Bogen Telephone Interface Module (TEL1S)

3 pages·108 KB·Communications·PDF·ENDEFRITNLJA
Bogen Telephone Interface Module (TEL1S)
Table of Contents 11 sections Jumper Selections · Bus Assignment · Interface Type · Priority Level * · … ShowHide
Page 1 of the Bogen Telephone Interface Module (TEL1S) user manual
Page 1 · click to enlarge
Page 1
Bogen Telephone Interface Module (TEL1S) diagram (page 1)
Fig. 1
Bogen Telephone Interface Module (TEL1S) diagram (page 1)
Fig. 2
Bogen Telephone Interface Module (TEL1S) diagram (page 1)
Fig. 3

© 2003 Bogen Communications, Inc. Specifications subject to change without notice. 54-2055-01D 0808

Page 2 of the Bogen Telephone Interface Module (TEL1S) user manual — Telephone System Connections
Page 2 · click to enlarge
Page 2
Bogen Telephone Interface Module (TEL1S) — Jumper Selections diagram (page 2)
Fig. 4 · Jumper Selections

Jumper Selections

Bogen Telephone Interface Module (TEL1S) — Jumper Selections diagram (page 2)
Fig. 5 · Jumper Selections
1. Turn off all power to the unit.

Bus Assignment

This module can be set to operate so that the input signal can be sent to the main unit’s A bus, B bus, or both buses.

3. Position the module in front of desired module bay opening, making sure that the module is right-side up.

Interface Type

Dry Loop - Use with page ports. Activated by audio activity on the telephone line.

4. Slide the module onto the card guide rails. Make sure that both the top and bottom guides are engaged.

Loop Start - Use when interfacing to PBX loop start trunks or dedicated telephones. Requires connection of external power supply (see Block Diagram for more info).

5. Push the module into the bay until the faceplate contacts the unit’s chassis.

Ground Start - Use only on PBX ground start trunks. Requires connection of external power supply and connection to PBX ground.

6. Use the two screws included to secure the module to the unit.

Priority Level *

This module can respond to 4 different levels of priority. Priority 1 is the highest priority. It mutes modules with lower priorities and is never muted. Priority 2 can be muted by Priority 1 modules and mutes modules set for 3 or 4. Priority 3 is muted by either Priority 1 or 2 modules and mutes Priority 4 modules. Priority 4 modules are muted by all higher priority modules.

J4 J9 J6 J4 J9 J6 J4 J9 J6 J4 J9 J6

* The number of priority levels available is determined by the amplifier the modules are used in.

Limiter (Limit)

Sets the signal level threshold at which the module will begin to limit the level of its output signal. Clockwise rotation will allow more output signal before limiting, counterclockwise rotation will allow less. The limiter monitors the module’s output signal level, so increasing gain will affect when limiting takes place.

Gate - Threshold (Thresh)

Controls the minimum necessary input signal level to turn the module’s output on and apply signal to the main unit’s buses. Clockwise rotation increases the necessary signal level required to produce output and mute lower priority modules.

Gain

Gate - Duration (Dur)

Provides control over the level of input signal that can be applied to the internal signal buses of the main unit. Allows a way to balance the input levels of various devices so that the main unit controls can be set to relatively uniform or optimum levels. Clockwise rotation will increase gain, counterclockwise rotation decreases gain.

Controls the amount of time the output and mute signal of the module remains applied to the main unit’s buses after the input signal falls below the required minimum signal level (set by the threshold control). Clockwise rota- tion will increase time duration, counterclockwise will decrease duration with- in a 0.5s to 5s range.

Telephone System Connections

Power Supply Connections

Connect the telephone system’s Tip line to the “T” terminal and the Ring line to the “R” terminal. When interfacing to a ground start trunk, also connect a wire from the PBX’s ground to the module’s “CM” terminal. In some cases, the power supply’s ground connection alone will be adequate. For Dry Loop (Page Ports), connect the audio pair to the module’s “T” & “R” terminals (polarity insensitive). No power supply is necessary. The module is audio-activated so a contact pair from the page port is not needed.

Interfacing to a loop or ground start trunk requires an external 48V power supply to be connected to the module. Make connections as marked. The ground connection is optional, but can be helpful when interfacing to ground start trunks. Bogen Model PRS48 is recommended.

Page 3 of the Bogen Telephone Interface Module (TEL1S) user manual — Connections
Page 3 · click to enlarge
Page 3

Connections

Ground Start Interface Troubleshooting

Bogen Telephone Interface Module (TEL1S) — Connections diagram (page 3)
Fig. 6 · Connections
1. Check that trunk is a Ground Start type. Try other trunk style connections. If there is DC voltage on the telephone line, it is a station line and cannot be interfaced to this module. 2. Check jumper settings. 3. Check power supply connections and operation. 4. Check connection between CM terminal and the PBX’s ground. 5. Try reversing T & R connections.
Bogen Telephone Interface Module (TEL1S) — Connections diagram (page 3)
Fig. 7 · Connections

Loop Start Interface Troubleshooting

1. Check that trunk is a Loop Start type. Try other trunk style connections. If there is DC voltage on the telephone line, it is a station line and cannot be interfaced to this module. 2. Check jumper settings. 3. Check power supply connections and operation. 4. Try reversing T & R connections.

Page Port Interface Troubleshooting

Bogen Telephone Interface Module (TEL1S) — Connections diagram (page 3)
Fig. 8 · Connections
1. Check that there is no DC voltage on the telephone line. If there is, it is a station line and cannot be interfaced to this module. 2. Check jumper settings. 3. Check that audio is present at audio pair leads of page port. 4. Adjust Threshold control on module.
Bogen Telephone Interface Module (TEL1S) — Connections diagram (page 3)
Fig. 9 · Connections

48VDC @ 50mA · 48VDC @ 50mA · 48VDC @ 50mA

Ask about the Bogen Telephone Interface Module (TEL1S)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bogen Telephone Interface Module (TEL1S)

Be the first to ask — other owners or our team will answer.

Original document

Bogen Telephone Interface Module (TEL1S) manual PDF

3 pages·108 KB·Communications·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…