Page 2 of the SentrySafe Fire-Safe Electronic Lock user manual — Getting started
Page 2 · click to enlarge
Page 2

always open the safe by entering the pre-set 5-digit

program the safe to open using a 5-digit user code

3. User pin If you wish to give someone else temporary access

to the safe, you can program a 5-digit user pin that

handle can be returned to the horizontal position.

corner of the door may be required before the

There are 3 possible ways to unlock and access

1. Factory code (Found on the fi rst page of this guide) You can
2. User code If you prefer to employ your own code, you can

resistant gasket additional pressure to the left

factory code. This code cannot be deleted.

1. Press the Prog key , then enter the 5-digit factory code.
2. Enter the 5-digit user code of your choice.

please check batteries before calling Sentry

3. Enter the 5-digit user pin of your choice.
1. Press the Prog key. 2. Enter the 5-digit factory code twice.

fi re/water-resistant and security storage. This guide describes how to easily set up your safe. 2 Gain entry with the basic electronic lock

Programming the user code

1. Press the Prog key 2 times.
2. Enter your 5-digit user code.
1. Press the Prog key 2 times.
2. Enter your 5-digit user code.

can later be erased.

3. Enter 0, 0.

Customer Care.

of your choice.

To delete:

To delete:

the safe:

To add:

To add:

1. Remove and discard the screw (if equipped) at the base of the lock case.

2 o’clock, and remove. • Insert 4 new AA batteries (not included) to power this lock.

4. Enter the factory code (printed on the fi rst page of this guide). When the green light appears, you

open. Try this several times before proceeding to

The handle should be all of the way UP, in

the horizontal position before attempting

Opening your safe for the fi rst time (keep

2. Turn the electronic lock case to the right (clockwise), from 12 o’clock to
  • Replace the electronic lock case and turn to the left (to 12 o’clock) to reassemble.
3. Turn the key (if your safe is equipped with a key lock) to the right so the lock cylinder pops out.

have four seconds to turn the handle down to

Enter the 5-digit factory code, a pre-programmed

horizontal position. For greatest security, depress

(programming instructions to follow). When the

green LED lights you have 4 seconds to turn the

SentrySafe Fire-Safe Electronic Lock — Gain entry with the combination lock diagram (page 2)
Fig. 1 · Gain entry with the combination lock

Close the door and return the handle to the

door open during setup):

user code, or a pre-programmed user pin

the key lock (if equipped) with your fi nger.

handle and open the safe.

need to be replaced.

To unlock safe:

to open safe.

the next step.

To lock safe:

1. To unlock and open Before dialing your combination, simply insert the

passes the pointer at least FOUR times. Then stop

D. Turn the dial to the left. Stop the SECOND

B. Turn the dial to the left. Make sure ZERO

C. Turn the dial to the right. Stop the THIRD

E. Turn the dial to the right. Stop the FIRST

(Make sure the door handle is in the horizontal

key (if equipped) in the lock and turn until the

time you reach the combination’s third number.

2. To close and lock You can relock the safe in two ways. With the

door closed, depress the key lock (if equipped)

with your finger, or spin the combination dial

one full turn. For greatest security, do both.

time you reach the second number of your

at the first number of your combination.

time you reach the last number of your

Congratulations on your purchase of a Sentry®Safe product. SentrySafe is the world’s leader in

plunger pops out. Remove key.

4-NUMBER COMBINATION (Cannot be changed)

Opening your safe for the fi rst time (keep door open during setup): 1

A. Point the dial to zero.

Gain entry with the combination lock

combination.

combination.

position.)

You will have a 3-number or 4-number combination

1. To unlock and open Before dialing your combination, simply insert the

passes the pointer at least THREE times. Then stop

time the pointer reaches the third number of your

with your finger, or spin the combination dial one

sure the door handle is in the horizontal position.)

Testing your combinationYour safe’s combina-

tion is printed on the front of this owner’s manual.

B. Turn the dial to the left. Make sure ZERO

The handle should be all of the way UP, in

the horizontal position before attempting

key (if equipped) in the lock and turn until the

SECOND time you reach the second number of

D. Turn the dial to the left. Stop the FIRST

2. To close and lock You can relock the safe in two ways. With the

door closed, depress the key lock (if equipped)

full turn. For greatest security, do both. (Make

C. Turn the dial to the right. Stop the

at the first number of your combination.

depending upon the model purchased.

3-NUMBER COMBINATION (Cannot be changed)

plunger pops out. Remove key.

pressed in with or without key.

A. Start the dial at zero.

Getting started

your combination.

to dial out safe.

combination.

Programming user pin · Access codes

Page 3 of the SentrySafe Fire-Safe Electronic Lock user manual — Gain entry with advanced electronic lock 3
Page 3 · click to enlarge
Page 3
3. Enter a 4 to 8 digit code in the selected position and press the Prog/Enter key to fi nish.
1. Press the Prog/Enter key, then enter the 5-digit factory code and then press the Prog/Enter key.

) indicates there is a

seconds and the lock will time-out. You may then

2. Use the > to scroll between the lighted boxes. An empty box icon (
2. Use the > to scroll to the boxed lighted * icon (
3. Press 0, then the Prog/Enter key to delete the selected user. (0, Prog/Enter).
3. Enter a 4 to 8 digit code and press the Prog/ Enter key to fi nish programming the code into
1. Press the Prog/Enter key 2 times, enter the manager code and then press the Prog/Enter
1. Press the Prog/Enter key 2 times, enter the manager code and then press the Prog/Enter

key and then the Prog/Enter key. (0, Prog/Enter).

3. Press 0, then the Prog/Enter key to delete the manager code. (0, Prog/

programming a manager or user code, wait 5

) means it is

available for a code entry; a boxed lighted *

code programmed and can be deleted.

) means it is being used.

Gain entry with advanced electronic lock cont. 3

) to be removed.

2. A boxed lighted * icon (

the unit.

To delete:

start over.

To delete:

Enter).

To add:

key.

key.

3. You have let 5 seconds or more elapse between key presses.

(Program) Lights after pressing the Program

always open the safe by entering the pre-set 5-digit

1. You have pressed Program key out of sequence.

key and stays lit while programming a manager or

program the safe to open to a 4-8 digit manager

3. User code If you wish to give someone else temporary access

to the safe, you can program a 4-8 digit user code

access codes, open the unit fi rst then test it with

1. Press the Prog/Enter key , then enter the 5-digit factory code and then press the Prog/Enter key .

(Delay Mode) Lights after three consecutive

There are 3 possible ways to unlock and access

and manager codes, and store them in a secure

2. Manager code If you prefer to employ your own code, you can

) means no manager

code is programmed. A boxed lighted * icon

4. You have pressed a key while in delay mode.

invalid codes are input and stays lit during the

1. Factory code (Found on the fi rst page of this guide) You can

) means a manager code is programmed.

(Error) indicates one of the following:

the door open. All zeros is an invalid code.

factory code. This code cannot be deleted.

2. You have entered an invalid code.

Programming the manager code

location other than in this safe.

that can later be erased.

2. An empty lit box icon (

2-minute delay mode.

code of your choice.

user code.

the safe:

To add:

batteries need to be replaced. No codes are erased

1. Comes ON after you enter a valid code and remains lit during the 4-second period in which

) appears, you have four seconds to turn

handle can be returned to the horizontal position.

Enter the 5-digit factory code, a pre-programmed

(programming instructions to follow), then press

horizontal position. For greatest security, depress

when old batteries are removed for replacement.

manager code, or a pre-programmed user code

the Prog/Enter key. When the unlocked padlock

resistant gasket. Additional pressure to the left

corner of the door may be required before the

2. Comes ON in the Programming mode and remains lit until you have fi nished entering
1. Comes ON when the batteries need to be replaced.

Close the door and return the handle to the

please check batteries before calling Sentry

the key lock (if equipped) with your fi nger.

) will light when the

See “Opening your safe for the fi rst time”.

the safe can be opened.

the handle down to open.

Gain entry with advanced electronic lock 3

Gain entry with basic electronic lock cont. 2

Green LED only:

Yellow LED only:

a 5-digit code.

To unlock safe:

The battery icon (

To lock safe:

Customer Care.

Your electronic-lock safe communicates by means

1. You have pressed Program key out of sequence.
3. You have let 5 seconds or more elapse between key presses.
1. Remove and discard the screw (if equipped) at the base of the lock case.
  • Replace the electronic lock case and turn to the left (to 12 o’clock) to reassemble.
3. Turn the key (if your safe is equipped with a key lock) to the right so that the lock cylinder pops
4. Enter the factory code (printed on the fi rst page of this guide), then press the Prog/Enter key.

you have four seconds to turn the handle down

to open. Try this several times before proceeding

4. Lights after three consecutive invalid codes are input (2-minute delay mode).

Opening your safe for the fi rst time (keep

2. Turn the electronic lock case to the right (clockwise), from 12 o’clock to

Red (Error) LED + three beeps indicates

2. You have entered an invalid code or user pin.

2 o’clock, and remove. • Insert 4 new AA batteries (not included) to power this lock.

SentrySafe Fire-Safe Electronic Lock — Gain entry with advanced electronic lock 3 diagram (page 3)
Fig. 2 · Gain entry with advanced electronic lock 3

When the unlocked padlock icon (

of several audio/visual signals.

door open during setup):

one of the following:

to the next step.

out.

Show 9 more labels / short text on this page
Programming user code · icon ( · Icon identifi cation · Access codes · ( · Battery replacement · icon ( · ) appears, · Signals
Page 4 of the SentrySafe Fire-Safe Electronic Lock user manual — A
Page 4 · click to enlarge
Page 4
SentrySafe Fire-Safe Electronic Lock — WARNING diagram (page 4)
Fig. 3

performance standard indicated guarantees.

No computer disks, audio-visual

photo negatives. For fire-resistant storage

the SentrySafe Fire-Safe Media storage

Therefore, DO NOT store pearls in your

This product is not intended to protect

computer floppy or diskettes, cartridges

of these materials, ask your retailer for

In this mode, the lock can not be activated and

measure which the UL classification

media or photo negatives.

and tapes, audio or video cassettes or

RegistrationTo be eligible for warranty coverage, the original purchaser must register

number can be found near the door hinge as

the product online at www.sentrysafe.com or complete and return to Sentry Group

WARNING

If you lose your combination/keys or need accessories, we can help!

SentrySafe product.

products.

Sentry ® Safe First-Class Customer Care

container, prior to placing them in the safe

delicate pearls occurs at temperatures much

lower than the 350°F interior performance

accumulate inside your safe. Please open

If you choose to store delicate items such

for any damage or loss of items placed in

In the event of a fire, potential damage to

your unit periodically to avoid moisture

as jewelry with working parts, watches,

recommend putting them in an air-tight

DO NOT store pearls

stamps, or photos in your safe, we

WARNING

in this safe unit.

the unit due to moisture.

  • If electronics are functioning and you cannot get into safe:
  • You must use both the key (if equipped) and the electronic code to open the safe if the key lock

- Follow instructions for opening your lock type.

accumulation.

for storage.

  • If electronics are not functioning, replace batteries first (behind electronic lock case)

the enclosed registration card.

SentrySafe Fire-Safe Electronic Lock — WARNING diagram (page 4)
Fig. 4

protection have a proprietary insulation that

the SentrySafe advanced safes close airtight

safe. The desiccant packet included in your

safe during shipment, should be left in your

has a high moisture content. In addition

to offer water resistance, which may also

cause moisture to accumulate inside your

safe. DO NOT DISCARD IT. It is intended

items directly in your safe.

DO NOT store delicate

SentrySafe products which offer fire

to help absorb moisture which may

cylinder is pushed in.

WARNING

- Pull handle up

a washer, then through the safe and into a

the back or sides. Bolting/unbolting of the unit is

Group is not responsible for any costs incurred if

9. Securing the safe: A. For wood: Pass each lag screw through

through a washer, then through the safe

at the consumers expense and discretion. Sentry

and into a masonry anchor. Tighten with

hole. Tighten with the wrench. (Fig. E)

B. For masonryPass each lag screw

the unit is to be replaced.

the wrench. (Fig. F)

those in the floor.

6. Move the safe aside to clear both marked spots for drilling.

drill a hole 2-1⁄2" (64 mm) deep in each

drill a hole 2-1⁄2" (64 mm) deep in each

2. Unlock the safe and open the door. 3. Look on the bottom of the safe for two indentations on the feet in opposite

corners. Using the 7⁄16" (11.0 mm) bit,

perpendicular to the bottom of the safe

4. Close the door and tip the safe upright. Place it where desired and reopen the
5. Use a screw or drill bit to mark the floor through both holes. (Fig. C)
7. Drill into the floor: A. For wood: Using the wood drill bit,
B. For masonryUsing the masonry bit,

marked spot. (Fig. D) Install a masonry

8. Replace the safe in the desired position, with the holes in the safe aligned with

drill a hole through each indentation

(Fig. B). Do not drill from any location

1. Tip the safe onto its right side. (Door hinges horizontal with the floor.)
  • (2) Lag screws
  • (2) Washers
  • (2) Masonary anchors Tools needed for floor mounting:

(included on select models only):

4 Floor Mount (optional)

Optional kit (Fig. A) contains

  • Drill
  • Wrench
  • 7⁄16" (11.0 mm) drill bit Wood anchoring:

9⁄32" (7.2 mm) drill bit Masonry anchoring:

3⁄8"(9.50 mm) drill bit

marked spot. (Fig. D)

anchor in each hole.

inside the safe.

Instructions:

door.

A

B

D

E

F

Page 5 of the SentrySafe Fire-Safe Electronic Lock user manual — WARNING
Page 5 · click to enlarge
Page 5
Fire EnduranceExplosion HazardFire ImpactData Protection 1-Hour ModelsSubjected to temperatures up to 1700°F (927°C) for duration of 1-hour, the safe interior will remain below 350°F (177°C). This enables your safe to withstand even high temperature exposure, as the hottest part of a fire moves through a building.Subjected to flash fire in a 2000°F (1093°C) furnace for 30 minutes, the unit will not explode or rupture.After being heated to 1550°F (843°C) the safe is dropped 15 feet onto rubble, then cooled, inverted and reheated to 1550°F (843°C) for 30 minutes.1-hour fire protection of CD’s, DVD’s, memory sticks, and USB drives up to 1700°F (927°C). 1-hour 2.0 Cu. Ft. ModelsSubjected to temperatures up to 1700°F (927°C) for duration of 1-hour, the safe interior will remain below 350°F (177°C). This enables your safe to withstand even high temperature exposure, as the hottest part of a fire moves through a building.Subjected to flash fire in a 2000°F (1093°C) furnace for 30 minutes, the unit will not explode or rupture.After being heated to 1550°F (843°C) the safe is dropped 30 feet onto rubble, then cooled, inverted and reheated to 1550°F (843°C) for 30 minutes.1-hour fire protection of CD’s, DVD’s, memory sticks, and USB drives up to 1700°F (927°C). 2-Hour ModelsSubjected to temperatures up to 1850°F (1010°C) for duration of 2-hours, the safe interior will remain below 350°F (177°C). This enables your safe to withstand even high temperature exposure, as the hottest part of a fire moves through a building.Subjected to flash fire in a 2000°F (1093°C) furnace for 30 minutes, the unit will not explode or rupture.After being heated to 1638°F (892°C), the safe is dropped 30 feet onto rubble, then cooled, inverted and reheated to 1638°F (892°C) for 45 minutes.2-hour fire protection of CD’s, DVD’s, memory sticks, and USB drives up to 1850°F (1010°C).
SentrySafe Fire-Safe Electronic Lock — WARNING diagram (page 5)
Fig. 5

When you move the handle, the compression of the gasket will require slightly more force than you

Endurance Explosion Hazard Fire

ETL Verifi ed Water-Resistance Protection (if equipped)

will not explode or

will not explode or

will not explode or

Tested up to 8 inches of water for up to 24 hours.

to flash fire in a

2000°F (1093°C) furnace for 30

to flash fire in a

2000°F (1093°C) furnace for 30

to flash fire in a

2000°F (1093°C) furnace for 30

would use with a safe that does not have a gasket.

rupture.

rupture.

rupture.

temperature exposure, as the

temperature exposure, as the

temperature exposure, as the

temperatures up to 1700°F

safe to withstand even high

hottest part of a fire moves

temperatures up to 1700°F

safe to withstand even high

hottest part of a fire moves

temperatures up to 1850°F

safe to withstand even high

hottest part of a fire moves

1-hour, the safe interior will remain below 350°F

(177°C). This enables your

1-hour, the safe interior will remain below 350°F

(177°C). This enables your

2-hours, the safe interior will remain below 350°F

(177°C). This enables your

(927°C) for duration of

(927°C) for duration of

(1010°C) for duration of

1-Hour Models Subjected to

2-Hour Models Subjected to

through a building.

through a building.

through a building.

1-hour 2.0 Cu. Ft.

Show 9 more labels / short text on this page
Subjected · Subjected · Subjected · minutes, the unit · minutes, the unit · minutes, the unit · Subjected to · Fire · Models
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the SentrySafe Fire-Safe Electronic Lock

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the SentrySafe Fire-Safe Electronic Lock

Be the first to ask — other owners or our team will answer.

Original document

SentrySafe Fire-Safe Electronic Lock manual PDF

5 pages·190 KB·Safe·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…