EN
Official user manual

MEGA DECO Flex L

8 pages·284 KB·Light·PDF·ENDEFRITNLJA
MEGA DECO Flex L
Table of Contents 21 sections USER MANUAL · Table of Contents · Check that the unit has not been damaged during transport · IP 66 · … ShowHide
Page 3 of the MEGA DECO Flex L user manual — IP 66
Page 3 · click to enlarge
Page 3

Check that the unit has not been damaged during transport

Check that the unit has not been damaged during transport

MEGA DECO Flex L — Check that the unit has not been damaged during transport diagram (page 3)
Fig. 1 · Check that the unit has not been damaged during tran…
1. Maintain a minimum of 1 foot distance from any type of flame. 2. Do Not install the unit too close to a heat source. 3. Make sure cables are properly secured away from movement. 4. Maximum surface operating temperature is 125°F 5. Unit must not be left on for long periods of time.

Protection Against Electrical Fire

Protection Against Electrical Fire

1. Disconnect power before servicing. 2. For connection to main power supply proceed to page 5. 3. This fixture must not be left on for long periods of time.

Protection Against Mechanical Hazards 1. Use safety measures when hanging unit. 2. Use quality clamps or bolts when positioning unit 3. Do not open, risk of electrical shock.

Protection Against Mechanical Hazards

MEGA DECO Flex L — Check that the unit has not been damaged during transport diagram (page 3)
Fig. 2 · Check that the unit has not been damaged during tran…

The IP rating is commonly expressed as IP (Ingress Protection) is followed by 2 numbers (i.e. 66) where the numbers define the fixture rating. The first number indicates the size of a particle that can enter the fixture.. The second number indicates the extent of protection against water entering the fixture. An IP66 rating in this fixture indicates that dust particles can not enter the fixture. And there is protection against powerful water spray from entering the fixture from any direction.

IP 66

What is Included

1pc Deco Flex L 6pc Single Point Mounting Clips 1pc User Manual

Protection Against Fire · Protection Against Fire · Ingress Protection

Page 4 of the MEGA DECO Flex L user manual — Electrical Specifications
Page 4 · click to enlarge
Page 4

Specifications

Part Numbers

5050L– Deco Flex L

Mechanical Specifications

IP Rating: IP66 Fastening System: 6 Mounting Clips (included) Power Connection: 5 Conductor Cable Housing: Silicone type material (3 type) Housing Type: Flat Top Curving Type: Up & Down Curve (when light output is facing up) Length: 19’ Feet 10.5” Inch Including Cable (605.79cm) Cuttable: Cuttable mark located on the bottom, Cuttable every 2.81” inch (71.42mm) LED Spacing:.46” inch (11.9mm)

Electrical Specifications

LED Type: SMD 5050 R,G,B,WW LED Qty: 504 Color Temp WW: 3000K Each LED Watts: .19 Power Input: 24V Total Max Power: 94W Drive Method: Constant Voltage

Fixture

Page 5 of the MEGA DECO Flex L user manual — Ch4 Mode
Page 5 · click to enlarge
Page 5

Main Power Connection

The occupation of the connection-cable is as follows:

COMVoltage +Black Cable RRedRed Cable GGreenGreen Cable BBlueBlue Cable WWarm WhiteWhite Cable

DMX-512 Control

When using the Deco Flex L with Deco Drivers the fixture is intended to be used in Ch4 or Ch7 modes. The Deco Driver will be required to be set in Ch4 or Ch7 operating modes

Ch4 Mode

Ch7 Mode

Deco Driver Info

Power Link1 UnitCan connect 1 unit per output port Ch ModeCh 4 or Ch7Use Ch4 or Ch7 Mode to control the unit
Show 7 more labels / short text on this page
Red Green · Dimmer · Red Green · Blue Warm White · Blue Warm White · Strobe · Macro
Page 6 of the MEGA DECO Flex L user manual — Tube With End Cap
Page 6 · click to enlarge
Page 6

Size & Weight

Tube With End Cap

MEGA DECO Flex L — Tube With End Cap diagram (page 6)
Fig. 3 · Tube With End Cap
MEGA DECO Flex L — Tube With End Cap diagram (page 6)
Fig. 4 · Tube With End Cap
MEGA DECO Flex L — Tube With End Cap diagram (page 6)
Fig. 5 · Tube With End Cap

19’ Feet 10.5” Inches (Including Cable) / 19’ Feet 9.25” (Without Cable)

Fixture Size19’10.5" (605.79cm) X 18mm X 18mm Fixture Packaged15" X 15" X 1.5" Net Weight4lb Gross Weight4.1lb
Show 5 more labels / short text on this page
16mm · 18mm · 6mm · 16mm · 18mm
Page 7 of the MEGA DECO Flex L user manual — Accessories
Page 7 · click to enlarge
Page 7

Cleaning and Maintenance

Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installation and electronics checked by an expert every 2 years. The following points have to be considered during the inspection: 1) All screws used for installing the device or part of the device have to be tightly connected and must not be corroded. 2) There must not be any deformations on the housing, fixation and installation spots. 3) The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed. 4) Flex Tube must only be cleaned using soap and water

Rigging the Fixture

When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experi- ence including but not limited to calculating working loads, material being used and periodic safety inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger. When rigging the unit always be secured with a secondary safety attachment. The installation location of the Fixture has got to be built in the way that it can hold 10 times the weight for 1 hour with out any failures. Installation should be checked at least one time a year by a skilled person.

Accessories

5050LACCSIN (single point mounting clip) 5050LACCFLE (flexible mounting holder 1 meter)

MEGA DECO Flex L — Accessories diagram (page 7)
Fig. 6 · Accessories
MEGA DECO Flex L — Accessories diagram (page 7)
Fig. 7 · Accessories

CONCOLDC5 (5PIN IP rated connection) 5050LACCEXT (rigid extrusion 1 meters)

MEGA DECO Flex L — Accessories diagram (page 7)
Fig. 8 · Accessories

5050LACCCAPR (right angle cap ) 5050LACCCAP (end cap)

5050LACCCAPL (left angle cap )

MEGA DECO Flex L — Accessories diagram (page 7)
Fig. 9 · Accessories
MEGA DECO Flex L — Accessories diagram (page 7)
Fig. 10 · Accessories
MEGA DECO Flex L — Accessories diagram (page 7)
Fig. 11 · Accessories
Page 8 of the MEGA DECO Flex L user manual — Document
Page 8 · click to enlarge
Page 8

Warranty Information Warranty Conditions -Unless otherwise stated in writing, your product is covered by a one year parts and labor limited warranty. -LED’s and LAMPS are not guaranteed to match in color or output. -It is the owner’s responsibility to furnish receipts or invoices for verification of purchase, date, and reseller or distributor. If purchase date cannot be provided, date of manufacture will be used to determine warranty period. -Goods returned under warranty must follow the proper authorization procedure and must be accompanied by a copy of the original invoice. -Goods repaired under warranty will be returned to the owner with the freight prepaid by MSI via the most economical means of shipment. -Repair or replacement as provided for under this warranty is the exclusive remedy of the consumer. MEGA SYSTEMS INC. makes no warranties, express or implied, with respect to any product, and Mega Systems specifically disclaims any warranty of merchantability or fitness for a particular purpose. Mega Systems shall not be liable for any indirect, inci- dental or consequential damage, including lost profit, sustained or incurred in connection with any product or caused by product defect or the partial or total failure of any product regardless of the form of action, whether in contract, tort (including negligence), strict liability or otherwise, and whether or not such damage was foreseen or unforeseen. - Warranty is void if the product is misused, damaged, modified in any way, or for unauthorized repairs or parts. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Customer Support Mega Lite has a customer support line to provide set up help and to answer any question should you encounter a prob- lem. Please visit our website for any other related technical documents. For service related issue please contact our service dept. Monday—Friday 9am to 6pm CST Voice: 210-684-2600 E-mail: service@megasystemsinc.com

Manual Version Please Visit www.mega.lighting for the most up to date manual version

Document

Version Date Fixture Software Notes

1.2 12/09/2020 N/A Power Input Updated

MEGA DECO Flex L — Document diagram (page 8)
Fig. 12 · Document

Mega Lite 18668 Highway 16N Helotes, Texas 78023 Ph 210-684-2600 Fax 210-855-6279 www.mega.lighting / [email protected]

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the MEGA DECO Flex L

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the MEGA DECO Flex L

Be the first to ask — other owners or our team will answer.

Original document

MEGA DECO Flex L manual PDF

8 pages·284 KB·Light·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…