SP2727 1.11 en-US ENGLISH


The information in this document is for informational purposes only. Please inform HMS Networks of any inaccuracies or omissions found in this document. HMS Networks disclaims any responsibility or liability for any errors that may appear in this document.
HMS Networks reserves the right to modify its products in line with its policy of continuous product development. The information in this document shall therefore not be construed as a commitment on the part of HMS Networks and is subject to change without notice. HMS Networks makes no commitment to update or keep current the information in this document.
The data, examples and illustrations found in this document are included for illustrative purposes and are only intended to help improve understanding of the functionality and handling of the product. In view of the wide range of possible applications of the product, and because of the many variables and requirements associated with any particular implementation, HMS Networks cannot assume responsibility or liability for actual use based on the data, examples or illustrations included in this document nor for any damages incurred during installation of the product. Those responsible for the use of the product must acquire sufficient knowledge in order to ensure that the product is used correctly in their specific application and that the application meets all performance and safety requirements including any applicable laws, regulations, codes and standards. Further, HMS Networks will under no circumstances assume liability or responsibility for any problems that may arise as a result from the use of undocumented features or functional side effects found outside the documented scope of the product. The effects caused by any direct or indirect use of such aspects of the product are undefined and may include e.g. compatibility issues and stability issues.

This manual describes how to install and configure Anybus Wireless Bolt IoT.
For additional documentation and software downloads, FAQs, troubleshooting guides and technical support, please visit www.anybus.com/support
Preface 3 (22)

Numbered lists indicate tasks that should be carried out in sequence:
Bulleted lists are used for:
→ and a result
User interaction elements (buttons etc.) are indicated with bold text.
Program code and script examples
Instruction that must be followed to avoid a risk of reduced functionality and/or damage to the equipment, or to avoid a network security risk.
Additional information which may facilitate installation and/or operation.
Anybus® is a registered trademark and Wireless Bolt IoT™is a trademark of HMS Industrial Networks AB. All other trademarks mentioned in this document are the property of their respective holders.
Preface 4 (22) · ► An action

This equipment is recommended for use in both industrial and domestic environments. For industrial environments it is mandatory to use the functional earth connection to comply with immunity requirements. For domestic environments the functional earth must be used if a shielded Ethernet cable is used, in order to meet emission requirements.
This equipment contains parts that can be damaged by electrostatic discharge (ESD). Use ESD prevention measures to avoid damage.
The intended use of this equipment is as a communication interface and router. The equipment receives and transmits data over Ethernet and Cellular standard networks.
Safety 5 (22)

Supported SIM card types are Nano SIM for IoT and M2M, for data communication, as well as standard mobile phone Nano SIM.

To connect Wireless Bolt IoT to a cellular data network, install a cellular SIM card:
Ensure that the SIM card contact surface is facing towards the Ethernet port.

Make sure that the sealing ring is correctly placed in the circular groove in the top part of the housing before tightening the nut.
Always hold the BOTTOM part of the unit when untightening the nut, not the top part (the cap).


Fig. 2 Installation drawing
All measurements are in mm.

Connecting the Wireless Bolt IoT to PoE and DC power simultaneously may result in a current loop that could damage both the power sources and the Wireless Bolt IoT. Ensure to use only one of the power connections at a time.
Shielded or unshielded Ethernet cables may be used.
Wireless Bolt IoT is designed to comply with PoE class 0 (37-57 VDC, max 0.35 A), according to IEEE 802.3.


Ethernet Connector, RJ45 PoE

Connecting power with reverse polarity or using the wrong type of power supply may damage the equipment. Make sure that the power supply is connected correctly and of the recommended type.
When Wireless Bolt IoT is powered via the power connector, Functional Earth (FE) must be connected.
When Wireless Bolt IoT is installed in an environment with a high level of electrical noise, use a power/Functional Earth (FE) cable with a maximum length of 3 meters.
See also Technical Data, p. 18 regarding power supply requirements.


When Wireless Bolt IoT is mounted on a sheet metal plate, connect Functional Earth (FE) to the plate near Wireless Bolt IoT.


Power connector, 3-pin terminal block

3 Functional Earth (FE)
► Connect the Wireless Bolt IoT to Ethernet.

Pin Function · 1 +

Connecting the Wireless Bolt IoT to PoE and DC power simultaneously may result in a current loop that could damage both the power sources and the Wireless Bolt IoT. Ensure to use only one of the power connections at a time.



Fig. 8 Example, Wireless Bolt IoT built-in web interface
The Wireless Bolt IoT built-in web interface is used to configure the Wireless Bolt IoT system settings.
The System Overview page shows the current settings and network connection status.
The Wireless Bolt IoT comes with a default username and password.
The default username is admin. Written in lowercase letters.
You find the default password on the Wireless Bolt IoT product housing.
Wireless Bolt IoT default IP address is 192.168.0.98.
To access the Wireless Bolt IoT built-in web interface, ensure that the Wireless Bolt IoT IP address and your PC IP address are within the same IP address range.
Configuration 14 (22)


Connecting Wireless Bolt IoT to internet:
Ensure that the SIM card contact surface is facing towards the Ethernet port.
→ Wireless Bolt IoT automatically reboots for the settings to take effect.
Configuration 15 (22)

Wireless Bolt IoT should now be connected to internet.
Depending on the mobile network operator and network type, it can take up to 10 minutes the first time Wireless Bolt IoT is connecting to internet.
Verify that Wireless Bolt IoT is connected to internet, by sending a ping to Google Public DNS.
→ The ping request is sent.
→ When the ping response returns, a message appears.

Fig. 10 Example, Ping response message from target 8.8.8.8
Configuration 16 (22)


Connecting a device to internet:
Configuration 17 (22)

Technical Data 18 (22)
Order code AWB1000 AWB1001
Color Black White top and black base
Host interface RJ45 Ethernet 10/100 Mbit/s, PoE
Storage temperature -40 to +85 °C
Humidity compability EN 600068-2-78: Damp heat, +40 °C, 90% (non- condensing).
Vibration Refer to datasheet at www.anybus.com/support
Dimensions Diameter: 68 mm. Height: 75 mm without Power connector, 84 mm incl. Power connector. Height above mounting surface: 41 mm.
Housing material Plastic (see datasheet for details)
Protection class Top (outside of host): IP66 and IP67 / UL NEMA 4X Base (inside of host): IP21
Mounting M50 screw and nut (50.5 mm hole needed)
Power 3-pin screw connector and PoE (Power over Ethernet) 11-33 VDC through Power connector, PoE PD according to IEEE 802.3af through Eternet connector. Redundant or separate operation of PoE and DC connectors.
Power Consumption: Sleep Mode: Power connector 0.1 W. PoE 0.3 W Idle Mode: Power connector 0.6 W. PoE 0.8 W Worst Case (GPRS/2G) average power: Power connector 3.2 W. PoE 3.6 W. Worst case (GPRS/2G) peak current: 1.2A@11VDC
Cellular standards 4G LTE: Category Cat-M1 and NB-IoT.
Weight 95 g

Technical Data 19 (22)
Order code AWB1000 AWB1001
Frequency Bands: B1, B2, B3, B4, B5, B8, B12, B13, B17, B18, B19, B20, B26, B28 2G: EDGE, GPRS bands 850, 900, 1800, 1900
Maximum Data speeds Cat-M1: Download 300 kbps, Upload 375 kbps NB-IoT: Download 27 kbps, Upload 65 kbps GPRS/EDGE Download: 200 kbps, Upload: 200 kbps.
Ethernet protocols Transparent transfer of any TCP/UDP based protocol, Built-in firewall, NAT and DHCP server.
Certifications Refer to datasheet at www.anybus.com/support


Fig. 12 RJ45 LED indicators
LED A – LINK/ACTIVITY Function
Off No Ethernet link Yellow 10 Mb/s Ethernet link established Yellow, flashing 10 Mb/s Ethernet activity Green 100 Mb/s Ethernet link established Green, flashing 100 Mb/s Ethernet activity
LED B – STATUS Function Off No power
Blue Connected on LTE-M Purple Connected on LTE NB1
Blue, slow blink Connected on GSM.
Alternating blue/purple Trying to connect
Red, slow blink No configured cellular interface/no SIM card/no valid configuration Red Recoverable/unrecoverable fault Yellow Booting or sleep

© 2020 HMS Industrial Networks Box 4126 300 04 Halmstad, Sweden
[email protected] SP2727 1.11 en-US / 2020-12-18 / 21155
last page
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.