Virus Sample Stabilizer Instruction for Use (Version 1.1)

PRODUCT NAME

4. Storage

The collected specimen should be used for detection as soon as possible.

Otherwise, please store the specimen as follows. Store at 15 ~ 25°C for no

CATALOG NUMBER & SIZE

more than 24 hours. Store at 2 ~ 8°C for no more than 72 hours.If collected

specimen needs to be stored for more than 3 days, it is recommended to store

CATALOGSIZE R513-0150 sets, 1.5 mL / tube R513-0250 sets, 3 mL / tube

it at -30 ~ -15°C; If there is no low-temperature freezing condition and the

storage time is less than 7 days, it can be stored at 2 ~ 8°C.

5. Inactivation Treatment

INTENDED USE This product is applicable to specimen collection from human nasopharyngeal swab specimen and the preservation of viral nucleic acid.

Further inactivation treatment should be taken as required before extraction.

For heat inactivation of SARS-CoV-2, it is recommended to incubate at 56°C

for 30 min, and balance at room temperature for 10 min for avoiding aerosols.

6. Extraction

WORKING PRINCIPLE The sample stabilizer contains guanidine isothiocyanate and other protein denaturation reagents which can rapidly lyse cells and denature viral proteins to obtain the inactivated virus and release the nucleic acids of virus. The high concentration of guanidine salt in a suitable buffer solution can inhibit the nuclease activity and effectively protect the integrity of nucleic acids. The nuclease-free tube is treated with nuclease eliminator further ensuring the integrity of nucleic acid.

6.1 After inactivation treatment of specimen, gently stir and squeeze the swab,

then remove the swab. And gently pipette to mix the sample stabilizer

thoroughly.

6.2 Perform the extraction procedure by different extraction products:

6.2.1 Vazyme FastPure Viral DNA/RNA Mini Kit (Column based, #RC312):

For the detailed protocol, please refer to the manual of #RC312.

1. Aliquot 200 μl of absolute ethanol to a new 1.5 mL of nuclease-free EP tube

(additional consumable).

COMPONENTS

2. Add 500 μl of the above sample stabilizer to the tube containing absolute

Virus sample stabilizer consists of Tris buffer, guanidine isothiocyanate,

ethanol, then mix thoroughly by inverting the tube.

3. Place the adsorption column in a 2 mL of collection tube and transfer the

surfactant and nuclease-free water.

mixture to the adsorption column, cover the tube cap then centrifuge at

STORAGE & SHELF LIFE

× g for 1 min.

Store at 15 ~ 25°C for 12 months.

4. Discard the filtrate and reuse the collection tube. Add 600 μl of Washing

Buffer to the adsorption column, and centrifuged at 12,000 × g for 30 sec,

SAMPLING REQUIREMENTS

discard the filtrate.

1. This product is suitable for the preservation of human nasopharyngeal swabs.
5. Repeat Step 4 once.
2. For liquid specimens such as sputum, bronchial lavage and alveolar lavage
6. Place the adsorption column in a 2 mL of collection tube (reused), centrifuge

fluids, it is recommended to use a wide-mouth tube (e.g. a 50 mL centrifuge

empty adsorption column at 12,000 × g for 2 min.

tube) for collection; If using this product for specimen collection, it is important

7. Transfer the adsorption column to a new 1.5 mL centrifuge tube (provided in

to avoid the contamination of the outer wall of the tube. Therefore, the volume

the kit), add 50 μl of Elution Buffer, incubate at room temperature for 1 min,

of sample added in R513-01 should be less than 1 mL, the volume of sample

centrifuge at 12,000 × g for 1 min.

added in R513-02 should be less than 2 mL.

8. Discard the adsorption column, the eluted DNA/RNA can be used directly in

downstream experiments or stored at -20°C for short-term storage, or stored at

-70°C for long-term storage.

PROTOCOL

6.2.2 Vazyme Virus DNA/RNA Extraction Kit (Magnetic Bead based, #RM102):

1. Collecting Specimen

For the detailed protocol, please refer to the manual of #RM102.

For the detailed methods of specimen collection, please refer to the protocol in

1. Aliquot 20 μl of Proteinase K to a new 1.5 mL of nuclease-free EP tube

the "Microbiology Specimen Collection Manual" and "Nursing Clinical Practice

(additional consumable).

Guidelines".

2. Add 200 μl of the above sample stabilizer and 700 μl of lysis solution ( Make

For throat swab specimen, insert swab into the deep part of pharyngeal

sure absolute ethanol has been added) to the tube containing Proteinase K,

isthmus (both sides of uvula and tonsil), and rotate the swab several times

then mix thoroughly by vortexing gently or inverting the tube.

against the wall of pharyngeal isthmus.

3. Then add 20 μl of magnetic beads to above mixture, vortex and mix for 15

For nasal swab specimen, insert swab into the deep part of the nasal cavity,

sec.

and rotate the swab several times against the wall of nasal cavity.

4. Incubate the above mixture at room temperature for 5 min; and invert the
2. Usage

tube twice during this period.

Immerse the swab head in the sample stabilizer in the tube, carefully break

5. After brief centrifugation, place the samples on a magnetic stand. Wait until

and discard the swab shaft; then tighten the tube cap and put it into a

the solution clarifies (about 1 min). Keep on magnetic stand, and carefully

disposable zip-lock bag. Confirm that the information of the storage tube and

discard the supernatant without disturbing the beads.

the zip-lock bag are consistent.

6. Then operate the remaining steps according to the manual of the extraction

kit. Add 700 μl of Washing Buffer 1 and 700 μl of Washing Buffer 2 respectively

The disposable zip-lock bag is used to seal the sample after collection, which

to rinse the beads. Then use the Elution Buffer to collect the nucleic acid into a

is convenient for transportation and disinfection operation before sample

new 1.5 mL of nuclease-free EP tube.

processing.

3. Transportation

6.2.3 Use extraction products of other supplier:

Keep the tube cap facing up and place the tube in an upright vertical position

Treat the sample stabilizer as a specimen and operate the procedure accord-

in the sample collection container for transportation. Make sure that the swab

ing to the corresponding manual.

head is not exposed and is immersed thoroughly in the sample stabilizer.

Virus Sample Stabilizer · 12,000

Page 2 of the Vazyme Virus Sample Stabilizer user manual — REFERENCE
Page 2 · click to enlarge
Page 2

[Address] Floor 1-3, Building C2, Red Maple Park of Technological Industry,

Kechuang Road, Economy&Technology Development Zone, Nanjing, China

Nanjing Vazyme Medical Technology Co.,Ltd.

[Tel] +86 25 8436 5701 [Website] www.vazyme.com

PRODUCT PERFORMANCE INDICATOR

1. The package is intact; the appearance is neat, without leakage; and the sign

is clear.

2. PH value should be 7.0-7.2.
3. The sample stabilizer is a colorless and transparent liquid with a volume of

about 1.5 mL (R513-01) or 3 mL(R513-02).

1. It should be operated by professionally trained inspectors, read the product

manual carefully before operation. Protective measures against infectious

diseases should be took. Thorough sterilization must be done after operation

of handling reagents and specimens.

2. Even though this reagent can inactivate the virus, please treat the sample as

the inactivated specimen and perform the treatment process carefully.

3. This product is a disposable product.
4. The involved specimen is considered as infectious substances, the operation

and disposal must be complied with the relevant requirements of "the General

Guidelines for Biosafety of Microbial Biomedical Laboratories” and "Medical

Waste Regulations Guide".

5. The sample stabilizer contains guanidine salts of protein denaturant, which

is corrosive. Please operate carefully. If it splashes onto the skin, please wash

immediately with plenty of water.

6. Sample stabilizer contains high concentration of guanidine salt, which can

form precipitates or froze up when stored at 2~8°C or < 0°C. This is a normal

phenomenon and does not affect the performance of the sample stabilizer. In

this case the sample stabilizer should be redissolved before use.

REFERENCE

1. Chevillard S. 1993. A method for sequential extraction of RNA and DNA from

the sample, specially designed for a limited supply of biological material.Bio-

techniques. 15:22–24.

CONTACT Manufacturer: Nanjing Vazyme Medical Technology Co., Ltd. Address: Floor 1-3, Building C2, Red Maple Park of Technological Industry, Kechuang Road, Economy&Technology Development Zone, Nanjing, China Tel: +86 25 8436 5701 Customer Service Provider: Nanjing Vazyme Medical Technology Co., Ltd. Address: Floor 1-3, Building C2, Red Maple Park of Technological Industry, Kechuang Road, Economy&Technology Development Zone, Nanjing, China Tel: +86 25 8436 5701

DATE OF APPROVAL AND MODIFICATIONOF INSTRUCTION April 4th, 2020

DATE OF MANUFACTURE AND EXPIRATION See packaging

Vazyme Virus Sample Stabilizer — REFERENCE diagram (page 2)
Fig. 1
M Eanufacturer xpire Date Consult instructions for use

Floor 1-3, Building C2, Red Maple Park of Technological

Development Zone, Nanjing, China

92-516 Lodz, Puszkina Str. 80, Poland

www.vazyme.com

Symbols

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Vazyme Virus Sample Stabilizer

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Vazyme Virus Sample Stabilizer

Be the first to ask — other owners or our team will answer.

Original document

Vazyme Virus Sample Stabilizer manual PDF

2 pages·145 KB·Medical·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…