For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301
or visit our website at www.whirlpool.com
In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca
30" (76,2 CM) Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service, composer
le 1-800-807-6777 ou visiter notre site Web à
Table of Contents/Table des matières 2

FOR RESIDENTIAL USE ONLY. IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.


Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed

7" (17.8 cm) round metal vent system with wall or roof cap

For 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vented installations
Drill with ¹⁄₈" (3 mm), ¹⁄₂" (13 mm) and 1¹⁄₄" (3 cm) bits
3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular metal vent system with wall or roof cap
Recirculating kit (Charcoal filter)" Part Number W11371717
Power cord kit Part Number W10355452*
Stainless steel cleaner and polish Part Number 31462A*
*For information on ordering, see the “Assistance or Service” section.
Parts supplied Remove parts from package. Check that all parts are included.
Location Requirements IMPORTANT: Observe all governing codes and ordinances.

It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the left wall.
Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. Consult the cooktop/range manufacturer installation instructions before making any cutouts.
This range hood is recommended for use with cooktops with a maximum total rating of 40,000 Btus or less.
Grounded electrical outlet is required. See “Electrical Requirements” section.
UL Listed/CSA Approved wire connectors
All openings in ceiling and wall where range hood will be installed must be sealed.
These range hoods are factory set for vented installations. Models that are capable of being installed as non-vented (recirculating) require charcoal filters. See the “Assistance or Service” section for information on ordering charcoal filters.
For Mobile Home Installations The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.
Duct tape · Optional accessories

Product Dimensions
Venting System
69/16" (16.7 cm)

Flexible vent is not recommended. Flexible vent creates both back pressure and air turbulence that greatly reduce performance.
The vent system is optional for this model.
Vent system can terminate either through the roof or wall. Use 7" (17.8 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.
Top Venting Wall Venting

A. 7" (17.8 cm) round vent
A. 7" (17.8 cm) round vent out
through roof (purchased separately).
the top and through the wall (purchased separately).
B. Roof cap with damper
B. Wall cap with damper
Cold Weather Installations An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house.
Vent system must terminate to the outdoors, except for non- vented (recirculating) installations.
A. 24” (61.0 cm) minimum distance from electric cooking surface.
Do not terminate the vent system in an attic or other enclosed area.
24" (61.0 cm) minimum distance from gas cooking surface. 30" (76.2 cm) suggested maximum above the cooking surface. B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop. C. 30" (76.2 cm) minimum cabinet opening width for 30" (76.2 cm)
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use 7" (17.8 cm) round metal vent. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.
models and 36" (91.4 cm) minimum cabinet width for 36" (91.4 cm) models. D. 12" (30.5 cm) cabinet depth.
E. 36" (91.4 cm) base cabinet height.
The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.
(purchased separately) · (purchased separately)

For the most efficient and quiet operation:
Electrical Requirements Observe all governing codes and ordinances. Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. A copy of the above code standards can be obtained from:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps or duct tape to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around the cap.
Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
National Fire Protection Association
1 Batterymarch Park Quincy, MA 02169-7471
CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
45° elbow 2.5 ft (0.8 m)
If the house has aluminum wiring, follow the procedure below:
90° elbow 5 ft (1.5 m)
7" (17.8 cm) wall cap 0 ft (0 m)
Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.
Wall cap 90˚ elbow
6 ft (1.8 m)
2 ft (0.6 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
System length = 13 ft (3.9 m)
7" (17.8 cm) Round Vent = 50 ft (15.2 m)
Vent Piece · Maximum Recommended Length

Depending on your model, determine which venting method to use: roof, wall or non-vented (recirculating).
Using a #2 Phillips screwdriver, install the drywall anchors.
Using #8-18 x 1" (4.2 x 25 mm) flat-head #2 Phillips screws, install the mounting brackets using the upper holes.
It is recommended that the vent system be installed before the range hood is installed. Go to “Venting System” in the “Installation Requirements” section if you need assistance.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for the vent system. 1. Disconnect power


Failure to do so can result in death or electrical shock.
Remove the two filter security screws and put them aside.
Press the filter latch to release the grease filters.


Align the exterior edge of the mounting brackets with the exterior edges of the upper cabinet. IMPORTANT: The brackets should touch the upper cabinet. With a pencil, mark the upper holes on the brackets.

Set the range hood on its back on a covered surface.
Using a #2 Phillips screwdriver, remove the rectangular damper attached with 3.5 x 9.5 mm screws.
Using a #2 Phillips screwdriver, remove the electrical box cover.
Using a flat-blade screwdriver, remove the appropriate power supply knockout.

7. Mark and Cut Vent Opening


Using the 7" (17.8 cm) round vent mounting plate, draw the vent opening outline on the underside of the cabinet:
Lift the range hood into place and insert the mounting bracket tabs through the slots in the back of the range hood.
- Place the vent mounting plate on the bottom of the cabinet. Position the edge of the plate with the widest distance (A) between the hole and edge of the mounting plate against the wall. Position the side edges of the mounting plate between the dots marked previously. IMPORTANT: The widest edge (A) of the vent mounting plate must be positioned against the wall. - Trace the 7" (17.8 cm) vent opening (solid line) on the cabinet bottom. Using a jigsaw or keyhole saw, cut the vent opening 1" (2.5 cm) larger than the 7" (17.8 cm) hole traced (dashed line).

Hold the range hood firmly in place with one hand and bend each mounting tab (A) upward approximately 90°. Mark the hole at the power supply knockout (B).
OPTIONAL: Mark the hole in each mounting tab. Remove the range hood and set it aside.

10. Attach Vent Damper or Transition


Using a 1 " (3 cm) drill bit, drill the hole in the dot marked previously at the electrical strain relief. OPTIONAL: Using a " (3 mm) drill bit, drill pilot holes for the dots marked previously at each mounting tab at an approximate 45° angle in an upward direction.
Using (2) short Phillips head screws, install the 7" (17.8 cm) round vent mounting plate over the vent knockouts removed in Step 8. Position the wide flange (C) to the front.

If installing the optional round damper, position it over the round vent mounting plate.
Install a UL Listed/CSA Approved " (13 mm) strain relief (A).
Start a #8-18 x " (4.2 x 16 mm) truss-head screw into the mounting tab (F) on each side of the range hood as shown in the inset. Insert the screws approximately 2 turns into the mounting tab holes.
Using a #2 Phillips screwdriver remove the 2 screws and remove the top, front rectangular vent cover (E). Go to Step 12.
7" (17.8 cm) Round Vent Installations
Remove both top knockouts (C and D).
Non-vent (Recirculating) Installations

Use a UL Listed/CSA Approved wire connector and connect the 2 white wires (A) together.

Use a UL Listed/CSA Approved wire connector and connect the 2 black wires (B) together.

Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death, fire, or electrical shock.
Lift the range hood into place, positioning the rear slots over the mounting brackets.
Connect the green (or bare) ground wire (C) from the power supply to the green ground screw in the electrical box and tighten the screw securely.
Using a Phillips screwdriver, push on the screws that are started into the top mounting tabs and bend the tabs against the cabinet side walls. Attach the screws to the cabinet side walls.
Reinstall the electrical box cover.
Reconnect power.
For direct wire installations, run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances. There must be enough wiring from the fused disconnect (or circuit breaker) box to make the connection in the range hood electrical terminal box.
Option 2 - Power Cord Kit Installations For optional power cord kit installations, follow the instructions supplied with the power cord kit. See the “Assistance or Service” section for information on ordering. NOTE: Use only with range hood cord connection kits that have been investigated and found acceptable for use with this model range hood. 14. Complete the Installation
Tighten the strain relief screws.
OPTIONAL: If you prefer, bend the rear tabs against the rear of the range hood and attach to the wall using #8-18 x
Install a 120V, 75W maximum, incandescent light bulb with E26 base. See “Replacing the Incandescent Light Bulb” in the “Range Hood Care” section.
If removed previously, replace the filter. See “Grease or Charcoal Filter” in the “Range Hood Care” section.
Connect the ventwork to the range hood. Seal joints with vent clamps or duct tape to make secure and airtight.
For vented installations: Install a metal filter.
For non-vented (recirculating) installations: Install a charcoal filter.
Check the operation of the range hood fan and light. See the “Range Hood Use” section.

If the range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown. Disconnect the power and check the wiring connections.
"

The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen. The hood controls are located on the front panel of the range hood.

A. On/Off light switch B. Fan speed switch
Operating the light Press the light switch to the left to turn the light On. Press the light switch to the right to turn the light Off.
Operating the fan The fan has 2 speeds. Press the fan switch to the left for Low speed. Press the fan switch to the right for High speed. Return the fan switch to the center to turn the fan Off.
A. LED light housing and cover B. Grease filter retainer C. Grease filter
Cleaning IMPORTANT: Clean the hood and grease filters frequently according to the following instructions. Replace the grease filter before operating hood.
Grease or Charcoal Filter To Clean the Filter: 1. Remove the screw from the grease filter retainer. 2. Push the grease filter retainer to release the filter.
Exterior Surfaces: IMPORTANT: Do not use soap-filled scouring pads, abrasive cleaners, cooktop polishing creme, steel wool, gritty washcloths or paper towels. To avoid damage to the stainless steel, do not use cleaners that contain chlorine. Cleaning Method:

Liquid detergent or all-purpose cleaner: Rinse with clean water and dry with a soft, lint-free cloth.
Glass cleaner to remove fingerprints.
A. Filter retainer screws B. Grease filters C. Filter retainer
For stainless steel models, use Stainless Steel Cleaner and Polish: See the “Assistance or Service” section to order.
For stainless steel models, rub in the direction of the grain to avoid scratching or damaging the surface.
using warm water, dishwashing liquid, and a non abrasive brush. For non-vented (recirculating) installations: The charcoal filter is not washable. For information on ordering, see the “Assistance or Service” section. NOTE To reduce the risk of fire or shock when the hood is used in recirculation mode, use only the conversion kit models listed below: Recirculating kit: W11371717
To Replace the Filter: 1. To reinstall the filter, place the back edge of the filter into the channel at the rear of the hood. Push the filter into place and turn the filter retainer to secure the filter to the range hood. 2. Replace the screw in the grease filter retainer.
Off · High · Off On Low

Replacing the LED Light Bulb Turn off the range hood and allow the light bulb to cool. 1. Disconnect power. 2. Remove the grease filters from the hood. 3. Remove the fused light bulb from behind the lamp spacer.

SEL0157858A
Motor Switch Low - Off - High

Light Switch · Off - On

If you need service When calling, please know the purchase date and the complete model and serial number of your appliance. This information will help us to better respond to your request.
For further assistance If you need further assistance, you can write to Whirlpool with any questions or concerns at:
Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor, MI 49022-2692
If you need replacement parts If you need to order replacement parts, we recommend that you use only FSP® replacement parts. FSP® replacement parts will fit right and work right because they are made with the same precision used to build every new Whirlpool® appliance.
Please include a daytime phone number in your correspondence.
In Canada Call the Whirlpool Canada LP Customer eXperience Centre toll free: 1-800-807-6777 or visit our webpage www.whirlpool.ca. Our consultants provide assistance with:
To locate FSP® replacement parts in your area, call us or your nearest Whirlpool designated service center.
Scheduling of service. Whirlpool designated service technicians are trained to fulfill the product warranty and provide after-warranty service, anywhere in Canada.
In the U.S.A. Call the Whirlpool Customer eXperience Center toll free: 1-800-253-1301 or visit our website at www.whirlpool.com Our consultants provide assistance with:
Features and specifications on our full line of appliances.
Referrals to local Whirlpool appliance dealers.
Scheduling of service. Whirlpool appliances designated service technicians are trained to fulfill the product warranty and provide after-warranty service, anywhere in the United States.
Use and maintenance procedures.
Accessory and repair parts sales.
Features and specifications on our full line of appliances.
For further assistance If you need further assistance, you can write to Whirlpool with any questions or concerns at:
Referrals to local Whirlpool appliance dealers.
Installation information.
Customer eXperience Centre Whirlpool Canada LP 200 - 6750 Century Ave. Mississauga, Ontario L5N 0B7 Please include a daytime phone number in your correspondence.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.).
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.