Owner’s Manual EnglishPage 1 Mode d’emploi Français: Page 6 Manual de Uso Español: Página 11

This is a legacy product document supported by Resideo. It is no longer manufactured

Getting started

Check package contents:

Before you begin, make sure you have:

  • Thermostat
  • Large print subbase switch labels
  • Coverplate
  • Wall anchors & screws (2 each)
  • Wire labels Thermostat is for 24 Vac heating and cooling systems
  • No. 2 Phillips & small pocket screwdrivers
  • Hammer
  • Level (optional)
  • Pencil
  • Drill and bit (3/16” for drywall, 7/32” for plaster)

This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material—special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate

Remove your old thermostat

Honeywell Programmable Thermostat (CT87N) — Remove your old thermostat diagram (page 1)
Fig. 2 · Remove your old thermostat

Leave wallplate in place.

Is there a sealed tube containing mercury? If so, see mercury notice below.

Honeywell Programmable Thermostat (CT87N) — Remove your old thermostat diagram (page 1)
Fig. 3 · Remove your old thermostat

MERCURY NOTICE If your old thermostat contains mercury, contact your local waste management authority for proper disposal instructions.

7,159,790; 7,476,988 and other patents pending. Copyright © 2017, Honeywell International Inc.

All rights reserved.

Page 2 of the Honeywell Programmable Thermostat (CT87N) user manual — Mount thermostat base
Page 2 · click to enlarge
Page 2

TM • Owner's Manual

Label wires and remove old wallplate

Use a screwdriver to disconnect wires one by one. As you disconnect each wire, wrap it with the label matching the letter on your old thermostat. (Adhesive labels are supplied in your thermostat package.)

Remove the old wallplate only after all wires are labeled. Be careful not to let loose wires fall into the wall opening.

Wrap supplied labels securely around each wire.

Do not let wires fall into wall opening!

Honeywell Programmable Thermostat (CT87N) — Label wires and remove old wallplate diagram (page 2)
Fig. 4 · Label wires and remove old wallplate

IGNORE WIRE COLORS: Use only letter designations to identify wire types.

If your old thermostat has 7 or more wires (not counting terminals C or C1), you may have purchased the wrong replacement thermostat. Stop now and call 1-800-468- 1502 for advice.

Mount thermostat base

Honeywell Programmable Thermostat (CT87N) — Mount thermostat base diagram (page 2)
Fig. 5 · Mount thermostat base

CT87N Easy-To-See

Page 3 of the Honeywell Programmable Thermostat (CT87N) user manual — O
Page 3 · click to enlarge
Page 3
  • English: Page 1
  • Français: Page 6
  • Español: Página 11

Subbase and base installation

1. Pull wires through wire hole. Position coverplate on wall, level and mark hole positions.

Large-print subbase switch labels

2. Drill holes (3/16” for drywall, 7/32” for plaster) and tap in supplied wall anchors.
3. Pull wire through coverplate and subbase, position over anchors, then insert and tighten mounting screws. Check level if desired.
4. Apply the large-print labels to the coverplate, matching the labels on the subbase.

Wiring

1. Match each labeled wire with same letter on terminal.

E F

2. Use a screwdriver to loosen screw terminals, insert bare wire into slots, then tighten screws.
3. Push any excess wire back into the wall opening.

G

R

Labels don't match?

W Y B

If labels do not match letters on thermostat, see table below.

O

Existing wires Connect to:

  • RH
  • V Terminal “ R ” [1]

Rc Terminal “Rc” [1]

O Terminal “O” [2]

[1] If wires will be connected to both R and

Rc terminals, remove metal jumper.

B Terminal “B” [2]

G • F Terminal “G”

[2] Do not connect both O and B if you

  • W1
  • H Terminal “ W ”

have a heat pump. Connect only the O wire. Wrap B wire with electrical tape and do not use.

  • Y1
  • M Terminal “ Y ”
  • B Do not use [3]

[3] Do not use C, X or B. Wrap bare end of

wire with electrical tape.

[4] If you have two wires, connect wires to

R and W.

Subbase · Coverplate · Rc

Page 4 of the Honeywell Programmable Thermostat (CT87N) user manual — Thermostat mounting
Page 4 · click to enlarge
Page 4

TM • Owner's Manual

Fan operation settings

Move the switch to the proper setting for your system:

F: For gas or oil heating systems, leave the fan operation switch in this factory- set position (for systems that control the fan in a call for heat).

E

F

E: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.)

Cycle rate settings

Move the cycle rate switches to the proper setting for your system (see table below).

Heating System Switch 1 Switch 2

Steam or gravity On On

High efficiency warm air Off On (90% plus efficiency), hot water, or heat pump

Gas or oil warm air Off Off (factory setting)

Electric warm air On Off

Thermostat mounting

1. Align the slots on the base with tabs on the thermostat, then push gently until the thermostat snaps into place.
2. Restore electrical power at the heating/cooling system, or at the fuse/circuit-breaker panel.

CT87N Easy-To-See · Coverplate and subbase · Thermostat

Page 5 of the Honeywell Programmable Thermostat (CT87N) user manual — 1-year limited warranty
Page 5 · click to enlarge
Page 5
  • English: Page 1
  • Français: Page 6
  • Español: Página 11

Operation

  • System switch
  • Cool: Controls the cooling system.
  • Heat: Controls the heating system.
  • Off: All systems are off.
  • Fan switch
  • On: Fan runs continuously.
  • Auto: Fan runs only when heating or cooling

system is on.

Honeywell Programmable Thermostat (CT87N) — Operation diagram (page 5)
Fig. 6 · Operation

T

H

E

A

F

A

•

N

F

F

O

O

N

•

Markings Enlarged, raised num- bers indicate temperature range by touch or sight. The large 5, 6, 7 and 8 mean 50, 60, 70 and 80°F, respectively.

•

Temperature

O

•

A

setting

O

U

T

Rotate to set, a click is heard every two degrees as the tem- perature is adjusted.

O

Temperature Current indoor temperature.

1-year limited warranty

Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunc- tions, Honeywell shall repair or replace it (at Honeywell's option).

SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or conse- quential damages, so this limitation may not apply to you.

If the product is defective,

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HON- EYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURA- TION OF THIS WARRANTY. Some states do not allow limita- tions on how long an implied warranty lasts, so the above limitation may not apply to you.

(i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or

(ii) call Honeywell Customer Care at 1-800-468-1502. Cus- tomer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.

If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr., Golden Valley, MN 55422 or call 1-800-468-1502.

Honeywell's sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL

Ask about the Honeywell Programmable Thermostat (CT87N)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Honeywell Programmable Thermostat (CT87N)

Be the first to ask — other owners or our team will answer.

Original document

Honeywell Programmable Thermostat (CT87N) manual PDF

16 pages·3 MB·Thermostat·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…