EN
Drayton logo
Official user manual

Drayton MiTime Programmer Series

2 pages·985 KB·Programmer·PDF·ENDEFRITNLJA
Drayton MiTime Programmer Series
Table of Contents 16 sections Drayton · HOMEOWNER Guide · Step 1: Keys and Display - MiTime · RF Packs: T710R, T720R, T720M, T740R, T 740M · … ShowHide
Page 1 of the Drayton MiTime Programmer Series user manual — (not Single Channel)
Page 1 · click to enlarge
Page 1

Drayton

HOMEOWNER Guide

Step 1: Keys and Display - MiTime

RF Packs: T710R, T720R, T720M, T740R, T 740M

MiTime

TM Programmer Series RF Packs

Note:

See help in product menu for quick button description.

Home screen, depending on model - see Step 2

: Indicates an RF transmission issue or Service warning.

: Indicates that holiday is enabled

Single ChannelMiTime T710R Dual Channel: MiTime T720R, T720M Multi Channel: MiTime T740R, T740M

What is a programmer?

... an explanation for householders

Drayton MiTime Programmer Series — What is a programmer? diagram (page 1)
Fig. 1 · What is a programmer?

+hr key: Press from the home or zone details screens to add up to 3 hours to the current period

Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at different times.

Home keyPress to go back to the home screen at any time

Advance key: Press from the home or zone details screens to advance to the next on or off period

Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently off.

Back keyPress to return to the previous screen

The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time.

Help text to prompt for next action. It relates to the highlighted line

Technical Helpline: 0333 7000 622 Website: www.draytoncontrols.co.uk E-mail: customer.care@draytoncontrols.co.uk l @DraytonControls x /DraytonControls

You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions.

Drayton

401 Southway Drive Plymouth PL6 6QT United Kingdom

Select keyPress to select highlighted options, and to open and save editor screens
LEDIlluminates when any zone is scheduled to be ON

The heating will not work if the room thermostat has switched the heating off. Also, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature.

This icon used throughout these instructions refers to this button

EU Design Regs:- 002180638-1/2/3 User Guide 06490193001 Iss G

Arrow keysPress to move the highlight on screen, and to change field values

HOMEOWNER Guide

Step 3: Zone Details

What is a room thermostat?

What is a cylinder thermostat?

Step 2: Home Screens

(not Single Channel)

... an explanation for householders

... an explanation for householders

Single ChannelMiTime T710R Dual Channel: MiTime T720R, T720M Multi Channel: MiTime T740R, T740M

Zone = Heating Current mode: Auto Options: see table below.

A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.

A cylinder thermostat switches on and off the heat supply from the boiler to the hot-water cylinder. It works by sensing the temperature of the water inside the cylinder, switching on the water heating when the temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.

Press Select ( ) to view or edit zone Press Select ( ) to change mode Press Select ( ) to view or edit zone

Drayton MiTime Programmer Series — (not Single Channel) diagram (page 1)
Fig. 2 · (not Single Channel)

Zone = Heating Current status: the programme is On until 12:00 am Link to zone details, see Step 3.

Zone = Heating Current status: the programme is On until 12:00 am Link to zone details, see Step 3.

Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators.

Drayton MiTime Programmer Series — (not Single Channel) diagram (page 1)
Fig. 3 · (not Single Channel)

Turning a cylinder thermostat to a higher setting will not make the water heat up any faster. How quickly the water heats up depends on the design of the heating system, for example, the size of boiler and the heat exchanger inside the cylinder.

Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.

Drayton MiTime Programmer Series — (not Single Channel) diagram (page 1)
Fig. 4 · (not Single Channel)
Drayton MiTime Programmer Series — (not Single Channel) diagram (page 1)
Fig. 5 · (not Single Channel)

Link to Programme timetable See further detail in Step 4.

The water heating will not work if a time switch or programmer has switched it off. And the cylinder thermostat will not always switch the boiler off, because the boiler sometimes needs to heat the radiators.

The heating system will not work if a time switch or programmer has switched it off.

Temp: describes the current status of the zone temperature, e.g. Temperature in zone is 21.0C and the setpoint is 21.5C. Link to modify the zone temperature.

The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 18ºC – and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money.

See further details in Step 6.

Cylinder thermostats are usually fitted between one quarter and one third of the way up the cylinder. The cylinder thermostat will have a temperature scale marked on it, and it should be set at between 60C and 65C, then left to do its job. This temperature is high enough to kill off harmful bacteria in the water, but raising the temperature of the stored hot water any higher will result in wasted energy and increase the risk of scalding.

Zone = Zone 3 Current status: the programme is Always Off Link to zone details, see Step 3.

Temp: describes the current status of the zone temperature, e.g. Temperature in zone is 21.0C and the setpoint is 21.5C Link to modify the zone temperature.

Zone = Hot Water Current status: the programme is Off until 12:00 am Link to zone details, see Step 3.

Now: describes the current status, e.g. programme is On until 12:00 am. Link to Programme timetable - see further details in Step 4.

Zone = Hot Water Current status: the programme is Off until 12:00 am. Link to zone details, see Step 3.

Press Select ( ) to change mode

If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs.

If you have a boiler control thermostat, it should always be set to a higher temperature than that of the cylinder thermostat. In most boilers, a single boiler thermostat controls the temperature of water sent to both the cylinder and radiators, although in some there are two separate boiler thermostats.

Now: describes the current status, e.g. programme is On until 12:00 am. Link to Programme timetable - see further details in Step 4.

Mode:Description: AutoThe programmer will control the ON & OFF times in line with the programmed timetable Always OffThe selected zone will be OFF Always OnThe selected zone will be ON All Day (first on / last off)The programme will control the ON & OFF times in line with the programmed timetable, but using only the first ON event and the last OFF event - it will remain ON in between these two periods.

See further details in Step 6.

Link to Settings See further details in Step 6.

Current mode: Auto Options: see table in Step 3.

Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly.

Show 13 more labels / short text on this page
Date · MiStat · Drayton · Drayton · MiTime · Time · MiStat · Drayton · MiTime · Drayton · MiTime · Link to Settings · Link to Settings
Page 2 of the Drayton MiTime Programmer Series user manual — Drayton
Page 2 · click to enlarge
Page 2
Step 4: Prog. TimetableStep 5: Period SettingsStep 6: Additional User Settings Zone = Heating Link to Copy days Timetable day range: Monday to Friday (Week and weekend) Options: Individual days (7day), Week and weekend (5/2day), All week (24hr). The available blocks depend on the selection in menu “change timetable type” Help text: Use left/right buttons to select the days you want to change Arrow denotes that further options are available if you scroll down. Period 1 settings: describes the current timetable settings, e.g. Heating has been programmed to turn On at 6:30am and go off at 8:30am Period 2 settings: describes the current timetable settings, e.g. Heating has been programmed to turn On at 4:30pm and go off at 10:30pm Press select ( ) when highlighted to adjust settings (see Step 5) Up to 4 periods can be programmedDay range & period Highlight shows adjustable field: Use up/down buttons to adjust values Period settings: On at 6:30am and Off at 8:30am Help text: Use left/right buttons to change fieldsTroubleshooting: Press Select to enter a specific Setting. Options shown below: 1 Setting temperature values is restricted a A ser ee IM nsin taim llau tm io/ nM Ga ux ii dm eu Sm te t pe m 8.peratures activated? 2 N keO y pSI rG esN sA esL ais n v yi msi ob rle e on the screen, no reaction on Feature: Description: Factory Pre-Set: Feature: Description: Factory Pre-Set: a bIs e t h ve is r ibe lc ee )iver powered? (Red signal lamp should Programme On & Off times for the current period can be Help Tips Describes the button functions b GIs uth ide e r o Sto em p t 9h .ermostat powered? see Homeowner Timetable modified. See description in ‘Step 4’ Holiday switch In the period until holiday starts the product will operate normally.If holiday 3 LOCKED is displayed on the room themostat Copy days Will copy the current day to one or more other days off is disabled manually or terminates automatically, the mode before start of holiday will be re-instated.An enabled holiday will be indicated with a Add Period Adds a Time event. It will be added at the correct suitcase symbol in the top line. If holiday is active, in the Set: line the holiday a see Installation Guide Step 8 - Screen Lock position within the day. There is a maximum of 4 end date will be indicated. In the Summary screen the suitcase will be visible periods. together with the holiday temperature. 4 Is the battery symbol visible? Remove Period Removes the selected period. There needs to be at Status Enable or disable holiday mode. Disabled a Replace batteries, see Homeowner Guide Step 9. least 1 period Change The visible day-blocks available in "programme Zones aH lo l zli od na ey s mode can be applied to a specific zone or All zones 5 S reT aA cR tiT oI nN oG n i s k evi ys i pb rl ee s o sen st h ae n yth me or rm eostat screen, no Timetable Type timetable" can be defined, see Step 4 Holiday start Set the time for the start of your holiday Current time - a I bs e t h ve is r ibe lc ee )iver powered? (Red signal lamp should Individual days Each day can be programmed individually time (From) nearest hour Week and Mon… Fri and Sat… Sun can be programmed as 2 Default Holiday start Set the date for the start of your holiday Today 6 W onA kI eT yi s p v ri es sib sele s o an n yth me o t rh eermostat screen, no reaction weekend blocks date (From) All week Mon…Sun can be programmed as one block Holiday end time Set the time for the end of your holiday Current time - a bIs e t h ve is r ibe lc ee )iver powered? (Red signal lamp should (To) nearest hour Stored MiTime contains 3 pre-set programmes. These Programme 1 programmes programmes can be modified according to personal Holiday end date Set the date for the end of your holiday Today + 1 week needs and can be stored by using a name. Via this (To) name they can also be re-loaded. Once a programme Time and date settings has been modified, the original factory pre-set will no longer be available unless a System Reset is applied - Set time To set time of day Factory set see Installation Guide Step 4. Set date To set date Factory set Load stored A pre-set programme can be loaded programme Daylight saving To enable or disable daylight saving Enabled Save current The current programme can be saved by name (Each Clock format To select 12h or 24h clock mode 12hr programme pre-set program includes: Individual days, week/ weekend, all day and custom day schedules) Stored programmes MiTime contains 3 pre-set programmes. An example is shown below. These programmes can be modified according to personal needs and can be stored by using a name. Via this name they also can be reloaded. Once a programme has been modified, the original factory pre-set will no longer be available. On a System Reset, only the current loaded programme will be replaced with the factory setting – see Installation Guide Step 4. Programme 1 All week Week & Weekend Example: Mon-Sun Mon-Fri Sat-Sun 1st On 6:30am 6:30am 7:00am 1st Off 8:30am 8:30am 9:00am 2nd On 4:30pm 4:30pm 4:00pm 2nd Off 10:30pm 10:30pm 11:00pm Step 7: Keys and Display - MiStatStep 8: +hr (Boost)Step 9: Changing the Batteries
Drayton MiTime Programmer Series — How to replace the batteries diagram (page 2)
Fig. 6 · How to replace the batteries
Drayton MiTime Programmer Series — How to replace the batteries diagram (page 2)
Fig. 7 · How to replace the batteries
Drayton MiTime Programmer Series — How to replace the batteries diagram (page 2)
Fig. 8 · How to replace the batteries
Drayton MiTime Programmer Series — How to replace the batteries diagram (page 2)
Fig. 9 · How to replace the batteries
1Setting temperature values is restricted a A ser ee IM nsin taim llau tm io/ nM Ga ux ii dm eu Sm te t pe m 8.peratures activated? 2NO SIGNAL is visible on the screen, no reaction on key presses anymore a bIs e t h ve is r ibe lc ee )iver powered? (Red signal lamp should b GIs uth ide e r o Sto em p t 9h .ermostat powered? see Homeowner 3LOCKED is displayed on the room themostat a see Installation Guide Step 8 - Screen Lock 4Is the battery symbol visible? a Replace batteries, see Homeowner Guide Step 9. 5STARTING is visible on the thermostat screen, no reaction on key presses anymore a I bs e t h ve is r ibe lc ee )iver powered? (Red signal lamp should 6WAIT is visible on the thermostat screen, no reaction on key presses anymore a bIs e t h ve is r ibe lc ee )iver powered? (Red signal lamp should
Feature:Description:Factory Pre-Set: Programme TimetableOn & Off times for the current period can be modified. See description in ‘Step 4’ Copy daysWill copy the current day to one or more other days Add PeriodAdds a Time event. It will be added at the correct position within the day. There is a maximum of 4 periods. Remove PeriodRemoves the selected period. There needs to be at least 1 period Change Timetable TypeThe visible day-blocks available in "programme timetable" can be defined, see Step 4 Individual daysEach day can be programmed individually Week and weekendMon… Fri and Sat… Sun can be programmed as 2 blocksDefault All weekMon…Sun can be programmed as one block Stored programmesMiTime contains 3 pre-set programmes. These programmes can be modified according to personal needs and can be stored by using a name. Via this name they can also be re-loaded. Once a programme has been modified, the original factory pre-set will no longer be available unless a System Reset is applied - see Installation Guide Step 4.Programme 1 Load stored programmeA pre-set programme can be loaded Save current programmeThe current programme can be saved by name (Each pre-set program includes: Individual days, week/ weekend, all day and custom day schedules)
Description: Factory Pre-Set: Describes the button functions In the period until holiday starts the product will operate normally.If holiday is disabled manually or terminates automatically, the mode before start of holiday will be re-instated.An enabled holiday will be indicated with a suitcase symbol in the top line. If holiday is active, in the Set: line the holiday end date will be indicated. In the Summary screen the suitcase will be visible together with the holiday temperature. Enable or disable holiday mode. Disabled Holiday mode can be applied to a specific zone or All z all zonesones Set the time for the start of your holiday Curr nearent time - est hour Set the date for the start of your holiday Today Set the time for the end of your holiday Curr nearent time - est hour Set the date for the end of your holiday Today + 1 week To set time of day Factory set To set date Factory set To enable or disable daylight saving Enabled
All weekWeek & Weekend Mon-SunMon-FriSat-Sun 1st On6:30am6:30am7:00am 1st Off8:30am8:30am9:00am 2nd On4:30pm4:30pm4:00pm 2nd Off10:30pm10:30pm11:00pm

RF Pack: MiStat N110R, MiStat C110C How do I know when to change the batteries?

How to replace the batteries

Remove the battery covers as shown. Replace the batteries with 2 x 1.5V IEC LR6 (AA) Alkaline batteries ensuring correct orientation. Replace the battery covers pressing fully home.

RF transmission indication. The RF symbol will be visible as follows,

Call for heat indication. This flame will be visible when the room temperature is below the set temperature.

When the batteries start to run low a battery icon will flash in the display to indicate “low battery”, during this time the MiStat will function normally. When the battery icon alone is alone is shown in the display, the batteries are completely exhausted and the MiStat will cease to function (see below). Re-activate by replacing the batteries.

Short flashes indicates an RF transmission.

Current Setting, see table below

Long flashes indicates an RF transmission issue.

key: Press to toggle between Comfort setting, Eco setting and Home (Room thermostat only). See table below.

Press +hr to Boost

+hr key: Press to add up to 3 hours to the current period or to get instant 1 to 3 hours if currently off (see step 8).

keyPress to cancel +hr and display home. (Cylinder thermostat only)
Battery CoversSlide outwards to remove
+ & - keysPress to change the current temperature or turn the heat on if currently off
Select keyPress to open and save editor screens

Drayton

Battery Handling

Press +/- to adjust +hr period between 0 and 3 hours Press ( ) to confirm

Batteries, rechargeable or not, should not be disposed of into ordinary household waste. Instead, they must be recycled properly to protect the environment and cut down the waste of precious resources.

Now the Boost is running. The time will be counted down each hour.

Comfort setting Selects the comfort setting. The pre-set value is used each time when activated, adjustable within the menu

Once the time has elapsed, control returns to the prior temperature screen.

Your local waste management authority can supply details concerning the proper disposal of batteries.

Eco setting Selects the Eco setting. The pre-set value is used each time when activated, adjustable within the menu.

The Boost can be cancelled by pressing the ( ) key or by setting the +hr period to 0.

In compliance with the EU Directive 2006/66/EC, the button cell battery located on the printed circuit board inside the product, can be removed at the end of the product life, by professional personnel only.

None Home screen Indicates that the pre-set temperatures were changed via +/- key

Show 15 more labels / short text on this page
Current room temperature · MiStat Rear · Drayton · Current set temperature · MiStat · Drayton · Drayton · MiStat · MiStat · MiStat · Symbol in display · Function Description · Drayton · MiStat · Drayton

Ask about the Drayton MiTime Programmer Series

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Drayton MiTime Programmer Series

Be the first to ask — other owners or our team will answer.

Original document

Drayton MiTime Programmer Series manual PDF

2 pages·985 KB·Programmer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…