SP2554 1.10 en-US ENGLISH


The information in this document is for informational purposes only. Please inform HMS Industrial Networks of any inaccuracies or omissions found in this document. HMS Industrial Networks disclaims any responsibility or liability for any errors that may appear in this document.
HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product development. The information in this document shall therefore not be construed as a commitment on the part of HMS Industrial Networks and is subject to change without notice. HMS Industrial Networks makes no commitment to update or keep current the information in this document.
The data, examples and illustrations found in this document are included for illustrative purposes and are only intended to help improve understanding of the functionality and handling of the product. In view of the wide range of possible applications of the product, and because of the many variables and requirements associated with any particular implementation, HMS Industrial Networks cannot assume responsibility or liability for actual use based on the data, examples or illustrations included in this document nor for any damages incurred during installation of the product. Those responsible for the use of the product must acquire sufficient knowledge in order to ensure that the product is used correctly in their specific application and that the application meets all performance and safety requirements including any applicable laws, regulations, codes and standards. Further, HMS Industrial Networks will under no circumstances assume liability or responsibility for any problems that may arise as a result from the use of undocumented features or functional side effects found outside the documented scope of the product. The effects caused by any direct or indirect use of such aspects of the product are undefined and may include e.g. compatibility issues and stability issues.



This manual describes how to install Anybus Wireless Bolt Serial and set up a basic configuration.
For additional documentation and software downloads, FAQs, troubleshooting guides and technical support, please visit www.anybus.com/support
The following conventions are used to indicate safety information and other important content in this document:
Instruction that must be followed to avoid a risk of reduced functionality and/or damage to the equipment, or to avoid a network security risk.
Additional information which may facilitate installation and/or operation.
Anybus® is a registered trademark of HMS Industrial Networks. All other trademarks mentioned in this document are the property of their respective holders.
Preface 3 (24)

This equipment is recommended for use in both industrial and domestic environments. For industrial environments it is mandatory to use the functional earth connection to comply with immunity requirements. For domestic environments the functional earth must be used if a shielded Ethernet cable is used, in order to meet emission requirements.
This equipment contains parts that can be damaged by electrostatic discharge (ESD). Use ESD prevention measures to avoid damage.
The intended use of this equipment is as a communication interface and gateway. The equipment receives and transmits data on various physical levels and connection types.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Safety 4 (24)

Make sure that you have all the necessary information about the capabilities and restrictions of your local network environment before installation.
For optimal reception, wireless devices require a zone between them clear of objects that could otherwise obstruct or reflect the signal. A minimum distance of 50 cm between the devices should also be observed to avoid interference.
The characteristics of the antenna should also be considered when choosing the placement and orientation of the unit.
See the Anybus Wireless Bolt Serial User Manual for more information.
Preparation 5 (24)

The device is intended to be mounted on top of a machine or cabinet through an M50 (50.5 mm) hole using the included sealing ring and nut.
The top mounting surface (in contact with the sealing) must be flat with a finish equivalent to Ra 3.2 or finer and cleaned and free from oils and greases.
Make sure that the sealing ring is correctly placed in the circular groove in the top part of the housing before tightening the nut.
Always hold the BOTTOM part of the unit when untightening the nut, not the top part (the cap).

All measurements are in mm.
Installation 6 (24)

The 18-pin connector is common for all models of the Anybus Wireless Bolt. Some pins may have a different function depending on model. Unused pins should not be connected.

Fig. 1 Connector
The location of the RESET button can be used as a reference for the pin numbering when the connector is attached to the Wireless Bolt Serial. Pin 1 will be the pin closest to the button.
The Ethernet interface is intended for configuration purposes only. Wireless Bolt Serial is not designed for permanent Ethernet communication.
A and B marking differs between different devices, in this product A is TX+/RX+ or D+ and B is TX-/RX- or D-.
Installation 7 (24)

Installation 8 (24)

When using Easy Config Modes, the Wireless Bolt Serial that is to be configured as a Client does not need to be connected to the Ethernet wires. Only power and serial wiring are used.
To make an Ethernet, serial and power connector cable for Anybus Wireless Bolt Serial:

To maintain signal integrity, low emission and high immunity to EMI, untwist the twisted pair cable as little as possible.
The shield and the other wires are not used.
Installation 9 (24)

The digital input can be used to control roaming between Bluetooth access points (NAP). For more information, refer to the AT Reference Guide at www.anybus.com/support
If voltage is applied to the digital input for more that 10 seconds the unit will be reset to factory defaults.

Fig. 3 RESET button
The RESET button is located on the bottom of the unit.
When the unit is powered on, press and hold RESET for >10 seconds and then release it to reset to the factory default settings.
If the web interface cannot be accessed, the unit can be reset by starting in Recovery Mode and reinstalling the firmware using Anybus Firmware Manager II, which can be downloaded from www.anybus.com/support
To enter Recovery Mode, press and hold RESET during startup.
Firmware updates should normally be carried out through the web interface. Recovery Mode should only be used if the unit is unresponsive and the web interface cannot be accessed.
Installation 10 (24)

Anybus Wireless Bolt Serial is configured via a web interface. Parameters can be set individually or using pre-configured Easy Config modes.
Advanced configuration can be carried out by issuing AT commands via the web interface or over a Telnet or RAW TCP connection to port 8080 or over serial interface. For more information, refer to the AT Reference Guide at www.anybus.com/support

The web interface is accessed by pointing a web browser to the IP address of the unit.
The default address is 192.168.0.99.
The configuration settings are described in detail in the User Manual.

Fig. 4 Web interface

In the web interface, you can perform the initial configuration using Easy Config Modes:

Fig. 5 Example, Easy Config Mode 5
Configure as Bluetooth client and scan for another client (PANU to PANU). Recommended setting for Bluetooth point-to-point communication. Listens for 40 seconds or until a configuration is established. 2 – Reset configuration to factory defaults.
Wait for automatic configuration. Listens for 120 seconds or until receiving a configuration. Configure units in mode 4 as clients. 5 WLAN AP Restart as access point and connect clients. Mode 5 and 6 will time out after 120 seconds. 6 Bluetooth NAP 11 (any) Activate ConfigLock mode.
The Easy Config Modes are also described when selected in the web interface.
EC Role Description · 1 Bluetooth PANU · 4 Client


Fig. 6 The default mode is Easy Config Mode 4
By default Wireless Bolt and Bridge starts in Easy Config Mode 4.
Configuration of Wireless Bolt and Bridge Clients can be performed wirelessly, via a PC connected to the Wireless Bolt or Bridge Access Point.
After factor reset, Wireless Bolt will by default start in Easy Config Mode 4, if there is no Ethernet connection.
The Wireless Bolt or Bridge Client does not need to be connected with an Ethernet cable during configuration.

Connect two or more Wireless Bolt Serial units via WLAN or Bluetooth using Easy Config.
When installing more than one Wireless Bolt Serial in the bridge, configure the Wireless Bolt Serial connected to the Master device as the Access Point. Configure the Wireless Bolt Serial connected to the Slave as a Clients.
When the Wireless Bolt Serial Access Point is connected to a Modbus network, the Master device must be connected to the Access Point.

Fig. 7 Serial bridge example

The default address to Access Point unit 2 is 192.168.0.99.
– Easy Config Mode 1 for Bluetooth PANU-PANU. Used for setting up point-to-point communication.
– Easy Config Mode 5 for WLAN
– Easy Config Mode 6 for Bluetooth
→ Client unit 1 starts up in Easy Config Mode 4 and is open for automatic configuration during 120 seconds.
→ Access Point unit 2 will discover and configure Client unit 1 as a Client and configure itself as an Access Point.
→ Client unit 1 will be assigned the first free IP address in the same Ethernet subnet as Access Point unit 2.
The default address to the first Client unit is 192.168.0.100.
→ If no connection is established during Easy Config Mode:
– Ensure that Client unit 1 is disconnected from Ethernet.
– Disconnect Client unit 1 from power and repeat Activate Easy Config step 5 and 6.
When using Easy Config Mode 1, continue with Serial Configuration.
When using Easy Config Mode 5 or Easy Config Mode 6, up to 6 additional Wireless Bolt Serial Clients can be added to the serial bridge.
→ Each new Client unit will be assigned the next free IP address in the current Ethernet subnet.

From the PC connected to Access Point unit 2:
Specify the physical serial communication interface. Select RS232 or RS485.
Baud rate Select a baud rate to specify the rate at which information is transferred in a communication channel. To avoid timing problems if different baud rates are set on the master and the slaves, set the lowest baud rate on the master.
Data bits Specify the number of data bits to transmit. Select 5, 6, 7 or 8 bits.
Parity Specify if parity should be used to detect errors in code. Select No parity, Odd parity or Even parity.
Stop bits Specify the number of stop bits used to indicate the end of data transmission. Select stop bit 1 or 2.
When Modbus Optimization is selected, the communication is optimized to keep all Modbus packets together in one frame. This mode should only be enabled when communicating with Modbus RTU devices.
TCP Mode Select a TCP Mode from the dropdown menu: Client: Wireless Bolt Serial acts as a client and establishes a connection to the TCP server. Server: Wireless Bolt Serial acts as a server and listens for incoming connections from the TCP client.
TCP Server IP When TCP Mode Client is enabled, enter the TCP Server IP address.
When TCP Mode Server is enabled, select Modbus Gateway Mode to enable Modbus TCP to Modbus RTU gateway functionality.
TCP Port When TCP Mode is enabled, enter a TCP Port number. Default port: 5005 When Modbus Gateway Mode is active, the port automatically changes to Modbus TCP port 502.
Operating mode · Modbus Optimization · Modbus Gateway Mode

For more information, refer to Connector, p. 7 and Cabling, p. 9.

Any one of these actions will restore the factory default settings:
IP Assignment Static IP Address 192.168.0.99 Subnet Mask 255.255.255.0 Default Gateway 192.168.0.99 Internal DHCP Server Disabled
Operating Mode Client Channel Bands 2.4 GHz & 5 GHz Authentication Mode WPA/WPA2–PSK Channel Auto Bridge Mode Layer 3 IP forward
Operating Mode PANU (Client) Local Name [generated from MAC address] Connectable No Discoverable No Security Mode Just works Bluetooth LE Disabled
Operating Mode RS232 Baud Rate 57600 bits/s Data bits 8 Stop bits 1 Parity No parity Modbus optimization Off TCP Mode Server

Default Serial Settings (continued)
Modbus Gateway Mode Disabled TCP port 5005

Technical Data 21 (24)
For complete technical specifications and regulatory compliance information please visit www.anybus.com/support
Order code AWB2010 AWB2011
Color Black White top and black base
Connector Included plug connector (2x9p; 3.5mm, Phoenix DFMC 1.5/9-ST-3.5, push-in spring connection).
Range Up to 100 meters free line of sight
Antenna One internal antenna. Dual-band 2,4GHz and 5GHz.
Operating: Shadow black and white: -40 to +65 °C Direct sunlight: Black -40 to +45 °C, White -40 to +65 °C Storage temperature: -40 to +85 °C
Housing material Top: Valox 357X(f1) PBT/PC. Suitable for outdoor use with respect to exposure to ultraviolet light, water exposure and immersion in accordance with UL 746C. Bottom: Celanex: XFR 6840 GF15. PBT glass reinforced plastic.
IP protection class IP66, IP67 and UL NEMA 4X for top (outside the host), IP21 for bottom (inside the host).
Dimensions Diameter: 68 mm. Height: 75 mm (95 mm including connector). Outside height: 41 mm.
Mounting M50 screw and nut (50.5 mm hole needed).
Power 9-30 VDC (-5% +20%), Cranking 12V (ISO 7637-2:2011 pulse 4). Reverse polarity protection. (Consumption: 0.7W idle, 1.7W max.)
Configuration Three different methods: 1. Accessing the built-in web pages in the product 2. Sending AT-commands via Telnet/Raw TCP and Serial 3. Using Easy Config modes.
Vibration compatibility Sinusodial vibration test according to IEC 60068-2-6:2007 and with extra severities; Number of axes: 3 mutually perpendicular (X:Y:Z), Duration: 10 sweep cycles in each axes,
Temperature compatibility · Weight 81 g

Technical Data 22 (24)
Order code AWB2010 AWB2011
Velocity: 1 oct/min, Mode: in operation, Frequency: 5-500 Hz, Displacement ±3.5 mm, Acceleration: 2g.
Shock test according to IEC 60068-2-27:2008 and with extra severities; Wave shape: half sine, Number of shocks: ±3 in each axes, Mode: In operation, Axes ± X,Y,Z, Acceleration: 30 g, Duration: 11 ms.
Humidity compatibility EN 600068-2-78: Damp heat, +40°C, 93% humidity for 4 days.
Wired interface Serial: RS232/485 Baud rate: 2.400 - 921.600 kbit/s, data bits 5-8, stop bits 1-2, parity None, Odd, Even. Transparent serial protocol transfer including support for Modbus-RTU. Ethernet: 10/100BASE-T with automatic MDI/MDIX auto cross- over detection. For configuration only.
Wireless LAN Wireless standards: WLAN 802.11 a, b, g, n, d, r (fast roaming). Operation modes: Access point or Client WiFi channels: 2.4 GHz, channel 1-11 + 12-13 depending on regulatory domain scan. 5 GHz Access Point: 36-48 (U-NII-1), 5 GHz Client: 100-116 + 132-140 and 120-128 depending on regulatory domain scan. (U-NII-1, U-NII-2, U-NII-2e). RF output power: 13.75 dBm Max number of slaves for access point: 7 Power consumption: 54mA@24VDC Net data throughput: 20 Mbps. Link speed: max 65 Mbps (802.11n SISO) Security: WEP 64/128, WPA, WPA-PSK and WPA2, TKIP and AES/ CCMP, LEAP, PEAP including MS-CHAP.
Classic Bluetooth Wireless standards (profiles): PANU & NAP Operation modes: Access point or Client RF output power: 9.75 dBm Max number of slaves for access point: 7 Power consumption: 36 mA@24VDC Net data throughput: ~1 Mbps Bluetooth version support: Classic Bluetooth v2.1 Security: Authentication & Authorization, Encryption & Data Protection, Privacy & Confidentiality, NIST Compliant, FIPS Approved


© 2020 HMS Industrial Networks Box 4126 300 04 Halmstad, Sweden
[email protected] SP2554 1.10 en-US / 2020-06-11 / 18913