VERTIV Edge-Ready Micro Data Centre System (VRC-S)

8 pages·347 KB·Server·PDF·ENDEFRITNLJA
VERTIV Edge-Ready Micro Data Centre System (VRC-S)
Table of Contents 26 sections Vertiv ™ VRC-S · Edge-Ready Micro Data Centre System · Vertiv ™ VRC-S Edge-Ready Micro Data Centre System · What's In The Box? · … ShowHide
Page 1 of the VERTIV Edge-Ready Micro Data Centre System (VRC-S) user manual — Vertiv ™ VRC-S
Page 1 · click to enlarge
Page 1
VERTIV Edge-Ready Micro Data Centre System (VRC-S) — Vertiv ™ VRC-S diagram (page 1)
Fig. 1 · Vertiv ™ VRC-S

Vertiv ™ VRC-S

Edge-Ready Micro Data Centre System

Self-contained IT Rack Solution with integrated Power Distribution, Cooling, Monitoring and UPS up to 3.5 kW IT load

VERTIV Edge-Ready Micro Data Centre System (VRC-S) — Vertiv ™ VRC-S diagram (page 1)
Fig. 2 · Vertiv ™ VRC-S
Page 2 of the VERTIV Edge-Ready Micro Data Centre System (VRC-S) user manual — Ideally Suited For:
Page 2 · click to enlarge
Page 2

Vertiv ™ VRC-S Edge-Ready Micro Data Centre System

Vertiv ™ VRC-S

What's In The Box?

Deploy a Comprehensive Edge Micro Data Centre Solution in Days

Factory integrated micro data centre with:

Vertiv VRC-S is a micro data centre solution, fully assembled at the factory and designed specifically for IT edge applications. Available in various configurations, the Vertiv VRC-S is delivered in days and installed in hours. Choose from four different cabinet sizes with two separate cooling methods (split and self- contained) with back-up, and the option to integrate a UPS. Plus, an intelligent switched PDU, including monitoring of all components, and a comprehensive software package completes the offer.

y Vertiv™ VR Rack-based cabinet

y Vertiv™ VRC KIT split or self- contained IT cooling unit:

y Rack-mounted cooling unit offering 3.5kW of IT cooling capacity

y Integrated heat rejection system of your choice

y Vertiv™ Geist™ rPDU with

You have everything you need to rapidly upgrade any space with a micro data centre to host IT edge equipment. With space to support your IT equipment and up to 3.5kW of integrated IT cooling, around a single phase 16A connection, the Vertiv VRC-S lets you quickly, easily, and confidently put IT wherever you need it.

sensors, switched and monitored on outlet level

y Vertiv™ Intelligence Director

y Backup fan system connected to intelligent sensors and pre-programmed outlets

Piecing together the various components of an IT solution, for your edge applications, can be a major challenge for today’s busy IT managers. From specifying the right components, to waiting for a custom solution to be built, or integrating the appropriate cooling, UPS, PDU, and monitoring, the process consumes time and resources that you don’t always have to spare.

y Optional UPS Liebert® GXT5 6000VA

y Set of blanking panels10x 1RU

The new Vertiv VRC-S takes the legwork and wait time out of the equation. It offers a factory-integrated, micro data centre solution that ships in days and can be installed within hours. You get a plug-and-play IT solution that reliably and efficiently satisfies your edge IT requirements, and comes with the added peace of mind of a three-year warranty, covering every component of the system.

Ideally Suited For:

y Open office space

VERTIV Edge-Ready Micro Data Centre System (VRC-S) — Ideally Suited For: diagram (page 2)
Fig. 3 · Ideally Suited For:

y Light industrial areas

Show 5 more labels / short text on this page
y Condensate pump · monitoring software · y IT Closets · y Remote locations · y Unconditioned areas
Page 3 of the VERTIV Edge-Ready Micro Data Centre System (VRC-S) user manual — Cabinet size:
Page 3 · click to enlarge
Page 3

Vertiv ™ VRC-S Key Features and Benefits

Select Your Vertiv™ VRC-S

Features Benefits

3.5kW IT cooling:

A completely prefabricated micro data centre with your choice of 24 standard models.

Planning effort is minimised All components are guaranteed to work seamlessly to meet your requirements. The system is ready to ship in days.

y Self-contained: Heat rejection inside the building, e.g. in a large manufacturing or warehouse hall, or in a suspended ceiling.

Vertiv™ VR rack-based durable IT cabinet available in a range of four sizes with 1000 kg of Dynamic load

Adaptable to IT space requirements Choose the cabinet size you need to optimally support your IT equipment; the enclosed system enhances security and cooling efficiency.

y Split cooling: Heat rejection through a refrigerant pipe through the building shell to the included pre-filled outdoor condenser.

Vertiv adaptive Vertiv™ VRC rack cooling system with 3.5kW cooling capacity and two heat rejections

Low operating costs due to efficient cooling The cooling system adapts its capacity to the IT heat, thus reducing energy costs. The heat remains inside or is removed through the building shell.

Backup fan system controlled by cooling system independent sensorsIncreased availability through backup cooling Generate additional protection with emergency airflow provided during cooling outages, extending your time for a controlled shutdown or further ensuring IT equipment availability. Intelligent Vertiv™ Geist™ Rack PDU with sensors, switched on an outlet levelHigher reliability by monitoring and remote control Monitor and control your IT equipment on power outlet level for improved visibility, serviceability, reliability, and availability. Vertiv™ Intelligence Director Monitoring softwareReduced labour costs through monitoring optimisation Remote control and monitoring of all installed components, consolidated in one software and one IP address, reduces the workload of IT staff. Single-phase online double conversion 6 kVA Liebert® GXT5 UPSPower Continuity - Highest availability for your IT assets Application continuity is maintained during a utility power outage, as the UPS powers the cooling system and the IT assets, without interruption. 3 years warranty for the complete system with product registrationReduction of maintenance costs Protect your entire system for complete peace of mind.

y Minimum ambient air down to -15 °C (standard)

y Minimum ambient air down to -34 °C (low ambient)

UPS:

y With or without a Single phase online double conversion 6 kVA Liebert® GXT5 UPS

Recommended Vertiv ™ VR Rack Accessories:

y Additional batteries to increase

y Additional blanking panels to

improve isolation of the cool air in the front of the rack are highly recommended

y Cable management accessories to keep cables organised and prevent cables from restricting airflow or causing safety hazards

Select Your Vertiv™ VRC-S

y Vertiv™ Geist™ SwitchAir™ airflow

management solution for network equipment that is not front-breathing

The Vertiv VRC-S includes all the components of a state-of-the-art micro data centre,

fully factory assembled to work seamlessly to meet your requirements and simplify IT management for your edge applications. Make your selection to customise your micro data centre.

y Establish a second power path for downtime minimisation with an additional PDU and UPS

Cabinet size:

y Advanced access control with a

y Height 2000 mm, Width 800 mm, Depth 1200mm, Total Rack Space 42 U

y Height 2000 mm, Width 600 mm, Depth 1200mm, Total Rack Space 42 U

y Height 2265 mm, Width 600 mm, Depth 1200mm, Total Rack Space 48 U

y Height 2265 mm, Width 800 mm, Depth 1200mm, Total Rack Space 48 U

UPS backup time · card reader lock

Page 4 of the VERTIV Edge-Ready Micro Data Centre System (VRC-S) user manual — 3. Low operational cost
Page 4 · click to enlarge
Page 4

Vertiv ™ VRC-S Edge-Ready Micro Data Centre System

Your Benefits Form Vertiv ™ VRC-S

1. "Plug and Play"

4. Remote monitoring and control

5. 3-year warranty across the entire Vertiv VRC-S system

The Vertiv™ VRC-S is a "plug and play" factory assembled micro data centre, shipped within days, and deployed within hours. The project planning costs are minimised because all components are integrated and matched to each other. Power and network must be connected and, if necessary, cooling integrated into the building or the pre-filled outdoor condenser needs to be installed. Once installed, operations can begin, thus greatly reducing installation costs.

Reliable and well-designed remote monitoring and control are crucial for the operation of edge applications in remote locations without IT staff on site. The Vertiv™ Intelligence Director provides access to all Vertiv VRC-S networked components, Vertiv™ VRC cooling, UPS, and PDU under one IP address and supports all common network protocols. The PDU can be switched and monitored per output, making it easy to control the application remotely. It is possible to integrate the Vertiv VRC-S application with Vertiv™ Environet™ Alert software into a data centre infrastructure management system (DCIM).

Get an extension of factory warranty coverage beyond the original factory warranty term registering your product at Vertiv Website https://www.vertiv.com/ en-emea/support/register-your-product/ registration/. The product registration extends factory warranty to a total of 3 years on the entire VRC-S system. With this 3-year warranty on the entire system, Vertiv gives its promise of quality. Protect your entire system for complete peace of mind.

2. Highest availability

For unsurpassed reliability and maximum lifetime of your IT equipment, only the best industry-standard components have been selected for the Vertiv VRC-S. All of these components are harmonised with each other and provide the IT asset with the best conditions for uninterrupted operation. The UPS powers the cooling system and the IT assets without interruption during a utility power outage. In case of cooling system loss, integrated back-up ventilation enables operation without interruption.

VERTIV Edge-Ready Micro Data Centre System (VRC-S) — 2. Highest availability diagram (page 4)
Fig. 4 · 2. Highest availability

Top cable entry brush kit

Cabinet based on Vertiv™ VR Rack platform

VERTIV Edge-Ready Micro Data Centre System (VRC-S) — 2. Highest availability diagram (page 4)
Fig. 5 · 2. Highest availability

3. Low operational cost

Vertiv VRC-S is designed to have the lowest possible operating costs. By using speed-controlled fans and a compressor, the Vertiv VRC cooling unit adapts the cooling to the actual IT heat dissipation and thus consumes only as much energy as necessary. The Energy Star 2.0 certified UPS uses the highest possible power factor, depending on the mode, reducing electricity costs.

Intelligent Vertiv™ Geist™ Rack PDU

Back Up Fan · Liebert® GXT5 UPS

Page 5 of the VERTIV Edge-Ready Micro Data Centre System (VRC-S) user manual — Site Requirements:
Page 5 · click to enlarge
Page 5
Vertiv™ VRC-S ServicesComplete Range of Service Programs Including On-Site Services Support/Maintenance Programs
White Glove On-site ServicesGet your system off to the best possible start

On-site Service Programs include:

y Coordinating the install and any prerequisites directly with you to streamline the installation process

y Reviewing all work to be performed and all safety requirements with your onsite team

Factory-trained Vertiv Services technicians can provide professional installation and startup of your Vertiv™ VRC-S. This simplifies the process and eliminates any concerns you may have about correctly, safely, and efficiently installing your equipment, which can be especially valuable for multisystem installations and multi-site rollouts. Vertiv factory-trained technicians perform the complete startup checklist and ensure your rack cooling unit is operating flawlessly from the get-go. As experts in the Vertiv VRC-S and all of its components, no one knows the equipment and installation process more intimately than Vertiv Services. You can trust your knowledgeable installation team to get the job done right, on time, and to answer any questions you and your on-site personnel may have. This ensures you’re prepared to fully enjoy the many benefits of your new micro data centre system out of the box. At Vertiv Services, we stand by our equipment and strive to leave you completely satisfied with your purchase and installation process.

y Uncrating and unpackaging all components and safely moving them to the designated location

y Levelling and labelling the network cabinet

y Mounting and securing the rack cooling unit

y Installing the heat rejection duct including connections to the Vertiv™ VRC and ceiling grid

y Installing the condensate pump

y Running the drain line under construction to an existing drain

y Plugging in the PDUs

y Extending, connecting, and grooming power and network cables

y Preforming status check of all alarm circuits

y Completing system startup

y Providing debris clean up and removal to customer-provided receptacle

Support/Maintenance Programs: Optimise Performance, Extend the Life of Your Micro Data Centre and Provide 24/7 Remote Support.

Maintenance and Support programs include a 24x7 professional helpline and grant response within an agreed time frame, providing either the component replacement or the on-site intervention of a Vertiv technician.

Technical Data

Site Requirements:

y Drain within 6m of location to accommodate the included condensate pump

y Floor must support a minimum of 1500kg

y 900mm of clearance in front and rear of rack

y Utility power230 VAC, 1 phase, 50 Hz, 32 A
y Wall-mounted receptacleIEC60309 2P+E, 250 V splashproof IP44

y For Vertiv™ VRC split: Installation of the refrigerant pipes between the 19" rack mounted indoor unit and the outdoor unit

Page 6 of the VERTIV Edge-Ready Micro Data Centre System (VRC-S) user manual — Vertiv ™ VRC-S Edge-Ready Micro Data Centre System
Page 6 · click to enlarge
Page 6

Vertiv ™ VRC-S Edge-Ready Micro Data Centre System

Vertiv™ VRC-S part numberVRCS3350-230VU VRCS3350-230V VRCS3350-230VSU VRCS3350-230VS VRCS3350-230VSLU VRCS3350-230VSL

Cabinet size Height 2000 mm, Width 800 mm, Depth 1200mm, Total Rack Space 42 U

Usable rack space [U] 27 32 31 36 31 36

Usable payload [kg] 806 877 858 929 858 929

Configured system weight [kg] 392 321 341 270 341 270

Shipping weight [kg] 492 421 492 406 507 421

Intput Voltage and Connection230 V / 1Ph / 50 Hz; IEC60309 2P+E, 32 A, 250 V Splashproof IP44; 2,5 m cable (outlet at the bottom) Vertiv™ VRC Split Vertiv™ VRC Split Cooling Unit Vertiv™ VRC self-contained (-15°C minimum ambient temp.) (-34°C minimum ambient temp.) Model NumberVRC102KITVRC202KIT-NVRC202KIT-L Cooling Capacity* 3,5kW3,8kW3,4kW Average sound pressure**57,8 dB (A) @ 1 m52,0 dB (A) @ 1 m UPS Liebert® GXT5 6kVANo GU30017LLiebert® GXT5 6kVANo GU30017LLiebert® GXT5 6kVANo GU30017L UPS Model NumberGXT56000IRT5UXLEGXT56000IRT5UXLEGXT56000IRT5UXLE PDU Model Number GU30017L*****GU30017L*****GU30017L***** Communication protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+

Certificated CE, RoHS, REACH

Vertiv™ VRC-S part numberVRCS3300-230VU VRCS3300-230V VRCS3300-230VSU VRCS3300-230VS VRCS3300-230VSLU VRCS3300-230VSL

Cabinet size Height 2000 mm, Width 600 mm, Depth 1200mm, Total Rack Space 42 U

Usable rack space [U] 27 32 31 36 31 36

Usable payload [kg] 806 877 858 929 858 929

Configured system weight [kg] 347 276 296 225 296 225

Shipping weight [kg] 434 363 449 378 464 393

Intput Voltage and Connection230 V / 1Ph / 50 Hz; IEC60309 2P+E, 32 A, 250 V Splashproof IP44; 2,5 m cable (outlet at the bottom) Vertiv™ VRC Split Vertiv™ VRC Split Cooling Unit Vertiv™ VRC self-contained (-15°C minimum ambient temp.) (-34°C minimum ambient temp.) Model NumberVRC102KITVRC202KIT-NVRC202KIT-L Cooling Capacity* 3,5kW3,8kW3,4kW Average sound pressure**57,8 dB (A) @ 1 m52,0 dB (A) @ 1 m UPS Liebert® GXT5 6kVANo GU30017LLiebert® GXT5 6kVANo GU30017LLiebert® GXT5 6kVANo GU30017L UPS Model NumberGXT56000IRT5UXLEGXT56000IRT5UXLEGXT56000IRT5UXLE PDU Model Number GU30017L*****GU30017L*****GU30017L***** Communication protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+

Certificated CE, RoHS, REACH

Vertiv™ VRC-S part numberVRCS3307-230VU VRCS3307-230V VRCS3307-230VSU VRCS3307-230VS VRCS3307-230VSLU VRCS3307-230VSL

Cabinet size Height 2265 mm, Width 600 mm, Depth 1200mm, Total Rack Space 48 U

Usable rack space [U] 33 38 37 42 37 42

Usable payload [kg] 806 877 858 929 858 929

Configured system weight [kg] 383 312 332 261 332 261

Shipping weight [kg] 470 399 455 384 470 399

Intput Voltage and Connection230 V / 1Ph / 50 Hz; IEC60309 2P+E, 32 A, 250 V Splashproof IP44; 2,5 m cable (outlet at the bottom) Cooling Unit Vertiv™ VRC self-containedVertiv™ VRC Split (-15°C minimum ambient temp.)Vertiv™ VRC Split (-34°C minimum ambient temp.) Model NumberVRC102KITVRC202KIT-NVRC202KIT-L Cooling Capacity* 3,5kW3,8kW3,4kW Average sound pressure**57,8 dB (A) @ 1 m52,0 dB (A) @ 1 m UPS Liebert® GXT5 6kVANo GU30017LLiebert® GXT5 6kVANo GU30017LLiebert® GXT5 6kVANo GU30017L UPS Model NumberGXT56000IRT5UXLEGXT56000IRT5UXLEGXT56000IRT5UXLE PDU Model Number GU30017L*****GU30017L*****GU30017L***** Communication protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+

Certificated CE, RoHS, REACH

Page 7 of the VERTIV Edge-Ready Micro Data Centre System (VRC-S) user manual — UPS Integrated Liebert ® GXT5-6000IRT5UXLE
Page 7 · click to enlarge
Page 7
Vertiv™ VRC-S part numberVRCS3357-230VU VRCS3357-230V VRCS3357-230VSU VRCS3357-230VS VRCS3357-230VSLU VRCS3357-230VSL

Cabinet size Height 2265 mm, Width 800 mm, Depth 1200mm, Total Rack Space 48 U

Usable rack space [U] 33 38 37 42 37 42

Usable payload [kg] 806 877 858 929 858 929

Configured system weight [kg] 410 399 359 288 359 288

Shipping weight [kg] 510 439 495 424 510 439

Intput Voltage and Connection230 V / 1Ph / 50 Hz; IEC60309 2P+E, 32 A, 250 V Splashproof IP44; 2,5 m cable (outlet at the bottom) Vertiv™ VRC Split Vertiv™ VRC Split Cooling Unit Vertiv™ VRC self-contained (-15°C minimum ambient temp.) (-34°C minimum ambient temp.) Model NumberVRC102KITVRC202KIT-NVRC202KIT-L Cooling Capacity* 3,5kW3,8kW3,4kW Average sound pressure**57,8 dB (A) @ 1 m52,0 dB (A) @ 1 m UPS Liebert® GXT5 6kVALiebert® GXT5 6kVA UPS Model NumberGXT56000IRT5UXLEGXT56000IRT5UXLE

PDU Model Number GU30017L***** GU30017L GU30017L***** GU30017L GU30017L***** GU30017L

Communication protocols DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+

Certificated CE, RoHS, REACH

Cooling unit Vertiv™ VRC Rack Cooling System

Cooling method self-containedsplit system Model numberVRC102KITVRC202KIT-NVRC202KIT-L Minimum Outdoor Operating Temperature N/A-15°C -34 °C Piping length between indoor and outdoor unitN/Amax. 30 m***max. 30 m*** Condenser air duct length 3,8 mN/A N/A Net sensible cooling capacity*3,5 kW3,8 kW3,4 kW Capacity modulation 25 - 100 %25 - 100 % 25 - 100 % Full load amperage (total / indoor / outdoor)11,5 A8,0 A / 1,5 A / 6,5 A8,0 A / 1,5 A / 6,5 A Max. power input 1,86 kW1,33 kW 1,33 kW EER1,882,632,56 Refrigerant R410 (pre-charged) 720 g1300 g 4000 g Cooling air flow750 m³/h750 m³/h750 m³/h Occupied U space 10 U6 U 6 U LCD Screen includedYESYESYES Outdoor condenser Unit H, W, D [mm] N/A527, 282, 786 527, 282, 1158

UPS Integrated Liebert ® GXT5-6000IRT5UXLE

PDU Integrated rPDU GU30017L

TypeOnline double conversion Rating 6000 VA (IT load according max. cooling capacity) Occupied U space5 U Operating frequency 50 or 60 Hz (factory-default is 50 Hz) User-configurable AC voltage200/208/220/230/240 VAC (Factory-default is 230 VAC) AC-AC Efficiency 94% WaveformSine wave Battery 16 x 12 V x 9,0 Ah Output receptacles(6) IEC 60320 C13, (2) IEC 60320 C19 ****
TypeSwitched and monitored on outlet level Input 200 - 240 VAC / 32 A / 1Ph / 50 Hz PositionVertical Receptacles (20) Locking IEC 60320 C13, (4) Locking IEC 60320 C19 **** CommunicationEmbedded Vertive Intelligence Director Input Monitoring Phase (A) Monitoring (kWh, W, VA, PF, V, A) Outlet MonitoringEach outlet (kWh, W, VA, PF, V, A) Power Management Individual outlet switching, timing, delay, sequence Over Current Protection(2) 16A Single Pole Magnetic Breakers (5kAIC Rated)

*Air Temperature to IT equipment 21°C, Outdoor air temperature 35°C ** constant 100% heat load *** extension on request **** (2) IEC C13 outlets used by backup fan and condensate pump ***** hard hardwired connection between UPS and PDU

Page 8 of the VERTIV Edge-Ready Micro Data Centre System (VRC-S) user manual — SL-07004-EMEA (R02/21)
Page 8 · click to enlarge
Page 8
VERTIV Edge-Ready Micro Data Centre System (VRC-S) — SL-07004-EMEA (R02/21) diagram (page 8)
Fig. 6
VERTIV Edge-Ready Micro Data Centre System (VRC-S) — SL-07004-EMEA (R02/21) diagram (page 8)
Fig. 7
VERTIV Edge-Ready Micro Data Centre System (VRC-S) — SL-07004-EMEA (R02/21) diagram (page 8)
Fig. 8
VERTIV Edge-Ready Micro Data Centre System (VRC-S) — SL-07004-EMEA (R02/21) diagram (page 8)
Fig. 9
VERTIV Edge-Ready Micro Data Centre System (VRC-S) — SL-07004-EMEA (R02/21) diagram (page 8)
Fig. 10
VERTIV Edge-Ready Micro Data Centre System (VRC-S) — SL-07004-EMEA (R02/21) diagram (page 8)
Fig. 11

Vertiv.com | Fraser Road, Priory Business Park, Bedford, MK44 3BF, United Kingdom

© 2021 Vertiv Group Corp. All rights reserved. Vertiv™ and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness here, Vertiv Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications, rebates and other promotional offers are subject to change at Vertiv’s sole discretion upon notice.

SL-07004-EMEA (R02/21)

Ask about the VERTIV Edge-Ready Micro Data Centre System (VRC-S)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the VERTIV Edge-Ready Micro Data Centre System (VRC-S)

Be the first to ask — other owners or our team will answer.