Instruction/ maintenance manual of the product P408ICAT Broan
Go to page of 16
E64000 SERIES INTENDED FOR DOMESTIC COOKING ONL Y INST ALLER: LEA VE THIS MANU AL WITH HOMEO WNER. HOMEO WNER: USE AND CARE INFORMA TION ON P A GES 13 AND 14. Broan-NuT one LLC; Har tf ord, Wisconsin www .broan.com 800-558-1711 Broan-NuT one Canada; Mississauga, Ontario www .
W ARNING W ARNING - 2 - T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJUR Y TO PERSONS, OBSER VE THE FOLLO WING: 1. Use this unit only in the manner intended by the manuf acturer . If you hav e questions, contact the manuf acturer at the address or telephone number listed in the warranty .
HL0097 - 3 - RMP SERIES BA CKSPLASH (S T AINLESS S TEEL W ALL CO VERING WITH W ARMING SHEL VES . O PTIONAL .) 8” R OUND A DJUST ABLE E LBOW M ODEL 412 T RANSITION (3¼” X 10” TO 7”) A DAPTER /.
- 4 - HL009 8 RMP SERIES BA CKSPLASH (S T AINLESS S TEEL W ALL CO VERING WITH W ARMING SHEL VES . O PTIONAL ) E64000 SERIES HOOD - E64000 SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLO WERS 332KR.
- 5 - 1. SELECT BLOWER OPTION AND INST ALLA TION TYPE 1.2 D UCTED I NST ALLA TION The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blow ers (included with the hood), or hood using e xter nal blo wers.
- 6 - 2. PREP ARE THE INST ALLA TION Make sure that the f ollowing items are included: - Range hood - Accessories: • Baffle filters • Baffle filters handles (located inside the hood) • 3¼” x .
- 7 - 2. PREP ARE THE INST ALLA TION (CONT’D) Cut-out the openings f or duct ( A ) and power cab le ( B ), in cabinet or wall, according to the direction of discharge chosen.
- 8 - 4. REMOVE FIL T ERS AND GREASE DRIP RAIL A. Remov e tape on filters. Remov e filters from hood and set aside. NO TE: It is recommended to star t with the center one(s). B. Remov e tape on grease drip rail ( 1 ). Lift out grease drip rail and set aside.
- 9 - 6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONL Y) Remov e the knock out for the chosen opening(s) (horizontal at the bac k of the hood or vertical on top). See illustrations below . V ERTICAL DISCHARGE H ORIZONT AL DISCHARGE NO TE: F or ducted installation only .
- 10 - 7. HORIZONT AL DISCHARGE INST ALLA TION ( INTERNAL BLOWER(S) ONL Y) HD0271 Flip the blo wer and engage its flange in the back w all retaining brac ket. Using a 5/16” sock et and the screws pre viously remov ed, secure the blo wer to the hood.
- 11 - 10. INST ALL THE HOOD (ALL BLOWERS) HD0265 A B A B B INTERNAL BLO WER: Run power cab le to installation location. Place the hood in its location. Mar k the position of the scre ws (smaller par t of the ke y holes [ A ]) with a pen. Remov e the hood and install the (4) 1/2” doub le thread screws at marked positions , leaving a 1/8” gap.
- 12 - 13. INST ALL LIGHT BULBS This hood must use 120 V , 50 W , MR16 with GU10 base or P AR16 with GU10 base, shielded halogen lamps (not included). W ARNING In order to pre vent the risk of personal injury , do not install a lamp identified f or use only in enc losed fixtures.
- 13 - 15. USE AND CARE Baffle Filters The baffle filters should be cleaned frequently . Use a war m detergent solution. W ash more often if your cooking style generates greater grease—lik e fr ying foods or w ok cooking. Remov e baffle filters by pushing them to wards the back of hood and rotating filters do wnward.
- 14 - 16. OPERA TION (CONT’D) HC00 3 5 1) Halogen light knob 2) Blower operation indicator 3) ON/OFF blow er switch 4) Blower speed control knob 2 3 1 4 HC00 3 4 A) Halogen light knob B) Blower speed control knob A B COOKT OP LIGHTING (HALOGEN) A rotar y 3-position knob ( 1 ) controls the halogen lights (OFF - low intensity - high intensity).
- 15 - 18. WIRING DIAGRAMS Broan Elite E64000 Series Internal blower hoods Broan Elite E64000 Series Exterior or In-Line blower hoods LINE NEUTRAL GROUND 120 V AC WHT M BRN BLU RED BLK M BRN BLU RED B.
- 16 - 19. SER VICE P ARTS HL0104 Broan Elite E64000 Series Internal blower hoods Broan Elite E64000 Series Exterior or In-Line blower hoods 6 7 14 17 * N OT SHO WN .
An important point after buying a device Broan P408ICAT (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Broan P408ICAT yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Broan P408ICAT - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Broan P408ICAT you will learn all the available features of the product, as well as information on its operation. The information that you get Broan P408ICAT will certainly help you make a decision on the purchase.
If you already are a holder of Broan P408ICAT, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Broan P408ICAT.
However, one of the most important roles played by the user manual is to help in solving problems with Broan P408ICAT. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Broan P408ICAT along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center