TF-Luna LiDAR Module

Company: Benewake (Beijing) Co. Ltd.
This document is protected by copyright. All rights related to it belong to Benewake (Beijing) Co. Ltd.
Reproduction of all or part of this document is permitted only within the scope of copyright law. No
modification, deletion, or translation of this document is permitted without the official written permission of
All rights reserved © Benewake (Beijing) Co. Ltd.




Thanks you for choosing Benewake products, and it’s our pleasure to help you with any technical
question.
To have a better experience, please read this manual carefully. We try to contain all common problems
and hope you find the deployment and installation easy and fun.
This manual will guide you through the installation and operation process and show you some solution
of common problems. It is still possible that you encounter some difficulties that are not included,
please check our support service (supprt@benewake.com) and don’t hesitate to contact our support
consultants or leave a message on our feedback page on our official website:
http://benewake.com/en/mfeedback.html
We hope you enjoy our product and join our community!
We are Benewake! Our goal is to make the best “Robotic Eyes” in the world!
Dear users,







2.1 About document
This manual provides all essential information you may need during the usage of this product.
Please read this manual carefully before using this product and make sure that you are fully
understand the contents of the manual.
The product can only be maintained and repaired by qualified professionals, and only original
spare parts are permitted to use for performance and safety reasons.
This product DO NOT have polarity and over-voltage protection at all. Please wire and supply
power according to the instructions.
The working temperature of the product is from -10℃ to 60℃, please do not use it outside this
temperature range to avoid risk and damage.
The storage temperature of the product is from -20℃ to 75℃, please do not store it outside
this temperature range to avoid risk and damage.
For safety and performance, please DO NOT open the product casing or remove the IR-pass filter.
Detecting object with high reflectivity, such as mirrors, smooth floor tiles, and calm milk liquid.
Blocking the product with any transparent objects, such as water or glasses.
The product’s lenses may be covered by dusts or dirt which may affect results, so please keep

those lenses clean.
The exposed circuit board is electrostatic sensitive. Please do not touch the circuit board of the
product barehanded. Please use ESD wrist strap or antistatic gloves to ground yourself if any
operation is necessary; Otherwise, the product may be damaged by static electricity.
3.1 Ranging Principle
TF-Luna is using Time of Flight (TOF) principle to measure distance, and it periodically emits near
infrared modulated waves. TF-Luna calculates the time by measuring the phase difference between the
original wave and the reflection wave and uses that time to get relative distance, as shown in Figure 1.


Operating range 0.2m~8m①
±6cm@ (0.2-3m) ②
Measurement unit cm (Default)
Frame rate 1~250Hz ( adjustable ) ③
① Operating range measured indoor based on a standard whiteboard with reflectivity 90% .
② This is theoretical, real value may be different.
③ 100Hz as default and only any factor (500/n, n can be any integer in [2, 500]) of 500Hz are available.

TF-Luna's ranging accuracy is positively correlated with the strength value (amp) and negatively
correlated with the output frame rate (frequency). The tables below show the standard deviation (STD)
using 100Hz output rate. These values are for reference only, various testing environments may give
different results.
Table 2 STD Amp correlation

Table 3 STD Dist correlation with 90% diffuse reflectance object
TF-Luna minimize the impact of external environment on ranging performance by optimizing light
path and algorithm.
TF-Luna’s ranging dead zone is 20 cm or closer. Any distance output less than 20 cm is unreliable. The
operating range of black and white targets are different:
The operating range of TF-Luna detecting black target with 10% reflectivity is 0.2-2.5m; The operating
range of TF-Luna detecting white target with 90% reflectivity is 0.2-8m.
The ranging data are reliable only if the reflection surface fully covers the light spot, so the diameter
of the object must at least the same as the diameter of the light spot, and that diameter depends on FOV
of TF-Luna. The minimum diameter of the object surface has a formula:
d = 2 ∗D ∙tanβ
In the formula, d represents the minimum diameter, D is the distance of the object, and β is the half
FOV of TF-Luna. Common values are shown in table 4 for your convenience:

Table4 Distance and minimum diameter

If the light spot reaches two objects with different distances as Figure 2, the output distance value
will be any value between the two actual distances of the objects, which may cause error for high-accuracy
applications. Please try to avoid this situation for better accuracy and performance.

Figure 2 Detecting two objects at different location
4.1 Appearance

Figure 3 TF-Luna appearance and size drawing


This product has no overvoltage nor polarity protection, so please make sure that the product is well
connected, and the power supply voltage is inside the given range.
6.1 Description about Line Sequence and Connection

Figure 4 TF-Luna’s pin numbers


Serial port Communication starts when pin 5 is disconnected or connected to 3.3v. It will set TF-Luna
receiving RXD from pin 2 and sending TXD on pin 3. The serial port communication protocol is defined as
follows: 8 data bits, 1 stop bit with no parity check and default baud rate of 115200 bps.
Serial port Communication Protocol data byte format:

Head: Fixed 0x5A.
Len: The length of bytes from the head byte to check-sum at the end, and it has to between 4 to 255.
ID: Indicates how to parse the Payload data.
Payload: Payload data segment, Optional.
Checksum: The lower 8 bytes of the sum from Head the Payload.
Please check Appendix II Serial communication protocol for more information.
TF-Luna are not being check as default. Thus, ANY value is acceptable on the Checksum byte, unless
checking of those bytes are required. Please check “Enable/disable checksum comparison
ID_FRAME_CHECKSUM_EN=0x08” in Appendix II Serial communication protocol to enable the feature.
The instruction makes change immediately after sending, but the current setting is not saved and will
lose after reboot. User must use “Save current setting ID_SAVE_SETTINGS=0x11” to save the change. The
full save-current-setting11s hexadecimal string is 5A 04 11 00 in this case.
When pin 5 is connected to ground, TF-Luna enters I2C mode, then its pin 2 is use as SDA data and
pin 3 is the SCL clock sending data. TF-Luna support up to 400kps clock speed as slave machine and its
default address is 0x10. For more information about I2C register table Appendix III I2C register table.
Write register timing:
Start Slave Addr W Ack Register Addr Ack Data1 Ack … DataN Ack Stop

Read register timing:
Start Slave Addr W Ack Register Addr Ack Stop
Start Slave Addr R Ack Data1 Ack … DataN Nack Stop
is also working while replacing the last Nack signal.
In the continuous ranging mode, the host must monitor pin 6 for synchronous signal and initiate the
read data operation in time. Otherwise, it may cause an error by reading and updating the data register at
the same time. In multi-machine bus mode, use command to trigger reading is strongly recommended.

Figure 5 Timing of reading data register in I2C mode
Pin 6 is normal low level and it switches to high as soon as the data is updated. It switches to low
level only if a read operation on any register is done. Therefore, I2C host must read the register when
receive a high level on pin 6 in the continuous ranging mode. As the figure has shown above, the first
result in red is unreliable and the rest two in green are accurate.
To writing the configuration value to the I2C register does not take effect immediately, nor will the
power outage be saved, but writing 0x01 to address 0x20 will save the current register value and take
effect after restarting. If the written configuration value is invalid, the register value remains valid.
Generally, only writable register addresses take effect immediately after being written.
Normally write registers that are only writable are saved and start working immediately. However,
changing a value of an I2C register is not. The changed value in I2C register are saved and effective after
reboot only if the new value is valid and address 0x20 is written with value 0x01.

TF-Luna normally provide these data below:
⚫ Distance (Dist): Default in centimeters.
⚫ Signal strength (Amp): Distance value is unreliable when receiving signal is overexposure (Amp =
0xFFFF) or too low (Amp < 100 as 14).
⚫ Chip Temperature (Temp): Celsius degree = Temp/8 - 256℃
TF-Luna supports various serial format, please check Appendix I Serial port output format for more
information, and the default setting is 9-bytes/centimeter. Format setting is in “Output format setting
ID_OUTPUT_FORMAT=0x05” section.
TF-Luna will keep tracking the distance 500 time per second, but as the customized output frequency
is lower, the output may take the average. For instance, if the output frequency is 100Hz as default, then
the output values are the average (arithmetic mean) of 5 previous range data. Therefore, lower output
frequency gives less time of the averaging process as well as less fluctuation of the output. The highest
output frequency that TF-Luna supports is 250Hz (output_frequency ≤ 250Hz), and it must be 500/n Hz (n
is an integer that in the range [2, 500]). Thus, all supported values of output frequency are: 250Hz, 166Hz,
125Hz, 100Hz, …, 2Hz, 1Hz. User can change the output frequency using “Output frequency
ID_SAMPLE_FREQ=0x03”.
TF-Luna enters trigger mode if the output frequency is set to be 0 with “Output frequency
ID_SAMPLE_FREQ=0x03”. In this mode, TF-Luna stops measuring and outputting unless it is triggered by
“Trigger mode ID_SAMPLE_TRIG=0x04” — in other words, TF-Luna measures and output once as soon as
it receive the hexadecimal byte string 5A 04 04 00.
On/off mode is designed from those users only need to detect the existence of an object. TF-Luna
can start this mode using “Enable/disable on-off mode ID_ON_OFF_MODE=0x3B” and then shows result
through pin 6. Figure 7 below shows how the mode works when a high level is set to represent an object

is detected.

Figure 6 On/off mode that high level means closer
Zone value: If an object is detected closer than Dist, then Pin 6 outputs high-level, but only if an object
is detected farther than Dist + Zone, then Pin 6 outputs low-level. When zone is set to 0, pin 6 may output
up and down cause by fluctuation of the measuring when the real distance happens to be the same as
Dist. That is why a proper zone value is needed to help avoid this situation by having a hysteretic interval.
Delays is also supported to avoid inaccurate jumping output. Pin 6 changes its output depends on the
Dist value condition and the time it last. Delay1(ms) and Delay2(ms) determine how long that approaching
changes and leaving changes should wait after Dist value is already over the line.
low, then pin 6 may have false output in the on/off mode. Please follow the instructions in 6.8 Amp
threshold to set the over-threshold value greater than Dist + Zone to avoid false output.
The distance calculation may get false result if the Amp value is too low, so TF-Luna set the Dist value
to dummy_dist(Default 0) when Amp is lower than amp_threshold (Default 100). If user need to change
the Amp threshold value, please follow instructions in “Amp threshold setting
ID_AMP_THRESHOLD=0x22”. Note that the final Amp threshold in TF-Luna is 10 times the value you send
to it.
TF-Luna has a default maximum and minimum distance output: [min, max] = [0cm, 800cm]. User can
change the output limits using “Distance limit setting ID_DIST_LIMIT=0x3A”.

TF-Luna supports power saving mode for power sensitive applications, it reduces its power
consumption by adjusting both current level and duty cycle of the light source. With 5V power supply,
TF-Luna’s power consumption on Continuous ranging mode is about 350mW as the light source switch to
highest current level and duty cycle.
When TF-Luna is on power saving mode, it dynamically adjusts the current of the light source by
switching several preset current levels according to the strength (amp) of the receiving signal. Therefore,
TF-Luna can get a stable amp value and save power consumption at the same time.
Users may reduce the duty cycle in different ways: to use trigger mode (about 42.5mW with 5V power
supply) to turn the light source off while waiting, or to enable power saving mode. Power saving mode
also turns the light source off, but it lets TF-Luna generate trigger signal periodically and automatically.
The maximum sample frequency that gives TF-Luna a stable timing is 10Hz.
Please follow the format in “Enable/disable Power saving mode (ECO)
ID_LOW_CONSUMPTION=0x35” section to enable power saving mode with listed working frequencies.
The average current and power are measured with 5V power supply and the actual value might be
different in various environment, especially different temperature or other power supply.


Please check Appendix II Serial communication protocol for more options, such as version ID report,
system software restore, baud rate configuration, etc.
7.1 Required tools for testing






USB cable PC PC software
① Download and install the latest Test software
Please visit our official website (en.benewake.com) and download the Test software of TF-Luna.
software may regard the ‘.exe’ file as virus. Also, released versions are only running on Windows systems
currently.
② Connecting Hardware and cables

Figure 7 Schematic Diagram of Correct Connection
Please connect TF-Luna, TTL - USB converter, and USB cable properly as shown in 5. Please check
if there is any loose connection, and then plug the USB cable into your PC.
TTL to USB · TF-Luna Data cable · convertor

③ Open your Test software and check data output
Open the PC software and select “①TF-Luna” and select automatically recognized occupied serial port (in
this case “② COM9”) as shown in Figure 6
Now click the “CONNECT” button, and a continuous images of the output data will be displayed in area
“④ TIME LINE CHART” on the right if everything is connected successfully. The real-time data of the
Current measure distance (Dist), effective data points per second (Effective Points) and signal strength
(Strength) will be displayed in area “⑥ REAL TIME DATA” below as well.

a) If nothing is displayed in area “④TIME LINE CHART”, please check the wire connection and
sequence. A red LED indicator inside the transmitting lens at front will light up when TF-Luna is
power-on.
b) Please select “③Pix Mode” before switching TF-Luna’s outputs to Pixhawk format to avoid
abnormal data display in the “④TIME LINE CHART” area. Note that slecting Pix Mode will
automatically set the unit of distance to meters.
c) Since TF-Luna does not pass unit information and the software always use centimeters as distance
unit, the distance unit displayed in the chart remains the same as centimeter even if TF-Luna
output in millimeter. For instance, suppose the actual measurement is one meter and the distance
value from TF-Luna is 1000 mm, then the value read by the PC software is 1000. Thus, the
software will display 1000 with unit cm.
④ ① ②

TF-Luna allows upgrading firmware remotely when current firmware no longer support users’ new
requirements. Please contact us for the additional remote upgrading software if any relevant firmware
upgrades are available on Benewake official website.

The tools for an upgrade are mostly the same as those in the Quick Test Guide, including a TTL/USB
convertor to connect TF-Luna with PC.
Open the Updater.exe after connecting TF-Luna to your PC, and then select the correct port and baud
rate, “①COM8” and “② 115200” in this case. Click “④ Open Bin” to choose the updating firmware, then
the file directory will be displayed in the textbox above. Finally, click “⑤ Download Bin” to start upgrading
and the upgrading information will show up in “⑥”.

1. 9-byte/cm (Default)
This format is supported for any firmware after Ver. 0.0.5
Byte 0 1 2 3 4 5 6 7 8
Description 0x59 0x59 Dist_L Dist_H Amp_L Amp_H Temp_L Temp_H Check_sum
Amp: Signal strength indicator. Dist value is unreliable when Amp < 100 or Amp = 65535 (Overexposure)
This format is supported for any firmware after Ver. 0.0.5
“X.YZ\r\n” is a sample ASCII string and only keep two significant digits in meter where “X.YZ” is the result.
This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 3 4 5 6 7 8
Description 0x59 0x59 Dist_L Dist_H Amp_L Amp_H Temp_L Temp_H Check_sum
Amp: Signal strength indicator. Dist value is unreliable when Amp < 100 or Amp = 65535 (Overexposure)
This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 3 4 5 6-9 10
Description 0x59 0x59 Dist_L Dist_H Amp_L Amp_H Timestamp Check_sum
Amp: Signal strength indicator. Dist value is unreliable when Amp < 100 or Amp = 65535 (Overexposure)
This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 3 4 5 6 7-10 11
Description 0x5A Len 0x00 Dist_L Dist_H Amp_L Amp_H Timestamp Check_sum
Amp: Signal strength indicator. Dist value is unreliable when Amp < 100 or Amp = 65535 (Overexposure)
This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 3 4-7
Description Dist_L Dist_H Amp_L Amp_H Timestamp

Amp: Signal strength indicator. Dist value is unreliable when Amp < 100 or Amp = 65535 (Overexposure)

1. Version information ID_GET_VERSION=0x01
This format is supported for any firmware after Ver. 0.0.5
Downward:
byte 0 1 2 Len-1
Description Head(0x5A) Len ID Check_sum
Upward:

*Version: For instance, if the third, fourth, and fifth bytes are 112, 50, 9, then the version is 9.50.112
This format is supported for any firmware after Ver. 0.0.5


This format is supported for any firmware after Ver. 0.0.5

Freq: Working frequency if Freq > 0, and Trigger mode if Freq = 0.
byte 0 1 2 3~4 Len-1
Description Head(0x5A) Len ID Freq Check_sum
Sample instruction:
10Hz [5A 06 03 0A 00 00]
250Hz [5A 06 03 FA 00 00]

This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 Len-1
Description Head(0x5A) Len ID Check_sum
This format is supported for any firmware after Ver. 0.0.5

Format:
0x07 = 32-byte with timestamp
byte 0 1 2 3 Len-1
Description Head(0x5A) Len ID Format Check_sum
This format is supported for any firmware after Ver. 0.0.5

byte 0 1 2 3~6 Len-1
Description Head(0x5A) Len ID Baudrate Check_sum
Baudrate: TF-Luna’s current baudrate.
Example:
9600 [5A 08 06 80 25 00 00 00]
19200 [5A 08 06 00 4B 00 00 00]

38400 [5A 08 06 00 96 00 00 00]
57600 [5A 08 06 00 E1 00 00 00]
115200 [5A 08 06 00 C2 01 00 00]
230400 [5A 08 06 00 84 03 00 00]
460800 [5A 08 06 00 08 07 00 00]
921600 [5A 08 06 00 10 0E 00 00]
This format is supported for any firmware after Ver. 0.0.5

Enable: 0 to disable, 1 to enable.
byte 0 1 2 3 Len-1
Description Head(0x5A) Len ID Enable Check_sum
Example:
Enable output [5A 05 07 01 00]
Disable output [5A 05 07 00 00]
This format is supported for any firmware after Ver. 0.0.5

Enable: 0 to disable, 1 to enable.
byte 0 1 2 3 Len-1
Description Head(0x5A) Len ID Enable Check_sum
Example:
Enable checksum comparison [5A 05 08 01 00]
Disable checksum comparison [5A 05 08 00 67]
This format is supported for any firmware after Ver. 1.0.0


byte 0 1 2 3 Len-1
Description Head(0x5A) Len ID I2c_slave_addr Check_sum
Example:
Change to 0x20 [5A 05 0B 20 00]
This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 Len-1
Description Head(0x5A) Len ID Check_sum
byte 0 1 2 3 Len-1
Description Head(0x5A) Len ID Status Check_sum
Example:
Restore default setting [5A 04 10 00]
This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 Len-1
Description Head(0x5A) Len ID Check_sum
byte 0 1 2 3 Len-1
Description Head(0x5A) Len ID Status Check_sum
This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 Len-1
Description Head(0x5A) Len ID Check_sum
byte 0 1 2 3-16 Len-1
Description Head(0x5A) Len ID Bin Check_sum
Example:
Send [5A 04 12 00]
0x55 0x30 0x39 0x30 0x30 0x30 0x31 0x38 0x30 0x31 0x30 0x30 0x30 0x31

This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 Len-1
Description Head(0x5A) Len ID Check_sum

byte 0 1 2 3-10 11 12-19 20 21-22 23 24-25 26 27-28 Len-1
This format is supported for any firmware after Ver. 0.0.5

Amp_Threshold: When Amp < Amp_Threshold * 10, then output Dummy_Dist instead of the result of calculation
Dummy_Dist: The output distance when Amp is too low.
byte 0 1 2 3 4-5 Len-1
Description Head(0x5A) Len ID Amp_Threshold Dummy_Dist Check_sum
Example:
To output 500 cm when Amp < 300 [5A 07 22 1E F4 01 00]
This format is supported for any firmware after Ver. 0.0.5

Example:
To set timestamp to 1000ms [5A 08 31 E8 03 00 00 00]
This format is supported for any firmware after Ver. 0.0.5


byte 0 1 2 3-4 Len-1
Description Head(0x5A) Len ID Sample_rate Check_sum
Example:
Enable power saving mode and measure at 10Hz frequency [5A 06 35 0A 00 00]
This format is supported for any firmware after Ver. 0.0.5

Dist_min: minimum distance output in centimeters.
Dist_max: maximum distance output in centimeters.
Silence: Not output when the distance is out of range if silence = 1. Output limit when out of range if silence = 0
byte 0 1 2 3-4 5-6 7 Len-1
Description Head(0x5A) Len ID Dist_min Dist_max Silence Check_sum
Example:
Output limit when out of range with the minimum set to be 20cm and the maximum set to be 500cm
[5A 09 3A 14 00 F4 01 00 00]
This format is supported for any firmware after Ver. 1.0.0

byte 0 1 2 3 4-5 6-7 8-9 10-11 Len-1
Head(0x5A) Len ID Mode Dist Zone Delay1 Delay2 Check_sum
Mode: 0 (Normal output) , 1 (On-off mode with high level output when closer) , 2 (On-off mode with low level output
Dist: critical dist value (the closer one) in centimeters.
Delay1: Delay time 1 in millisecond. Pin 6 switch level only if the distance detected is less than Dist and the situation last
for Delay1 long.

Delay2: Delay time 2 in millisecond. Pin 6 switch level only if the distance detected is more than Dist + Zone and the
situation last for Delay2 long.
Example:
Enable on-off mode with high level output when closer, and set Dist = 200cm, Zone=10cm, Delay1 = Delay2 = 1000ms:
[5A 0D 3B 01 CB 00 0A 00 E8 03 E8 03 00]
This format is supported for any firmware after Ver. 0.0.5

Output_period_s: Only work when a positive number is given which means the time period of outputs are longer than
one second and the output frequency is less than 1Hz.
One_shot_frames: This only work when sample_freq and output_period_s are valid. Only if output_period_s > 0, then
the laser turns on every output_period_s second and then output the average output of one_shot_frames results.
byte 0 1 2 3-6 7-10 Len-1
Description Head(0x5A) Len ID Output_period_s One_shot_frames Check_sum
Example:
To measure once every 300 seconds and keep working for 1 second, user can let sample_freq = 1, output_period_s = 300,
one_shot_frames = 1 [5A 06 03 01 00 00] [5A 0C 3E 2C 01 00 00 01 00]
This format is supported for any firmware after Ver. 0.0.5
byte 0 1 2 3 Len-1
Description Head(0x5A) Len ID Id Check_sum
Id: The same as we mentioned above.
Upward: The same format of relevant Id.
Example:
Read output frequency [5A 05 3F 03 00]
Downward · Upward · Downward


R SN -- Production code in 14 bytes ASCI
0x20 W SAVE -- Write 0x01 to save current setting


0x29 W RESTORE_FACTORY_DEFAULTS -- Write 0x01 to restore factory default
0x2E W/R MIN_DIST_LOW 0x00 Minimum dist in cm, but not working
0x30 W/R MAX_DIST_LOW 0x20 Maximum dist in cm, but not working
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.