Installation & Operation

Serial No. GB_V2_Manual.



READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT If unable to understand warnings, cautions, and/or instructions, contact the dealer or technical personnel
if applicable, before attempting to use the equipment. Otherwise, injury or damage may result.
SAFETY WARNINGS: • Do not use bed outdoors.
Product Rating: The motors are not designed to operate continuously for more than [2] minutes in an [18] minute time period or approximately 10% duty cycle. Attempting to circumvent or exceed this rating will shorten the life expectancy of the foundation and may void the warranty.
and secure oxygen or air tubing properly to ensure that tubing does
not become entangled or damaged during normal operation of the
bed.
spilling occurs. In case of spillage, stand in a dry, clean area of the
area around bed to dry thoroughly before using the electric controls
again. Do not eat or drink hot liquids while operating the bed.
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
not approved for hospital use and does not comply with hospital standards.
supervision or instructions concerning use of the appliance by a
person responsible for their safety.
Weight Limits: This product is not rated to support weights in excess of 750 pounds inclusive of the mattress and bedding. The bed will structurally support this weight, provided it is evenly distributed across the foundation. The power foundation is not designed to support or lift this amount in the head or foot sections alone. Exceeding this weight restriction could damage the bed and/or cause injury and will void the warranty.
bed without adult supervision.
bed when operating bed functions.

exception of battery compartments). The warranty will be void if the
internal workings of these components are tampered with.
FCC COMPLIANCE:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
To comply with the FCC RF exposure requirements, no change to the antenna or the device is permitted. Any change to the antenna or the
device could result in the device exceeding the RF exposure requirement and void user’s right to operate the device.


All electronics and components that need to be installed are located in boxes under the foundation or attached to the frame. Before discarding the packing materials, ensure that all the parts are accounted for.





Lower the head and foot frame pieces with their top side facing downward.
Using a pair of scissors (not included), cut the ties to remove all accessory boxes and retainer bar from inside the unit.

Attaching the bed legs
Remove the six (6) bed legs from the accessory box. Hand tighten the legs by threading them clockwise into the pre-threaded holes on the bed frame.




Turn the bed frame over carefully, top side up.
Insert the ends of the retainer bar into the quick connect brackets located at the foot of the bed.

Setting up the electronics

Take out the power supply and the power cord from the accessory box.
Connect the power cord from the control box to the power supply.

Connect the power cord that was packaged with the power supply to the power supply.

Plug the power cord into a working electrical outlet. The LED lights under the base will flash for 10 seconds.


Install the two (2) AAA batteries into the remote control.
Confirm the remote control works by pressing the lift buttons. Installation for single or independent operation of the bed frame is now complete.


The button will let you choose between the 3 massage settings.

The wireless power bed has a programmable feature that allows you to save custom positions. Please read all the instructions below before setting your custom presets on the remote.
Adjust the head and foot to your desired position.


To adjust the saved position, repeat steps 1 and 2 and the new position will be saved.
The original remote that comes in the box is already paired to the foundation. No further action is required. In the event that the remote is not paired with the foundation, follow the steps below.



Press the “PAIR”button located on the side of the control box
2 times and then press the “PAIR” button located on the remote.

Your adjustable bed frame comes with a power supply that, when powered with two new 9V batteries, supports the emergency power down feature.The batteries are not included and work for a single use only.
If a power failure occurs while the head and/or foot sections are raised, do the following:

Install two (2) new 9V batteries in the battery compartment of the power supply.
Press the flat position on the remote if there is no power from the electrical outlet.

If simultaneous operation of two foundations is desired, please read the instructions.
Plug A and B bases to power source.
Plug the synchronizing cable into 2 control boxes of 2 bases.

Then base A and base B can be simultaneous operated by Remote A.
Remark :If you don't need Synchronizing just remove the Synchronizing cable.
be able to operate both beds simultaneously. Note: been separated from the remote A.

Headboard brackets are an optional accessory and are not included. A 1/2'' (13 mm) socket and 1/2'' (13 mm) crescent wrench are necessary to complete installation.
(2) Headboard Brackets (2) T-Brackets (4) Short Bolts (12) Nuts (8) Long Bolts





The headboard bracket will have 2 long slots to accomodate any frame type. Align the appropiate slots on the bracket with the holes on the bed. Use long bolts and nuts to secure the bracket. Make sure the bolts are tight.
To put the T-Bracket and Headboard Bracket together, you will need (2) short bolts and (2) nuts. Slip the bolts through the holes from T-Bracket to Headboard Bracket with the head of bolt facing outward. Use 1/2'' (13mm) socket and 1/2'' (13mm) wrench to tighten the bolts.


You may now connect your headboard to the attachment plates using the remaining short bolts and nuts to secure it to the brackets. The heads of the bolts will face outward. Use a 1/2" (13 mm) socket and 1/2" (13 mm) wrench to tighten the bolts.

In the event that the power foundation fails to operate, assess the symptoms and possible solutions
provided in the chart below.
Verify that the power cord is plugged into a working, grounded electrical outlet. Test the outlet by plugging in another working appliance.
Remote control illuminates and appears to be operable, but will not activate bed.
Program the remote control (see the Setting Programmable Positions and Pairing Remote section of this manual for programming procedures).
Unplug the power cord, wait 30 seconds and plug back to reset electronic components.
No features of the power foundation will activate.
The surge protection device or the electrical outlet may be defective. Test the outlet by plugging in another working appliance.
Verify that the connector on the wired remote control is securely attached to the control box.
Wireless remote will not illuminate. Replace the batteries in the wireless remote.
Bed mechanism may be obstructed. Elevate bed and check for obstruction. Remove obstruction.
Head or foot section will elevate, but will not return to the horizontal
Head section may be too close to the wall.
Headboard may be too close to the edge of the mattress. Verify that there is enough distance between the headboard brackets and mattress. Adjust if required.

In the event that the power foundation fails to operate, assess the symptoms and possible solutions
provided in the chart below.
Check batteries in wireless remote control, replace with two (2) new AAA batteries if necessary.
Make sure that you are following the duty cycle of the motors (do not operate more than two minutes over a 18-minute period, or approximately 10% duty cycle).
Head & Foot lift function has minor interference durling operation.
Press the lift buttons squarely and accurately.
Wireless remote control may be experiencing common Radio Frequency Interference from other radio transmitting devices. Wait several seconds, and then try pressing appropriate button again, See FCC Compliance Statement on page 1 of this guide.
This is normal. The lift motor relays “click” when they are engaged. No action is required.
A clicking noise is heard under the bed when raising or lowering.

If you have had any issues with the assembly process, you can contact GhostBed Customer Service by calling 855-855-4499; email sales@GhostBed.com;


Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Remote control illuminates and appears to be operable, but will not activate bed. | Verify that the power cord is plugged into a working, grounded electrical outlet. Test the outlet by plugging in another working appliance. | p.14 | |
| No features of the power foundation will activate. | Program the remote control (see the Setting Programmable Positions and Pairing Remote section of this manual for programming procedures). Unplug the power cord, wait 30 seconds and plug back to reset electronic components. The surge protection device or the electrical outlet may be defective. Test the outlet by plugging in another working appliance. Verify that the connector on the wired remote control is securely attached to the control box. | p.14 | |
| Wireless remote will not illuminate. | Replace the batteries in the wireless remote. | p.14 | |
| Head or foot section will elevate, but will not return to the horizontal | Bed mechanism may be obstructed. Elevate bed and check for obstruction. Remove obstruction. Head section may be too close to the wall. Headboard may be too close to the edge of the mattress. Verify that there is enough distance between the headboard brackets and mattress. Adjust if required. | p.14 | |
| Head & Foot lift function has minor interference durling operation. | Check batteries in wireless remote control, replace with two (2) new AAA batteries if necessary. Make sure that you are following the duty cycle of the motors (do not operate more than two minutes over a 18-minute period, or approximately 10% duty cycle). Press the lift buttons squarely and accurately. Wireless remote control may be experiencing common Radio Frequency Interference from other radio transmitting devices. Wait several seconds, and then try pressing appropriate button again, See FCC Compliance Statement on page 1 of this guide. | p.15 | |
| A clicking noise is heard under the bed when raising or lowering. | This is normal. The lift motor relays “click” when they are engaged. No action is required. | p.15 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.