230

CURRENT LOOP INTERFACE CONNECTOR

T+ TR+ R-

U6 U5

TD

WI

RD C6 C7

POWER CONNECTOR

Q2

DTE/DCE

Q3

SWITCH A (Current Loop Configuration) U1

RS-232 INTERFACE CONNECTOR

U3

SW B

SW A

Q1

U2

U4

SW C

SWITCH C (DTE/DCE)

SWITCH B (20/30/60 mA)

Figure 7-1. Component Layout.

LEDs

Page 18 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 7. Current Loop Rack and Cards
Page 18 · click to enlarge
Page 18
Black Box RS-232 Current Loop Interface Converter (232/CL-E) — 7. Current Loop Rack and Cards diagram (page 18)
Fig. 1 · 7. Current Loop Rack and Cards

Rack Weight — 19.6 lb. (8.9 kg) (without cards installed)

Black Box RS-232 Current Loop Interface Converter (232/CL-E) — 7. Current Loop Rack and Cards diagram (page 18)
Fig. 2 · 7. Current Loop Rack and Cards
Page 19 of the Black Box RS-232 Current Loop Interface Converter (232/CL-E) user manual — 7. Current Loop Rack and Cards
Page 19 · click to enlarge
Page 19

© Copyright 1998. Black Box Corporation. All rights reserved.

  • 1000 Park Drive
  • Lawrence, PA 15055-1018
  • 724-746-5500
  • Fax 724-746-0746
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Black Box RS-232 Current Loop Interface Converter (232/CL-E)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Black Box RS-232 Current Loop Interface Converter (232/CL-E)

Be the first to ask — other owners or our team will answer.

Original document

Black Box RS-232 Current Loop Interface Converter (232/CL-E) manual PDF

23 pages·154 KB·Converter·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…