PAWKIT Water Activity Meter

2 pages·95 KB·Measuring Tool·PDF·ENDEFRITNLJA
PAWKIT Water Activity Meter
Table of Contents 14 sections PAWKIT WATER ACTIVITY METER · SUPPORT · NORTH AMERICA · EUROPE · … ShowHide
Page 1 of the PAWKIT Water Activity Meter user manual — NORTH AMERICA
Page 1 · click to enlarge
Page 1
PAWKIT Water Activity Meter — PAWKIT WATER ACTIVITY METER diagram (page 1)
Fig. 1

PAWKIT WATER ACTIVITY METER

SUPPORT

Have a question or problem? Our support team can help.

We manufacture, test, calibrate, and repair every instrument in house. Our scientists and technicians use the instruments every day in our product testing lab. No matter what your question is, we have someone who can help you answer it.

NORTH AMERICA

EUROPE

Emailsupport.food@ metergroup.com Phone: +1.509.332.5600
Emailsupport.eu rope@ metergroup.com Phone: +49 89 12 66 52 0
Page 2 of the PAWKIT Water Activity Meter user manual — 3. Place Sample
Page 2 · click to enlarge
Page 2

10341-07 10.2021

AQUALAB PAWKIT QUICK START

Preparation

Verification Versus Calibration

Confirm that all AQUALAB PAWKIT components are intact. For set up before taking a reading, gather the following items from the kit: sample material and cup, verification standards, PAWKIT meter.

Verification

The PAWKIT needs to be verified with a primary and secondary verification standard every day. Measuring one standard at the bottom of a water activity range and one towards the top of the range will alert the operator to shifts in the calibration.

Read the full AQUALAB PAWKIT manual at metergroup.com/pawkit- support. All products have a 30-day satisfaction guarantee.

Calibration

If a shift occurs and the standard isn’t measuring within specifications, clean the instrument. If the standard is still not measuring within specifications, start with the 0.760 standard and adjust the calibration up or down. Then move on to the 0.250 or 0.920 standard as appropriate. Refer to the user manual for detailed instructions.

Installation

1. Select Location

2. Prepare Sample

Place the PAWKIT on a level surface when measuring to ensure correct and consistent operation. This also prevents the risk of spilling inside the PAWKIT. Place the PAWKIT where the temperature remains fairly stable to avvoid inaccurate readings.

Take special care when preparing the sample in order to get the best readings possible. Always use clean sampling practices to ensure accurate and repeatable readings. Use a homogenous sample, wash hands thoroughly, fill sample cup no more than half full, and clean the sample cup’s bottom, edges, and rim thoroughly with KIMWIPES® strips.

3. Place Sample

4. Take a Reading

Open the PAWKIT sensor cover and rotate and snap into open position. Place prepared sample cup on a level surface. Place opened PAWKIT onto the prepared sample cup.

Press the I button to turn PAWKIT on. Press the I button a second time to begin the water activity measurement. After 5 min, the PAWKIT displays the final water activity and beeps 5 times.

KIMWIPES® is a registered trademark of Kimberly-Clark Worldwide, Inc. Used with permission.

Sample cup · I button

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the PAWKIT Water Activity Meter

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the PAWKIT Water Activity Meter

Be the first to ask — other owners or our team will answer.

Original document

PAWKIT Water Activity Meter manual PDF

2 pages·95 KB·Measuring Tool·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…