Rated voltage115V Rated power: 295 ~ 690W Frequency: 60Hz Moisture removal: 30 ~ 70 Pints/day

version A - 09 - 2018 www.midea.com

en

Page 2 of the Midea Dehumidifier user manual — Owner’s Manual
Page 2 · click to enlarge
Page 2

Owner’s Manual

Unit Specifications and Features ................................................... 6

Installation Instructions ................................................................... 13

Care and Cleaning ........................................................................... 14

Troubleshooting Tips ....................................................................... 15

Read This Manual

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the troubleshooting tips - you should be able to fix most of them quickly before calling service. These instructions may not cover every possible condition of use, so common sense and care for safety is required when installing, operating and maintaining this product.

  • Contact an authorized service technician for repair or maintenance of this unit.
  • The unit is not designed to be used by young children or people with reduced physical, sensory or mental capabilities without supervision.
  • Young children should be supervised to ensure that they do not play with the unit.
  • If the power cord needs to be replaced, please contact our consumer service or an authorized technician.
  • Electrical installation, if needed, must be performed in accordance to national regulation standards by qualified personnel only.
Page 3 of the Midea Dehumidifier user manual — WARNING
Page 3 · click to enlarge
Page 3

To prevent injury to the user or personal and property damage, these instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The level of risk is shown by the following indications.

This symbol indicates the possibility of death or serious injury.

WARNING

This symbol indicates the possibility of injury or damage to property.

WARNING

  • Plug in power plug properly. Otherwise, it may cause electric shock or fire due to excess heat generation.
  • Do not modify power cord length or share the outlet with other appliances. It may cause electric shock or fire due to overheating.
  • Always ensure effective grounding. Incorrect grounding may cause electric shock.
  • Unplug the unit if strange sounds, smells, or smoke come from it. A damaged product may cause fire and electric shock.
  • Ventilate room before operating the unit if there is a gas leak from other appliances.
  • Do not operate or stop the unit by inserting or pulling out the power plug. It may cause electric shock.
  • Do not allow water to enter into electric parts. It may cause failure or electric shock.
  • Do not use the power outlet if it is loose or damaged. It may cause fire and electric shock.
  • Do not use or keep the power cord close to heating appliances or heat sources such as fireplaces. It may cause fire and electric shock.
  • Do not disassemble or modify unit. It may cause failure and electric shock.
  • Do not damage or use an unspecified power cord. It may cause fire and electric shock.
  • If the power cord is damaged, it must be replaced by the manufacturer or an authorized service center or a similarly qualified person in order to avoid electrical risk.
  • Do not use the unit near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause fire.
  • Before cleaning, turn off the power and unplug the unit.
  • Do not remove the water bucket during operation, the bucket full protection may be activated and risk electric shock.
Page 4 of the Midea Dehumidifier user manual — WARNING
Page 4 · click to enlarge
Page 4
  • Do not use the unit in small spaces. Lack of ventilation can cause overheating and fire.
  • Do not use in places where water may splash onto the unit. Water may enter the unit and degrade the insulation. It may cause an electric shock or fire.
  • Place the unit on a level, sturdy section of the floor. If the unit falls over, it may cause water to spill and damage belongings, or cause electrical shock or fire.
  • Never insert your finger or other foreign objects into grills or openings. Take special care to warn children of these dangers. It may cause failure or electric shock.
  • Do not climb up on or sit on the unit. You may be injured if you fall or if the unit falls over.
  • Always insert the filters securely, and take caution to avoid injuries to hand and fingers. Clean filter once every two weeks.
  • If water enters the unit, turn the unit off and disconnect the power, contact a qualified service technician.
  • Do not place flower vases or other water containers on top of the unit. Water may spill inside the unit, causing insulation failure and electrical shock or fire.
  • If the unit is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact customer service or a qualified technician.
  • In a thunderstorm, the power should be disconnected to the unit due to lightning.
  • Do not run power cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
Page 5 of the Midea Dehumidifier user manual — WARNING
Page 5 · click to enlarge
Page 5
  • The manufactures nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit.
  • Be sure the unit is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
  • Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
  • Ensure the receptacle is accessible after the unit installation.
  • To avoid the possibility of personal injury, always disconnect the the unit from power supply, before installing and/or servicing.
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prongs from the power cord.
Page 6 of the Midea Dehumidifier user manual — Accessories
Page 6 · click to enlarge
Page 6
Midea Dehumidifier — Accessories diagram (page 6)
Fig. 2 · Accessories

Re ar F r o n t

Midea Dehumidifier — Accessories diagram (page 6)
Fig. 3 · Accessories
Midea Dehumidifier — Accessories diagram (page 6)
Fig. 4 · Accessories

Air filter (behind the grill)

Continuous drain hose outlet

Water bucket Water level window

Power cord buckle (placed in the water bucket, used only when storing the unit.) Installed as shown below

hose outlet (on some models)

Power cord Power plug

Midea Dehumidifier — Accessories diagram (page 6)
Fig. 5 · Accessories

All the pictures in this manual are for illustrative purposes only. The actual shape of the dehumidifier you purchased may be slightly different, but its operations and functions are similar.

Insert the power cord buckle into the unit.

Accessories

Pump drain hose (1 pc) (only for units with the drain pump feature)

Midea Dehumidifier — Accessories diagram (page 6)
Fig. 6 · Accessories
Show 7 more labels / short text on this page
Handle (both sides) · Control panel · Air outlet · Panel · Air intake · Pump drain · Caster
Page 7 of the Midea Dehumidifier user manual — Control Pads
Page 7 · click to enlarge
Page 7
Midea Dehumidifier — defrost full diagram (page 7)
Fig. 7 · defrost full

Clean your unit occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.

Continuous operation on indicator light Auto defrost operation on indicator light

Comfort dehumidifying operation on indicator light

Bucket full indicator light

High fan indicator light

Timer on/off indicator light

Clean filter indicator light

defrost full

timer

The appearance of the control panel on your unit may vary slightly. Functions will be similar.

Control Pads

When you push the button to change operation modes, the unit will make a beep sound to indicate that it is changing modes.

Make sure the pump drain hose is installed into the unit and the continuous drain hose is removed from the unit before the pump operation is activated. When the bucket is full, the pump starts to work. Refer to the next pages for removing the collected water. Do not use this operation when the outdoor temperature is equal to or less than 0°C (32°F).

Press to activate the pump operation.

Pump indicator light · LED Display · (PUMP) Button

Page 8 of the Midea Dehumidifier user manual — defrost full
Page 8 · click to enlarge
Page 8

For damper air, press the button and set a higher value (%).

Press to activate the comfort dehumidifying operation.

  • TIMER Set Control Buttons

Use the and key buttons to set the Timer ON or Timer OFF from 0 to 24 hours.

When COMFORT function is turned on, set humidity is automatic and cannot be changed manually.

(POWER) Button Press to turn the dehumidifier on and off. LED Display Shows the set % humidity level from 35% to 85% or auto start/stop time (0 ~ 24) while setting, then shows the actual (+/- 5% accuracy) room % humidity level in a range of 30% RH (Relative Humidity) to 90% RH (Relative Humidity).

This feature is a reminder to clean the Air Filter for more efficient operation. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the Filter button and the light will go off. The 250 hour counter will reset.

Error Codes and Protection Code:

AS - Humidity sensor error - Unplug

Press to activate the continuous dehumidifying operation.

the unit and plug it back in. If error persists, contact Customer Service.

ES - Tube Temperature sensor of the

evaporator error - Unplug the unit and plug it back in. If error persists, contact Customer Service.

When CONTINUOUS mode function is turned on, set humidity is automatic and cannot be changed manually.

P2 - Bucket is full or bucket is not in right

position - Empty the bucket and replace it in the right position. (only available for the unit with no pump feature.)

(TURBO) Button Control the Turbo speed. Press to select either Turbo or normal fan speed. Set the Turbo control to high for maximum moisture removal. When room humidity is at your preferred level, it is advised to turn off Turbo speed.

P2 - Bucket is full - Empty the bucket.

(only available for the unit with pump feature.)

EC - Refrigerant leakage detection -

Display area will show EC when the unit detects refrigerant leakage. If error persists, contact Customer Service.

Starts the Timer ON and Timer OFF function setting.

E3 - Unit malfunction - Unplug the unit

Up/Down Buttons ( / )

and plug it back in. If error persists, contact Customer Service.

  • Humidity Set Control Buttons The humidity level can be set within a range of 35% RH (Relative Humidity) to 85% RH (Relative Humidity) in 5% increments.

Eb - Bucket is removed or not in right

position - Replace the bucket in the right position. (only available for the unit with pump feature.)

For drier air, press the button and set to a lower value (%).

Show 4 more labels / short text on this page
(COMFORT) Button · (FILTER) Button · (CONTINUE) Button · (TIMER) Button
Page 9 of the Midea Dehumidifier user manual — NOTES
Page 9 · click to enlarge
Page 9
  • Press or hold the and key buttons to change the Timer by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start.

Other Features

Lights up when the bucket is ready to be emptied.

  • The selected time will register in 5 seconds and the system will automatically revert back to display the previous humidity setting.

The dehumidifier shuts off when the bucket is full, or when the bucket is removed or not replaced in the proper position. When the set point humidity level is reached, the unit will be shut off automatically. The fan motor will continue operating.

  • When the Timer ON and Timer OFF times are set, within the same program sequence, indicator lights illuminate identifying both ON and OFF times are now programmed.

When frost builds up on the evaporator coils, the compressor will cycle off and Auto Defrost function will run automatically.

  • Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Timer function.
  • When LED display window displays the code of P2, the Auto Start/Stop function will also be cancelled.

3 minute compressor operation delay protection

After the unit has stopped, it can not be restarted in the first 3 minutes to protect compressor operation. The unit will restart automatically after 3 minutes.

NOTES

  • When first using the dehumidifier, operate the unit continuously 24 hours. Make sure the plastic cover on the continuous drain hose outlet install stightly properly so there are no leaks.

If the unit stops unexpectedly due to a power cut, it will restart with the previous function setting automatically when the power resumes.

  • This unit is designed to operate with a working environment between 5°C/41°F and 35°C/95°F.

Setting the Timer ON and Timer OFF

  • When the unit is on, first press the Timer button, the Timer OFF indicator light illuminates. It indicates the Timer OFF program is initiated. Press it again the Timer ON indicator light illuminates. It indicates the Timer ON is initiated.
  • Make sure the water bucket is positioned correctly so that the unit can operate properly. When the water in the bucket reaches a certain level, please be careful while moving the unit to avoid it spill.
  • When the unit is off, first press the Timer button, the Timer ON indicator light illuminates. It indicates the Timer ON program is initiated. Press it again the Timer OFF indicator light illuminates. It indicates the Timer OFF is initiated.
Show 4 more labels / short text on this page
Bucket Full Light · Auto Shut Off · Auto Defrost · Auto-Restart
Page 10 of the Midea Dehumidifier user manual — NOTES
Page 10 · click to enlarge
Page 10

Removing Collected Water

There are three ways to remove collected water:

1. Use the bucket
  • When the unit is off, if the bucket is full, the Full indicator light will light.
1. Pull out the bucket.
  • When the unit is on, if the bucket is full, the compressor and the fan turn off, and the Full indicator light will light, the digital display shows P2.
  • Slowly pull out the bucket. Grip the left and right handles securely, and carefully pull out straight so water does not spill. Do not put the bucket on the as because the bottom of the bucket is uneven. Otherwise water may be spilled.
2. Hold both sides of the bucket evenly, and pull it out from the unit.
  • Empty the water and reposition the bucket.
  • The unit will restart operation when the bucket is back in place.

NOTES

  • When you remove the bucket, do not touch any parts inside the unit. Doing so may damage the product.
  • Be sure to push the bucket gently all the way into the unit.
3. Pour the water out.
  • If the pump hose falls off when you remove the bucket (see Fig. 7), you must reinstall the pump hose properly to the unit before replacing the bucket into the unit (see Fig. 8).
  • When the unit is on, if the bucket is removed, the compressor and the fan turn off, then the unit will beep 8 times and the digital display shows Eb.
  • When the unit is off, if the bucket is removed, the unit will beep 8 times and the digital display shows Eb.

Fig. 7 Pump hose drops

Reinstall pump hose properly

Page 11 of the Midea Dehumidifier user manual — Removing the Collected Water (cont.)
Page 11 · click to enlarge
Page 11
2. Continuous draining
  • Water can be automatically emptied into a floor drain by attaching the unit with a water hose (Id Ø 5/16”, not included) with a female threaded end (ID: M = 1”, not included).
  • Remove the plastic cover from the back drain outlet of the unit and set aside, then insert the drain hose through the drain outlet of the unit and lead the drain hose to the floor drain or a suitable drainage facility. (See Fig. 9 and Fig. 10)

Remove the plastic cover rotating counter-clockwise

  • When you remove the plastic cover, if there is some water in the back drain outlet of the unit you must dry it. Make sure the hose is secure so there are no leaks and the end of the hose is level or sloping downwards to let the water flow.
  • Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing.
  • Select the desired humidity setting and fan speed on the unit for continuous draining to start.

When the continuous draining feature is not being used, remove the drain hose from the outlet, and dry the water in the continuous drain hose outlet.

Removing the Collected Water (cont.)

3. Pump draining (Pump models only)

Water can be automatically emptied into a floor drain or a suitable drainage facility by attaching the pump drain out with a pump drain hose (Ø od = 1/4”, supplied).

Reinstall the plastic cover

  • Remove the continuous drain hose from the unit and install the plastic cover to the continuous drain hose outlet of the unit by clockwise rotation. (See Fig. 11)

Pump drain hose outlet

  • Insert the pump drain hose into the pump drain hose outlet for at least 15 mm (See Fig. 11), then lead the water hose to the floor drain or a suitable drainage facility.
  • Press the pump pad on the unit to activate the pump operation. When the bucket is full the pump starts to work.

Drain hose · Pump drain hose

Page 12 of the Midea Dehumidifier user manual — Removing the Collected Water (cont.)
Page 12 · click to enlarge
Page 12

The pump may generate a loud noise for the first 3~5 minutes of operation.

  • Make sure the hose is secure so there are no leaks.
  • Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing.
Midea Dehumidifier — Removing the Collected Water (cont.) diagram (page 12)
Fig. 8 · Removing the Collected Water (cont.)
  • Place the end of the hose into the drain.
  • Select the desired humidity setting and fan speed on the unit for pump draining to start.

The pump operation light blinks when a failure occurs. Please turn off the unit and disconnect the power cord. Check the following items:

  • Cleaning the pump filter: - Remove the bucket from the unit, take down the

pump and clean the pump filter (See Fig. 12).

Filter of the pump

  • Check if the drain hose is clean and free of debris.
  • Check the hose connection and the bucket for proper fitment. If the error persists, contact Customer Service.
Midea Dehumidifier — Removing the Collected Water (cont.) diagram (page 12)
Fig. 9 · Removing the Collected Water (cont.)

Do not use this operation when the outdoor temperature is equal to or less than 0°C (32°F), otherwise water may freeze ice causing the water hose to be blocked and the unit to stop operating.

Make sure to empty the bucket at least once a week a week when using the pump draining feature. When the pump draining feature is not being used, remove the pump drain hose from the outlet.

Page 13 of the Midea Dehumidifier user manual — Removing the Collected Water (cont.)
Page 13 · click to enlarge
Page 13
Midea Dehumidifier — Removing the Collected Water (cont.) diagram (page 13)
Fig. 10 · Removing the Collected Water (cont.)

A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. (See Fig. 13)

  • Do not use outdoors.
Midea Dehumidifier — Removing the Collected Water (cont.) diagram (page 13)
Fig. 11 · Removing the Collected Water (cont.)
  • This dehumidifer is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications.
  • Place the dehumidifier on a smooth, level floor strong enough to support the unit with a full bucket of water.
  • Allow at least 8” of air space on all sides of the unit for air circulation (at least 16” for air outlet).
  • Place the unit in an area where the temperature will not fall below 41°F (5°C). The coils can become covered with frost at at lower temperatures, which may reduce performance.
  • Place the unit away from any clothes dryer, heater or radiator.
  • Close all doors, windows and other outside openings to the room.
Page 14 of the Midea Dehumidifier user manual — Removing the Collected Water (cont.)
Page 14 · click to enlarge
Page 14
Midea Dehumidifier — Removing the Collected Water (cont.) diagram (page 14)
Fig. 12 · Removing the Collected Water (cont.)

Turn the dehumidifier off and disconnect the plug from the power source before cleaning.

1. Clean the Grill and Case
  • Use water and a mild detergent. Do not use bleach or abrasives.
  • Do not splash water directly onto the unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
  • The air intake and outlet may get dirty during operation, use a vacuum cleaner or brush to clean.
2. Clean the bucket

Every few weeks, clean the bucket thoroughly to prevent growth of mold, mildew and bacteria. Partially fill the bucket with clean water and mild detergent. Swish it around in the bucket, empty and rinse.

Midea Dehumidifier — Removing the Collected Water (cont.) diagram (page 14)
Fig. 13 · Removing the Collected Water (cont.)

Do not use a dishwasher to clean the bucket.

Midea Dehumidifier — Removing the Collected Water (cont.) diagram (page 14)
Fig. 14 · Removing the Collected Water (cont.)
  • To remove the filter, pull filter outwards (See Fig. 14).
  • Wash the filter with clean water then dry.

DO NOT operate the dehumidifier without a filter to avoid loss of performance and damage to the unit.

4. When not using the unit for long time periods
  • Before storing the unit, let it rest for one full day so that the system can dry out naturally.
  • Clean the unit, water bucket and air filter.
  • Wrap the cord with the power cord buckle.
  • Cover the unit with a plastic bag.
  • Store the unit upright in a dry, well-ventilated area.
Page 15 of the Midea Dehumidifier user manual — 5 Troubleshooting Tips
Page 15 · click to enlarge
Page 15

5 Troubleshooting Tips

Before calling for service, review this list. It may save you time and money. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

Make sure the dehumidifiers plug is connected firmly into the wall outlet. Check the house fuse/circuit breaker box. Dehumidifier has reached its preset level or bucket is full. Water bucket is not in the proper position.

Unit does not start

Not enough time to remove the moisture. Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier. The humidity control may not be set low enough. Check that all doors, windows and other openings are securely closed. Room temperature is too low, below 5°C (41°F). There is a water vapor source in the room.

Dehumidifier does not dry the air as it should

The unit makes a loud noise when operating

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. The unit is tilted instead of upright as it should be. The floor surface is not level. Frost appears on the coils This is normal. The dehumidifier has Auto defrost feature.

Hose to connector or hose connection may be loose. Intended to use the bucket to collect water, but the back drain plug is removed. ES, AS, P2, EC, Eb and E3 appear in the display

These are error codes and protection code. Check Operating Instructions.

The pump operation on light blinks at 1 Hz

Clean the pump filter. Check the pump hose is not blocked or leaking.

Empty the water bucket.

Problem Solution · Troubleshooting Tips · Water on floor

Page 16 of the Midea Dehumidifier user manual — 5 Troubleshooting Tips
Page 16 · click to enlarge
Page 16
Page 16 of the Midea Dehumidifier user manual — 5 Troubleshooting Tips
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
P2Bucket is full or bucket is not in right p.8
E3Unit malfunction - Unplug the unit p.8
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Unit does not startMake sure the dehumidifiers plug is connected firmly into the wall outlet. p.15
Unit does not startCheck the house fuse/circuit breaker box. p.15
Unit does not startDehumidifier has reached its preset level or bucket is full. p.15
Unit does not startWater bucket is not in the proper position. p.15
Dehumidifier does not dry the air as it shouldNot enough time to remove the moisture. p.15
Dehumidifier does not dry the air as it shouldMake sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier. p.15
Dehumidifier does not dry the air as it shouldThe humidity control may not be set low enough. p.15
Dehumidifier does not dry the air as it shouldCheck that all doors, windows and other openings are securely closed. p.15
Dehumidifier does not dry the air as it shouldRoom temperature is too low, below 5°C (41°F). p.15
Dehumidifier does not dry the air as it shouldThere is a water vapor source in the room. p.15
The unit makes a loud noise when operatingAir filter may be dirty. Clean filter. Refer to Care and Cleaning section. p.15
The unit makes a loud noise when operatingThe unit is tilted instead of upright as it should be. p.15
The unit makes a loud noise when operatingThe floor surface is not level. p.15
Frost appears on the coilsThis is normal. The dehumidifier has Auto defrost feature. p.15
Water on floorHose to connector or hose connection may be loose. p.15
Water on floorIntended to use the bucket to collect water, but the back drain plug is removed. p.15
ES, AS, P2, EC, Eb and E3 appear in the displayThese are error codes and protection code. Check Operating Instructions. p.15
The pump operation on light blinks at 1 HzClean the pump filter. p.15
The pump operation on light blinks at 1 HzCheck the pump hose is not blocked or leaking. p.15
The pump operation on light blinks at 1 HzEmpty the water bucket. p.15

Ask about the Midea Dehumidifier

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Midea Dehumidifier

Be the first to ask — other owners or our team will answer.

Original document

Midea Dehumidifier manual PDF

16 pages·3.1 MB·Household Appliance·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…