The HA-58 is a heat detector meant to discover cases of fire in the first phase. If the temperature rises, the HA-58 will start emitting a loud alarm tone of at least 85dB (A). It’s advisable to test the heat detector weekly by using the test button. Attention: This heat detector only signals when the temperature rises to 55˚C or higher. It doesn’t directly detect smoke or fire. Save this manual in a secure location, like the fuse box cabinet.


INSTALLATION INFORMATION: Install the ceiling plate on a location fitting the description above using plugs and screws. Remove the plastic foil from the battery that is placed inside of the detector, plug it in the cable located inside the battery compartment and place it firmly inside the compartment. Once a battery is placed, you should be able to place the detector on the ceiling plate and rotate it easily. Test the detector first by holding the “Test”-key for 2 seconds. The RED LED will blink every minute to show the detector is still operational.


USE, TESTING AND MAINTENANCE: USE: The heat detector is operational if the 9 volt battery (6F22) is placed and the HA-58 is mounted to the ceiling. You can only place the detector on the ceiling plate if the 9 volt battery is installed. If the detector is operational the red LED will blink every minute. Once the measured temperature by the heat detector is higher than 55°C the alarm will go off. A loud beep will sound and the red LED will blink continuously. Once the heat dissipates, the alarm will stop automatically.
Testing: By pressing the test key on the HA-58, the alarm can be tested to ensure it is still operational. Hold the key for at least 2 seconds. Operation is correct if the red LED blinks and a tone is audible. Preferably check the detector weekly. During alarm state, the HA-58 will generate a tone of at least 85dB(A) sound pressure. Do not test the heat detector with candles, open flames, cigarettes or similar methods. It is possible to test the heat detector with a hair dryer.
Maintenance: The HA-58 can be cleaned with a vacuum cleaner.
REPLACING THE BATTERIES: The detector is supplied using a 9Volt blok battery. Only use the recommended type Pairdeer 6F22. Under normal con- ditions the battery will last at least one year. If it is about to need replacement, the smoke detector will make a chirping sound every 60 seconds for at least 30 days. Test the detector after every battery replacement. If the heat detector does not function, please contact your supplier
ENVIRONMENT: Do not throw away used batteries, but recycle them using your local chemical depot. Product may not be thrown out as normal waste, but must be recycled as electrical waste.
SPECIFICATIONS: Usage temperature 0˚C tot 60˚C Power 9V DC batterij Alarm point 50~60 ˚C Power usage in standby 15 µA max. Sound level during alarm 85dB op 1 meter Maximum distance from the wall 7,5m

WWW.ALECTO.NL [email protected]
Hesdo, Australiëlaan 1 5232 BB, ‘s-Hertogenbosch The Netherlands
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No sound during the test procedure Note: Hold the test button several seconds during a test. | 1. Remove the detector from the ceiling plate and check if the battery is properly connected. | p.2 | |
| No sound during the test procedure Note: Hold the test button several seconds during a test. | 2. Clean the heat detector. | p.2 | |
| The heat detector beeps every minute | Replace the 9V battery | p.2 | |
| The heat alarm regularly gives a false alarm during cooking or during use of the shower. | 1. Clean the heat detector. | p.2 | |
| The heat alarm regularly gives a false alarm during cooking or during use of the shower. | 2. Move the heat detector to another location. | p.2 |