version A - 09 - 2018 www.midea.com
en

Unit Specifications and Features ................................................... 6
Installation Instructions ................................................................... 13
Care and Cleaning ........................................................................... 14
Troubleshooting Tips ....................................................................... 15
Read This Manual
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the troubleshooting tips - you should be able to fix most of them quickly before calling service. These instructions may not cover every possible condition of use, so common sense and care for safety is required when installing, operating and maintaining this product.

To prevent injury to the user or personal and property damage, these instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The level of risk is shown by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.




Re ar F r o n t


Air filter (behind the grill)
Continuous drain hose outlet
Water bucket Water level window
Power cord buckle (placed in the water bucket, used only when storing the unit.) Installed as shown below
hose outlet (on some models)
Power cord Power plug

All the pictures in this manual are for illustrative purposes only. The actual shape of the dehumidifier you purchased may be slightly different, but its operations and functions are similar.
Insert the power cord buckle into the unit.
Pump drain hose (1 pc) (only for units with the drain pump feature)



Clean your unit occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.
Continuous operation on indicator light Auto defrost operation on indicator light
Comfort dehumidifying operation on indicator light
Bucket full indicator light
High fan indicator light
Timer on/off indicator light
Clean filter indicator light
timer
The appearance of the control panel on your unit may vary slightly. Functions will be similar.
When you push the button to change operation modes, the unit will make a beep sound to indicate that it is changing modes.
Make sure the pump drain hose is installed into the unit and the continuous drain hose is removed from the unit before the pump operation is activated. When the bucket is full, the pump starts to work. Refer to the next pages for removing the collected water. Do not use this operation when the outdoor temperature is equal to or less than 0°C (32°F).
Press to activate the pump operation.
Pump indicator light · LED Display · (PUMP) Button

For damper air, press the button and set a higher value (%).
Press to activate the comfort dehumidifying operation.
Use the and key buttons to set the Timer ON or Timer OFF from 0 to 24 hours.
When COMFORT function is turned on, set humidity is automatic and cannot be changed manually.
(POWER) Button Press to turn the dehumidifier on and off. LED Display Shows the set % humidity level from 35% to 85% or auto start/stop time (0 ~ 24) while setting, then shows the actual (+/- 5% accuracy) room % humidity level in a range of 30% RH (Relative Humidity) to 90% RH (Relative Humidity).
This feature is a reminder to clean the Air Filter for more efficient operation. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the Filter button and the light will go off. The 250 hour counter will reset.
Error Codes and Protection Code:
AS - Humidity sensor error - Unplug
Press to activate the continuous dehumidifying operation.
the unit and plug it back in. If error persists, contact Customer Service.
ES - Tube Temperature sensor of the
evaporator error - Unplug the unit and plug it back in. If error persists, contact Customer Service.
When CONTINUOUS mode function is turned on, set humidity is automatic and cannot be changed manually.
P2 - Bucket is full or bucket is not in right
position - Empty the bucket and replace it in the right position. (only available for the unit with no pump feature.)
(TURBO) Button Control the Turbo speed. Press to select either Turbo or normal fan speed. Set the Turbo control to high for maximum moisture removal. When room humidity is at your preferred level, it is advised to turn off Turbo speed.
P2 - Bucket is full - Empty the bucket.
(only available for the unit with pump feature.)
EC - Refrigerant leakage detection -
Display area will show EC when the unit detects refrigerant leakage. If error persists, contact Customer Service.
Starts the Timer ON and Timer OFF function setting.
E3 - Unit malfunction - Unplug the unit
Up/Down Buttons ( / )
and plug it back in. If error persists, contact Customer Service.
Eb - Bucket is removed or not in right
position - Replace the bucket in the right position. (only available for the unit with pump feature.)
For drier air, press the button and set to a lower value (%).

Lights up when the bucket is ready to be emptied.
The dehumidifier shuts off when the bucket is full, or when the bucket is removed or not replaced in the proper position. When the set point humidity level is reached, the unit will be shut off automatically. The fan motor will continue operating.
When frost builds up on the evaporator coils, the compressor will cycle off and Auto Defrost function will run automatically.
3 minute compressor operation delay protection
After the unit has stopped, it can not be restarted in the first 3 minutes to protect compressor operation. The unit will restart automatically after 3 minutes.
If the unit stops unexpectedly due to a power cut, it will restart with the previous function setting automatically when the power resumes.
Setting the Timer ON and Timer OFF

There are three ways to remove collected water:
Fig. 7 Pump hose drops
Reinstall pump hose properly

Remove the plastic cover rotating counter-clockwise
When the continuous draining feature is not being used, remove the drain hose from the outlet, and dry the water in the continuous drain hose outlet.
Water can be automatically emptied into a floor drain or a suitable drainage facility by attaching the pump drain out with a pump drain hose (Ø od = 1/4”, supplied).
Reinstall the plastic cover
Pump drain hose outlet
Drain hose · Pump drain hose

The pump may generate a loud noise for the first 3~5 minutes of operation.

The pump operation light blinks when a failure occurs. Please turn off the unit and disconnect the power cord. Check the following items:
pump and clean the pump filter (See Fig. 12).
Filter of the pump

Do not use this operation when the outdoor temperature is equal to or less than 0°C (32°F), otherwise water may freeze ice causing the water hose to be blocked and the unit to stop operating.
Make sure to empty the bucket at least once a week a week when using the pump draining feature. When the pump draining feature is not being used, remove the pump drain hose from the outlet.


A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. (See Fig. 13)



Turn the dehumidifier off and disconnect the plug from the power source before cleaning.
Every few weeks, clean the bucket thoroughly to prevent growth of mold, mildew and bacteria. Partially fill the bucket with clean water and mild detergent. Swish it around in the bucket, empty and rinse.

Do not use a dishwasher to clean the bucket.

DO NOT operate the dehumidifier without a filter to avoid loss of performance and damage to the unit.

Before calling for service, review this list. It may save you time and money. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
Make sure the dehumidifiers plug is connected firmly into the wall outlet. Check the house fuse/circuit breaker box. Dehumidifier has reached its preset level or bucket is full. Water bucket is not in the proper position.
Unit does not start
Not enough time to remove the moisture. Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier. The humidity control may not be set low enough. Check that all doors, windows and other openings are securely closed. Room temperature is too low, below 5°C (41°F). There is a water vapor source in the room.
Dehumidifier does not dry the air as it should
The unit makes a loud noise when operating
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. The unit is tilted instead of upright as it should be. The floor surface is not level. Frost appears on the coils This is normal. The dehumidifier has Auto defrost feature.
Hose to connector or hose connection may be loose. Intended to use the bucket to collect water, but the back drain plug is removed. ES, AS, P2, EC, Eb and E3 appear in the display
These are error codes and protection code. Check Operating Instructions.
The pump operation on light blinks at 1 Hz
Clean the pump filter. Check the pump hose is not blocked or leaking.
Empty the water bucket.
Problem Solution · Troubleshooting Tips · Water on floor


Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Unit does not start | Make sure the dehumidifiers plug is connected firmly into the wall outlet. | p.15 | |
| Unit does not start | Check the house fuse/circuit breaker box. | p.15 | |
| Unit does not start | Dehumidifier has reached its preset level or bucket is full. | p.15 | |
| Unit does not start | Water bucket is not in the proper position. | p.15 | |
| Dehumidifier does not dry the air as it should | Not enough time to remove the moisture. | p.15 | |
| Dehumidifier does not dry the air as it should | Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier. | p.15 | |
| Dehumidifier does not dry the air as it should | The humidity control may not be set low enough. | p.15 | |
| Dehumidifier does not dry the air as it should | Check that all doors, windows and other openings are securely closed. | p.15 | |
| Dehumidifier does not dry the air as it should | Room temperature is too low, below 5°C (41°F). | p.15 | |
| Dehumidifier does not dry the air as it should | There is a water vapor source in the room. | p.15 | |
| The unit makes a loud noise when operating | Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. | p.15 | |
| The unit makes a loud noise when operating | The unit is tilted instead of upright as it should be. | p.15 | |
| The unit makes a loud noise when operating | The floor surface is not level. | p.15 | |
| Frost appears on the coils | This is normal. The dehumidifier has Auto defrost feature. | p.15 | |
| Water on floor | Hose to connector or hose connection may be loose. | p.15 | |
| Water on floor | Intended to use the bucket to collect water, but the back drain plug is removed. | p.15 | |
| ES, AS, P2, EC, Eb and E3 appear in the display | These are error codes and protection code. Check Operating Instructions. | p.15 | |
| The pump operation on light blinks at 1 Hz | Clean the pump filter. | p.15 | |
| The pump operation on light blinks at 1 Hz | Check the pump hose is not blocked or leaking. | p.15 | |
| The pump operation on light blinks at 1 Hz | Empty the water bucket. | p.15 |
Owners and our team usually reply within a day — and your question helps the next person too.