Offline lock user guide
Instructions for AD-Series offline locks





Para el idioma español, navegue hacia www.allegion.com/us Pour la portion française, veuillez consulter le site www.allegion.com/us



The Schlage AD-200/AD-201 is an off-line electronic lock in the AD-Series product line.
The Schlage AD-201 is a FIPS-201-1 certified off-line electronic lock.

Keypad Multi-Tech Reader Mag Card (Insert) Reader
Mag Card (Swipe) Reader
Inside Optional Inside Push Button (IPB)

Additional AD-200 reader options: Mag + Keypad, Multi-Tech + Keypad Note: Proximity card (PR, PRK) ONLY and Smart card (SM, SMK) ONLY readers have been discontinued and replaced by the Multi-Tech (MT, MTK) readers that provide all the same funcionality as the original Proximity and Smart card readers in a single credential reader.
The AD-201 reader is a FIPS-201-1 certified Multi-Tech + Keypad (FMK) reader.
This product is compliant of UL294 and ULC-S319 standard. This product’s compliance would be invalidated through the use of any add-on, expansion, memory or other module that has not yet been evaluated for compatibility for use with this UL Listed product, in accordance with the requirements of the Standards UL294 and ULC-S319. This product has been evaluated for CAN/ULC-S319 Class 1. UL294 Access Control Levels tested to: Destructive Attack - Level 1; Line Security - Level 1; Endurance - Level 4; Standby Power - Level 1.

The AD-200/AD-201 is available in one of four functions:
Privacy (40): Lockset is normally secure. Pressing the Inside Push Button or extending the deadbolt will disable normal electronic access from the outside. Opening the door, retracting the deadbolt or pressing the Inside Push Button a second time deactivates the privacy status.
Office (50): Lockset is normally secure. Inside Push Button may be used to select passage or secured status.
Apartment (60): Lockset is normally secure. Inside Push Button is used to select passage or secure status. While in the secure state, opening the door or pressing the Inside Push Button causes the lockset to toggle unsecured. The door must be closed and a valid credential presented to secure the lockset from the outside.
Classroom/Storeroom (70): Lockset is normally secure. Valid toggle credentials may be used to change to a passage or secure status.
Follow these steps when setting up a new lock.
1. Install the lock. See the installation guide that came with the lock, or visit www.allegion.com/us for more information. 2. Make sure the batteries are installed properly. See Batteries on page 17 for instructions. 3. Configure the master construction credential (where applicable). See Construction access mode on page 5 for more information. The lock should remain in construction access mode until you are ready to set up the rest of the system. 4. Test the lock for proper mechanical and electronic operation. See Test lock operation on page 14 for more information. 5. When ready to set up for normal use, program the user credentials. See Credential types and functions on page 6.
L Programming the lock with the SUS will remove all credentials that were added using the master construction credential. 6. Consult the SUS user guide for information about configuring the lock. 7. Familiarize yourself with the information in this guide.
Save this user guide for future reference.
The Schlage Utility Software is used for programming and setup only.
The SUS is used to configure locks. This includes transferring data files between the access control software and locks. For information about the SUS, refer to the SUS user guide.

Construction access mode is used to allow access before the lock has been programmed, and for testing purposes.
Locks with keypads – Construction access mode
In the factory default state, locks with keypads have a default PIN of 13579 and “#”, which can be used for installation, testing and construction access. To test, enter default PIN. The Schlage button will blink and the lock will unlock.
The default PIN, 13579 and “#” is automatically deleted when a construction access user credential is added to the lock, or a new programming credential is created, or the lock is programmed with the SUS.
Locks with card readers – Create a master construction credential
The master construction credential is used to program construction access mode credentials.
To create a master construction credential:
L The master construction credential will not grant access. It is used only to add additional credentials.
Locks with card readers – Add construction access mode user credentials

Cancel construction access mode
Do one of the following:
When construction mode is cancelled, the master construction credential and all other credentials added using the master construction credential will no longer function.
Programming credential: A card or 5 digit code used only for lock programming.
Card or PIN credentials: A card that is presented, or a 3-6 digit code entered on the keypad.
Card ID number: When adding any new card credential, a 3-6 digit code is entered prior to presenting the card. This code becomes the Card ID Number. This number can be used to delete a card credential without physically having the card. Keep a log of all Card ID Numbers for future reference.
Normal, toggle, freeze and pass-through credential types are used in one of three forms:
PIN credential – a 3-6 digit code entered on the keypad. CARD credential – a card presented to the lock. CARD + Card ID Number credential – a card (with a unique Card ID number) presented to the lock. (See a description of Card ID number above for more information.)
Steps for designating each form are in the Manual programming instructions on the following pages.
Credential forms

L Wait for the Schlage button LEDs to stop flashing before continuing to the next step.
L Programming mode will time out if no entry is made in 20-25 seconds. Time out is indicated by three left and nine right red blinks of the Schlage button.
L An incorrect entry is indicated by a solid red left and blinking green right LED on the Schlage button. Refer to Error codes on page 13 to interpret error code patterns.
L A unique credential must be used for each credential type (for example, a single credential may not be used for both normal use and toggle functions).
PROGRAMMING credentials

L Note: Before creating any credential in the following steps, determine which credential form is desired (see Credential forms on page 6).

NORMAL USE credentials

L Note: Before creating any credential in the following steps, determine which credential form is desired (see Credential forms on page 6).

TOGGLE credentials

L Note: Before creating any credential in the following steps, determine which credential form is desired (see Credential forms on page 6).

FREEZE credentials

L Note: Before creating any credential in the following steps, determine which credential form is desired (see Credential forms on page 6).

PASS THROUGH credentials


OTHER programming

L All error codes are indicated on the Schlage button by a solid red left LED, and a blinking green right LED. The number of green blinks indicates the error code.
Number of green blinks Error code description
1 Computer programming error (not complete).
2 Too long programming/user code entered. Programming code must be five (5) digits. User code length cannot exceed six (6) digits. 3 Memory full, too many codes. Delete some codes. 4 Programming code cannot be deleted, only changed.
5 Programming code entries do not match. Programming code not changed. 6 Invalid command. Invalid function code entered. 7 Code not found.
8 Code too short. Programming code length must be five (5) digits. User code minimum length is three (3) digits. 9 Not a unique code. 10 Manual programming not allowed.
Red Left LED · Green Right LED

If you encounter problems while performing any of the following tests, review the installation guide and correct any problems.
Test the AD-200/AD-201 in factory default mode
1. For locks with a keypad, press any number key. The lock will beep. 2. Press the Schlage button. The keypad should light blue for a few seconds. 3. For locks with a card reader, present a credential to the reader. The lock will beep and the left side of the Schlage button will blink red one time. When the lock is in factory default mode, no credentials are accepted. 4. In the factory default state, locks with keypads, with or without additional credentials, have a default PIN of 13579 and “#”. To test, enter the default PIN. The Schlage button will blink and the lock will unlock.
Test the AD-200/AD-201 in construction access mode
1. When the master construction credential is presented, the lock will beep and the Schlage button will light green for 20 seconds awaiting the presentation of another credential to be granted Construction User Access. 2. When a valid construction access user credential is presented, the lock will unlock for the re-latch delay period (default three seconds), and the left side of the Schlage button will blink green. When the lock relocks after the relock delay period, the left side of the Schlage button will blink red. 3. If an invalid construction access user credential is presented, the lock will beep and the left side of the Schlage button will blink red one time. For more information, see Construction access mode on page 5.
L NOTE: Construction access mode is cancelled when the lock is reset to factory defaults. When construction access mode is cancelled, the master construction credential and all other credentials added using the master construction credential will no longer function.
After credentials have been programmed, present credentials to operate the lock as follows:
PIN or Card Present or enter credential to reader Green blink Access granted
Present credential to reader Press Card
ID Number1 Green blink Access granted
1 The default PIN/Card ID length is six digits. The “#” key must be used as an ENTER key for PINs/Card IDs with fewer than six digits. PIN/Card ID length can be manually configured (refer to Change PIN or Card ID Number length on page 12).

System and hardware requirements
Switch specifications, wire specifications and routing
23394042 REV F Hardware revision letter
DPS
wires to latch bolt terminals
LATCH
BOLT
Wired remote release operation
Wired remote release button action
Attach the switch

All information in the lock will be deleted and reset to factory defaults!
Level 1 factory default reset
L Level 1 factory default reset will delete configurations and settings in the main controller in the lock.
L Main controller configurations that will reset to factory default include: programming and user codes.
L Level 1 factory default reset will not reset configurations and settings in the reader. 1. Remove the top inside cover. 2. Press and hold the Schlage button until two (2) beeps sound (10 seconds). 3. Release the Schlage button. 4. Press and release the inside push button (IPB) three (3) times within 10 seconds. One beep will sound and one red blink will occur with each press. 5. The Schlage button and IPB will both light green for one second and a one-second beep will be heard. This indicates that the lock has been reset.
L If the IPB is not pressed 3 times within 10 seconds, two beeps with two red blinks indicate timeout. 6. Replace the top inside cover.
Level 2 factory default reset
L Level 2 factory default reset will delete all configurations and settings in the lock and the reader.
L Reader configurations that will reset to factory default include: keypad format, magstripe reader track, beeper on/off, and contactless card.
L Days in Use counter and lock type configurations will not reset.
To complete Level 2 factory default reset, repeat steps 2 through 5 above within 10 seconds of the confirmation signals of Level 1 factory default reset. If more than 10 seconds pass after the confirmation signals of Level 1 reset, then Level 1 reset will be repeated.

To install or replace batteries
L Replacement of batteries does not affect any programmed data.
L Battery voltage can be checked with the SUS.

This product has been evaluated for ULC-S319 compliance with AA and coin cell batteries listed below. For installations requiring ULC-S319, these battery models should be used.
Coin cell batteries: Energizer CR2025, CR2032; Maxell CR2025, CR2032, Panasonic CR2025, CR2032; RayoVac KECR2025, KECR2032.

L During low battery condition, the reader’s beeper will be temporarily disabled. This condition will revert to normal function when batteries (AA or coin cell) are replaced. (While the beeper is in temporary disabled state, the SUS will indicate beeper is “on” as previously set by the user.)

Condition Indicator Solution Batteries low After credential is presented, 9 red blinks of Schlage button. (Left = AA, Right = Coin Cell), then normal indicator.
Replace batteries immediately to avoid battery failure. Lock is intended to operate for 500 cycles in low battery condition.
Replace batteries immediately. Mechanical override key must be used to unlock the lock.
L The battery failure mode is set using the SUS. See the SUS User Guide for more information.
Mode Description Fail As-Is (default) Lock remains in current state until batteries are replaced. Fail Unlocked1 Lock unlocks and remains unlocked until batteries are replaced. Fail Locked1 Lock locks and remains locked until batteries are replaced.
1 Fail Unlocked and Fail Locked modes are not available if the lock is externally powered.

The AD-200/AD-201 may be connected to external power using a UL294 listed power supply for UL installations, and a power supply that complies with CAN/UL-S318 or CAN/ULC-S319 for cUL installations. The power supply must be capable of sourcing at least 250mA @ 12 or 24 VDC (Schlage PS902, PS904, PS906).
L When powered with external power supply, the lock will always fail “As-Is” if power is lost.
Low battery indications · Battery failure modes

Most LED and beep indicators are configured using the SUS. See the SUS user guide for more information.
Condition Lights Access denied 2 red blinks Access denied, user outside time zone 4 red blinks Valid PIN entered while lock in freeze mode 12 red blinks indicating lockout Factory default reset Solid red while clearing memory, then a one-second solid green when complete. Waiting for Card ID Number (Card + Card ID Number)
5 left red with right green blinks, then solid right green Low battery indicator, AA batteries 9 left red blinks Low battery indicator, coin cell battery 9 right red blinks Momentary unsecured access 1 green blink, then one red blink on relock Toggle unsecured 2 green blinks Toggle secure (relocking) 1 red blink SUS authentication Left green solid USB active with no physical connection Left green blinking Occupancy indicator fast blinks are enabled 1 red blink every 1.5 seconds* Occupancy indicator slow blinks are enabled Sequential 1 red blink on both left and right every 1.5 seconds*
* The red blinks will turn amber if the lock’s battery is low.
Optional Inside Push Button (IPB)

Action Lights Classroom, Office or Apartment Mode Press IPB to lock 1 red blink Press IPB to unlock 1 green blink Privacy Mode With door closed, press IPB to engage privacy 4 red blinks With door closed, press IPB to release privacy1 4 green blinks With offline lockdown configuration enabled, press IPB for 4 seconds to activate lockdown2
With offline lockdown configuration enabled, press IPB for 4 seconds to deactivate lockdown
1 If DPS is used, then opening the door will also release privacy. If mortise deadbolt is used, then retracting the deadbolt will also release privacy. 2 Opening of door or deadbolt retraction will not deactivate the offline lockdown mode when it is active.
Optional Inside Push Button (IPB)
Condition Lights Occupancy indicator blinks fast mode/slow mode
1 red blink every 3 seconds*
Offline lockdown active 1 red blink every 10 seconds
* The red blinks will turn amber for the occupancy indicator blinks when the lock’s battery is low.
Schlage button

Problem Possible cause Solution The lock beeper does not sound and the keypad does not light when the Schlage button is pressed.
The reader may not be properly seated into the front escutcheon.
Check that the reader is fully seated into the front escutcheon.
Check that there are no bent pins in the reader connector.
The reader connector may have bent pins.
Check that the through door ribbon cable is plugged in correctly. The red wire should be on the left and not pinched in the door.
The through door ribbon cable may not be properly plugged in.
The battery or wired power may be improperly connected.
Check that the battery or wired power is connected correctly.
Check that the batteries are inserted in the correct polarity.
The batteries may be inserted with incorrect polarity.
Refer to the installation instructions that came with the AD-200/AD-201 lock, or this user guide for details on the above mentioned procedures. The reader is not working.
The through hole ribbon cable may be pinched.
Check that the through hole ribbon cable is not pinched.
The Smart card is not reading.
The Smart card default of the card reader may not be correct for the Smart card.
Change the Smart card format using the SUS. Select AD-200/AD-201 “Lock Properties”, “Reader” tab, and “Smart cards in use”.
The magnetic swipe card is not reading correctly (no beeps or blinks).
The “Mag Track in Use” default for all Magnetic Card Credential Readers is “Track2”. The magnetic swipe card data may be on Track1 or Track3.
Use the SUS to change “Mag Track in Use”. Select AD-200/AD-201 “Lock Properties”, “Reader” tab, and “MAG Card Track selection”.
Refer to the installation instructions that came with the AD-200/AD-201 lock, or the SUS user guide for details on the above mentioned procedures.
Wired remote release feature is not working.
The lock may not be compatible with remote release.
Wired remote release is available only on the AD-200/AD-201 storeroom function.
The hardware or firmware version may not be compatible with remote release.
Wired remote release is compatible with hardware version F or higher, and with locks programmed with AD-200/ AD-201 version 2.45.1 firmware or higher.
The lock’s inside cover may not be properly or completely installed.
Check that the inside cover is completely and properly installed.
The remote release switch may not be functioning correctly.
Check that the switch closes and delivers less than 5 ohms resistance when activated.

Allegion Agency statements Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
FCC interference statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Industry Canada statements This equipment has been tested and found to comply to Industry Canada ICES-003. CAN ICES-3(B)/NMB-3(B)

© Allegion 2020 P516-129 Rev. 04/20-p
1-877-671-7011 www.allegion.com/us
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The lock beeper does not sound and the keypad does not light when the Schlage button is pressed. | The reader may not be properly seated into the front escutcheon. The reader connector may have bent pins. The through door ribbon cable may not be properly plugged in. The battery or wired power may be improperly connected. The batteries may be inserted with incorrect polarity. | Check that the reader is fully seated into the front escutcheon. Check that there are no bent pins in the reader connector. Check that the through door ribbon cable is plugged in correctly. The red wire should be on the left and not pinched in the door. Check that the battery or wired power is connected correctly. Check that the batteries are inserted in the correct polarity. Refer to the installation instructions that came with the AD-200/AD-201 lock, or this user guide for details on the above mentioned procedures. | p.20 |
| The reader is not working. The Smart card is not reading. The magnetic swipe card is not reading correctly (no beeps or blinks). | The through hole ribbon cable may be pinched. The Smart card default of the card reader may not be correct for the Smart card. The “Mag Track in Use” default for all Magnetic Card Credential Readers is “Track2”. The magnetic swipe card data may be on Track1 or Track3. | Check that the through hole ribbon cable is not pinched. Change the Smart card format using the SUS. Select AD-200/AD-201 “Lock Properties”, “Reader” tab, and “Smart cards in use”. Use the SUS to change “Mag Track in Use”. Select AD-200/AD-201 “Lock Properties”, “Reader” tab, and “MAG Card Track selection”. Refer to the installation instructions that came with the AD-200/AD-201 lock, or the SUS user guide for details on the above mentioned procedures. | p.20 |
| Wired remote release feature is not working. | The lock may not be compatible with remote release. The hardware or firmware version may not be compatible with remote release. The lock’s inside cover may not be properly or completely installed. The remote release switch may not be functioning correctly. | Wired remote release is available only on the AD-200/AD-201 storeroom function. Wired remote release is compatible with hardware version F or higher, and with locks programmed with AD-200/ AD-201 version 2.45.1 firmware or higher. Check that the inside cover is completely and properly installed. Check that the switch closes and delivers less than 5 ohms resistance when activated. | p.20 |