
BASIC 200
OWNER’S MANUAL



DO NOT OPEN FROM VERTICAL POSITION. THIS
CAN DAMAGE BASE.
TESTED AND INSPECTED THIS PRODUCT PRIOR TO SHIPMENT.
RADIO FREQUENCY IS 2.4Ghz. This device complies with part 15 of the FCC Rules and Industry Canada’s license exempt RSSs. Operation is subject to the following two conditions:
Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void the user’s right to operate the device. The input voltage is AC100-240 50/60HZ; the output voltage is DC29V 1.8A.
ELECTRICAL SAFETY Always unplug this adjustable bed from the electrical outlet before any cleaning or maintenance of the adjustable bed. To safely disconnect, remove the plug from the outlet. Keep cord away from heated surfaces. Use only indoors.
Discontinue use of this adjustable bed and contact the manufacturer for repair if:
FOR OPTIMAL SAFETY, YOUR ADJUSTABLE BED SHOULD BE PLUGGED INTO A SURGE PROTECTOR (not supplied with this adjustable bed).
BATTERY PRECAUTIONS Follow these precautions when using batteries in this device:

WARRANTY WARNING! This bed is specifically designed to require no maintenance by you, the user. Any opening or tamper- ing with the control box, motors or hand controls (with the exception of the battery compartment, if equipped) will void the warranty. Do not attempt to alter component wiring or adjust or modify the struc- ture of the product in any way or the warranty will be void. Only those authorized may conduct repairs or part replacement on your adjustable bed.
IN-HOME USE ONLY This adjustable bed is designed exclusively for in-home use.
HOSPITAL/COMMERCIAL DISCLAIMER This base is NOT designed for commercial or hospital use and is NOT designed to meet hospital standards. Do not use this base with TENT TYPE oxygen therapy equipment or use near explosive gases.
PRODUCT RATINGS Lift Motor Restrictions: The lift motors in this bed are NOT designed to operate continuously for more than one (1) minute over a nine (9) minute time period, or approximately 12% duty cycle. To ensure reliable functionality and full life of this product, do not attempt to exceed these limits. NOTE: Attempting to circumvent or exceed this rating will shorten the life expectancy of the product and may void the warranty.
across the bed.
the bed in the flat position is recommended.
and void your warranty.

SMALL CHILDREN AND PETS WARNING Immediately dispose of all packing materials, as they can pose a smothering risk to small children and pets. Injury could also occur if children or pets are permitted to play on or under the bed. Do not allow children to operate this bed without adult supervision.
LUBRICATION AND CLEANING This product is designed to be maintenance free. The lift motors are permanently lubricated and sealed—no additional lubrication is required. Do not apply lubricant to lift motor lead screws or any nylon nuts or the base may inadvertently creep downward from the elevated position.
LIFT WARNING DO NOT SIT ON THE HEAD OR FOOT SECTIONS WHILE IN THE RAISED POSITION, OR DURING LIFT OR LOWERING CYCLES.
MOVING AFTER INSTALLATION Do not place adjustable bed base vertically on its head or foot sections. This may cause injury to persons or damage to base.
disabled persons, or pets.
Do not use attachments not recommended by the manufacturer.
has been dropped or damaged, or dropped in water.
FOR HOUSEHOLD/RESIDENTIAL USE ONLY.

Before discarding any packing materials, check the adjustable base shipping carton and verify the following items are included:
B C
(1) Remote Control (1) Power Supply
F
(1) Foot Mattress Retainer
(1) AC Power Cord
(2) C-Clips (2) Hinge Pins
for use with TXL, SCK, SQ models only

USE 2 PEOPLE TO LIFT BASE TO AVOID DAMAGE.

It is HIGHLY recommended to use two people for the installation of this product. To assemble, please perform the following steps:
Carefully lift the base from the shipping carton, keeping the unit’s topside down. Remove the plastic wrapping from the bottom to access the bases.
Lay base flat and unfold topside down.
Lay the base flat before unfolding base.
Insert hinge pins and secure with retaining clips. Repeat on both sides of base.
If installing on a platform base or foundation, do not install legs. Follow the instructions included in the MULTIFUNC- TION BRACKET accessory kit.
Insert all 6 legs into the threaded holes and securely tighten before turning base over for use. There must not be any gap or wobble in the leg in order to avoid risk of injury or dam- age to the base which may void warranty.


Insert DC cord from base into the power supply.
Carefully rotate the base on its side, then lift and place on legs.
DO NOT TILT or LEAN base on the installed legs when turning base over.


Insert the mattress retainer bar upright as shown.

Lift the battery cover and insert the two AAA size batteries (included) into the remote as shown in the figure. Replace the battery cover. Remote is already linked with the base.

Turn the power supply upside down to access the battery cover, then slide the battery cover off.
Insert the two 9V batteries (included) into the compartment and slide the cover back on.
Insert AC plug into an AC outlet having 100-240V AC, 50/60Hz. Avoid outlets that work only with light switch.



Press and hold the HEAD UP button to raise the head position. Release button when desired position is reached.
Press to return base to FLAT position from any combination of HEAD UP and / or FOOT UP.

Press and hold the FOOT UP button to raise the foot position. Release button when desired position is reached.
Press and hold the FOOT DOWN button to lower the foot position. Release button when desired position is reached.
Press and hold the HEAD DOWN button to lower the head position. Release button when desired posi- tion is reached.

Press and hold FLASHLIGHT button to activate LED flashlight on top of remote.
Adjust head and/or foot sec- tion(s) to desired positions. Press and hold MEMORY (M) button until the backlight on remote flashes. Release button and wait for flash to stop. Button has now been programmed. Repeat pro- cess if new preset position is desired.


Double click the PAIR button on the control box (light will turn blue during the pairing process).
Simultaneously press and hold the HEAD UP and HEAD DOWN buttons on remote until the remote back lights blink, then release remote buttons.
If SYNCING 2 bases (TXL, SCK, SQ) together, follow these instructions.
With both bases in FLAT position, connect each base to the other by inserting SYNC CABLE into each control box slot labeled sync.

In the event the base fails to operate, investigate the symptoms and possible solutions provided below:
Remote control illuminates and appears to be operable, but no features of the base will activate.
working appliance.
No features of the base will activate.
working appliance.
Remote control will not illuminate.
Head section will elevate, but will not return to the horizontal (flat) position.
brackets and mattress is sufficient. Adjust if required.
Head or Foot Lift Function has minor interference during operation.
one (1) minute over a nine (9) minute period, or approximately a 12% duty cycle).
radio transmitting devices (see Pairing Remote section).



Raises height of base to 19” for TXL, F, Q,


NO LEG INSTALLED 3 1/2”
STANDARD LEG PROVIDED 15”
HIGH PROFILE 19”
OPTIONAL 3-IN-1 LEG
ALL LEG SECTIONS INSTALLED 14”
TWO LEG SECTIONS INSTALLED 10 1/2”
ONE LEG SECTIONS INSTALLED 7”

SLEEP WELL. LIVE BETTER. BE YOUR BEST.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.