1. I ntroduction

The PDU is an Internet ready device designed and is equipped with an intelligent current- meter (True RMS) that will indicate the total power consumption of a power strip.

The PDU offers an easy set up and user-friendly communication software. This software provides the function that assistant manager to remotely monitor the multiple PDU power consumption to realize the total current power consumption and utilization for the enterprises.

Features:

z Built-in web server, manager can real time to monitoring the current consumption of

the power strip.

z Build-in true RMS current meter.

z Setup easily, meter can read the IP address directly.

z Homepage support SSL.

z Provide audible alarm when the power consumption over the threshold of warning and

overload.

z Send the email and traps when the power consumption exceed the trigger value of

z Provide utility, it can monitor a large mount of PDU at the same time.

z Support the SNMP and provide MIB for the PDU to be monitored by NMS.

z Provide per outlet power protection by the circuit breaker.

z Real time to control outlets of PDU.

z Indicate outlets status with LED.

z Support power on sequence.

z Option accessory can support temperature and humidity detection.

Page 4 of the PDU PDU Power Distribution Unit user manual — 2. PDU Package
Page 4 · click to enlarge
Page 4

2. PDU Package

The standard PDU package contains a Power Distribution Unit with supporting hardware and software. The components of the package are:

z Power Distribution Unit.

z Rack mount Brackets.

z CD-ROM, it contains:

z User Manual.

z PDU Software.

z MIBManagement Information Base for Network. (PDUMIB.mib)

z Adobe Acrobat Reader.

Page 5 of the PDU PDU Power Distribution Unit user manual — I nterface
Page 5 · click to enlarge
Page 5

3. Function

I nterface

PDU PDU Power Distribution Unit — I nterface diagram (page 5)
Fig. 1 · I nterface

Ethernet RJ45 port for network communication port.

Audible Alarm Warning- 1 beep in 1 second.

Overload- 3 beeps in 1 second.

Function Button z Press and release to turn off the warning beeping. The

overload beeping can not be cancelled.

z Press and hold the key after 2 beeping; it can let the meter

to show up the IP address

z Press and hold the key after 4 beeping; it can change the

way to get IP by DHCP or fixed IP.

z Press and hold the key after 6 beeping; it can reset PDU

back to default setting.

Meter 3 digits to display current and IP Address.

ID The identification of power bank or PDU.

LED Indicator SSL (yellow): Light on means web access is protected by SSL.

DHCP (Green): Light on means PDU gets IP address by DHCP.

PDU (Green): Indicate each output power status.

Status (Red)Indicate each circuit status. (by model)

Single current bank · Functions Description

Page 6 of the PDU PDU Power Distribution Unit user manual — 3. Function
Page 6 · click to enlarge
Page 6

ENV RJ11 for ENV probe attached.

Circuit Breaker Overload power protection.

Page 7 of the PDU PDU Power Distribution Unit user manual — Diagram
Page 7 · click to enlarge
Page 7

4. I nstallation

This section will provide a quick instruction to install the PDU.

Rack Mount I nstructions

A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer.

B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips)."

Diagram

PDU PDU Power Distribution Unit — Diagram diagram (page 7)
Fig. 2 · Diagram
Page 8 of the PDU PDU Power Distribution Unit user manual — Hardw are
Page 8 · click to enlarge
Page 8

Hardw are

1. Install mounting brackets.
2. The PDU comes with brackets for mounting in a rack. To mount the PDU into a rack performs the following procedure:
3. Attach the mounting brackets to the unit, using the four retaining screws provided for each of the brackets.
4. Choose a location for the brackets.
5. Align the mounting holes of brackets with the notched hole on the vertical rail and attach with the retaining screws.
6. Connect input and output power.
7. Connect Ethernet cable to the PDU.
8. Switch on the PDU.

The default setting for the way to get IP address is DHCP. If PDU can not get the IP from DHCP server, the IP address will stay at 192.168.0.216

TO SETUP THE NETWORK SYSTEM FOR PDU, STRONGLY RECOMMAND TO BUILD UP THE POWER MONITORING NETWORK SYSTEM ISOLATED WITH THE OTHERS, IN ORDER TO KEEP THE STABILITY OF GETTING POWER INFORMATION AND SYSTEM OPERATION.

Page 9 of the PDU PDU Power Distribution Unit user manual — Login:
Page 9 · click to enlarge
Page 9

5. Web I nterface

Login:

Input the PDU IP address in web browser.

Default ID is snmp.

Password is 1234.

PDU PDU Power Distribution Unit — Login: diagram (page 9)
Fig. 3 · Login:
Page 10 of the PDU PDU Power Distribution Unit user manual — I nform ation: PDU
Page 10 · click to enlarge
Page 10

I nform ation: PDU

Display total PDU and each outlet power consumption.

When plug the option device - ENV probe, it will display temperature and humidity information.

PDU PDU Power Distribution Unit — I nform ation: PDU diagram (page 10)
Fig. 4 · I nform ation: PDU
Page 11 of the PDU PDU Power Distribution Unit user manual — I nform ation: System
Page 11 · click to enlarge
Page 11

I nform ation: System

Indicate PDU system information, including:

Model No.

PDU PDU Power Distribution Unit — I nform ation: System diagram (page 11)
Fig. 5 · I nform ation: System
Show 5 more labels / short text on this page
Firmware Version · MAC Address · System Name · System Contact · Location
Page 12 of the PDU PDU Power Distribution Unit user manual — Control: Outlet
Page 12 · click to enlarge
Page 12

Control: Outlet

Indicate PDU outlet on/ off status and control outlet.

Select the outlet by checking the box and then click ON or OFF button to control output power for PDU

Monitored PDU series does not support this function.

ON: Press the icon to turn on the assigned outlets.

OFF: Press the icon to turn off the assigned outlets.

OFF/ ON: Press the icon to reboot the assigned outlets.

PDU PDU Power Distribution Unit — Control: Outlet diagram (page 12)
Fig. 6 · Control: Outlet
Page 13 of the PDU PDU Power Distribution Unit user manual — Configuration: PDU
Page 13 · click to enlarge
Page 13

Configuration: PDU

Set the outlet name and delay time.

Nam e: Rename the outlet.

ON: Set delay time for power on sequential.

OFF: Set delay time for power off sequential.

PDU PDU Power Distribution Unit — Configuration: PDU diagram (page 13)
Fig. 7 · Configuration: PDU
Page 14 of the PDU PDU Power Distribution Unit user manual — Configuration: Threshold
Page 14 · click to enlarge
Page 14

Configuration: Threshold

Set the warning and overload threshold for each circuit.

Set lower and upper threshold for temperature and humidity.

PDU PDU Power Distribution Unit — Configuration: Threshold diagram (page 14)
Fig. 8 · Configuration: Threshold
Page 15 of the PDU PDU Power Distribution Unit user manual — Configuration: User
Page 15 · click to enlarge
Page 15

Configuration: User

Change ID and password.

Default ID is snmp and password is 1234.

PDU PDU Power Distribution Unit — Configuration: User diagram (page 15)
Fig. 9 · Configuration: User
Page 16 of the PDU PDU Power Distribution Unit user manual — Configuration: Netw ork
Page 16 · click to enlarge
Page 16

Configuration: Netw ork

Enable DHCP: Change the way to get IP address for PDU.

PDU PDU Power Distribution Unit — Configuration: Netw ork diagram (page 16)
Fig. 10 · Configuration: Netw ork

PDU network information

Page 17 of the PDU PDU Power Distribution Unit user manual — Configuration: Mail
Page 17 · click to enlarge
Page 17

Configuration: Mail

When event occurs, PDU can send out email message to pre-defined account.

Em ail Server: The Email Server only support to be input domain name, not IP address.

Sender’s Em ail: Input the sender email address.

Em ail Address: Input the recipient email address.

The message in the email: Indicate OutletA~ H-XXXXXXXX status in order X= 0 : means the power off. X= 1 : means the power on.

PDU PDU Power Distribution Unit — Configuration: Mail diagram (page 17)
Fig. 11 · Configuration: Mail
Page 18 of the PDU PDU Power Distribution Unit user manual — Configuration: SNMP
Page 18 · click to enlarge
Page 18

Configuration: SNMP

When event occurs, PDU can send out trap message to pre-defined IP address.

Trap Notification: Set receiver IP for trap.

Com m unity: Set SNMP community. Read Community is public and fixed. Default Write Community is “public” and can be modified by user.

PDU PDU Power Distribution Unit — Configuration: SNMP diagram (page 18)
Fig. 12 · Configuration: SNMP
Page 19 of the PDU PDU Power Distribution Unit user manual — Configuration: SSL
Page 19 · click to enlarge
Page 19

Configuration: SSL

Enable SSL for web communication.

User must input the correct ID and password to enable SSL function. The ID and password must be the same with the setting in “User”.

PDU PDU Power Distribution Unit — Configuration: SSL diagram (page 19)
Fig. 13 · Configuration: SSL

Ask about the PDU PDU Power Distribution Unit

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the PDU PDU Power Distribution Unit

Be the first to ask — other owners or our team will answer.

Original document

PDU PDU Power Distribution Unit manual PDF

19 pages·348 KB·Power Distribution Unit·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…