HOMEOWNER Guide
Step 1: Keys and Display - MiTime
RF Packs: T710R, T720R, T720M, T740R, T 740M
MiTime
TM Programmer Series RF Packs
Note:
See help in product menu for quick button description.
Home screen, depending on model - see Step 2
: Indicates an RF transmission issue or Service warning.
: Indicates that holiday is enabled
... an explanation for householders

+hr key: Press from the home or zone details screens to add up to 3 hours to the current period
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at different times.
Advance key: Press from the home or zone details screens to advance to the next on or off period
Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time.
Help text to prompt for next action. It relates to the highlighted line
Technical Helpline: 0333 7000 622 Website: www.draytoncontrols.co.uk E-mail: customer.care@draytoncontrols.co.uk l @DraytonControls x /DraytonControls
You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions.
401 Southway Drive Plymouth PL6 6QT United Kingdom
The heating will not work if the room thermostat has switched the heating off. Also, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature.
This icon used throughout these instructions refers to this button
EU Design Regs:- 002180638-1/2/3 User Guide 06490193001 Iss G
Step 3: Zone Details
What is a room thermostat?
What is a cylinder thermostat?
Step 2: Home Screens
... an explanation for householders
... an explanation for householders
Zone = Heating Current mode: Auto Options: see table below.
A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
A cylinder thermostat switches on and off the heat supply from the boiler to the hot-water cylinder. It works by sensing the temperature of the water inside the cylinder, switching on the water heating when the temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
Press Select ( ) to view or edit zone Press Select ( ) to change mode Press Select ( ) to view or edit zone

Zone = Heating Current status: the programme is On until 12:00 am Link to zone details, see Step 3.
Zone = Heating Current status: the programme is On until 12:00 am Link to zone details, see Step 3.
Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators.

Turning a cylinder thermostat to a higher setting will not make the water heat up any faster. How quickly the water heats up depends on the design of the heating system, for example, the size of boiler and the heat exchanger inside the cylinder.
Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.


Link to Programme timetable See further detail in Step 4.
The water heating will not work if a time switch or programmer has switched it off. And the cylinder thermostat will not always switch the boiler off, because the boiler sometimes needs to heat the radiators.
The heating system will not work if a time switch or programmer has switched it off.
Temp: describes the current status of the zone temperature, e.g. Temperature in zone is 21.0C and the setpoint is 21.5C. Link to modify the zone temperature.
The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 18ºC – and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money.
See further details in Step 6.
Cylinder thermostats are usually fitted between one quarter and one third of the way up the cylinder. The cylinder thermostat will have a temperature scale marked on it, and it should be set at between 60C and 65C, then left to do its job. This temperature is high enough to kill off harmful bacteria in the water, but raising the temperature of the stored hot water any higher will result in wasted energy and increase the risk of scalding.
Zone = Zone 3 Current status: the programme is Always Off Link to zone details, see Step 3.
Temp: describes the current status of the zone temperature, e.g. Temperature in zone is 21.0C and the setpoint is 21.5C Link to modify the zone temperature.
Zone = Hot Water Current status: the programme is Off until 12:00 am Link to zone details, see Step 3.
Now: describes the current status, e.g. programme is On until 12:00 am. Link to Programme timetable - see further details in Step 4.
Zone = Hot Water Current status: the programme is Off until 12:00 am. Link to zone details, see Step 3.
Press Select ( ) to change mode
If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs.
If you have a boiler control thermostat, it should always be set to a higher temperature than that of the cylinder thermostat. In most boilers, a single boiler thermostat controls the temperature of water sent to both the cylinder and radiators, although in some there are two separate boiler thermostats.
Now: describes the current status, e.g. programme is On until 12:00 am. Link to Programme timetable - see further details in Step 4.
See further details in Step 6.
Link to Settings See further details in Step 6.
Current mode: Auto Options: see table in Step 3.
Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly.





RF Pack: MiStat N110R, MiStat C110C How do I know when to change the batteries?
Remove the battery covers as shown. Replace the batteries with 2 x 1.5V IEC LR6 (AA) Alkaline batteries ensuring correct orientation. Replace the battery covers pressing fully home.
RF transmission indication. The RF symbol will be visible as follows,
Call for heat indication. This flame will be visible when the room temperature is below the set temperature.
When the batteries start to run low a battery icon will flash in the display to indicate “low battery”, during this time the MiStat will function normally. When the battery icon alone is alone is shown in the display, the batteries are completely exhausted and the MiStat will cease to function (see below). Re-activate by replacing the batteries.
Short flashes indicates an RF transmission.
Current Setting, see table below
Long flashes indicates an RF transmission issue.
key: Press to toggle between Comfort setting, Eco setting and Home (Room thermostat only). See table below.
Press +hr to Boost
+hr key: Press to add up to 3 hours to the current period or to get instant 1 to 3 hours if currently off (see step 8).
Battery Handling
Press +/- to adjust +hr period between 0 and 3 hours Press ( ) to confirm
Batteries, rechargeable or not, should not be disposed of into ordinary household waste. Instead, they must be recycled properly to protect the environment and cut down the waste of precious resources.
Now the Boost is running. The time will be counted down each hour.
Comfort setting Selects the comfort setting. The pre-set value is used each time when activated, adjustable within the menu
Once the time has elapsed, control returns to the prior temperature screen.
Your local waste management authority can supply details concerning the proper disposal of batteries.
Eco setting Selects the Eco setting. The pre-set value is used each time when activated, adjustable within the menu.
The Boost can be cancelled by pressing the ( ) key or by setting the +hr period to 0.
In compliance with the EU Directive 2006/66/EC, the button cell battery located on the printed circuit board inside the product, can be removed at the end of the product life, by professional personnel only.
None Home screen Indicates that the pre-set temperatures were changed via +/- key
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.