SmartCode at a Glance Normal Operation Normal Operation Z-Wave & ZigBee Systems
B C
Lock Inclusion
Use the chart to determine which button to press during Inclusion and Exclusion.
Option 1 Touch screen with palm or back of hand until digits illuminate.
Option 2 Touch lower left area of screen (where checkmark is located) until digits illuminate.
Option 3 Touch screen with three or more fingers until digits illuminate.
1 Activate the screen. 2 Press Lock symbol. Note: If no user codes are programmed, the door cannot be locked via touchscreen.
“Inclusion” refers to the process in which the lock is added to a Z-Wave or ZigBee controller.
Initiate the Inclusion process at your ZigBee or Z-Wave controller. Refer to your control system instructions for more information.
User Guide
If Inclusion is unsuccessful, perform the Exclusion process. Then repeat the Inclusion process. If Inclusion is still unsuccessful, consult the online Troubleshooting Guide, available on the SmartCode 916 page of www.kwikset.com
SecureScreen ™ Unlocking the Door
System Notes
1 Activate the screen. 2 If SecureScreen™ is enabled, touch the random digits that appear. 3 Enter user code.
SecureScreen is an added-security feature that displays random digits before you enter a user code to unlock the door. This feature ensures that there are fingerprints on all digits so that codes cannot be identified by examining the touchscreen for fingerprints.
Lock Exclusion “Exclusion” refers to the process in which the lock is removed from a Z-Wave or ZigBee controller. Initiate the Exclusion process at your Z-Wave or ZigBee controller. Refer to your control system instructions for more information.
In order to fully utilize this product, you must have a Z-Wave controller compatible with door locks. Z-Wave is a “Wireless mesh network,” and results may vary based on building construction and communication path, with 35 feet+ being typical installed distance from network controller. It may be necessary to install additional Z-Wave beaming capable devices that can serve as repeaters to enhance the communication path between the lock and controller for a more robust Z-Wave network.
ZigBee is a “Wireless mesh network,” and results may vary based on building construction and communication path, with 35+ feet being typical installed distance in a standard home environment and 250 feet+ when the lock has a clear line of sight with the network controller. It may be necessary to install additional ZigBee devices to enhance the communication path between the lock and controller for a more robust ZigBee network.
Installation instructions are located on the reverse side
If desired, this feature can be disabled by turning switch #4 to the off position.
turnpiece shaft can be used to manually lock and unlock the door.
of this document.
If you press the wrong digit while entering a user code, you can press the Lock symbol once to clear the digits entered previously and immediately restart the code entry process.
Programming Codes
a Programming Information Enabling and Adding a Mastercode (Optional for Enhanced Security)
e Deleting a Single User Code
b
d Adding User Codes
f Deleting All User Codes
User codes can be programmed with or without a mastercode. Using a mastercode is an optional, added-security measure. It is not enabled by default. A mastercode is used to add and delete user codes, but it cannot unlock the door (unless the same code is programmed as a user code, though this is not recommended). The mastercode must be 4-8 digits.
This procedure can only be performed if the mastercode is enabled. Note: The Auto-Lock feature (switch #2) will be disabled if all codes are deleted.
It is recommended that you add and delete all user codes through your Z-Wave or ZigBee control system. If your system does not allow this, the following sections will provide instructions for how to add and delete codes at the lock.
Keep door open.
Keep door open. Press Program button once.
Keep door open.
Keep door open. Press Program button once.
Press Program button once.
Press Program button once.
Press Checkmark symbol once. Keep door open.
You will hear five beeps and the checkmark will flash five times.
2 Press Checkmark symbol once.
Press Checkmark symbol once.
Press Checkmark symbol once.
Each user code must be a unique code between 4 and 8 digits, depending on your control system. A total of 30 user codes may be programmed.
Press Lock symbol once.
(the code that was enabled in section b)
Press Lock symbol once.
Enter USER code.
Enter new USER code.
Successful Programming The Checkmark symbol will illuminate and you will hear one beep*.
If the screen is not pressed for 20 seconds, the system will time out, and you will need to restart the procedure.
Enter new USER code.
Press Lock symbol once.
Press Lock button once.
Press Lock symbol once.
Re-enter USER code.
Unsuccessful Programming The “X” pattern will fl ash three times, and you will hear three beeps*.
Press Lock symbol once.
Make sure the user code not a duplicate and that it is between 4 and 8 digits during your next attempt.
Make sure the user code not a duplicate and that it is between 4 and 8 digits during your next attempt.
Make sure the lock has room for an additional code. If all user code positions are filled, delete a code to make room for this one.
Make sure the lock has room for an additional code. If all user code positions are filled, delete a code to make room for this one.
Make sure to enter a valid mastercode in step 3.
Make sure to enter the same valid code in steps 4 and 6.
Programming Timeout If the screen is not pressed for 20 seconds, the system will time out (indicated by three beeps* and the “X” pattern fl ashing three times), and you will need to restart the procedure.
TEST CODE
While the door is open and locked, test the user code to make sure it unlocks the door.
While the door is open and locked, test the user code to make sure it unlocks the door.
While the door is open and locked, test the user code to make sure it no longer unlocks the door.
If the screen is not pressed for 20 seconds, the system will time out, and you will need to restart the procedure.
If the screen is not pressed for 20 seconds, the system will time out, and you will need to restart the procedure.
If the screen is not pressed for 20 seconds, the system will time out, and you will need to restart the procedure. If the screen is not pressed for 20 seconds, the system will time out, and you will need to restart the procedure.
*Beeping sound will only be heard if switch #3 is on.
Important Safeguards
This product complies with standards established by the following regulatory bodies:
does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
A factory reset will delete all codes associated with the lock. If needed, the door handing process can be initiated manually. This is useful if the lock is being moved to a different door.
Remove battery pack. Press and HOLD the Program button while reinserting the battery pack.
Remove battery pack. Press and HOLD the Program button while reinserting the battery pack. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: ( 1 ) this device may not cause harmful interference, and ( 2 ) this device must accept any interference received, including interference that may cause undesired operation.
Release button once battery pack is installed. The status LED will flash red and green.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment
4 The latch bolt will extend and retract to learn the orientation of the door.
4 5 After a few seconds, the lock will initiate the door handing process, and the latch bolt will extend and retract to learn the orientation of the door.
Press the Program button once more.
Press the Program button once more. The status LED will flash green and red several times.
Perform the Inclusion process again to add the lock back into your network and controller.
WARNING: This Manufacturer advises that no lock can provide complete security by itself. This lock may be defeated by forcible or technical means, or evaded by entry elsewhere on the property. No lock can substitute for caution, awareness of your environment, and common sense. Builder’s hardware is available in multiple performance grades to suit the application. In order to enhance security and reduce risk, you should consult a qualifi ed locksmith or other security professional.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: ( 1 ) this device may not cause interference, and ( 2 ) this device must accept any interference, including interference that may cause undesired operation of the device.
If the touchscreen indicates
a failure, see the online
Troubleshooting guide.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.