Wireless Gate Entry Intercom
Installation Instructions
Crystal clear two-way wireless communication up to 500 feet
Thank you for purchasing the Mighty Mule Wireless Gate Entry Intercom.
Please read the directions carefully and completely before installing.

NEVER install the keypad portion of this system where a person can reach through the gate to activate it, or where a person can touch the gate while activating the keypad.
The recommended minimum distance between the gate and keypad is 10 ft.
©2010 GTO - Gates That Open, LLC

The Wireless Intercom/Keypad has two separate units: the KEYPAD and the BASE UNIT. The keypad should be mounted outside the gate allowing visitors to press the CALL button from their vehicle. The base unit is powered by a rechargeable battery; the charge is maintained by the transformer. It can also be disconnected from the transformer allowing it to go anywhere within range for convenience. Up to three additional base units can be added for convenience in different locations throughout the house.
When someone without an access code approaches the gate, they can press the CALL button on the keypad which will ring the base unit inside the house. To answer the CALL, the person inside presses and holds the ANSWER button to talk to the person at the gate, releasing the ANSWER button to listen. To allow the person calling to open the gate, the GRANT PERMISSION button must be pressed. Then the person at the gate can press any number key on the keypad to open the gate. The END CALL button terminates the calls and the ON/OFF switch can be used to conserve power when using unit on battery (note: the base station will not recieve a signal if turned OFF).
Up to 25 different personal Entry Codes may be programmed into the keypad, allowing you to give different temporary and permanent Entry Codes to different users. For example, you can give a delivery person their own temporary entry code, which you can easily change after he has made the delivery. This will prevent him from being able to regain access, while still allowing those to whom you gave permanent Entry Codes full access.
After entering a valid code, pressing any key on the keypad while the gate is opening will stop the gate; pressing any key while the gate is stopped will cause the gate to reverse direction. The keypad will not affect the auto-close setting of your gate opener system.
The keypad will light up and the unit will beep at the press of any key. The keypad memory will recognize your entry code in a string of up to 20 digits. If it finds the correct sequence, it will activate the gate opener. As a security feature, the keypad will shut down for 40 seconds if it does not find the correct code sequence within a 20-digit string. This will discourage an unauthorized person from trying to use random numbers to access your property.
Entry Codes will remain stored in memory even when the batteries go dead. The keypad will remember your Entry Codes as long as you don’t press the RESET button.
FCC WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
The contents of all material available on this installation manual are copyrighted by Gates That Open, LLC (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO
publications is by permission only. Copyright infringement is a violation of federal law.
GTO®, GTO/PRO®, Mighty Mule® are registered trademarks of GTO - Gates That Open, LLC. GTO Access Systems™ is a trademark of GTO - Gates That Open, LLC. These marks are the
exclusive property of GTO - Gates That Open, LLC (“GTO”). All rights are reserved by GTO, and these marks may not be used, in any form, without the prior, written permission of GTO.


CALLING Light: LED is RED when calling and turns GREEN when call is answered.
DIP Switches: Match the keypad dip switch settings with your entry transmitter’s dip switch settings.
1 2 3 4 5 6 7 8 9
GRANTED Light: LED turns GREEN when access permission is granted.
Power Input: Used to connect keypad to gate opener battery for continuous power supply.
1 2 ABC 3 DEF
4 GHI 5 JKL 6 MNO
PROGRAM button: Used to program entry codes.
Relay output: Used to connect the keypad to gate opener control board in hard-wired applications.
STATUS Light: This LED will blink once when any key is pressed and provides visual feedback when programming entry codes.
CALL
RESET button: Pressing this button for 2 seconds will reprogram the keypad to factory settings. All codes are deleted. Default Master Code is “1234.”
ID SET button: Used to reassign new code only when there is another pair of GTO wireless intercom units nearby causing interference.
Four (4) AA batteries (not included) are required to power the keypad. If an external DC power supply such as the gate opener’s battery is used (see 2.B.“Hard-Wired Installation”), the AA batteries will act as a back up.
Battery Holder: Use 4 AA batteries.

For wireless applications, the keypad must be in the line of sight of the gate opener receiver and no more than 50 ft. away from the receiver. Always test the keypad range before permanently mounting it. NOTE: a metal housing or metal object
could cause interference.

1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
B. Hard-Wired Installation To power the keypad with the gate opener’s battery and hard wire the communication between the keypad and the gate opener, you will need to run two pairs of wires: one pair to hard-wire the keypad to the gate opener’s control board; the other pair to connect the keypad to the gate opener’s battery.
Determine how the wires will enter the keypad (e.g., from the back through a hole drilled in the post; running the wire on the post surface). Remove the small rectangular knock-out on the back of the keypad housing and pull the wires into the housing. Then mount the housing to the post using the screws provided.
Knock-out


1 2 3 4 5 6 7 8 9
keypad control board (ON) as shown.
Power Supply from Opener Battery #1 #2
Hard-wire from Gate Opener
1 2 ABC 3 DEF
4 GHI 5 JKL 6 MNO
7 PRS 8 TUV 9 WXY
STATUS PROGRAM
CALL
Control Board Connections If your control board doesn’t look like any of these diagrams, please refer to your gate opener installation manual or call GTO Technical Service at 1-800-543-1236 or 850-575-4144.
PRO-1000/2000, PRO-SL1000/SL2000 and Old Mighty Mule Control Boards
Mighty Mule 350 Control Board
ON
GRN
ORG
BLU
WHT
R B G
LINK
EXIT
SAFETY
EDGE
CYCLE
COMMON
GRN
BLK
RED
ALARM ACCESSORY RCVR
RECR
Connect #1 wire from the RELAY OUTPUT terminals on the keypad to CYCLE terminal on the gate opener control board.
Connect #2 wire from the RELAY OUTPUT terminals on the keypad to the COMMMON terminal on the gate opener control board.
Connect #2 wire from the RELAY OUTPUT terminals on the keypad to the GRN terminal on the gate opener control board.
Connect #1 wire from the RELAY OUTPUT terminals on the keypad to WHT terminal on the gate opener control board.
GEN-3 (Blue) Control Boards
Mighty Mule 500 & 502 Control Boards
RECEIVER
COM COM
CYCLE
CLOSE
SAFETY
SHADOW
CLOSE
BLK GRN RED
EXIT/
OPEN
LOOP
EDGE
OPEN
EDGE
RECEIVER
COM
COM
CYCLE
SAFETY
EXIT
SHADOW
CLOSE
EDGE
OPEN
EDGE
ALM
GRN
BLK
RED
Connect the #2 wire from the RELAY OUTPUT terminals on the keypad to one of the COMMON terminals on the opener control board. #1 #2
Connect the #1 wire from RELAY OUTPUT terminals on the keypad to the CYCLE terminal on the opener control board.
GTO RCVR.
Connect #2 wire from the RELAY OUTPUT terminals on the keypad to the COM terminal on the gate opener control board. #1 #2
Connect #1 wire from the RELAY OUTPUT terminals on the keypad to CYCLE terminal on the gate opener control board.
GTO/PRO DC Powered PRO-SW3000 and PRO-SW4000 Control Boards
GTO/PRO GP-SL100 and GP-SW100 Control Boards
GTO Inc.
COM
COM
COM
J11 J11 J8 J12
CYCLE
SAFETY
SHADOW
LOOP
OPEN EDGE
RUN 2
OPEN
CLOSE
STOP
COM
COM
COM
CYCLE
CLOSE CYCLE
CLOSE
SAFETY
OPEN
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
COM COM
EXIT
GRN BLK RED
RECEIVER
Connect #1 wire from the RELAY OUTPUT terminals on the keypad to CYCLE terminal on the gate opener control board.
Connect #2 wire from the RELAY OUTPUT terminals on the keypad to the COM terminal on the gate opener control board.
Connect #2 wire from the RELAY OUTPUT terminals on the keypad to the COM terminal on the gate opener control board. #1 #2
Connect #1 wire from the RELAY OUTPUT terminals on the keypad to CYCLE terminal on the gate opener control board.

Add Temporary Entry Code: 1. Press and release PROGRAM button. 2. Enter the Master Code then press and release PROGRAM
button. 3. Enter “8” and any number between 1 thru 7 then press and
release the PROGRAM button. The second number (1 thru 7) indicates the number of days after which the code will be automatically removed from memory.* 4. Enter the new Entry Code then press and release PROGRAM
button. The keypad will beep 3 times to confirm that the new Entry Code is accepted.**
whenever any button is pressed. • If more than 10 seconds elapse between key presses, the
Entry Code that will remain valid for only three days (“1234” is the Master Code).
STATUS light will blink twice and the keypad will beep twice to confirm that a matched code is entered. • No more than 20 key presses are allowed to obtain a
*NOTE: If memory is full (there are already 25 programmed Entry Codes) the STATUS light will flash rapidly and the Keypad will beep for 2 seconds before returning to idle mode without saving.
4-digit Entry Code. For example, “1234” is one of the programmed Entry Codes. The user can enter “x1234” or “xxxxxxxxxxxxxxxx1234” (with “x” being any key) and the gate will be activated. If more than 20 key presses are entered without matching one of the Entry Codes, then the STATUS light will flash rapidly and the keypad will go into “lock-down” mode for 40 seconds. The user must not enter any code for at least 40 seconds before the unit returns to idle mode.
**NOTE: If the code is NOT 4-digits in length or an error has occurred, the STATUS light will flash rapidly and the keypad will beep for 2 seconds before returning to idle mode without saving.
Program New Master Code: 1. Press and release PROGRAM button. 2. Enter the old Master Code, then press and release
Delete An Entry Code: 1. Press and release PROGRAM button. 2. Enter the Master Code then press and release PROGRAM
PROGRAM button. 3. Enter “06” then press and release PROGRAM button. 4. Enter the new Master Code, then press and release
button. 3. Enter “03” then press and release PROGRAM button. 5. Enter the Entry Code to be deleted, then press and release
PROGRAM button. The keypad will beep 3 times to confirm that the Entry Code is deleted. NOTE: If no matching code is found or the code is NOT 4-digit in length, then an error has occurred. The STATUS light will flash rapidly and the keypad will beep for 2 seconds before returning to idle without saving.
press and release PROGRAM button. 6. Keypad beeps 3 times to confirm that the new Master Code
is accepted. NOTE: If the new Master Code is not a matched pair or an error occurs (e.g., if the entry code is NOT a 4-digit code), the STATUS light will flash rapidly and the keypad will beep for 2 seconds before returning to idle mode with old Master Code.
Example: Key press sequence to delete entry code “3456” from memory (“1234” is the Master Code).
Example: Key press sequence to change Master Code from “1234” to “3121.” 1 2 3 4 0 6 3 1 2 1 3 1 2 1
Add New Entry Code: 1. Press and release PROGRAM button. 2. Enter the Master Code, then press and release PROGRAM
Delete ALL Entry Codes: 1. Press and release PROGRAM button. 2. Enter the Master Code then press and release PROGRAM
button. 3. Enter “02” then press and release PROGRAM button.* 4. Enter the new Entry Code, then press and release
keypad will beep 3 times to confirm that all Entry Codes are deleted. Example: Key press sequence to delete all entry codes from
PROGRAM button. The keypad will beep 3 times to confirm that the new Entry Code is accepted. **
memory (“1234” is the Master Code).
Example: Key press sequence to add “3456” as a new entry code (“1234” is the Master Code).
1 2 3 4 0 2 3 4 5 6

POWER Light: GREEN: charging; RED: battery power mode (unplugged from transformer); Blinking RED: low battery.

KEYPAD BATTERY INDICATOR Light: LED turns ON when keypad battery is low.
PUSH TO ANSWER/TALK Button: Use to answer CALL from keypad. PRESS and HOLD to talk; RELEASE to listen.
GRANT ACCESS Button: Must be pressed before the person at the keypad can press any key to open the gate.
END CALL Button: Allows user to terminate the call.
9 Vdc Transformer Plug: Connect transformer here to charge the base unit battery.

VOLUME Control: Controls volume level of speaker.
BATTERY ACCESS Cover: Rechargable 3.6 Volt Ni-MH battery (included).
ON/OFF Switch: Turn OFF to conserve power when battery operated.
ID SET button: Used only to reassign new ID code (links base to keypad).


6. Connect the Transformer

The base unit can be disconnected from the transformer for use in another location. The battery will last approximately four (4) hours when unplugged from the transformer. IMPORTANT: You can turn the base unit OFF to conserve battery power, however it will not receive a signal when OFF.

Intercom ID Codes The keypad and base unit are programmed at the factory to communicate with each other, and do not need the ID Codes
programmed. This base unit is the MASTER or #1 unit.
If you have purchased additional base units (F3101MBC) to enhance your system, each additional unit’s ID Code must be programmed into the keypad so they can communicate.
1 2 3 4 5 6 7 8 9
RELAY OUTPUT
AC/DC POWERIN
RESET
CALLING GRANTED
1 2 ABC 3 DEF
4 GHI 5 JKL 6 MNO
7 PRS 8 TUV 9 WXY
CALL
Keypad - Inside
Keypad - Front
8. Test the System
VOLUME POWER
OFF ON
Have someone press the CALL button on the keypad at the gate. When the base unit inside the house rings, press the ANSWER button and talk to the person at the gate to check the connection and range. Then press the GRANT PERMISSION button and have the person at the gate press any key on the keypad to activate the gate.
Base Unit – Bottom
Troubleshooting Make sure all connections are secure and correct, batteries installed, and base unit is ON. If you have multiple base units, they should be at least 10 feet apart to prevent interference.

1 2 3 4 5 6 7 8 9
In rare cases, other devices operating in the same frequency band may cause interference with the intercom signal. If the system does not communicate at all, reassign the base unit/keypad ID code as follows (this will require two people):
the “ID SET” button on the bottom of the intercom base unit. 2. Make sure the “antenna-to-antenna” distance between the keypad and the

base unit is at least 30 feet. 3. Press the “ID SET” button on the keypad until you hear a beep, then release. This erases all stored ID Codes. 4. Press the “ID SET” button on the MASTER base unit for approximately 2 seconds then release. You will hear ONE
beep from the base unit and TWO from the keypad, which means the ID Codes are reassigned. 5. Test the system by pressing the CALL button on the keypad to see if the base unit receives the signal. Once the system
is working, you will need to reset additional base stations (see page 5).
If all connections are correct and the ID SET change didn’t solve the communication problem, please call our Technical Service Department at 1-800-543-1236, Monday–Friday, 8:00 am to 7:00 p.m. (ET).
Gates That Open, LLC (“GTO”). gate opener accessories are warranted by the manufacturer against defects in workmanship for a period of one (1) year from the date of purchase, provided recommended installation procedures have been followed.
The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or for the reinstallation of those parts after repair. This warranty shall be considered void if damage to the product(s) was due to improper installation or use, connection to an improper power source, tampering, or if damage was caused by lightning, electrical power surge, wind, fire, flood, insects, or other natural agent.
After the one (1) year warranty period, GTO or one of its authorized service centers will make any necessary repairs for a nominal fee. Call GTO at 850/575-4144 for more information. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. This warranty is in lieu of all other war- ranties, expressed or implied. NOTE: Verification of the warranty period requires copies of receipts or other proof of purchase. Please retain those records.
If you have any questions or concerns, please contact our Technical Service Department
Monday thru Friday 8:00 a.m. to 7:00 p.m. (ET) at 1-800-543-1236 or 850-575-4144