EXEC™ Operating Instructions

  • Accuracy to ±0.9°F (±0.5°C)
  • 3-4 second readings
  • –40 to 572°F range
  • Calibration trim
  • IP67 rating
  • 180° rotating display
  • Backlight
  • Max/Min function
  • NIST-traceable certificate
ThermoWorks Needle Thermometer (EXEC) — EXEC™ Operating Instructions diagram (page 1)
Fig. 1 · EXEC™ Operating Instructions

Instrument Operation Press the power button to activate the thermometer. The unit will turn off automatically after 35 minutes to save battery life. Press and hold the power button for 3 seconds to turn off EXEC. To activate the backlight, press the power button once while the instrument is turned on. Press again to turn off.

Insert the stainless steel probe to the desired depth. The measured temperature will be shown on the LCD display within 3 to 4 seconds.

Using MIN/MAX Press the MAX/MIN button to read the last highest / maximum temp measured. Press once more to read the last lowest / minimum temperature measured. Press once more to return to normal display. Press and hold the MAX/MIN button for three seconds then release to reset the memory. MAX and MIN are reset when the unit is powered off.

Battery Installation Replace the battery when low battery symbol ‘Bat’ flashes. Replace with a 3 volt, type CR1632, button-cell battery or equivalent. Use a screwdriver of suitable size to open the battery cover on the back. Install the battery observing the correct polarity, (+) positive side up, sliding the battery under the metal clip. Close the battery cover.

To Select ˚F or ˚C Press the °C/°F button on the back of the thermometer to select the desired temperature unit.

Calibration Trim New from the factory EXEC should read within ±0.9°F. Normally a calibration adjustment should never be needed. For instructions on performing a one-point calibration trim go to the EXEC webpage at www. thermoworks.com.

Care and Cleaning Clean the probe immediately after each measurement to avoid cross contamination. Do not expose the thermometer body to temperatures over 122°F (50°C). Do not leave inside ovens. Avoid submersing the entire thermometer.

Technical Support For warranty, service, and technical assistance, please contact ThermoWorks’ Technical Support at (801) 756-7705 or email at techsupport@thermoworks.com.

For additional cooking tips and doneness temperatures, and to see the full line of ThermoWorks tools, visit our website at www.thermoworks.com

–40 to 572°F (–40 to 300°C) ±0.9°F (±0.5°C) between 14 to 212°F (–10 to 100°C), ±4.5°F (±2.5°C) between 392 to 572°F (200 to 300°C) otherwise ±2.7°F (±1.5°C) 0.1° °C/°F Approx. 3-4 seconds from ambient to 32°F ±0.9°F After 35 minutes 0.45 H x 0.94 W inches (11 H x 24 W mm), automatically rotates 180° 10 seconds 0.29 H x 0.16 W inches (7.5 H x 4.0 W mm) 4.8 L x 0.1 dia. inches; reduces to 0.67 L x 0.06 (1/16") dia. inches (125 L x 2.5 dia. mm; reduces to 17 L x 1.5 dia. mm), Thermistor Approx. 0.25 inch (6.4 mm) IP67 3 volt, type CR1632 or equivalent x 1 piece (included) 3,000 hours continuous use 8.3 H x 0.9 W x 0.6 D inches (211.5 H x 23 W x 16 D mm) 32 to 122°F (0 to 50°C)

Page 2 of the ThermoWorks Needle Thermometer (EXEC) user manual — Poach 160-180°F 71-82°C
Page 2 · click to enlarge
Page 2

Chef-Recommended Temps

Beef, Veal & Lamb Roasts, Steaks & Chops

Med. Rare 130-135°F * 54-57°CMedium 135-145°F * 57-63°CMed. Well 145-155°F * 63-68°C USDA-Done 145°F * 63°C

Pork Roasts, Steaks & Chops

BBQ Brisket, Ribs, & Pork Butt

* These temperatures are ideal peak temperatures. Meats should be removed from heat several degrees lower and allowed to rise during resting. ** Chef-recommended temperatures are consistent with many expert sources for taste and safety. USDA-recommended temperatures are 5 to 10°F (2 to 5°C) higher.

Minimum Done Temps for Food Safety

Ground Meat: Beef, Veal, & Sausage*

160°F 71°C Chicken, Turkey & Duck (whole or pieces)

165°F 74°C

*

Ham (raw) 160°F 71°C Poultry Dark Meat** 175°F 79°C

Ham (pre-cooked) 140°F 60°C Stuffing (in the bird) 165°F 74°C

Egg dishes 160°F 71°C Tuna, Swordfish & Marlin**

125°F 52°C

Casseroles & Leftovers 165°F 74°C Other Fish** 140°F 60°C

Water Temps (at sea level)

Simmer185°F 85°C Slow Boil 205°F 96°C Rolling Boil212°F 100°C

Poach 160-180°F 71-82°C

Low Simmer 180°F 82°C

Other Food Temps

Bread: Rich Dough 190-200°F 88-93°C Butter: Chilled 35°F 2°C

Bread: Lean Dough 200-210°F 93-99°C Butter: Softened 60-67°F 16-19°C

Water temp to add active dry yeast

105-115°F 41-46°C Butter: Melted & Cooled

85-90°F 29-32°C

Candy or Sugar Syrup Temps (at sea level)

Thread230-234°F (110-112°C)Syrup Soft Ball 234-240°F (112-116°C) Fondant, Fudge & Pralines Firm Ball244-248°F (118-120°C)Caramels Hard Ball 250-266°F (121-130°C) Divinity & Nougat Soft Crack270-290°F (132-143°C)Taffy Hard Crack 300-310°F (149-154°C) Brittles, Lollipops & Hardtack Caramel320-350°F (160-177°C)Flan & Caramel Cages
ThermoWorks Needle Thermometer (EXEC) — Poach 160-180°F 71-82°C diagram (page 2)
Fig. 2 · Poach 160-180°F 71-82°C

For service or warranty:

www.thermoworks.com 741 E. Utah Valley Dr. American Fork, UT 84003

1-800-393-6434 1-801-756-7705 techsupport@thermoworks.com

Show 8 more labels / short text on this page
** · Rare 120-130°F 49-54°C · Well Done · 155°F-up 68°C-up · Well Done · 150°F-up 66°C-up · Done 190-205°F 88-96°C · P-20-010-02-a
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the ThermoWorks Needle Thermometer (EXEC)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the ThermoWorks Needle Thermometer (EXEC)

Be the first to ask — other owners or our team will answer.

Original document

ThermoWorks Needle Thermometer (EXEC) manual PDF

2 pages·71 KB·Thermometer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…