Check that the unit has not been damaged during transport

Protection Against Electrical Fire
Protection Against Electrical Fire
Protection Against Mechanical Hazards 1. Use safety measures when hanging unit. 2. Use quality clamps or bolts when positioning unit 3. Do not open, risk of electrical shock.
Protection Against Mechanical Hazards

The IP rating is commonly expressed as IP (Ingress Protection) is followed by 2 numbers (i.e. 66) where the numbers define the fixture rating. The first number indicates the size of a particle that can enter the fixture.. The second number indicates the extent of protection against water entering the fixture. An IP66 rating in this fixture indicates that dust particles can not enter the fixture. And there is protection against powerful water spray from entering the fixture from any direction.
What is Included
1pc Deco Flex L 6pc Single Point Mounting Clips 1pc User Manual
Protection Against Fire · Protection Against Fire · Ingress Protection

5050L– Deco Flex L
IP Rating: IP66 Fastening System: 6 Mounting Clips (included) Power Connection: 5 Conductor Cable Housing: Silicone type material (3 type) Housing Type: Flat Top Curving Type: Up & Down Curve (when light output is facing up) Length: 19’ Feet 10.5” Inch Including Cable (605.79cm) Cuttable: Cuttable mark located on the bottom, Cuttable every 2.81” inch (71.42mm) LED Spacing:.46” inch (11.9mm)
LED Type: SMD 5050 R,G,B,WW LED Qty: 504 Color Temp WW: 3000K Each LED Watts: .19 Power Input: 24V Total Max Power: 94W Drive Method: Constant Voltage
Fixture

The occupation of the connection-cable is as follows:
When using the Deco Flex L with Deco Drivers the fixture is intended to be used in Ch4 or Ch7 modes. The Deco Driver will be required to be set in Ch4 or Ch7 operating modes
Ch7 Mode
Deco Driver Info




19’ Feet 10.5” Inches (Including Cable) / 19’ Feet 9.25” (Without Cable)

Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installation and electronics checked by an expert every 2 years. The following points have to be considered during the inspection: 1) All screws used for installing the device or part of the device have to be tightly connected and must not be corroded. 2) There must not be any deformations on the housing, fixation and installation spots. 3) The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed. 4) Flex Tube must only be cleaned using soap and water
When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experi- ence including but not limited to calculating working loads, material being used and periodic safety inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger. When rigging the unit always be secured with a secondary safety attachment. The installation location of the Fixture has got to be built in the way that it can hold 10 times the weight for 1 hour with out any failures. Installation should be checked at least one time a year by a skilled person.
5050LACCSIN (single point mounting clip) 5050LACCFLE (flexible mounting holder 1 meter)


CONCOLDC5 (5PIN IP rated connection) 5050LACCEXT (rigid extrusion 1 meters)

5050LACCCAPR (right angle cap ) 5050LACCCAP (end cap)
5050LACCCAPL (left angle cap )




Warranty Information Warranty Conditions -Unless otherwise stated in writing, your product is covered by a one year parts and labor limited warranty. -LED’s and LAMPS are not guaranteed to match in color or output. -It is the owner’s responsibility to furnish receipts or invoices for verification of purchase, date, and reseller or distributor. If purchase date cannot be provided, date of manufacture will be used to determine warranty period. -Goods returned under warranty must follow the proper authorization procedure and must be accompanied by a copy of the original invoice. -Goods repaired under warranty will be returned to the owner with the freight prepaid by MSI via the most economical means of shipment. -Repair or replacement as provided for under this warranty is the exclusive remedy of the consumer. MEGA SYSTEMS INC. makes no warranties, express or implied, with respect to any product, and Mega Systems specifically disclaims any warranty of merchantability or fitness for a particular purpose. Mega Systems shall not be liable for any indirect, inci- dental or consequential damage, including lost profit, sustained or incurred in connection with any product or caused by product defect or the partial or total failure of any product regardless of the form of action, whether in contract, tort (including negligence), strict liability or otherwise, and whether or not such damage was foreseen or unforeseen. - Warranty is void if the product is misused, damaged, modified in any way, or for unauthorized repairs or parts. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Customer Support Mega Lite has a customer support line to provide set up help and to answer any question should you encounter a prob- lem. Please visit our website for any other related technical documents. For service related issue please contact our service dept. Monday—Friday 9am to 6pm CST Voice: 210-684-2600 E-mail: service@megasystemsinc.com
Manual Version Please Visit www.mega.lighting for the most up to date manual version
Version Date Fixture Software Notes
1.2 12/09/2020 N/A Power Input Updated