only.
This product can be fitted to mains water supply.
A 21mm G½ (½”bsp) Adaptor
This product can be fitted to outdoor water butts or tanks that
B 26.5mm G¾ (¾”bsp) Adaptor
C 33.3mm G1 (1”bsp) Adaptor
You must use Alkaline batteries – alternatives will result in incorrect operation.
E LED indicator lights
F Water Now button - On/Off/Override
1 Remove the front panel as shown (Fig. 1), gripping the recessed part and pulling towards you.
G Hose pipe connector
2 Insert 2 x 1.5v AA (LR6) batteries (Fig. 1) and replace the controller front panel.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO USE THIS PRODUCT.
3 Replace batteries each season. (max 8 months use, used twice a day)
4 When batteries are installed the motor will operate the internal valve to check that it is ready for use and the batteries installed have enough charge to safely operate the valve
FAILURE TO OBSERVE THE FOLLOWING NOTICES MAY RESULT IN INJURY OR PRODUCT DAMAGE
5 If the LED indicator flashes red, the batteries need to be replaced. Connecting the Sensor Controller to the tap
HOZELOCK WEBSITE.
This product meets the requirements of IP44 and therefore can
1 Choose the correct tap adapter (Fig. 3)
be used in exposed weather conditions.
2 Using the correct adapter(s), attach the controller to the tap and tighten firmly to avoid leaks. Do not use a spanner or other tool to tighten as this might damage the threads. (Fig. 4)
This product is not suitable for supplying drinking water.
Threaded water connections are suitable for hand tightening
3 Turn on the Tap.
D Duration dial · H Light Sensor

It is important that your water controller is in an outdoor location. Do not point the control panel directly towards outdoor security lights or other bright lights that come on during the night as these might interfere with the recorded light levels and cause the controller to come on at the wrong time.
Sunrise and Sunset is the best time to water your garden to avoid evaporation and leaf scorch. The Daylight sensor automatically adjusts the watering schedule to coincide with the changing time for sunrise and sunset.
Ideally, you should not set up your controller in a heavily shaded passageway or behind buildings where light levels remain low all day long. Do not position the controller inside buildings such as garages or sheds where it will not receive natural daylight to function correctly.
Cloudy or overcast mornings and evenings might cause a slight delay to the watering times, but these are not significant to have any adverse effects on your garden.
1 Rotate the control dial to select from the 3 marked sections – Sunrise (once a day), Sunset (once a day) or Sunrise and Sunset (twice a day). (See Fig. 5)
The controller is designed to be positioned directly underneath an outdoor tap. Do not position the controller on its side or lying on the ground whereby rainwater cannot flow away from the product. 1 hour delay (when using 2 Sensor Controllers together)
2 Choose from the required watering durations – 2, 5, 10, 20, 30 or 60 minutes of watering. How to turn off the Sensor Controller
If you install two Sensor Controllers you might want to stagger the start times to prevent pressure loss when two appliances are used simultaneously – for example sprinklers.
If you do not want the controller to automatically come on turn the rotary dial to the “OFF” position. You can still use the button to manually water your garden. Initial synchronisation period
Remove the delay plug from the storage location on the back of the control panel (Fig. 2) and fit the plug on the location below the batteries.
When you install new batteries there is a 6 hour lockout period to prevent the controller from watering while you are setting up your system. After a 24 hour cycle of Sunrise and Sunset the controller will be synchronised with the changing light levels. You can manually water your garden using the button during the 6 hour lockout period. Positioning your Sensor Controller outdoors
With the plug inserted the one hour delay affects all automatic watering. The delay period of one hour cannot be changed. Manual operation (water now)
You can turn on the water controller at any time by pressing the button once. Press again to turn off at any time.

The button can also be used as a manual override to cancel any current automatic watering operation that has started. The schedule will then resume. Battery level check
Press and hold down the Water Now button to check the status of the batteries at any time.
GREEN = BATTERY IS GOOD RED = BATTERY LEVEL IS LOW, REPLACE THE BATTERIES SOON. Failure prevention mode
A built in safety feature detects when the battery levels have dropped to a level that could fail whilst the valve is open and result in wasting water. The safety mode prevents the controller from turning on until the batteries have been replaced. The LED indicator light will flash red when the failure prevention mode has been activated. The Water Now function will also not operate until the batteries have been replaced.
This product is not designed to be used in sub-zero (frost)
temperatures. During winter months drain any remaining water out of your timer and bring it indoors until the next watering season.

Hozelock Ltd declare that the following Electrically Operated Water Valves: • Sensor Controller (2212)
If you have any further problems with your water timer please contact Hozelock customer services.
Hozelock Limited Midpoint Park, Brimingham. B76 1AB.
Signed by:
Nick Iaciofano Technical Director, Hozelock Ltd. Midpoint Park, Sutton Coldfield, B76 1AB. England.

www.hozelock.com 201014-a0001 40152-000
WEEE Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well- being. In the EU, when replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Valve opens but no water comes out | Garden tap is off | Turn on tap | p.6 |
| Valve opens but no water comes out | Hose pipe twisted or blocked | Untwist/unblock hose hose | p.6 |
| Button pressed but valve doesn’t open | Wrong or flat batteries | Check battery type and/or replace with fresh batteries | p.6 |
| Button pressed Light came on but valve did not open | 1 minute lock out has operated | Wait three minutes and try again | p.6 |
| Controller set up correctly but did not come on at sunset | Controller waiting to synchronise | Wait 24hrs and observe again | p.6 |
| Controller activated when outside lights come on | Outside lights too bright | Move or rotate controller away from light sources | p.6 |