Quick Start Installation Guide

Command Centre Boiling/Chilled models

Visit our website to download the manuals
Australia UK



This document is a Quick Start Installation Guide. For further details on installing and operating your HydroTap download & read the Command Centre installation and user instructions , which can be found online at: (Australia) www.zipwater.com (UK) specify.zipwater.co.uk !
Read and use the instructions supplied with individual kit components for a safe installation.
!
Hot surface Highly Flammable
Read the instructions

!
Compliance In Australia electrical installation must comply with AS/NZS3000. In Australia plumbing installation must comply with AS/NZS3500. In Australia For residential chilled models, all refrigeration must comply with AS/NZS 60335.2.24. In the UK the system must be installed in accordance with water supply byelaws, current IEE regulations and local authority byelaws.
Safety This appliance is not intended for use by children under 8 years or persons (including children under 8 years) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Refrigerant
The Zip HydroTap Command Centre range uses either HIGHLY FLAMMABLE R290, R600a or R134A refrigerant under pressure. Check the rating plate or contact Zip before commencing work. Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration technician. Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. Qualifications To avoid hazards, all installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power outlet must be in a safe visible position for connection.

Venting Sometimes steam and / or boiling water droplets may discharge through a vent outlet on the tap. If not using the font, ensure the tap body is located so the tap outlet safely dispenses into the sink bowl. Lifting Take care when lifting. The Command Centre may exceed safe lifting limits. If you feel this is beyond your personal capabilities, please seek assistance with the lift. The weight of the Command Centre is marked on the packaging. Do not lift the Command Centre by the front cover or any of its connections. Airflow The Zip HydroTap operates within the ambient temperature range 5ºC - 35ºC. Proper air circulation must be provided. The system will operate satisfactorily only if the recommended air gaps are provided. The vent kit supplied must be fitted. Altitude Water boils at varying temperatures at different altitudes. The HydroTap adjusts for this during startup calibration and will recalibrate itself on a regular basis. Frost protection If the HydroTap is located where the ambient air temperature could fall below 5ºC when the system is not in use, do not turn off the Command Centre electrically. This safeguard does not offer the same protection to the connecting pipework and fittings.

•


* power rating of the booster #Including vent tray
Electricity supply requirements 220-240V 50Hz AC (for power requirement see table above).

Water supply pressure requirements
A pressure limiting valve must be fitted for mains water pressures above the maximum limits stated above in accordance with local plumbing regulations. Note: All models (excluding UK) have an internal pressure limiting device to reduce the maximum mains regulated pressure (700kPa in Australia), protecting the system against pressure surges above 500kPa.
Water supply connection 1/2” BSP (G1/2).
Booster specification



! Use of tools can be hazardous. Assess the risks before you start.
Use instructions supplied with individual kit parts.
A clearance envelope around all Command Centres must be provided to allow ventilation for the safe and effective use of the HydroTap system.
200mm · 50mm 50mm · Command Centre width

BC100 - BC40 models

The vent tray must be fitted. It provides a safe exhaust for refrigerant gas in the unlikely event of a leak. !
Vent tray

BC30, BC20 & Home models

4mm door buffers (supplied)
If cupboard temperature exceeds 35°C, additional ventilation is required. Contact your Zip service provider for options (including additional vents and fan kit).
Air inlet · Inlet vent · All models


Valves and fittings must be sealed with PTFE tape if compression seals are not included.

Available as optional accessory - UK only.
For filter head and scale filter installation use the guide supplied with the filter head and filter respectively.
out Bypass in see pages 19,20
in Bypass out see pages 19,20
Bypass valve (Rear of the Command









Do not connect to electrical power until commissioning. Do not over tighten hose connections. Braided hoses supplied cannot be lengthened.
Hot water out of Booster, connect to Command Centre

For HydroTap, mixer tap and any optional accessories, use instructions supplied with individual kit components.

Do not connect to the mains socket until commissioning
Installation diagrams are for illustrative purposes only. Hoses are not shown to scale and cannot be lengthened. !


Diagram for illustrative purposes only. Hoses are not shown to scale, as the booster hoses cannot be lengthened.
InLine E L E C T R O N I C


Diagram for illustrative purposes only. Hoses are not shown to scale, as the Booster hoses cannot be lengthened.
InLine E L E C T R O N I C



Follow the prompts to flush fresh water through the
tank/s 3 times as shown by the cycle counter/s.
The tank/s will fill automatically but when prompted use the tap to dispense and empty.
Dispense water from the hot tank using the taps



Refer to User Guide for operation and maintenance.

Zip Water (Australia) Pty Ltd
ABN 46 000 578 727 67 - 77 Allingham Street, Condell Park NSW 2200 Postal: Locked Bag 80, Bankstown 1885
Australia Tel (+612) 9796 3100 Free call 1800 947 827 (1800 ZIP TAP)
WMKA00099
AS 3498
Zip Water UK Trafalgar House, Rash’s Green,
Dereham, Norfolk, NR19 1JG
0345 6 005 005 sales@zipindustries.co.uk
specify.zipwater.co.uk
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.