EN
Planet Technology logo
Official user manual

Planet Technology Managed Switch (SEP)

16 pages·1.1 MB·Switch·PDF·ENDEFRITNLJA
Planet Technology Managed Switch (SEP)
Table of Contents 26 sections 16-/24-/48-Port 10/100/1000T + · 2-/4-Port 100/1000X SFP Managed Switch · GS-4210-16T2S/GS-4210-24T2S · GS-4210-24T4S/GS-4210-24T4SR · … ShowHide
Page 1 of the Planet Technology Managed Switch (SEP) user manual — 16-/24-/48-Port 10/100/1000T +
Page 1 · click to enlarge
Page 1

16-/24-/48-Port 10/100/1000T +

2-/4-Port 100/1000X SFP Managed Switch

GS-4210-16T2S/GS-4210-24T2S

GS-4210-24T4S/GS-4210-24T4SR

GS-4210-48T4S

Quick Installation Guide

Page 2 of the Planet Technology Managed Switch (SEP) user manual — 16-/24-/48-Port 10/100/1000T +
Page 2 · click to enlarge
Page 2
Page 2 of the Planet Technology Managed Switch (SEP) user manual — 16-/24-/48-Port 10/100/1000T +
Page 3 of the Planet Technology Managed Switch (SEP) user manual — 1. Package Contents
Page 3 · click to enlarge
Page 3

1. Package Contents

Thank you for purchasing PLANET GS-4210 Managed Switch series. The descriptions of this series are shown below:

GS-4210-16T2S16-Port Layer 2 Managed Gigabit Ethernet Switch w/2 SFP Interfaces GS-4210-24T2S24-Port Layer 2 Managed Gigabit Ethernet Switch w/2 SFP Interfaces GS-4210-24T4S24-Port 10/100/1000T + 4-Port 100/1000X SFP Managed Gigabit Switch GS-4210-24T4SR24-Port 10/100/1000T + 4-Port 100/1000X SFP Managed Gigabit Switch with 36-72V DC Redundant Power GS-4210-48T4S48-Port Layer 2 Managed Gigabit Ethernet Switch w/4 SFP Interfaces

“Managed Switch” is used as an alternative name in this Quick Installation Guide.

Open the box of the Managed Switch and carefully unpack it. The box should contain the following items:

z The Managed Switch x 1

z Quick Installation Guide x 1

z RS232 to RJ45 Cable x 1

z Rubber Feet x 4

z Two Rack-mounting Brackets with Attachment Screws x 1

z Power Cord x 1

z SFP Dust-proof Cap

SFP Dust-proof Caps GS-4210-16T2S2 GS-4210-24T2S2 GS-4210-24T4S GS-4210-24T4SR GS-4210-48T4S4

If any item is found missing or damaged, please contact your local reseller for replacement.

Page 4 of the Planet Technology Managed Switch (SEP) user manual — 2. Requirements
Page 4 · click to enlarge
Page 4

2. Requirements

z Workstations running Windows XP/2003/2008/2012/Vista/7/8/10, MAC OS X or

later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols.

z Workstations are installed with Ethernet NIC (Network Interface Card).

z Serial Port Connection (Terminal)

The above Workstations come with COM Port (DB9) or USB-to-RS-232

The above Workstations have been installed with terminal emulator, such as

Hyper Terminal included in Windows XP/2003.

Serial cable -- one end is attached to the RS-232 serial port, while the other

end to the console port of the Managed Switch.

z Ethernet Port Connection

Network cables -- Use standard network (UTP) cables with RJ45 connectors.

The above PC is installed with Web browser.

It is recommended to use Internet Explorer 8.0 or above to access the Managed Switch. If the Web interface of the Managed Switch is not accessible, please turn off the anti-virus software or firewall and then try it again.

converter

Page 5 of the Planet Technology Managed Switch (SEP) user manual — 115200,N,8,1
Page 5 · click to enlarge
Page 5

3. Terminal Setup

To configure the system, connect a serial cable to a COM port on a PC or notebook computer while the other end to RJ45 console port of the Managed Switch.

Planet Technology Managed Switch (SEP) — 3. Terminal Setup diagram (page 5)
Fig. 1 · 3. Terminal Setup

115200,N,8,1

PC / Workstation with Terminal Emulation Software

RJ45 to RS232 Cable

Figure 3-1Managed Switch Console Connectivity

A terminal program is required to make the software connection to the Managed Switch.

1. Run terminal program on the OS.
2. When the following screen appears, make sure that the COM port should be configured as:
Baud115200
Planet Technology Managed Switch (SEP) — 115200,N,8,1 diagram (page 5)
Fig. 2
Data bits8
ParityNone
Stop bits1
Flow controlNone
Figure 3-2COM Port Configuration
Show 4 more labels / short text on this page
Managed Switch · Console · Serial Port 115200,N,8,1 · Serial Port
Page 6 of the Planet Technology Managed Switch (SEP) user manual — 3.2 Configuring IP Address via the Console
Page 6 · click to enlarge
Page 6

3.1 Logging on to the Console

Once the terminal is connected to the device, power on the Managed Switch and the terminal will run self testing procedures. Then, the following message asks to log in user name and password. The factory default user name and password are shown as follows and the login screen in Figure 3-3 appears.

Usernameadmin Password: admin

The following console screen based on the GS-4210-24T4S will be the same as those of GS-4210-16T2S, GS-4210-24T2S, GS-4210- 24T4SR and GS-4210-48T4S.

Planet Technology Managed Switch (SEP) — 3.1 Logging on to the Console diagram (page 6)
Fig. 3 · 3.1 Logging on to the Console
Figure 3-3Managed Switch Console Login Screen

The user can now enter commands to manage the Managed Switch. For a detailed description of the commands, please refer to the following chapters.

1. For security reason, please change and memorize the new password after this first setup.
2. Only accept command in lowercase letter under console interface.

3.2 Configuring IP Address via the Console

The Managed Switch is shipped with default IP address as follows:

IP Address192.168.0.100 Subnet Mask: 255.255.255.0
Page 7 of the Planet Technology Managed Switch (SEP) user manual — Configuration of the IP address
Page 7 · click to enlarge
Page 7

To check the current IP address or modify a new IP address for the Managed Switch, please use the procedures as follows:

Display of the current IP address

1. On “GS-4210-24T4S#” prompt, enter “show ip” .
2. The screen displays the current IP address, subnet mask and gateway shown in Figure 3-4.
Planet Technology Managed Switch (SEP) — Display of the current IP address diagram (page 7)
Fig. 4 · Display of the current IP address
Figure 3-4IP Information Screen

Configuration of the IP address

3. On “GS-4210-24T4S#” prompt, enter “configure” .
4. On “GS-4210-24T4S (config)#” prompt, enter the following command and press as shown in Figure 3-5.

GS-4210-24T4S (config)# ip address 192.168.1.100 mask 255.255.255.0 GS-4210-24T4S (config)# ip default-gateway 192.168.1.254

The previous command would apply the following settings for the Managed Switch.

IP Address192.168.1.100 Subnet Mask: 255.255.255.0 Gateway: 192.168.1.254
Planet Technology Managed Switch (SEP) — Configuration of the IP address diagram (page 7)
Fig. 5 · Configuration of the IP address
Figure 3-5Setting IP Address Screen
5. Repeat Step 1 to check if the IP address has changed.
Page 8 of the Planet Technology Managed Switch (SEP) user manual — 3.3 Storing Current Switch Configuration
Page 8 · click to enlarge
Page 8

If the IP is successfully configured, the Managed Switch will apply the new IP address setting immediately. You can access the Web interface of Managed Switch through the new IP address.

If you are not familiar with console command or the related parameter, enter “?” anytime in console to get the help descrip- tion.

3.3 Storing Current Switch Configuration

In switches, the running configuration file is stored in the RAM. In the current version, the running configuration sequence can be saved from the RAM to FLASH by saving command or copying running-config startup-config command, so that the running configuration sequence becomes the startup configuration file, which is called configuration save.

1. On “GS-4210-24T4S #” prompt, enter “copy running-config startup-config” as shown in Figure 3-6.
Planet Technology Managed Switch (SEP) — 3.3 Storing Current Switch Configuration diagram (page 8)
Fig. 6 · 3.3 Storing Current Switch Configuration
Figure 3-6Saving the Configuration Screen
Page 9 of the Planet Technology Managed Switch (SEP) user manual — 4.1 Logging in to the Managed Switch
Page 9 · click to enlarge
Page 9

4. Starting Web Management

The following shows how to start up the Web Management of the Managed Switch. Note the Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.

For example, the default IP address of the Managed Switch is 192.168.0.100; then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100) and the default subnet mask is 255.255.255.0.

PC / Workstation with Web Browser

192.168.0.x

IP Address192.168.0.100
Figure 4-1IP Management Diagram

4.1 Logging in to the Managed Switch

1. Use Internet Explorer 8.0 or above Web browser and enter IP address http://192.168.0.100 to access the Web interface.
2. When the following dialog box appears, please enter the default user name and password “admin” . The login screen in Figure 4-2 appears.
Default IP address192.168.0.100 Default Username: admin Default Password: admin

Managed Switch · RJ45/UTP Cable

Page 10 of the Planet Technology Managed Switch (SEP) user manual — 4. Starting Web Management
Page 10 · click to enlarge
Page 10
Planet Technology Managed Switch (SEP) — 4. Starting Web Management diagram (page 10)
Fig. 7 · 4. Starting Web Management
Figure 4-2Web Login Screen

The following web screen based on GS-4210-24T4S will be the same as that of GS-4210-16T2S, GS-4210-24T2S, GS-4210- 24T4SR and GS-4210-48T4S.

3. After entering the password, the main screen appears as Figure 4-3 shows.
Planet Technology Managed Switch (SEP) — 4. Starting Web Management diagram (page 10)
Fig. 8 · 4. Starting Web Management
Figure 4-3Web Main Screen of Managed Switch
Page 11 of the Planet Technology Managed Switch (SEP) user manual — 4. Starting Web Management
Page 11 · click to enlarge
Page 11

The Switch Menu on the left of the Web page lets you access all the commands and statistics the Managed Switch provides.

Planet Technology Managed Switch (SEP) — 4. Starting Web Management diagram (page 11)
Fig. 9 · 4. Starting Web Management
Planet Technology Managed Switch (SEP) — 4. Starting Web Management diagram (page 11)
Fig. 10 · 4. Starting Web Management
Figure 4-4Switch Menu

Now, you can use the Web management interface to continue the switch management. Please refer to the user’s manual for more.

Page 12 of the Planet Technology Managed Switch (SEP) user manual — 4.2 Saving Configuration via the Web
Page 12 · click to enlarge
Page 12

4.2 Saving Configuration via the Web

Save all applied changes and set the current configuration as a startup configuration. The startup-configuration file will be loaded automatically across a system reboot.

1. Click “SAVE > Save Configurations to FLASH” to log in “Configuration Manager” Page.
Planet Technology Managed Switch (SEP) — 4.2 Saving Configuration via the Web diagram (page 12)
Fig. 11 · 4.2 Saving Configuration via the Web
2. Press the “Apply” button to save running configuration as startup configuration.
Planet Technology Managed Switch (SEP) — 4.2 Saving Configuration via the Web diagram (page 12)
Fig. 12 · 4.2 Saving Configuration via the Web
Page 13 of the Planet Technology Managed Switch (SEP) user manual — PWR
Page 13 · click to enlarge
Page 13

5. Recovering Back to Default Configuration

IP address has been changed or admin password has been

forgotten –

To reset the IP address to the default IP address “192.168.0.100” or reset the login password to default value, press the reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the Web interface management within the same subnet of 192.168.0.xx.

16-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch

PWR

ACT LNK 1000 ACT LNK 100

GS-4210-16T2S

ACT LNK 1000 ACT LNK 10/100

Figure 5-1GS-4210-16T2S Reset Button
Planet Technology Managed Switch (SEP) — PWR diagram (page 13)
Fig. 13
Figure 5-2GS-4210-24T2S Reset Button
Planet Technology Managed Switch (SEP) — PWR diagram (page 13)
Fig. 14
Figure 5-3GS-4210-24T4S/GS-4210-24T4SR Reset Button
Show 4 more labels / short text on this page
15 Reset · Reset · Reset · Reset
Page 14 of the Planet Technology Managed Switch (SEP) user manual — 5. Recovering Back to Default Configuration
Page 14 · click to enlarge
Page 14
Planet Technology Managed Switch (SEP) — 5. Recovering Back to Default Configuration diagram (page 14)
Fig. 15 · 5. Recovering Back to Default Configuration

33 32 34 35 36 37 38 39 40 42 41 43 45 44 46 47 48

Figure 5-4GS-4210-48T4S Reset Button

Reset

Page 15 of the Planet Technology Managed Switch (SEP) user manual — 6. Customer Support
Page 15 · click to enlarge
Page 15

6. Customer Support

Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.

PLANET online FAQshttp://www.planet.com.tw/en/support/faq
Switch support team mail addresssupport@ planet.com .tw
GS-4210 Series User’s Manualhttps://www.planet.com.tw/en/support/downloads?&method=keyword&keyword= GS-4210&view=3#list

Copyright © PLANET Technology Corp. 2020. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.

Page 16 of the Planet Technology Managed Switch (SEP) user manual — 6. Customer Support
Page 16 · click to enlarge
Page 16
Page 16 of the Planet Technology Managed Switch (SEP) user manual — 6. Customer Support
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Planet Technology Managed Switch (SEP)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Planet Technology Managed Switch (SEP)

Be the first to ask — other owners or our team will answer.

Original document

Planet Technology Managed Switch (SEP) manual PDF

16 pages·1.1 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…